Scalar 50 and PX5xx (V51) includes several new features and enhancements that
extend its capabilities. These release notes describe these new features and
enhancements, as well as currently known issues and issues that were resolved
for this release of the product. These notes also provide drive and auxiliary
firmware compatibility information. Visit
information about Scalar 50 and PX5xx and previous releases.
Quantum, DLT, DLTtape, the Quantum logo, and the DLTtape logo are all registered trademarks of Quantum Corporation. SDLT and Super
DLTtape are trademarks of Quantum Corporation. Other trademarks may be mentioned herein which belong to other companies.
http://www.quantum.com for additional
Page 2
Release Notes
Document 5502252 Rev C
August 2008
New Features and Enhancements0
• Scalar 50 and PX5xx (V51) includes the following feature for this new product launch.
Caution:With
•Added support for the HP LTO-4 Half
the release of firmware V51, the media changer’s Fibre Channel
(FC) World Wide Port Name (WWPN) has been changed to be
consistent with other Quantum Scalar libraries and FC target devices.
In the prior firmware release, the WWPN was equal to the World Wide
Node Name (WWNN). In V51 the WWPN is now a value of one
greater than the WWNN. The media changer’s World Wide Port Name
value is reported on the Remote Management Pages under
SCSI/Fibre -> Connectivity/Fibre
firmware revision, this change may result in library not being
available to the host in FC SAN configurations that employ persistent
binding and/or zoning in FC switch(es). An update to persistent
bindings settings or rezoning of the FC switch(es) may be required.
. When upgrading from a prior
Height tape drive (SAS).
Setup ->
Compatibility Matrix0
The following table provides information about library and tape drive firmware
compatibility with Scalar 50 and PX5xx (V51) This information is current as of the
publication date of these release notes.
Scalar 50 Compatibility Matrix
ComponentFirmware Version
Library FirmwareV51
TC2201 iSCSI Bridge6.1.30
Drive Types
Quantum DLT-S4 (SCSI)V42
Quantum DLT-S4 (Fibre)V42
HP LTO-3 (SCSI)G63Z
HP LTO-3 (Fibre)L63Z
HP LTO-4 (SCSI)B44Z
HP LTO-4 (Fibre)H44Z
HP LTO-4 HH (SAS)U25Z
0
2New Features and Enhancements
Page 3
Release Notes
Document 5502252 Rev C
August 2008
ComponentFirmware Version
Quantum LTO-3 HH (SCSI)V20766316-900
Quantum LTO-3 HH (Fibre)V20776316-700
PX5xx Compatibility Matrix0
ComponentFirmware Version
Library FirmwareV51
FC1202 Fibre Channel bridge5.6.2h
Drive Types
Quantum SDLT 320V96
Quantum SDLT 600 (SCSI)V53
Quantum SDLT 600 (Fibre)V53
Quantum DLT-S4 (SCSI)V42
HP LTO-2 (SCSI)F6CZ
HP LTO-3 (SCSI)G63Z
HP LTO-3 (Fibre)L63Z
Resolved Issues0
This release of Scalar 50 and PX5xx (V51) firmware resolved the following issues:
Change
quest
Re
Number
PCR 3929Failure B50B on PX502 during Z di
PCR 4576Improve message if user hits remove when
PCR 4691Retrieval of FA logs should require the library to be offline.
Service
Request
Number
Description
agnostic test (di test 7).
no partition selected/available.
PCR 4697Queued SCSI Unit Attentions are not always returned to all affected initiators.
PCR 4739No critical event was generated when there was a failure to read the RTC which caused the
Remote Management
PCR 9575 Add Tape Alert log to FA log similar to the SuperLoader3 and PX720 (logs TA's per media).
PCR 9592Modify Library code to recognize additional drive SCSI status messages.
Pages and logging to be out of sync.
Resolved Issues3
Page 4
Release Notes
Document 5502252 Rev C
August 2008
Change
Request
Number
Service
Request
Number
Description
PCR 14723If there is a miss-match between the Cartridge Memory (CM) and the element type or
barcode, the system will accept the element type.
PCR 14724Address issues found in Cartridge Memory (CM) reads resulting in invalid densities after
the drive is swapped.
PCR 14733SR: 355614With a bad tape drive, failing unload is taking 45 minutes and it should be 16 minutes.
PCR 16219Improved the error message reported in the Remote Management Pages when the pass-
through elevator test has stopped with an error.
PCR 17100The Remote Management Pages do not reflect the library online state correctly (Java
version 6 issue).
PCR 17370State and Drive Activity fields always display unknown.
PCR 17725SR: 777244Public SNMP community cannot be removed.
PCR 17847SCSI Inquiry does not return the library serial number once a partition is named.
PCR 18206SR: 798660The library Remote Management Pages/ Setup SCSI/Fibre does not report the correct
status.
PCR 19001The Healthtest does not fail but logs a B506 event in the hard que.
PCR 19032Add a test to move a cartridge from the top to the bottom of a library stack (and back)
PCR 19033A Failed move to the Lower Pass-thru leaves the unit stuck in a Moving state.
PCR 19034Remote Management Pages: Allow more than 15 chars in the Find Media ID area.
PCR 19037Add specific text to failed get cartridge events.
PCR 19041Improved media handling in the pass-through.
PCR 19042Add an SNMP and E-mail event to inform user of a Host Reserve on the library.
PCR 19043The OCP does not notify that the tape drive updated has completed when downgrade
finishes.
PCR 19044OCP: Drive operation screen is not correctly updated after drive power off.
PCR 19045Prevents the Pass-through Elevator and the Hand can becoming FULL at the same time
when moving tape cartridges from the Remote Management Pages
PCR 19051The left door is opening up during power-on on some PX502 backplanes.
PCR 19096Improve message if a user hits remove when no partition is selected/available.
PCR 19116The WWNN need to be unique for each partition like SN - Networker autoconfig fails.
PCR 19185Configuration of partitions is allowed (when it shouldn't be) with a Parallel SCSI or iSCSI
library.
PCR 19258SR: 818050The library goes into an unexpected error state and the date and time are incorrect.
PCR 19288SR: 815106Allow the library to configure drives if drive found after the configuration process.
4Resolved Issues
Page 5
Release Notes
Document 5502252 Rev C
August 2008
Change
Request
Number
Service
Request
Number
Description
PCR 19295The pass-through calibration has been improved.
PCR 19345In a partitioned system, from the host interface, you can move a tape in the gripper from
one partition to a second partition.
PCR 19373No UA queued following library offline/online transition (nFC only).
PCR 19387The Hardware Status page is reporting half-height tape drive installation incorrectly.
PCR 19449The format of the serial number on the OCP has been improved.
PCR 19510CDB's are not rejected when the link bit is set in control byte.
PCR 19543When a Fibre Channel switch is attached to a FC Scalar 50, the WWNN and WWPN are
identical.
PCR 19603Setup Wizard creates a partition with invalid elements.
PCR 19635Setup Wizard Configuring SCSI devices panel is not wrapping all windows with Mozilla
firefox.
PCR 19636The Setup Wizard must not include setting up partition options for parallel SCSI and
bridged SCSI hosted systems.
PCR 19674Persistent reserve out register service action doesn't enforce APTPL bit
PCR 19676Reservation conflict status returned to host with a valid I_T nexus registration following
library power cycle with APTPL bit set.
PCR 19852Warn user that reconfiguring slave as a standalone will remove the partitioning
configuration
PCR 19858A perpetual java loop is entered when an operation is attempted requiring the library to go
offline.
PCR 19973Tape stuck in jammed pass-thru is reported in both hands.
PCR 20083Pass-thru slot 2 calibration may be incorrect.
PCR 20084Add optional TA's: cooling fan (0x1B) and power supply (0x1C).
PCR 20119OCP Fibre Channel tape drive and media changer configuration does not work.
PCR 2012628/01 Unit attention presented to host when the I/E load port door is initially opened
instead of only when closed.
PCR 20151Capacity on Demand (COD) should be disabled, all units set to full capacity.
PCR 20171Source element address may become corrupted in a stacked system.
PCR 20193Doors enable default should be changed to enabled.
PCR 20212The library shouldn’t clear tape alerts when only the Log Sense header is requested because
it prevents the host from seeing the actual state of the library.
Resolved Issues5
Page 6
Release Notes
Document 5502252 Rev C
August 2008
Known Issues0
This release of Scalar 50 and PX5xx (V51) firmware has the following known issues:
Change
Request
Number
PCR 17460When logging in through service telnet
PCR 18082False power supply and power supply
PCR 19087OCP/Remote Management Pages: A
PCR 19090 The number of event fields on the OCP
PCR 19188Remote Management Pages: The drive
Service
Request
Number
DescriptionWorkaround
port, the first login always fails.
fan critical events may be logged on
rare occasions.
method is needed to unlock the doors
when a host goes down leaving the
doors in a locked state.
should match what the customer is able
to view (critical, warning, and
information).
firmware update does not refresh to the
new firmware version once the update
completes. It requires a power cycle to
update.
This only occurs with some telnet clients. This
will be corrected in future releases of library
firmware.
This will be corrected in future releases of
library firmware.
Restart the backup application and unlock
resources. This is a usability change that will be
addressed in a future release.
This will be corrected in future releases of
library firmware.
To display the correct drive firmware version
after an update on the Remote Management
Pages, the customer will need to power cycle
the library.
PCR 19242Log Sense page 07 (Last N Error Events)
doesn’t work as reported in the
Software Interface Guide.
PCR 19853The drive firmware update through the
Remote Management Pages sometimes
fails.
PCR 19997During a I/E column port operation, if
Release Magazine is selected from OCP
and tapes are moved around, the library
can fail after the door closes and a rescan occurs.
This will be corrected in future releases of
library firmware.
Try the procedure again, if it still fails use the
primary port connection to update drive
firmware.
If load ports are being accessed, do not attempt
to release the magazine. This will be corrected
in future releases of library firmware
6Known Issues
Page 7
Release Notes
Document 5502252 Rev C
August 2008
Change
Request
Number
PCR 20130The User password is rejected if it
PCR 20354A drive log download from a Quantum
Service
Request
Number
DescriptionWorkaround
contains “_”.
LTO-3 HH tape drive can cause a brief
loss of communication to the remote
management pages. The library status
icon will change to
Down
.
Communication
Do not attempt to use “_” with a user password.
Instead, use another non-alphanumeric
character in its place. This will be corrected in
future releases of library firmware.
This is only a temporary loss of communication
(30 seconds to 2 minutes). After that time, the
communication to the remote management
pages will return. This will be corrected in
future releases of library firmware.
Documentation0
Scalar 50 Documentation 0The following documents are currently available for the Scalar 50 (V51).