Purpose of This Release
Pathlight VX 2.4.3 includes several resolved issues, support for EMC Flare Code 19/44, and updated drive
and library firmware levels. These notes also provide auxiliary firmware compatibility information. Visit
www.quantum.com
for additional information about Pathlight VX and previous releases.
New Features and Enhancements
The Pathlight VX 2.4.3 release addresses known issues . There are no new features or enhan cements. See
The 2.4.3 release enforces use of Quantum-approved SFPs in the SNC’s FC blades. If an FC blade uses
SFPs that are not approved, then these SFPs need to be replaced as part of the Pathlight VX software
upgrade. Use Table 3
to determine which SFPs are Quantum-approved for use in the SNC’s FC blades.
Table 3Supported SFPs for the FC Blade - P/N 1-00727-XX
This SFP model is supported with the exception of those manufactured in September or October 2004.
Note
This is current information as of the publication date of these Release Notes. To
determine the latest part numbers or other compatibility information, contact
Global Services
.
Resolved Issues
This release of Pathlight VX software resolved the following issues.
Pathlight VX management server detects only 8 LUNs on switchless systems
upgraded to Pathlight VX 2.4.1.
The vmc to vmcComm interface hangs, requiring a reboot.
Add support for Daylight Savings Time changes in 2007.
Quantum
CR 68104SR 621380Need to account for boundary conditions on EMC battery check.
CR 68146SR 624298With an AIX host, a message devices.fcp.array error occurs when cfgmgr is run.
(This issue was corrected by disabling command and control.)
CR 68187SR 627704Add support for ssh 3.7.1 to Pathlight VX.
CR 50669SR 453404When the utility module reboots due to
power fluctuations, the Pathlight VX
goes down. Need to improve the utility
module power glitch tolerance so it will
stay up like management server and FC
switch for certain power fluctuations.
CR 51219SR 470948Export failed due to prevent media
removal set in a Scalar i2000 library.
CR 52085N/APossible Java errors with Microsoft
patches for Windows XP that became
available on December 13, 2005.
CR 53355N/AData Protector cannot move virtual
media from the I/E station. The error
reported is “medium removal
prevented.”
CR 53878SR 487516
SR 492106
CR 53911N/ADisk Extension media may be reported
In certain conditions the physical library
might increase the chance of seeing an
out of memory condition.
as unavailable even though the suspect
count is zero and data is “available.”
Provide regulated, consistent voltage to
the Pathlight VX. There should be no
spikes in the power supply.
Reboot the i2000 library.
Taking the December 13, 2005 patches
is not recommended.
Wait until the physical import of the
media is complete (Admin Alert
appears). Alternatively, check the
Media Tracking Report. Navigate to
Reports > Media Tracking on the
Pathlight VX User Interface.
Reboot the Pathlight VX.
Contact Quantum Global Services.
CR 57667SR 525020There may be no backend library activity
after upgrading from 2.3 to 2.4, build 13.
CR 62426SR 560720
SR 563082
CR 63104N/AWhen upgrading from Pathlight VX 2.3,
CR 63770SR 509952
SR 524872
CR 66984SR 611880The MSM process ArcDisp terminates
Import operation during Export function
does not work, error “port in use.”