Quantum PX502 User Manual

PX502 Tape Library
Quick Start Guide
TABLE OF CONTENTS
Introduction .......................................1
Notational Conventions .................1
Choosing a Location ..........................2
Rack Space Requirements...............2
Environmental Conditions .............2
Providing Necessary Tools..............2
Taking ESD Precautions ..................2
Unpacking the PX502 Tape Library ... 2
Removing the Remaining Packing
Materials.............................................9
Installing the Library .........................3
Locating the Mounting Position ....3
Installing the Library ......................4
Initial Configuration ....................... 9
Multiple Library Stacks....................13

Introduction 0

The PX502 tape library is an automated storage and retrieval device consisting of up to two tape drives and up to 32 SDLT cartridges or 38 LTO tape cartridges (see
figure 1

Notational Conventions 0

This instruction uses the following conventions:
).
N
OTE: Notes emphasize important information related to the main topic.
AUTION: Cautions indicate potential hazards to equipment and are included
C
to prevent damage to equipment.
ARNING: Warnings indicate potential hazards to personal safety and are
W
included to prevent injury.
This document explains how to unpack the PX502 tape library and install it in a standard 19 in. rack. Once the library is unpacked and installed, set up the library using the instructions in the
installation procedure will take approximately 4 hours to complete.
OTE: It is recommended to review the entire document prior to beginning the
N
installation.
Figure 1 PX502 Tape Library
PX500 Series
User’s Guide PN 81-81290. This
PX502 Tape Library Quick Start Guide

Choosing a Location 0

When choosing an installation site for the PX502, consider the following requirements:

Rack Space Requirements

Environmental Conditions

Rack Space Requirements 0
Ta b l e 1 contains the rack requirements for the PX502 tape
library.
Table 1 Rack Requirements
Dimensions PX502
Depth 31 in (78.7 cm)
Width 19 in (48.3 cm)
Height 6.75 in (17 cm), 4U
Weight 52 lbs (23.6 kg)
Air Clearance Open 4 in (10 cm) behind unit
for proper air flow

Providing Necessary Tools 0

Provide the following tools for unpacking and installing the PX502 tape library:
#1 PHILLIPS® screwdriver
#2 PHILLIPS screwdriver
#1 flat blade screwdriver
Allen wrench (2.5mm and 3mm) included in accessory kit
Antistatic wrist strap included in accessory kit

Tak i n g E S D P r e c a u t i o n s 0

Some components within the PX502 tape library contain static-sensitive parts. To avoid damaging these parts while performing installation procedures, always observe the following precautions:
Keep the PX502 turned off during all installation procedures.
Use an antistatic wrist strap (included in the accessory kit).
Keep static-sensitive parts in their original shipping containers until ready for installation. Look for the ESD sticker to identify static sensitive parts.
Environmental Conditions 0
The installation site must have the following environmental conditions:
Humidity: 20%-80% non-condensing
Temperature: 10°C-35°C (50°F-95°F)
Altitude: -500 to 10,000 feet (-152 to 3048 meters)
These environmental conditions apply when the PX502 tape library is in operation.
OTE: For additional specifications, refer to the
N
Quantum PX500 Series User’s Guide
81290)
(PN 81-

Preparing for the Installation 0

Before you begin the installation procedure in this section, make the following preparations as described in this section:
Providing Necessary Tools
Taking ESD Precautions
Avoid touching connectors and other components.
OTE: Dry climates and cold-weather heating
N
environments have lower relative humidity and are more likely to produce static electricity.

Unpacking the PX502 Tape Library 0

This section explains how to unpack the PX502 tape library and move it to its final installation location.
NOTE: Inspect the outer library packaging for damage. If
there is any damage evident on the library packaging, do not continue with the installation and contact Quantum customer support.
2
PX502 Tape Library Quick Start Guide
By following these instructions, you help ensure that the system will continue to be safeguarded after it arrives at the installation site.
OTE: Unpack the library as close to the installation
N
location as possible.
Unpack and remove the following components from the packing materials (see figure 2
):
1 Remove the accessories kit and set it aside.
W
ARNING: At least two people are required to move the
library chassis.
AUTION: Lift the library chassis at the sides. Avoid
C
putting the weight of the library chassis on the front bezel.
2 With the help of a second person, lift the library chassis
up and out of the shipping carton.
3 Place the library on a table approximately waist high.
Figure 2 Unpacking the PX502
Accessory kit
4 Remove the antistatic sheet:
a Cut the tape strips securing the sheet.
b Fold the sheet down.
c With the help of a second person, lift the library up
off of the antistatic sheet.
d Place the library on the table or desk next to the
antistatic sheet.
e If this is a multiple library stack, refer to “Multiple
Library Stacks” on page 13 before proceeding.
The PX502 is ready to install.

Installing the Library 0

Installing a PX502 tape library in a rack consists of the following steps:
Locating the Mounting Position
Installing the Library
Initial Configuration

Locating the Mounting Position

0
Lift point
Foam
PX502 tape library
Front bezel
Foam
The PX502 tape library is designed to fit in a standard 19 inch wide rack.
It is important to the library installation to locate the hole pattern in the rack rails (see figure 3). The library must be installed at the beginning of the hole pattern. Refer to
for information on common rack hole types.
table 2
3
PX502 Tape Library Quick Start Guide
Table 2 Rack Hole Types
Figure Description
Square rack holes are the most common type of rack holes. They can accept either cage nuts which mount from the back of the rail or
Cage nut
clip nuts which clip on from the side of the rack rail.
Clip nut
Through holes require clip nuts to
Clip nut
accept mounting hardware.
Threaded holes require neither cage or clip nuts to accept mounting hardware.
OTE: The rails within the rack have a hole pattern that
N
repeats throughout the rail. X marks the screw positions. Install nut clips (included in the accessory kit) on the rails if necessary.
Figure 3 Rail Hole Pattern
Front panel screws mounting positions
Back panel screws
4U
1 PX502 System (4U)
The marks above (X) indicate the location of mounting hardware on the rack rails. Ensure that any necessary mounting hardware is installed on the rack rails prior to installing the chassis.
mounting positions
Front panel screws mounting positions
1U = 1.75 in
(44.45mm)
Top of rack
Hole pattern
.312 in (7.92 mm) .625 in (15.9 mm) .625 in (15.9 mm)
.5 in (12.7 mm) .625 in (15.9 mm) .625 in (15.9 mm)
.5 in (12.7 mm)
WARNING: If the rack is empty at the time of installation,
do NOT install the PX502 tape library too high in the rack. The weight of the library may cause the rack to become “top heavy” and unstable if installed in the top of an empty rack. Begin installing the PX502 tape library from the bottom of the rack if more than one library is installed.

Installing the Library 0

Installing the PX502 tape library consists of the following steps
:
OTE: If this is an upgrade to an existing library system,
N
see “Multiple Library Stacks” on page 13.
Installing the Rack Mount Shelves
Installing the Library Chassis
Cabling the Library
4
PX502 Tape Library Quick Start Guide
Table 3 Library Mounting Hardware
Qty Figure Description
16 Allen head screws (M5
x 10) for shelf assembly
8 T- nuts (M5)
4 metric and 4 standard
Rail adapters (both metric and standard holes are included, 8 total adapters, see
figure 4
)
2 Right and left support
shelves (left shown)
a Loosely attach the adjustable shelves (right and left)
with 4 M5 x 10 Allen screws and T-nuts.
NOTE: T-Nuts must be oriented so they fit in the grooves
of the shelves.
b Attach the appropriate rail adapter to the front and
back of the rack mount shelves (right and left) with 4 M5 x 10 Allen screws (each rail adapter is marked with the specific hole type supported, either metric or standard). The rail adapters have arrows indicating the proper orientation (see figure 4
).
4 sets Front and back rail
mounting hardware (M5 x 12 allen screws and mounting plates)
2 sets Back bracket
hardware (M5 x 8 allen screws and mounting plate)
2 sets Back clamp hardware
(M5 x 10 and back clamp)
Figure 4 Rail Adapter Orientation
Keep the arrow up for correct orientation
Installing the Rack Mount Shelves
1 Assemble the rack mount shelves by (see figure 5 and
figure 6
):
0
5
PX502 Tape Library Quick Start Guide
Figure 5 Assembling the Left­Hand Rack Mount Shelf
Rail adapter
T-nuts
Rail adapter
Allen screws
2 M4 x 12 Allen screw.
N
Allen screws
OTE: The rack mount shelves must be installed on the
inside rack rails.
Figure 7 Installing the Rack Mount Shelves
f
l
e
h
s
t
f
e
L
Allen screws
FlexLink™ opening located towards the front for the left-hand shelf
Mounting plate
Allen screws
Left shelf Right shelf
Figure 6 Assembling the Right­Hand Rack Mount Shelf
Allen screws
Allen screws
FlexLink opening located towards the back for the right-hand shelf
Rail adapter
R
i
g
h
t
s
h
Allen screws
T-nuts
e
l
f
Rail adapter
2 Install the left and right rack mount shelves into the
rack (the rack mount shelves adjust 27 in. to 36 in.) and secure with the following parts in four locations (see
figure 7
):
Mounting plate
3 Once the rack mount shelves are secured to the rack,
tighten the Allen screws securing the adjustable shelves together.
Installing the Library Chassis
ARNING: The PX502 tape library weighs approximately
W
52 lbs (23.6 kg). At least two people are required to lift and install the library.
1 The back mounting brackets are lettered (A through I)
so the correct mounting position is easily determined. The mounting positions differ depending on the depth of the rack (see table 4
).
0
6
PX502 Tape Library Quick Start Guide
Table 4 Back Mounting Bracket Orientation
Rack Depth Mounting Position
> 27 to 28 in. Use holes A and C
> 28 to 29 in. Use holes B and D
> 29 to 30 in. Use holes A and C
> 30 to 31 in. Use holes B and D
> 31 to 32 in. Use holes C and E
> 32 to 33 in. Use holes D and F
> 33 to 34 in. Use holes E and G
> 34 to 35 in. Use holes F and H
> 35 to 36 in. Use holes G and I
Once the location is determined, attach the back brackets to each side of the library with four M5 x 8 Allen screws (see figure 8
NOTE: Use the shortest depth number. For example, if
the measurement is 34 in., use holes E and G.
).
Figure 8 Installing the Back Mounting Brackets
Back mounting bracket
Allen screws
Right-hand back bracket shown.
N
OTE: If this is a multiple stack configuration, refer to
“Multiple Library Stacks” on page 13 for information on preparing the library chassis for passing tape cartridges from one unit to another.
2 Install the library into the rack as shown in figure 9
secure the library to the rack with four PHILLIPS screws.
ARNING: The PX502 tape library weighs approximately
W
52 lbs (23.6 kg). At least two people are required to lift and install the library.
and
Figure 9 Installing the PX502 in the Rack
PHILLIPS screws
7
PX502 Tape Library Quick Start Guide
3 Secure the back of the library to the rack with two
mounting clamps and two Allen screws on each clamp. The mounting clamps are oriented differently depending on the depth of the rack (see figure 10
N
OTE: If the rack depth is 27 to 30 in., the long portion
).
of the clamp is mounted to the back. If the rack depth is 30 to 36 in., the long portion is mounted to the front.
4 Secure the mounting clamps to the rack rails with two
PHILLIPS screws on each side (see figure 10
).
Figure 10 Securing the Back of the Library
b Insert the tape drive(s) into the drive bay(s) slowly
until the connectors are seated. Refer to figure 12 for drive bay numbering (see the
Tape Drive Installation Instructions
Quantum PX500 Series
PN 81-81301 for
information).
Figure 12 Installing the Tape Drives
Back of Library
Tape drive 2
Tape drive 1
c Tighten the tape drive thumbscrews using a flat
blade screwdriver.
d Repeat these steps to install another tape drive in a
different location, if desired.
The library chassis is installed in the rack.
Long portion
Right-hand back bracket shown.
Allen screws
5 To install the tape drives into the library:
a Remove the tape drive cover plates (if necessary,
some libraries ship with one tape drive installed) by loosening the captive screws securing the plate to the library chassis (see figure 11
).
Figure 11 Removing the Tape Drive Cover Plates
Tape drive bay 1
Cabling the Library
1 Connect the SCSI cables and jumpers as shown in the
following figures:
Figure 13 SCSI System Controller Board
Figure 14 Surrogate SCSI System Controller Board
Figure 15 Native Fibre Channel System Controller Board
NOTE: Quantum ships sufficient SCSI cables and
terminators with the libraries to set up two-drives per SCSI bus. One tape drive per SCSI bus may be necessary for optimum performance. Refer to your tape drive documentation.
OTE: SCSI cable lengths should not exceed:
N
39.37 feet (12 meters) between the host and the library for single drive per bus installations.
0
Tape drive bay 2
Cover plate
8
PX502 Tape Library Quick Start Guide
Figure 13 PX502 Cable Configuration (SCSI System Controller Board)
Ethernet
SCSI host
Power
Figure 14 PX502 Cable Configuration (Surrogate)
Surrogate System Controller Board
Tape drive 2 Tape drive 1
SCSI System Controller Board
Tape drive 1Tape drive 2
Back of Library
SCSI hostEthernet

Initial Configuration 0

Initially configuring the library consists of the following steps:
Turning on the Library
Removing the Remaining Packing Materials
Setting the Library Options
Setting the Date and Time
Setting Network Information
Turning on the Library
To turn on the library:
1 Verify that:
Power cables are firmly in place
All doors are closed and latched
2 Turn on the library by pushing power button located on
the bottom left-hand corner of the OCP (see figure 16
Figure 16 Turning on the Library
0
).
Power
N
OTE: When operating in surrogate mode, the SCSI host
Back of Library
connection must be made to tape drive 1.
Figure 15 PX502 Cable Configuration (Native Fibre Channel)
Ethernet
Fibre Channel host/SAN
Tape drive 2 Tape drive 1
Power
Tape Drive Fibre Channel host ports
Back of Library
2 Connect one end of an AC power cable to each
installed power supply and to a wall outlet.
OCP
Power button
The power up sequence can take several minutes. The first message displaying will be “Are the internal packaging materials removed?” Continue with
Removing the Remaining Packing Materials
Removing the Remaining Packing Materials
Now that you have installed the library chassis and powered on the system, you MUST remove the remaining packing materials from the library chassis before the library is operational.
0
9
PX502 Tape Library Quick Start Guide
1 Put on an antistatic wrist strap and clip it to the library
chassis.
CAUTION: Take standard ESD precautions when
performing this procedure.
2IF there is space above the library to remove the top
cover, remove the twelve PHILLIPS screws securing the top cover and FlexLink cover to gain further access to the internal packaging restraints (see figure 17
). If there is no space above the PX502 library to remove the top cover, continue with Step 3.
Figure 17 Removing the Top Cover (Optional Step)
4 Press NO to continue. The system asks you again: “Are
the internal packaging materials removed?” (OK or NO).
C
AUTION: Pressing OK when the internal packaging
restraints are in place will damage the library robotics.
5 Press NO to continue. The OCP displays “Doors opened,
magazines released, pull magazines out before power shutoff. The library waits approximately 30 seconds for you to open the doors and remove both magazines from the library.
NOTE: If you are unable to remove the magazines before
the library shuts down. Turn on the library power and repeat the steps above.
6 After the library has powered down, remove the foam
restraints by completing the following steps (see
figure 18
):
a Detach the tie band holding the two sides of the
metal restraints together and remove it from the library.
b Remove the metal restraints from the library.
c Lift the left foam restraint slightly up and remove it
from the library.
d Slide the right foam restraint to the right until you
are clear of the robotics motor and remove the restraint from the library.
3 When the library powers on for the first time, the OCP
asks you: “Are the internal packaging materials removed?” (OK or NO).
AUTION: Avoid touching the printed circuit board.
C
AUTION: When removing the foam restraints, ensure
C
that the robotics umbilical cable is lying down in the correct position and not across the robotics track.
10
PX502 Tape Library Quick Start Guide
Figure 18 Removing the Foam Restraints
Tie band
Setting the Library Options
To set the library options:
1 Turn on the library by pushing power button located on
the bottom left-hand corner of the OCP (see figure 16).
2 The OCP asks you: “Are the internal packaging materials
removed?” (OK or NO).
3 Press OK to continue.
4 The OCP asks again: “Are the internal packaging
materials removed?” (OK or NO).
5 Press OK to continue. The library continues the boot
process. When complete, the Home screen displays.
6 Press Setup from the Home screen. The OCP displays
the Setup screen (see figure 19):
Figure 19 Setup Screen
0
Metal restraint
Foam restraints
Robotics umbilical
Metal restraint
OTE: Save the robotics restraints and re-usable tie wrap
N
cable
for later shipping or relocation of the library.
e Install the tape cartridge magazines.
OTE: Refer to the
N
PX500 Series User’s Guide
(PN 81-
81290) for more information on loading the tape cartridge magazines.
f Close the front doors.
g If you have removed the top cover for better access,
install the top cover back on the library.
Enter
7 From the Setup screen, use the up and down arrows to
highlight Cabinet and press Enter. The Cabinet screen displays (see figure 20):
Figure 20 Library Options Screen
8 The Stack role screen allows you to configure the
library as a “Master” or “Slave” in a multiple library stack. The library is configured “Solo” by default. If this is a multiple library stack, use the up and down arrows to highlight Stack role and press Enter displays the following information about the library:
11
PX502 Tape Library Quick Start Guide
Table 5 Setting Up the Cabinet
Cabinet Options Description
Host bus Sets the SCSI ID for both the
library and tape drives.
Stack role Assigns the library stack role
as Master, Slave, or Stand alone (solo). There can be only one Master library in a multiple stack. Once configured as a slave, all library OCP functions can be controlled via the Master library OCP. The library model number will also change to PX500S indicating a stacked library configuration. The library model number is available from the home screen on the Master library OCP.
Left load port Enables or disables the left
load port
2 Use the up and down arrows to view or edit the date
and time information. Press Enter to accept the new settings.
3 When you are finished viewing/editing the date and
time information, press Exit to return to the Setup screen.
Setting Network Information
To view or edit the network information:
N
OTE: The library must be offline to change these
settings.
1 From the Setup screen, use the up and down arrows to
highlight Network and press Enter. The Network screen displays (see figure 22):
Figure 22 Network Screen
0
Right load port Enables or disables the right
load port
Drive FUP from tape Allows you to perform a tape
drive firmware update from a firmware update tape cartridge.
Setting the Date and Time
To set the date and time:
1 From the Setup screen, use the up and down arrows to
highlight Date and Time and press Enter. The Date and Time screen displays (see figure 21
):
Figure 21 Date and Time Screen
The Network screen allows you to view or edit the following network settings:
DHCP (default setting)
0
IP address
Subnet mask
•Default gateway
2 Use the up and down arrows to select the network
setting you wish to view or edit and press Enter.
When you are finished viewing/editing the network information, press Back to return to the Setup screen.
3 For the network information such as the IP address to
be active, you must reboot the library by holding down the power button located on the front of the library (see figure 16).
The library shuts down.
4 Push the power button to start the library.
The PX502 tape library is initially configured and ready for use.
The Date and Time screen displays the following information about the library:
12
PX502 Tape Library Quick Start Guide

Multiple Library Stacks 0

N
OTE: If the library is NOT being installed with other
libraries to operate in a multiple library stack, it is not necessary to complete the following instructions.
If the library will be installed in a rack with other PX500 Series libraries, you must prepare each chassis prior to installation. Preparing the library chassis for installation into a multiple library stack consists of:
OTE: It is recommended to place the Master library in
N
the middle of the library stack for improved performance.
Removing the FlexLink cover plates
Installing the alignment hardware
To prepare the library chassis for multiple stack operation:
1 Remove two PHILLIPS screws securing each FlexLink
cover located on the top and bottom of the library using a #1 PHILLIPS screwdriver (see figure 23
).
Figure 23 Removing the FlexLink Cover
p
o
T
m
o
t
t
o
B
Remove only the top FlexLink cover on the bottom library in the stack
Screws
FlexLink cover
FlexLink cover
Screws
NOTE: Remove the bottom FlexLink cover on every library
except the bottom library in the stack. Remove the top FlexLink cover on the bottom library in the stack.
Remove only the bottom FlexLink cover on the top library in the stack
2 The alignment hardware installed on the top and
bottom of the libraries in a multiple stack allow the FlexLink bays to align correctly when installed in a rack. Install the following alignment hardware (see
figure 24
):
a Install the top alignment hardware with two Allen
head screws.
b Install the bottom alignment hardware with one
Allen head screw.
N
OTE: Install only the bottom alignment hardware on
the top library in the stack and the top alignment hardware on the bottom library in the stack.
13
PX502 Tape Library Quick Start Guide
Figure 24 Installing the Alignment Hardware
Top alignment hardware
p
o
T
Screws
m
o
t
t
o
B
Screws
Bottom alignment hardware
The libraries are prepared for installation in a multiple stack.
United States of America Quantum Corporation 141 Innovation Drive Irvine, CA 92612 U.S.A. phone 949.856.7800 fax 949.856.7799
©2006 Quantum Corporation. Quantum, the Quantum logo, and the DLTtape logo are all registered trademarks of Quantum Corporation. SDLT and Super DLTtape are trademarks of Quantum Corporation. Other trademarks may be mentioned herein which belong to other companies.
European Headquarters Quantum Corporaton 3 Bracknell Beeches Old Bracknell Lane West Bracknell Berkshire RG12 7BW United Kingdom phone +44 1344 353500 fax +44 1344 353510
Asia Pacific Quantum Corporaton Level 3 200 Creek Street Brisbane, Qld 4000 Australia phone +61 7 3839 0950 fax +61 7 3839 0955
81-81292-02 A01 January 2006
Loading...