Pach & Co. thanks and congratulates you on the purchase of your Quantum QR5. The Quantum
QR5 is a residential and multi tenants telephone entry system.
The manual is designed to guide you through the detail in programming and use of the Quantum
QR5. It is important for you to read and follow the manual completely.
Pach & Co. new products are warranted to be free of defects in material or workmanship for a
period of
wholesale customers who buy direct from Pach & Co. or through Pach & Co.’s normal distribution
channels.
Pach & Co. does not warrant this product in any way to the end user consumer. Consumers must
obtain warranty information from the selling dealer and/or installer as to the nature of the dealer’s
warranty, if any. All contact to Pach & Co. from the end user consumer will be referred to the
consumer’s selling dealer and/or installer.
There are no obligations and/or liabilities on the part of Pach & Co. for consequential damages
arising out of or in connection with use or performance of Pach & Co. products or other indirect
damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or
reinstallation. Any use or change to Pach & Co. products not expressly approved by the
manufacturer, and performed by an authorized dealer/installer will immediately void the warranty.
All implied warranties, including warranties for marketability as well as implied warranties for
suitability, are valid only until the warranty expires or is voided, whichever comes first. Please visit
www.pach-co.com for the warranty in more detail.
two years, (24 months), from the date of purchase. This warranty extends only to
SPECIFICATION
Hardware
Input power 12VAC/DC-18VAC/DC (12 VAC 40VA supplied)
Current consumption 500-750 mA
Single Line Liquid Crystal Display
Built-in Radio Frequency Receiver
Built-in 26 Bit Wiegand Card Reader
12 Vdc camera power
Lock and keys
Two Auxiliary input
Operating environment 10ºF-140ºF
Relative Humidity 0%-95% non-condensing
Double 3/4" knock-out on the back and bottom panel
Dimension: 9-3/4"(L) x 6-3/8"(W) x 1-3/4"(D)
Features
100 access codes (4, 5, 6, 7, 8 digit) and 200 cards
10 temporary access codes valid 1-10 times
10 special access codes to hold open and close
10 programmable call forwarding phone number
Built-in 26 Bit Wiegand Card Reader and Radio Reader
Automatic call forwarding
Automatic card enrollment
Access code and card block programming
Two Auxiliary inputs
Two Door Sensors
600 event buffer (only available with TCP/IP Internet Explorer Browser programming)
Lighted keypad
Two independent on board relay are available on the Quatum QR5, means you can control
two different doors independently. Each relay supports NO (normally open) and NC
(Normally Closed) contact. No power is supplied by the relays therefore you
separate power for door strike. Check the voltage requirements with door strike
manufacturer or refer to door strike owner's installation manual. DO NOT share power with
the Quantum QR5.
Relay rating: 250VAC/12A, 120VA/15A, 24VDC/15A. The relay supplies normally open (NO)
and normally closed (NC).
The Quantum QR5 has built-in 26 bit Wiegand card reader, however if you need to use
different card reader, you may do so by disconnecting the existing card reader and replace
with your own 26-bit wiegand card reader as shown on the diagram.
Warning: Compatibility issue may occur.
FIRMWARE UPGRADE CONNECTOR
This connector is used to upgrade the firmware and only use by the manufacturer. Do not
attempt to upgrade the firmware, doing so will void the warranty.
The default Master Code is 0000. If case the Master Code has been forgotten, you may
press and release the button to log on to programming, the screen will show as below
SPEAKER AND MICROPHONE
Speaker = 8.7 ohm
Microphone = 1.542 kOhm
RADIO RECEIVER
The Quantum QR5 has built-in Radio Frequency (RF) Receiver. The transmitter is not
included.
POWER SWITCH
The power switch must be in the OFF (left position) during the installation to avoid any
damages to the board. Check all the wiring, then turn the power switch ON (right position).
The system will initialize and the display will show scrolling message as shown partially
below
10 call forwarding directories can be programmed in the system. The call forwarding can be
used to call direct or as an automatic call forwarding based on the programming on function
code: 32 Select call forwarding directory. The call forwarding will not work if the system is
A maximum of 100 access codes can be programmed in the system. The access code can be
set in 4, 5, 6, 7 and 8 digit, see
digit access code has been selected on
function code 09, default setting is 4-digit. For example, If 8
The access code can be set to 4 (default setting), 5, 6, 7 or 8 digit thru the programming, once
the number of digit has been set, then all the access codes must have same number of digit.
The Quantum QR5 has built-in 26 bit Wiegand Card Reader and Radio Receiver. A maximum of
100 combination of cards and transmitters can be programmed. Note: 26 bit wiegand access
card, fob and transmitter are optional and they are proprietary to Pach and Company.
The quantum QR5 has event recording tracking capability. You must use Internet Explorer
browser and optional TCP/IP box to use this feature. The event buffer must be initialized in
case of corruption or to start from fresh.
The Auto unlock schedules are used to open and close the door according to the time
schedules programmed in the system. A maximum 10 Auto unlock schedules can be
programmed in the system. For example:Schedule: 0, Open time: 0600, Close time:
1800, Day: 0 1 2meaning the door will be opened at 06:00 AM and closed at 06:00 PM on
Sunday, Monday and Tuesday. This schedule will be repeated every week.
The Auxiliary Input 1 (AUXIN 1) can be use for exit switch, loop detector or any dry contact
input devices. The AUXIN 1 is associated with relay 1 (door 1).
The Auxiliary Input 2 (AUXIN 2) can be use for exit switch, loop detector or any dry contact
input devices. The AUXIN 2 is associated with relay 2 (door 2).
Do Not Disturb will disable the call feature on the Quantum QR5 just incase if you do not want
to be disturb by the visitors. Time zone can also be set on Do not disturb, see function code
The Lock Out Count can be set 1-9. The system will be locked if invalid access (master code,
access code or card) has been entered according to the lock out count programmed.
The length of time for the two party to communicate using the system. The system will
disconnect the call if the talk time is expired. A minute before the talk time expired, the system
will beep. The tenant can extend the talk time by
The system can be programmed for automatic call forwarding. The automatic call forwarding
only works if the system is installed as an intercom. The call forwarding time must be set
before the answering machine or voice mail answering the call, otherwise call forwarding time
will not be activated.
Door 1 and door 2 can be open and hold open and close using a special code. A valid code
must be entered to hold door 1, door 2 or both open and must be re-entered same code to
close door1, door 2 or both.
Up to 10 temporary cards or transmitters can be programmed for limited number of used (0110 times). The cards and transmitters will be deleted after number of used expired.
Door 1 and door 2 can be open and hold open and close using card, fob or transmitter. A valid
code must be entered to hold door 1, door 2 or both open and must be re-entered same code
to close door1, door 2 or both.
By default calling the Quantum QR5 from the premise phone (intercom Mode only),
must be pressed. The key may not work on certain area or phone service, therefore
The Quantum QR5 will answer incoming call from an outside line. The system answer mode
must be enabled by selecting the number of ring. The number of rings can be set from 1st-9th
ring before the system answer. This feature can also set to disabled by selecting 0.
The tenant can press associated keypad key to release the door or gate. By default is number 9
key to release door 1 (relay 1) or 8 for door 2 (relay 2). This feature can be enabled or
disabled.
It is to disable a call button ( ) according to the time zone programmed. No one can call
from the system. 10 Do Not Disturb Time Zones can be programmed in the system.
This function code will erase the memory to factory default. All the programming cannot be
recovered unless if you program the system with optional TCP/IP Browser programming.
The default Master Code is 0000. If case the Master Code is not available, you may press and
release the button to log on to programming, the screen will show as below