Above ranges may be limited by tube selection /AEC limits/incoming power line.
QG-500
50 kW
120 kHz PLUS
40-125 kVp
option
25-650 mA
.001-6.0 sec.
0.025-800 mAs
option
100 APR Views
(5000 Techniques)
1. kVp/mA/time
2. kVp/mAs
3. kVp with AEC*
4.APR/Patient Type
n/a
n/a
standard
option
QG-400
40 kW
120 kHz PLUS
40-125 kVp
option
25-500 mA
.001-6.0 sec.
0.025-600 mAs
option
(w/Three phase input only)
100 APR Views
(5000 Techniques)
1. kVp/mA/time
2. kVp/mAs
3. kVp with AEC*
4.APR/Patient Type
standard
option
option
option
QG-320
32 kW
120 kHz PLUS
40-125 kVp
option
25-500 mA
.001-6.0 sec
0.025-600 mAs
n/a
100 APR Views
(5000 Techniques)
1. kVp/mA/time
2. kVp/mAs
3. kVp with AEC*
4.APR/Patient Type
standard
option
option
option
QG-250
25 kW
120 kHz PLUS
40-125 kVp
option
25-400 mA
.001-6.0 sec.
0.025-500 mAs
n/a
100 APR Views
(5000 Techniques)
1. kVp/mA/time
2. kVp/mAs
3. kVp with AEC*
4.APR/Patient Type
standard
option
n/a
n/a
QG-500-SE
50 kW
120 kHz PLUS
40-125 kVp
n/a
25-600 mA
.001-6.0 sec.
0.025-500 mAs
n/a
100 APR Views
(5000 Techniques)
1. kVp/mA/time
2. kVp/mAs
3. kVp with AEC*
4.APR/Patient Type
Specifications subject to change without prior notice.
QG-400-SE
40 kW
120 kHz PLUS
40-125 kVp
n/a
25-500 mA
.001-6.0 sec.
0.025-500 mAs
n/a
100 APR Views
(5000 Techniques)
1. kVp/mA/time
2. kVp/mAs
3. kVp with AEC*
4.APR/Patient Type
All STORED ENERGY (SE) GENERATORS requires a
standard power input (50/60 Hz) of either:
105-130 VAC, 10 Amp +/- 10% or
210-240 VAC, 10 Amp +/- 10%
QG-320-SE
32 kW
120 kHz PLUS
40-125 kVp
n/a
25-400 mA
.001-6.0 sec.
0.025-400 mAs
n/a
100 APR Views
(5000 Techniques)
1. kVp/mA/time
2. kVp/mAs
3. kVp with AEC*
4.APR/Patient Type
QG-200-SE
20 kW
120 kHz PLUS
40-125 kVp
n/a
25-250 mA
.001-6.0 sec.
0.025-300 mAs
n/a
100 APR Views
(5000 Techniques)
1. kVp/mA/time
2. kVp/mAs
3. kVp with AEC*
4.APR/Patient Type
GENERATOR OPTIONS:
• Automatic Exposure Control (AEC) Electronics: (QG-AEC)
• High (Dual) Speed Starter: (Q-HSS)
• Pedestal Mount for Operator Control Console: (QG-PDL)
• Wall Mount for Operator Control Console: (QG-WM)
• Remote Exposure Hand Switch: (R80-HS)
QWARE
UTILITY SOFTWARE INCLUDED
™
Q-WARE™ is a laptop-based service support tool that
provides an advanced level of APR text and technique editing,
simplified calibration as well as other set-up functions.
STORED ENERGY SE GENERATORS
Quantum’s advanced Stored Energy (SE) technology permits
powerful operation using only a standard “low amperage” wall
outlet or alternate power source. The SE’s
power cells are virtually maintenance-free
and provide years of usage. These units are
ideal in facilities where incoming power
is unavailable and for mobile imaging
applications. (50kW to 20kW)
The QUEST HF’s control panel can be
positioned on a custom pedestal, fastened to
3.13 (79.5)
6.5 (165)
Note: All dimensions are in inches (mm)
a wall for space saving, desktop mounted, or
positioned on top of the generator cabinet.
* Recommend 3 in. (76)
20.66 (525)*
34.72 (882)
clearance from wall for cabling.
24 (610)
Quantum Medical Imaging, LLC
2002 Orville Drive North
Ronkonkoma, NY 11779 USA
Tel (631) 567-5800
Fax (631) 567-5074
www.quantummedical.net
17 (432)
QUEST HF SERIES
120 kHz ULTRA High Frequency
X-Ray Technology
QUANTUM MEDICAL IMAGING
Quantum Medical Imaging is a designer and manufacturer of
advanced radiographic systems and state-of-the-art ULTRA
High frequency generators for use throughout hospitals and
clinics. An unwavering focus on developing X-ray systems
with specialized features has made Quantum a leading
manufacturer for medical imaging facilities worldwide.
Quantum’s progressive approach to emerging
technologies and quality control assures users that
the company’s products meet and exceed the most
stringent international standards and guidelines.
Quantum’s worldwide dealer network provides
factory-authorized sales and service for all Quantum
products. As members of the exclusive Gold Star
Network, these dealers provide superior technical support
and customer service.
THE QUEST HF SERIES
The QUEST HF Series provides an innovative solution
for today’s challenges in radiographic imaging. Merging
sophisticated technology and system architecture with
a simple, menu-driven program, the design team at
Quantum Medical Imaging has addressed the concerns
of technologists and clinicians.
The QUEST HF’s ULTRA High frequency technology
permits a near-constant potential of up to 120 kHz, for
highly efficient, superbly precise imaging. A simple
operating program, with integrated user prompts,
permits a wide range of routine, specialized and
custom examinations.
The QUEST HF Series generator offers superior
flexibility and user-friendliness for complete, high
quality radiographic imaging without compromise.
™
SUPERIOR IMAGING TECHNOLOGY...
TYPICAL KVP OUTPUT WAVEFORM
10 KVP / DIVISION
• HIGHER MR/MAS
• SHORTER
EXPOSURE TIMES
• REDUCED PATIENT
DOSE
• LONGER TUBE LIFE
• SUPERIOR IMAGING
QUALITY
120 KHZ ULTRA HIGH FREQUENCY
•
Near constant potential of up to 120 kHz operating frequency
• ULTRA high frequency imaging enables greater efficiency,
shorter exposure time, and minimized patient dose
• Output ranges of 50 kW through 20 kW (and up to
150 kVp) satisfies varying imaging requirements
• Stored Energy models (50kW - 20 kW) enable operation
using low amperage or alternate power sources
ADVANCED FEATURES
• Three discrete modes of operation with 2 advanced submodes
for optimized imaging:
-
APR (Anatomical Programmed Radiography)
• APR/AEC
• APR/PATIENT TYPE
- AEC (Automatic Exposure Control)
- Manual
• Multi-language selection feature for APR Mode
• Integrated self-diagnostic and self-test programs indicate
system performance and detailed history
• X-ray tube protection circuitry
• Automatic line voltage compensation
• RS-232 interface enables remote functions
• Automatic shut-off timer (variable time settings)
• Generator and X-ray tube exposure counter
• X-Ray Tube Anode "Heat Unit" monitor
• Contemporary and compact design
• Direct Digital Radiography (DR) interface capability utilizing
Quantum’s D-QiX Imaging Solutions
2 MSEC / DIVISION
kVp=70 • mA=500 • time=10 msec
2
GENERATOR OPERATING MODES
The QUEST HF Series enables users to select from three main
operating modes (3 point, 2 point or 1 point), offering great
versatility for pre-programmed or customized imaging.
ANATOMICAL PROGRAMMED RADIOGRAPHY APR
Accessing a menu with over 100 examination views derived from 10
anatomical regions, the APR mode automatically determines and sets
the required technique factors. These parameters include kVp, mA, time
(mAs), focal spot, film speed, SID and imaging receptor. In addition, the
operator may input the actual patient thickness (in cm’s) providing the
optimal technique parameters for that exam. Each individual examination
view provides up to 50 different technique factors, depending upon the
size of the patient, for up to 5000 total anatomical programs.
APR/AEC MODE
The APR mode, when used in cooperation with AEC, provides
superb uniformity of images and virtually eliminates the need
for retakes. The AEC ionization chamber control will
automatically terminate the exposure at the precise interval
needed for the optimal density of the film.
APR/PATIENT TYPE MODE
The Patient Mode is prompted when APR is used without an
AEC function. This innovative feature permits the operator to
change the mAs (time) to accommodate for differences in
actual patient densities. A quick key, controlling increments of
+/- 25% or 50%, permits rapid adjustment from the patient
type defined as “average.”
AUTOMATIC EXPOSURE CONTROL AEC MODE
The dedicated AEC mode provides exceptional uniformity and image
consistency through the automatic termination of exposure at the precise
mAs required for a perfect film. The system also provides an 11-step
selection of AEC density (in 15% increments) for complete operator
control. The operator may choose from various film speed combinations.
MANUAL MODE
The Manual Mode permits the operator to custom-select all
technique parameters (mA, kVp, mAs/time).
STEP
1
SELECT ANATOMICAL REGION FROM APR MENU
CHEST
STEP
2
SELECT DESIRED VIEW FROM MENU
OBLIQUE
STEP
3
READY FOR EXPOSURE*
*In all operating modes, the user always has the capability to
override any technique parameter individually, providing
uncompromised flexibility and control.
Time and date are displayed
for operator convenience.
In addition, the control panel allows the user to
toggle between viewing either mAs or SEC (time).
Quantum generators and systems are already designed to allow use of direct
digital imaging technology (DR) as well as all CR solutions.