Quantum PX500 Series, PX506, PX502, PX510, FC1202 Upgrade Instructions

Quantum PX500 Series
FC1202 Upgrade Instructions
Introduction 3
Fibre Channel Description........................................................................... 3
FC1202 Bridge Operation............................................................................. 3
Preparing for the FC1202 Installation 4
Required Upgrade Kits ................................................................................ 4
Required Tools .............................................................................................. 4
FC1202 Upgrade Procedure 4
Preparing the Quantum PX500 Series Library ......................................... 5
Removing Tape Drive SCSI Jumper Cables.............................................. 6
Installing the FC1202 Bridge .......................................................................9
Installing the Ethernet Cables ................................................................... 13
Installing SCSI Jumper Cables .................................................................. 17
Configuring the FC1202 Bridge Software................................................ 19
Saving the Configuration File ................................................................... 25
Enabling Serverless Backup (Xcopy)........................................................ 27
Zoning the Ethernet Switch 29
81-81351-01 C01, April 2006 1
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 C01 April 2006
Made in the USA.
Quantum Corporation provides this publication “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice.
© Copyright 2006 by Quantum Corporation. All rights reserved.
Your right to copy this document is limited by copyright law. Making copies or adaptations without prior written authorization of Quantum Corporation is prohibited by law and constitutes a punishable violation of the law.
Capacity on Demand (CoD), Crosslink Mechanism, DLT, DLTSage, DLTtape, Super DLTtape, Performance on Demand, (PoD), PRISM, PRISM Storage Architecture logo, SiteCare, StackLink, StorageCare, SuperLoader, and ValueLoader are all trademarks of Quantum Corporation. Quantum, the Quantum logo, and the DLTtape logo are all registered trademarks of Quantum Corporation.
Other trademarks may be mentioned herein which belong to other companies.
2
COPYRIGHT STATEMENT
TRADEMARK STATEMENT
Quantum PX500 Series FC1202 Upgrade Instructions
81-81351-01 C01
April 2006
Introduction 0
The Quantum PX500 Series automated tape libraries are controlled by a host computer via a SCSI LVD bus using the SCSI-3 medium changer command set.
The Quantum PX500 Series allows for easy conversion from the SCSI host interface to a Fibre Channel host interface. This document describes upgrading a standard PX500 library equipped with a SCSI host interface to a Fibre Channel host interface using a FC1202 Upgrade kit.
Fibre Channel Description
FC1202 Bridge Operation
Fibre Channel is a serial data transfer architecture for use with computers and
0
0
mass storage devices that is rapidly emerging to challenge SCSI as the interface of choice for host-to-storage applications.
Fibre Channel advantages include:
Connection distances with the Quantum FC1202 option up to 500 meters
1 GB/Sec, 2 GB/Sec, or autosense data transfer rates
Supports up to 126 devices in a loop mode
Supports 24-bit addressing for over 16 million devices in point-to-point mode or fabric, when using a Fibre Channel switch or multiple Fibre Channel switches.
Operating system independence
Interconnect flexibility
Once a FC1202 bridge option is installed and tested, the library operates exactly as a PX500 Series with a SCSI host interface. Operation of the library via the operator control panel (OCP) is unchanged.
Introduction 3
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 C01 April 2006
Preparing for the FC1202 Installation 0
Before beginning the installation procedure, make sure that you have the required upgrade kit and tools.
Required Upgrade Kits 0 The FC1202 installation requires the following upgrade kit for every two tape
drives in a PX500 Series library (see table 1
Note: All part numbers are subject to change without notice.
):
Table 1 FC1202 Upgrade Kit PN PR-UU9CF-YF
Required Equipment (Customer Supplied)
Required Tools 0 The following tools are required to install the FC1202 bridge upgrade:
0
Qty Description
1 FC1202 PWA
2 SCSI Cables
1Ethernet cable
1Terminator
1 Quantum PX500 Series FC1202 Upgrade Instructions
A zonable Ethernet switch is required if multiple FC1202 Fibre Channel bridges are installed in either a PX506 or PX510 library. If a single FC1202 Fibre Channel bridge is installed, an Ethernet switch is not required.
#2 PHILLIPS® screwdriver
FC1202 Upgrade Procedure 0
The upgrade procedure is identical regardless of the number of FC1202s installed except where noted. The upgrade procedure consists of the following major steps:
Preparing the Quantum PX500 Series Library
Removing Tape Drive SCSI Jumper Cables
Installing the FC1202 Bridge
Installing the Ethernet Cables
Installing SCSI Jumper Cables
4 Preparing for the FC1202 Installation
Quantum PX500 Series FC1202 Upgrade Instructions
Configuring the FC1202 Bridge Software
81-81351-01 C01
April 2006
Preparing the Quantum PX500 Series Library
Figure 1 Operations Screen
To prepare the PX500 Series library:
0
Caution: Use appropriate ESD procedures when assembling and
installing the FC1202 option.
1 With the library turned on, press the
Operations screen (see figure 1).
Enter
Ops button on the OCP to access the
2 Select Library operations and press Enter. 3 From the library operations menu, select
Library on/offline and press Enter
to turn the library offline.
Figure 2 Turning On the Library
4 Verify that the OCP display indicates “Offline” from the
OCP screen.
5 Turn off the power button located on the front of the library (see figure 2
OCP
Power button
).
FC1202 Upgrade Procedure 5
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 C01 April 2006
Removing Tape Drive SCSI Jumper Cables
Figure 3 PX502 Cabling Configuration
Each pair of tape drives within the library are connected via a SCSI jumper
0
cable. These cables must be removed prior to cabling the FC1202.
1 Locate the SCSI jumper cables connecting each pair of tape drives in the
library and the host systems (see figure 3 and figure 5
for PX510). The tape drives are numbered 1 through 10
for PX502, figure 4 for PX506,
(depending on library model) starting in the top-left drive bay. Tape drive 1 is in the upper right-hand drive bay, tape drive 2 is in the upper left­hand drive bay, and so forth. Refer to the following illustrations for exact tape drive numbering.
Host computer
Tape drive 2 Tape drive 1
SCSI jumpers
6 FC1202 Upgrade Procedure
SCSI terminator
Figure 4 PX506 Cabling Configuration
Host computer
Quantum PX500 Series FC1202 Upgrade Instructions
Tape drive 2 Tape drive 1
81-81351-01 C01
April 2006
SCSI jumper
SCSI jumper
Host computer
SCSI jumper
Host computer
Tape drive 4
Tape drive 6
Tape drive 3
SCSI terminators
Tape drive 5
FC1202 Upgrade Procedure 7
Quantum PX500 Series FC1202 Upgrade Instructions 81-81351-01 C01 April 2006
Figure 5 PX510 Cabling Configuration
SCSI jumper
SCSI jumper
Tape drive 2 Tape drive 1
Host computer
Host computer
Host computer
Host computer
SCSI jumper
Host computer
Tape drive 4
Tape drive 6
Tape drive 8
Tape drive 10
Tape drive 3
Tape drive 5
Tape drive 7
Tape drive 9
SCSI terminators
SCSI jumper
SCSI terminators
2 Remove all SCSI jumper cables connecting each pair of tape drives and
8 FC1202 Upgrade Procedure
SCSI jumper
the host systems and also all terminators.
Quantum PX500 Series FC1202 Upgrade Instructions
81-81351-01 C01
April 2006
Installing the FC1202 Bridge
The number of FC1202 bridges required depends on the number of tape
0
drives installed in the library.
1 to 2 tape drives requires 1 FC1202
3 to 4 tape drives requires 2 FC1202 bridges (PX506 and PX510 only)
5 to 6 tape drives requires 3 FC1202 bridges (PX506 and PX510 only)
7 to 8 tape drives requires 4 FC1202 bridges (PX510 only)
9 to 10 tape drives requires 5 FC1202 bridges (PX510 only)
To install the FC1202 bridge:
1 Loosen the two PHILLIPS screws securing the blank off plate(s) to the
CPCI card cage and expose the number of slots needed for the FC1202 installation (one blank off plate per FC1202).
Note: Start the FC1202 installation in slot 1 of the CPCI card cage
(PX506 and PX510 only).
2 With the SCSI ports located to your right as you face the back of the
library, slide the first FC1202 into the slot of the card cage (see figure 6 PX502, figure 7
for PX506, and figure 8 for PX510).
for
Figure 6 Installing a FC1202 Bridge (PX502)
Blank off plate
Screws
Card cage
FC1202
FC1202 Upgrade Procedure 9
Loading...