Quantum PX502 User Manual

PX502 Tape Library
Quick Start Guide
TABLE OF CONTENTS
Introduction .......................................1
Notational Conventions .................1
Choosing a Location ..........................2
Rack Space Requirements...............2
Environmental Conditions .............2
Providing Necessary Tools..............2
Taking ESD Precautions ..................2
Unpacking the PX502 Tape Library ... 2
Removing the Remaining Packing
Materials.............................................9
Installing the Library .........................3
Locating the Mounting Position ....3
Installing the Library ......................4
Initial Configuration ....................... 9
Multiple Library Stacks....................13

Introduction 0

The PX502 tape library is an automated storage and retrieval device consisting of up to two tape drives and up to 32 SDLT cartridges or 38 LTO tape cartridges (see
figure 1

Notational Conventions 0

This instruction uses the following conventions:
).
N
OTE: Notes emphasize important information related to the main topic.
AUTION: Cautions indicate potential hazards to equipment and are included
C
to prevent damage to equipment.
ARNING: Warnings indicate potential hazards to personal safety and are
W
included to prevent injury.
This document explains how to unpack the PX502 tape library and install it in a standard 19 in. rack. Once the library is unpacked and installed, set up the library using the instructions in the
installation procedure will take approximately 4 hours to complete.
OTE: It is recommended to review the entire document prior to beginning the
N
installation.
Figure 1 PX502 Tape Library
PX500 Series
User’s Guide PN 81-81290. This
PX502 Tape Library Quick Start Guide

Choosing a Location 0

When choosing an installation site for the PX502, consider the following requirements:

Rack Space Requirements

Environmental Conditions

Rack Space Requirements 0
Ta b l e 1 contains the rack requirements for the PX502 tape
library.
Table 1 Rack Requirements
Dimensions PX502
Depth 31 in (78.7 cm)
Width 19 in (48.3 cm)
Height 6.75 in (17 cm), 4U
Weight 52 lbs (23.6 kg)
Air Clearance Open 4 in (10 cm) behind unit
for proper air flow

Providing Necessary Tools 0

Provide the following tools for unpacking and installing the PX502 tape library:
#1 PHILLIPS® screwdriver
#2 PHILLIPS screwdriver
#1 flat blade screwdriver
Allen wrench (2.5mm and 3mm) included in accessory kit
Antistatic wrist strap included in accessory kit

Tak i n g E S D P r e c a u t i o n s 0

Some components within the PX502 tape library contain static-sensitive parts. To avoid damaging these parts while performing installation procedures, always observe the following precautions:
Keep the PX502 turned off during all installation procedures.
Use an antistatic wrist strap (included in the accessory kit).
Keep static-sensitive parts in their original shipping containers until ready for installation. Look for the ESD sticker to identify static sensitive parts.
Environmental Conditions 0
The installation site must have the following environmental conditions:
Humidity: 20%-80% non-condensing
Temperature: 10°C-35°C (50°F-95°F)
Altitude: -500 to 10,000 feet (-152 to 3048 meters)
These environmental conditions apply when the PX502 tape library is in operation.
OTE: For additional specifications, refer to the
N
Quantum PX500 Series User’s Guide
81290)
(PN 81-

Preparing for the Installation 0

Before you begin the installation procedure in this section, make the following preparations as described in this section:
Providing Necessary Tools
Taking ESD Precautions
Avoid touching connectors and other components.
OTE: Dry climates and cold-weather heating
N
environments have lower relative humidity and are more likely to produce static electricity.

Unpacking the PX502 Tape Library 0

This section explains how to unpack the PX502 tape library and move it to its final installation location.
NOTE: Inspect the outer library packaging for damage. If
there is any damage evident on the library packaging, do not continue with the installation and contact Quantum customer support.
2
PX502 Tape Library Quick Start Guide
By following these instructions, you help ensure that the system will continue to be safeguarded after it arrives at the installation site.
OTE: Unpack the library as close to the installation
N
location as possible.
Unpack and remove the following components from the packing materials (see figure 2
):
1 Remove the accessories kit and set it aside.
W
ARNING: At least two people are required to move the
library chassis.
AUTION: Lift the library chassis at the sides. Avoid
C
putting the weight of the library chassis on the front bezel.
2 With the help of a second person, lift the library chassis
up and out of the shipping carton.
3 Place the library on a table approximately waist high.
Figure 2 Unpacking the PX502
Accessory kit
4 Remove the antistatic sheet:
a Cut the tape strips securing the sheet.
b Fold the sheet down.
c With the help of a second person, lift the library up
off of the antistatic sheet.
d Place the library on the table or desk next to the
antistatic sheet.
e If this is a multiple library stack, refer to “Multiple
Library Stacks” on page 13 before proceeding.
The PX502 is ready to install.

Installing the Library 0

Installing a PX502 tape library in a rack consists of the following steps:
Locating the Mounting Position
Installing the Library
Initial Configuration

Locating the Mounting Position

0
Lift point
Foam
PX502 tape library
Front bezel
Foam
The PX502 tape library is designed to fit in a standard 19 inch wide rack.
It is important to the library installation to locate the hole pattern in the rack rails (see figure 3). The library must be installed at the beginning of the hole pattern. Refer to
for information on common rack hole types.
table 2
3
PX502 Tape Library Quick Start Guide
Table 2 Rack Hole Types
Figure Description
Square rack holes are the most common type of rack holes. They can accept either cage nuts which mount from the back of the rail or
Cage nut
clip nuts which clip on from the side of the rack rail.
Clip nut
Through holes require clip nuts to
Clip nut
accept mounting hardware.
Threaded holes require neither cage or clip nuts to accept mounting hardware.
OTE: The rails within the rack have a hole pattern that
N
repeats throughout the rail. X marks the screw positions. Install nut clips (included in the accessory kit) on the rails if necessary.
Figure 3 Rail Hole Pattern
Front panel screws mounting positions
Back panel screws
4U
1 PX502 System (4U)
The marks above (X) indicate the location of mounting hardware on the rack rails. Ensure that any necessary mounting hardware is installed on the rack rails prior to installing the chassis.
mounting positions
Front panel screws mounting positions
1U = 1.75 in
(44.45mm)
Top of rack
Hole pattern
.312 in (7.92 mm) .625 in (15.9 mm) .625 in (15.9 mm)
.5 in (12.7 mm) .625 in (15.9 mm) .625 in (15.9 mm)
.5 in (12.7 mm)
WARNING: If the rack is empty at the time of installation,
do NOT install the PX502 tape library too high in the rack. The weight of the library may cause the rack to become “top heavy” and unstable if installed in the top of an empty rack. Begin installing the PX502 tape library from the bottom of the rack if more than one library is installed.

Installing the Library 0

Installing the PX502 tape library consists of the following steps
:
OTE: If this is an upgrade to an existing library system,
N
see “Multiple Library Stacks” on page 13.
Installing the Rack Mount Shelves
Installing the Library Chassis
Cabling the Library
4
PX502 Tape Library Quick Start Guide
Table 3 Library Mounting Hardware
Qty Figure Description
16 Allen head screws (M5
x 10) for shelf assembly
8 T- nuts (M5)
4 metric and 4 standard
Rail adapters (both metric and standard holes are included, 8 total adapters, see
figure 4
)
2 Right and left support
shelves (left shown)
a Loosely attach the adjustable shelves (right and left)
with 4 M5 x 10 Allen screws and T-nuts.
NOTE: T-Nuts must be oriented so they fit in the grooves
of the shelves.
b Attach the appropriate rail adapter to the front and
back of the rack mount shelves (right and left) with 4 M5 x 10 Allen screws (each rail adapter is marked with the specific hole type supported, either metric or standard). The rail adapters have arrows indicating the proper orientation (see figure 4
).
4 sets Front and back rail
mounting hardware (M5 x 12 allen screws and mounting plates)
2 sets Back bracket
hardware (M5 x 8 allen screws and mounting plate)
2 sets Back clamp hardware
(M5 x 10 and back clamp)
Figure 4 Rail Adapter Orientation
Keep the arrow up for correct orientation
Installing the Rack Mount Shelves
1 Assemble the rack mount shelves by (see figure 5 and
figure 6
):
0
5
Loading...