Quantum NDX Series User Manual

User’s Guide
Quantum NDX NAS 1U Rack
6-67445-01 Rev A
ii Quantum NDX NAS 1U Rack User’s Guide
Quantum NDX NAS 1U Rack User’s Guide, 6-67445-01 Rev A, October 2011, Product of USA.
COPYRIGHT STATEMENT
© 2011 Quantum Corporation. All rights reserved.
Your right to copy this manual is limited by copyright law. Making copies or adaptations without prior written authorization of Quantum Corporation is prohibited by law and constitutes a punishable violation of the law.
TRADEMARK STATEMENT
Quantum, the Quantum logo, DLT, DLTtape, the DLTtape logo, SuperLoader, Scalar, StorNext, and DXi are registered trademarks of Quantum Corporation, registered in the U.S. and other countries.
Preserving the World's Most Important Data. Yours., Backup. Recovery. Archive. It’s What We Do., the DLT logo, DLTSage, Dynamic Powerdown, FastSense, FlexLink, GoVault, MediaShield, Optyon, Pocket­sized. Well-armored, SDLT, SiteCare, SmartVerify, StorageCare, Super DLTtape, and Vision are trademarks of Quantum.
LTO and Ultrium are trademarks of HP, IBM, and Quantum in the U.S. and other countries. All other trademarks are the property of their respective companies.
Specifications are subject to change without notice.
Quantum NDX NAS 1U Rack User’s Guide iii
Contents
Preface ix
Chapter 1 Introduction 1
Motherboard Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Serial ATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
I/O Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Graphics Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Server Chassis Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
System Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SATA Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Rear I/O Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Chapter 2 System Safety 5
Electrical Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
General Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ESD Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Contents
iv Quantum NDX NAS 1U Rack User’s Guide
Operating Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chapter 3 Server Installation 11
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Unpacking the System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Preparing for Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Choosing a Setup Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Warnings and Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Rack Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Server Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Rack Mounting Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ambient Operating Temperature . . . . . . . . . . . . . . . . . . . . . . 14
Reduced Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Mechanical Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Circuit Overloading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Reliable Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Installing the System into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Identifying the Sections of the Rack Rails . . . . . . . . . . . . . . . . 15
Installing the Rear Inner Rails . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installing the Rack Rails. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Installing the Server into a Telco Rack. . . . . . . . . . . . . . . . . . . 18
Installing Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installing DIMMs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Memory Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Adding PCI Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
PCI Expansion Slots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
PCI Card Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
PCI Slot/Card
Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Chapter 4 Initial Setup and System Interface 23
Initial Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
First Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Connecting to Ethernet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Contents
Quantum NDX NAS 1U Rack User’s Guide v
Control Panel Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Control Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Hard Drive Carrier LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Chapter 5 Advanced Chassis Setup 29
I/O Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
.System Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
System Fan Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SATA Drive Replacement and Installation . . . . . . . . . . . . . . . . . . . . . . 31
Accessing the Drive Bays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Mounting a Drive in a Drive Carrier. . . . . . . . . . . . . . . . . . . . . 31
Installing/Removing SATA Drives. . . . . . . . . . . . . . . . . . . . . . . 32
DVD-ROM Drive Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Removing the Chassis Cover . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Removing/Installing a Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Power Supply Failure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Appendix A BIOS Error Beep Codes 35
Appendix B System Specifications 37
Contents
vi Quantum NDX NAS 1U Rack User’s Guide
Quantum NDX NAS 1U Rack User’s Guide vii
Figures
Figure 1 Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Figure 2 Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 3 Installing the Onboard Battery . . . . . . . . . . . . . . . . . . . . . . 9
Figure 4 Installing the Rear Inner Chassis . . . . . . . . . . . . . . . . . . . . 16
Figure 5 Installing the Server into a Rack (with optional front bezel
shown)17
Figure 6 Installing the Server into a Telco Rack (with optional front
bezel shown)18
Figure 7 Installing DIMM into Slot . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 8 I/O Ports Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 9 Mounting Drive in Carrier . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figures
viii Quantum NDX NAS 1U Rack User’s Guide
Quantum NDX NAS 1U Rack User’s Guide ix
Preface
This manual introduces the Quantum NDX NAS 1U Rack. This preface includes:
• About This Manual
• Document Organization
• Notational Conventions
• Product Safety Statements
• Contacts
• Worldwide End-User Product Warranty
About this Manual This manual provides information for the installation and use of the
Quantum NDX NAS 1U Rack chassis. Please read this manual before performing installation or maintenance.
The Quantum NDX NAS 1U Rack chassis features 4 enterprise class hard disk drives, Intel Core i3 Processor and 4GB of RAM. The chassis is equipped with a high-efficiency power supply for superb power savings.
This document lists compatible parts available when this document was published. Always refer to the our Web site for updates on supported parts and configurations.
Preface
x Quantum NDX NAS 1U Rack User’s Guide
Document Organization Following is a brief description of chapter contents.
• Chapter 1 Introduction provides a checklist of the main features of the Quantum NDX NAS 1U Rack.
• Chapter 2 System Safety lists warnings, precautions, and system safety. It recommended that you thoroughly familiarize yourself with all safety precautions.
• Chapter 3 provides setup instructions to get your system up and running, and provides procedures for upgrading system memory,
• Chapter 4 System Interface provides interface details on the system interface, which includes the functions and information provided by the control panel on the tower as well as other LEDs located throughout the system.
• Chapter 5 Advanced Chassis Setup covers the steps required to install components and perform maintenance on the Quantum NDX NAS 1U Rack chassis.
• Appendix A: BIOS Error Beep Codes
• Appendix B: System Specifications
Notational Conventions This manual uses the following conventions:
Convention Example
User input is shown in bold font. ./DARTinstall
Computer output and command line examples are shown in monospace font.
./DARTinstall
User input variables are enclosed in angle brackets.
http://<ip_address>/cgi-bin/ stats
For UNIX and Linux commands, the command prompt is implied.
./DARTinstall isthesameas #./DARTinstall
Preface
Quantum NDX NAS 1U Rack User’s Guide xi
The following formats indicate important information:
Note: Note emphasizes important information related to the main
topic.
Caution: Caution indicates potential hazards to equipment or data.
WARNING: Warning indicates potential hazards to personal safety.
• Right side of the system — Refers to the right side as you face the component being described.
• Left side of the system — Refers to the left side as you face the component being described.
•b — All binary numbers are succeeded by “b.”
•h — All hexadecimal numbers are succeeded by “h.”
• Error or attention conditions are represented in parenthesis that translate as follows:
(SK=S ASC=AA ASCQ=QQ)
where:
S — hexadecimal sense key value
AA — hexadecimal additional sense code
QQ — hexadecimal additional sense code qualifiers
File and directory names, menu commands, button names, and window names are shown in bold font.
/data/upload
Menu names separated by arrows indicate a sequence of menus to be navigated.
Utilities > Firmware
Convention Example
Preface
xii Quantum NDX NAS 1U Rack User’s Guide
Product Safety Statements
Quantum will not be held liable for damage arising from unauthorized use of the product. The user assumes all risk in this aspect.
This unit is engineered and manufactured to meet all safety and reg
ulatory requirements. Be aware that improper use may result in bodily injury, damage to the equipment, or interference with other equipment.
WARNING: Before operating this product, read all instructions and
warnings in this document and in the system, safety, and regulatory guide.
Preface
Quantum NDX NAS 1U Rack User’s Guide xiii
Contacts Visit the Quantum home page at:
http://www.quantum.com
Getting More Information or Help
StorageCare™, Quantum’s comprehensive service approach, leverages advanced data access and diagnostics technologies with cross­environment, multi-vendor expertise to resolve backup issues faster and at lower cost.
Preface
xiv Quantum NDX NAS 1U Rack User’s Guide
Accelerate service issue resolution with these exclusive Quantum StorageCare services:
Servic
e and Support Web site - Register products, license
software, browse Quantum Learning courses, check backup software and operating system support, and locate manuals, FAQs, firmware downloads, product updates and more in one convenient location. Benefit today at:
http://www.quantum.com/ServiceandSupport/Index.aspx
eSupport - Submit online service requests, update contact
information, add attachments, and receive status updates via e­mail. Online Service accounts are free from Quantum. That account can also be used to access Quantum’s Knowledge Base, a comprehensive repository of product support information. Sign up today at:
http://www.quantum.com/osr
For further assistance, or if training is desired, contact the Quantum Customer Support Center:
United States 800-284-5101 (toll free)
949-725-2100
EMEA 00800-4-782-6886 (toll free)
+49 6131 3241 1164
APAC +800 7826 8887 (toll free)
+603 7953 3010
For worldwide support:
http://www.quantum.com/ServiceandSupport/Index.aspx
Worldwide End-User Product Warranty
For more information on the Quantum Worldwide End-User Standard Limited Product Warranty:
http://www.quantum.com/pdf/QuantumWarranty.pdf
Quantum NDX NAS 1U Rack User’s Guide 1
Chapter 1
Introduction
The Quantum NDX NAS 1U Rack features is a high-end server comprised of two main subsystems: the server chassis and the single processor motherboard.
In addition to the motherboard and chassis, various hardware components are included, as listed below:
• Four sets of 4-cm counter-rotating fans
• One air shroud
• One passive CPU heatsink
• One riser card for one add-on card
• SATA Accessories
•One SATA backplane
• Four hard drive carriers
• One rackmount kit
Chapter 1: Introduction Motherboard Features
2 Quantum NDX NAS 1U Rack User’s Guide
Motherboard Features
Memory The motherboard four DIMM sockets that can support up to 32 GB of
unbuffered DDR3-1333/1066 memory. Refer to Chapter 3 for installing memory.
Serial ATA An on-chip SATA controller is integrated into the motherboard to
provide a six-port, 3 Gb/sec Serial ATA subsystem, which is RAID 0, 1, 5 and 10 supported (RAID 5 supported with Windows OS only). The SATA drives are hot-swappable units.
I/O Ports The color-coded I/O ports include one COM port, a VGA (monitor) port,
two USB 2.0 ports, PS/2 mouse and keyboard ports and two gigabit Ethernet ports. A dedicated IPMI LAN port is also included.
Graphics Controller The motherboard features an integrated ATI video controller based on
the Matrox G200eW graphics chip, which has 16 MB of DDR2 memory.
Server Chassis Features
Figure 1 Chassis Front View
USB Ports
SATA Drives (4)
COM2 Port Control Panel
Chapter 1: Introduction
Server Chassis Features
Quantum NDX NAS 1U Rack User’s Guide 3
Figure 2 Chassis Rear View
PCI Expansion SlotPower Supply*
Keyboard Port
USB Ports COM1 Port Ethernet Ports
Dedicated IPMI Port
Mouse Port
VGA Port
*The 5017C-MTRF includes two power supplies for redundancy.
The following is a general outline of the main features of the chassis.
System Power The chassis includes a single 350W power supply.
SATA Subsystem The chassis was designed to support four SATA hard drives, which are
hot-swappable units.
Control Panel The control panel provides important system monitoring and control
information. LEDs indicate power on, network activity, hard disk drive activity and system overheat conditions. The control panel also includes a main power button and a system reset button. The front also includes a COM port and two USB serial ports for easy access.
Chapter 1: Introduction Server Chassis Features
4 Quantum NDX NAS 1U Rack User’s Guide
Rear I/O Panel The rackmount chassis I/O panel provides one PCI motherboard
expansion slot, one COM port (another is internal), two USB ports, a parallel (printer) port, PS/2 mouse and keyboard ports, a VGA port and two Gb Ethernet ports.
Cooling System The chassis has an innovative cooling design that features four 4-cm
high-performance system cooling fans and an air shroud. Each of these fans plug into a chassis fan header on the motherboard. An air shroud channels the air flow generated by the fans to efficiently cool the processor area of the system.
Quantum NDX NAS 1U Rack User’s Guide 5
Chapter 2
System Safety
This chapter provides information on warnings, precautions, and system safety.
Important: Please thoroughly familiarize yourself with all safety
precautions.
Electrical Safety Precautions
Basic electrical safety precautions should be followed to protect yourself from harm and the Quantum NDX NAS 1U Rack from damage:
Chapter 2: System Safety Electrical Safety Precautions
6 Quantum NDX NAS 1U Rack User’s Guide
• Be aware of the locations of the power on/off switch on the chassis as well as the room’s emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system.
• Do not work alone when working with high-voltage components.•
• Power should always be disconnected from the system when removing or installing main system components, such as the server board, memory modules or option peripherals like a DVD-ROM (not necessary for hot swappable drives). When disconnecting power, you should first power down the system with the operating system and then unplug the power cords from all the power supply modules in the system.
• When working around exposed electrical circuits, another person who is familiar with the power-off controls should be nearby to switch off the power, if necessary.
• Use only one hand when working with powered-on electrical equipment. This is to avoid making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with.
• Do not use mats designed to decrease electrostatic discharge as protection from electrical shock. Instead, use rubber mats that have been specifically designed as electrical insulators.
• The power supply power cord must include a grounding plug and must be plugged into grounded electrical outlets.
• This product may be connected to an IT power system. In all cases, make sure that the unit is also reliably connected to Earth (ground).
• Server board battery:
Caution: There is a danger of explosion if the onboard battery is
installed upside down, which will reverse its polarities This battery must be replaced only with the same or an equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
Chapter 2: System Safety
General Safety Precautions
Quantum NDX NAS 1U Rack User’s Guide 7
• Mainboard replaceable soldered-in fuses: Self-resetting PTC (Positive Temperature Coefficient fuses on the mainboard must be replaced by trained service technicians only. The new fuse must be the same or equivalent as the one replaced. Contact technical support for details and support.
General Safety Precautions
• Keep the area around the Quantum NDX NAS 1U Rack clean and free of clutter.
• The Quantum NDX NAS 1U Rack weighs approximately 38 lbs (~17.3 kg) when fully loaded. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight. Always keep your back straight and lift with your legs.
• Place the chassis top cover and any system components that have been removed away from the system or on a table so that they won't accidentally be stepped on.
• While working on the system, do not wear loose clothing such as neckties and unbuttoned shirt sleeves, which can come into contact with electrical circuits or be pulled into a cooling fan.
• Remove any jewelry or metal objects from your body, which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present.
• After accessing the inside of the system, close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made.
Chapter 2: System Safety ESD Precautions
8 Quantum NDX NAS 1U Rack User’s Guide
ESD Precautions
Electrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic components and printed circuit boards. The following measures are generally sufficient to neutralize this difference
before
contact is made to protect your equipment from ESD:
• Use a grounded wrist strap designed to prevent static discharge.
• Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use.
• Touch a grounded metal object before removing the board from the antistatic bag.
• Do not let components or PCBs come into contact with your clothing, which may retain a charge even if you are wearing a wrist strap.
• Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or contacts.
• When handling chips or modules, avoid touching their pins.
• Put the serverboard and peripherals back into their antistatic bags when not in use.
• For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the serverboard.
Operating Precautions
Care must be taken to assure that the chassis cover is in place when the Quantum NDX NAS 1U Rack is operating to assure proper cooling. Out of warranty damage to the system can occur if this practice is not strictly followed.
Chapter 2: System Safety
Operating Precautions
Quantum NDX NAS 1U Rack User’s Guide 9
Figure 3 Installing the Onboard Battery
LITHIUM BATTERY
BATTERY HOLDER
WARNING: Handle used batteries carefully. Do not damage the
battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly.
Chapter 2: System Safety Operating Precautions
10 Quantum NDX NAS 1U Rack User’s Guide
Quantum NDX NAS 1U Rack User’s Guide 11
Chapter 3
Server Installation
Overview
This chapter provides a quick setup checklist to get the Quantum NDX NAS 1U Rack up and running. Following the steps in order given should enable you to have your system setup and operational within a minimal amount of time. This quick set up assumes that you are an experienced computer user familiar with common concepts and terminology.
Unpacking the System
You should inspect the box the Quantum NDX NAS 1U Rack was shipped in and note if it was damaged in any way. If the server itself shows damage, you should submit a damage claim with the carrier who delivered it.
Chapter 3: Server Installation Preparing for Setup
12 Quantum NDX NAS 1U Rack User’s Guide
Decide on a suitable location for the rack unit that will hold the Quantum NDX NAS 1U Rack. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet. Read the
Warnings and Precautions on
page 13.
Preparing for Setup
The box the Quantum NDX NAS 1U Rack was shipped in should include two sets of rail assemblies, six rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimal amount of time.
Important: Read this section in its entirety before you begin the
installation procedure outlined in the sections that follow.
Choosing a Setup Location
• Leave enough clearance in front of the rack to enable you to open the front door completely (-25 inches) and approximately 30 inches of clearance in the back of the rack to allow for sufficient air flow and ease in servicing.This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
• This product is not suitable for use with visual display work place devices according to §2 of the German Ordinance for Work with Visual Display Units.
Chapter 3: Server Installation
Warnings and Precautions
Quantum NDX NAS 1U Rack User’s Guide 13
Warnings and Precautions
Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are fully
extended to the floor with the full weight of the rack resting on them.
• In single rack installation, stabilizers should be attached to the rack. In multiple rack installations, the racks should be coupled together.
• Always make sure the rack is stable before extending a component from the rack.
• Extend only one component at a time - extending two or more simultaneously may cause the rack to become unstable.
Server Precautions • Review the electrical and general safety precautions in Chapter 2
System Safety.
• Determine the placement of each component in the rack before you install the rails.
• Install the heaviest server components on the bottom of the rack first, and then work up.
• Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure.
• Allow the hot plug SATA drives and power supply modules to cool before touching them.
• Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling.
Chapter 3: Server Installation Rack Mounting Considerations
14 Quantum NDX NAS 1U Rack User’s Guide
Rack Mounting Considerations
Ambient Operating Te mp era tu r e
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airflow Equipment should be mounted into a rack so that the amount of air
flow required for safe operation is not compromised.
Mechanical Loading Equipment should be mounted into a rack so that a hazardous
condition does not arise due to uneven mechanical loading.
Circuit Overloading Consideration should be given to the connection of the equipment to
the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground A reliable ground must be maintained at all times. To ensure this, the
rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
Chapter 3: Server Installation
Installing the System into a Rack
Quantum NDX NAS 1U Rack User’s Guide 15
Installing the System into a Rack
This section provides information on installing the Quantum NDX NAS 1U Rack into a rack unit with the rack rails provided.
There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You may have received rack rail hardware with the Quantum NDX NAS 1U Rack. (Two front inner rails should already be attached to the chassis.) This hardware consists of two rear inner rails that secure to the chassis, one on each side just behind the pre installed front inner rails. Note that these two rails are left/ right specific.
Installing the Rear Inner Rails
First, locate the right rear inner rail (the rail that will be used on the right side of the chassis when you face the front of the chassis). Align the two square holes on the rail against the hooks on the right side of the chassis. Securely attach the rail to the chassis with M4 at head screws. Repeat these steps to install the left rear inner rail to the left side of the chassis (see
Figure 4). You will also need to attach the rail
brackets when installing into a telco rack.
Locking Tabs: Both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
Chapter 3: Server Installation Installing the System into a Rack
16 Quantum NDX NAS 1U Rack User’s Guide
Figure 4 Installing the Rear Inner Chassis
Installing the Rack Rails Determine where you want to place the NDX 1U NAS in the rack (see
Warnings and Precautions on page 13. Position the chassis rail guides at
the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assem
bly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure that both are at the exact same height and with the rail guides facing inward.
Chapter 3: Server Installation
Installing the System into a Rack
Quantum NDX NAS 1U Rack User’s Guide 17
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure
5
on page 17.
When the server has been pushe
d completely into the rack, you should
hear the locking tabs “click”.
Figure 5 Installing the Server into a Rack (with optional front bezel shown)
Chapter 3: Server Installation Installing the System into a Rack
18 Quantum NDX NAS 1U Rack User’s Guide
Installing the Server into a Telco Rack
To install the Quantum NDX NAS 1U Rack into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the rack. Finish by sliding the chassis into the rack and tightening the brackets to the rack.
Figure 6 Installing the Server into a Telco Rack (with optional front bezel shown)
Chapter 3: Server Installation
Installing Memory
Quantum NDX NAS 1U Rack User’s Guide 19
Installing Memory
Caution: Exercise extreme care when installing or removing DIMM
modules to prevent any possible damage.
Installing DIMMs 1 Insert the desired number of DIMMs into the memory slots, starting
with slots 1. DIMM1A. Pay attention to the notch along the bottom of the module to pre-vent inserting the DIMM module incorrectly. See
Figure 7 on page 20.
2 Gently press down on the DIMM module until it snaps into place in
the slot. Repeat step 1 to install to DIMM1B if needed.
Memory Support
The NDX NAS supports up to 32GB of ECC unbuffered (UDIMM) DDR3­1333/1066 memory in four memory slots. Populating these slots with a pair of memory modules of the same type and same size will result in interleaved memory, which will improve memory performance. Please refer to the table below:
DDR3 Unbuffered ECC (UDIMM) Memory
DIMM Slots
per Channel
DIMMs
Populated per
Channel
DIMM Type POR Speeds Ranks per DIMM
(any combination)
2 1 Unbuered
DDR3
1066, 1333 Single Rank, Dual
Rank
2 2 Unbuered
DDR3
1066, 1333 Single Rank, Dual
Rank
Slot 1, Channel 1
Slot 1, Channel 2
(Blue Slot)
Slot 2, Channel 2
(Blue Slot)
Slot 2, Channel 1
Chapter 3: Server Installation Memory Support
20 Quantum NDX NAS 1U Rack User’s Guide
Figure 7 Installing DIMM into Slot
To I n s t all: Insert module vertically and press down until it snaps into place. Pay attention to the alignment notch at the bottom.
To Remove:
Use your thumbs to gently push the release tabs near both ends of the module. This should release it from the slot.
Top View of DDR3 Slot
Release Tab
Release Tab
Note: Notch should align with the receptive key point on the slot.
Notch
Notch
Front View
Chapter 3: Server Installation
Adding PCI Cards
Quantum NDX NAS 1U Rack User’s Guide 21
Adding PCI Cards
PCI Expansion Slots The chassis can accommodate one standard size (full height full length)
PCI expansion card. When viewed from the chassis front, the card installs to the left rear of the system.
PCI Card Installation Before installing a PCI add-on card, make sure it is supported by the riser
card. Begin by releasing the locking tab that corresponds to the slot you wish to populate. Insert the expansion card into the riser card by pushing down with your thumbs evenly on both sides of the card.
PCI Slot/Card Configurations
Riser Card Expansion card supported
Pre-installed 1x PCI-E 2.0 x8 card
Chapter 3: Server Installation Adding PCI Cards
22 Quantum NDX NAS 1U Rack User’s Guide
Quantum NDX NAS 1U Rack User’s Guide 23
Chapter 4
Initial Setup and System
Interface
This chapter describes activities required for initial setup, provides a hardware overview, and describes control panel buttons and control panel and hard drive carrier LEDs.
Initial Setup
First Use When you first use the Quantum NDX NAS 1U Rack, connect the unit to
a keyboard, monitor, and mouse, and proceed with several Microsoft Windows setup wizards. This is a requirement for initial setup only.
Connecting to Ethernet The Quantum NDX NAS 1U Rack comes with three RJ45 ports (see
Figure 1 and Figure 2 on page 3. Two are ethernet ports positioned
together. Connect the NDX NAS to your network using these two ports.
The third RJ45 port is for IPMI (Intelligent Platform Management Interface). This port is used or system monitoring, troubleshooting and technical support.
Chapter 4: Initial Setup and System Interface Hardware Overview
24 Quantum NDX NAS 1U Rack User’s Guide
Hardware Overview
There are several LEDs on the control panel as well as others on the hard drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components. There are also two buttons on the chassis control panel and an on/off switch on the power supply. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
Control Panel Buttons
There are two push-buttons located on the front of the chassis. These are (in order from left to right) a reset button and a power on/off button.
Reset: The reset button is used to reboot the system.
Power: This is the main power button, which is used to apply or
turn off the main system power. Turning off system power with this button removes the main power but keeps standby power supplied to the system.
Chapter 4: Initial Setup and System Interface
Control Panel LEDs
Quantum NDX NAS 1U Rack User’s Guide 25
Control Panel LEDs
The control panel located on the front of the chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
Overheat / Fan Fail
When this LED flashes, it indicates a fan failure. When on continuously it in
dicates an overheat condition, which may be caused by cables obstructing the air ow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly. This LED will remain flashing or on as long as the indicated condition exists.
NIC2
Indicates network activity on LAN2 when flashing.
Chapter 4: Initial Setup and System Interface Control Panel LEDs
26 Quantum NDX NAS 1U Rack User’s Guide
NIC1
Indicates network activity on LAN1 when flashing.
HDD
Channel activity for all HDDs. This light indicates DVD-ROM/hard drive activity when flashing.
Power
Indicates power is being supplied
to the system's power supply units.
This LED should normally be illuminated when the system is operating.
Chapter 4: Initial Setup and System Interface
Hard Drive Carrier LEDs
Quantum NDX NAS 1U Rack User’s Guide 27
Hard Drive Carrier LEDs
Each drive carrier has two LEDs.
Green: When illuminated, the green LED on the drive carrier indicates drive activity. A connection to the backplane enables this LED to blink on and off when that particular drive is being accessed.
Red: The red LED to indicate a drive failure. If one of the drives fails, refer to
Removing/Installing a Drive on page 33 for instructions on
replacing failed drives.
Chapter 4: Initial Setup and System Interface Hard Drive Carrier LEDs
28 Quantum NDX NAS 1U Rack User’s Guide
Quantum NDX NAS 1U Rack User’s Guide 29
Chapter 5
Advanced Chassis Setup
This chapter covers the steps required to install components and perform maintenance on the Quantum NDX NAS 1U Rack chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
Too ls Re qu ir ed : The only tool you will need to install components and perform maintenance is a Phillips screwdriver.
I/O Ports
The I/O ports are color coded in conformance with the PC 99 specification. See
Figure 8 on page 30 below for the colors and
locations of the various I/O ports.
Chapter 5: Advanced Chassis Setup .System Fans
30 Quantum NDX NAS 1U Rack User’s Guide
Figure 8 I/O Ports Diagram
1
2
3
4
5
6 7 8 9
Backplane I/O Ports
1. Keyboard (Purple) 6. COM 1
2. PS/2 Mouse (Green) 7. VGA
3. USB Port 0 8. LAN1
4. USB Port 1 9. LAN2
5. IPMI LAN
.System Fans
Four 4-cm high-performance fans provide the cooling for the Quantum NDX NAS 1U Rack. The chassis includes air seals under the fans and at the chassis cross section, which separates the drive bay area from the serverboard area of the chassis to promote better air flow. It is important that the air seal is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis.
The fans can adjust their speed according to the heat
level sensed in the
system, which results in more efficient and quieter fan operation.
Chapter 5: Advanced Chassis Setup
SATA Drive Replacement and Installation
Quantum NDX NAS 1U Rack User’s Guide 31
System Fan Failure If a fan fails, you will need to have it replaced with the same type.
Contact Quantum for information on replacement fans.
SATA Drive Replacement and Installation
Accessing the Drive Bays
SATA Drives: Because of their hotswap capability, you do not need to
access the inside of the chassis or power down the system to install or replace SATA drives. Proceed to the next step for instructions.
Caution: Use caution when working around the SATA backplane. Do
not touch the backplane with any metal objects and make sure no ribbon cables touch the backplane. Also, regardless of how many drives are installed, all four drive carriers must remain in the chassis to maintain proper air flow.
Caution: Enterprise level hard disk drives are recommended for use
in Quantum chassis and servers.
Mounting a Drive in a Drive Carrier
The SATA drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper air flow for the system. For this reason, even empty carriers without drives installed must remain in the chassis.
1 Install a new drive into the carrier with the printed circuit board side
facing down so that the mounting holes align with those in the carrier.
2 Secure the drive to the carrier with six screws, as shown in Figure 9.
Chapter 5: Advanced Chassis Setup DVD-ROM Drive Installation
32 Quantum NDX NAS 1U Rack User’s Guide
Installing/Removing SATA Drives
1 To remove a carrier, push the release button located beside the drive
LEDs.
2 Swing the
colored handle fully out and use it to pull the unit
straight out.
Figure 9 Mounting Drive in Carrier
DVD-ROM Drive Installation
The top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay. The Quantum NDX NAS 1U Rack accommodates only slim DVD-ROM drives. Side mounting brackets are needed to mount a slim DVD-ROM drive into the server.
WARNING: You must power down the system before installing or
removing a DVD-ROM drive.
Chapter 5: Advanced Chassis Setup
Power Supply
Quantum NDX NAS 1U Rack User’s Guide 33
Removing the Chassis Cover
1 Grasp the two handles on either side and pull the unit straight out
until it locks (you will hear a “click”).
2 Depress the two buttons on the top of the chassis to release the top
cover and at the same time, push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server.
Removing/Installing a Drive
1 With the chassis cover removed, unplug the power and data cables
from the drive.
2 Locate the locking tab at the rear of the drive. It will be on the left
side of the drive when viewed from the front of the chassis.
3 Pull the tab away from the drive and push the drive unit out the
front of the chassis.
4 Add a new drive by following this procedure in reverse order. You
may hear a faint *click* of the locking tab when the drive is fully inserted.
5 Remember to reconnect the data and power cables to the drive
before replacing the chassis cover and restoring power to the system.
Power Supply
The Quantum NDX NAS 1U Rack has a single 350 watt power supply. This power supply has the capability of operating at 100 - 240 input volts. Depress the main power button on the front of the chassis and then unplug the AC power cord to completely remove power from the system before removing the power supply.
Power Supply Failure If the power supply unit fails, the system will shut down and you will
need to replace the power supply unit. Replacement units can be ordered directly from Quantum (see contact information in the Preface).
Chapter 5: Advanced Chassis Setup Power Supply
34 Quantum NDX NAS 1U Rack User’s Guide
Replacing the Power Supply
To replace a power supply, you must first remove the top chassis cover. Follow the procedure on the previous page.
1 Unplug the power cord from the system.
2 To remove the failed power unit, remove the two screws on the back
of the power supply, which secure it to the chassis. You can then lift the unit straight out of the chassis.
3 Replace the failed unit with another unit of the same wattage. It is
highly recommended to replace it with the exact same power supply.
4 Carefully insert the new unit into position in the chassis and secure
it with the two screws at the rear of the unit.
5 Before reconnecting the power cord, make sure the power switch
on the power supply is in the off position. Then reconnect the power cord, replace the chassis top cover and push the unit back into the rack.
6 Finish by turning the power switch on the power supply on, and
then depress the power button on the front of the system.
Quantum NDX NAS 1U Rack User’s Guide 35
Appendix A
BIOS Error Beep Codes
During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue with bootup. The error messages normally appear on the screen.
Fatal errors will not allow the system to continue to bootup. If a fatal error occurs, you should consult with your system manufacturer for possible repairs.
These fatal errors are usually communicated through a series of audible beeps. The numbers on the fatal error list correspond to the number of beeps for the corresponding error.
BIOS Error Beep Codes
Beep Code/LED Error Message Description
1 beep Refresh Circuits have been reset.
(Ready to power up)
5 short beeps + 1 long beep
Memory error No memory detected in the
system
8 beeps Display memory
read/write error
Video adapter missing or with faulty memory
OH LED On System OH System Overheat
:
36 Quantum NDX NAS 1U Rack User’s Guide
Quantum NDX NAS 1U Rack User’s Guide 37
Appendix B
System Specifications
Processors
Single Intel® processor in an LGA1155 socket
Chipset
Intel Core i3
BIOS
64 Mb SPI AMI® Flash
Memory Capacity
Four DIMM sockets supporting up to 32 GB of unbuffered DDR3-1333/ 1066 memory
SATA Controller
Intel on-chip controller for six-port Serial ATA, RAID 0, 1 5 and 10 supported (RAID 5 not supported with Linux OS, Windows only)
:
38 Quantum NDX NAS 1U Rack User’s Guide
SATA Drive Bays
Four hot-swap drive bays to house four SATA or hard drives
Peripheral Drive Bays
Suitable for one slim DVD ROM drive (not included)
Expansion Slots
Riser card for one PCI-E 2.0 x8 add-on card
Chassis
Form Factor: 1U rackmount
Dimensions: (WxHxD) 17.2 x 1.7 x 19.85 in. (437 x 43 x 504 mm)
Weight
Gross Weight: 38 lbs. (17.3 kg.)
System Cooling
Four 4-cm high performance fans
One air shroud
System Input Requirements
AC Input Voltage: 100-240V AC auto-range
Rated Input Current: 4.2A (100V) to 1.8A (240V)
Rated Input Frequency: 50 to 60 Hz
Power Supply
Rated Output Power: 350W (Part# PWS-351-1H)
Rated Output Voltages: +3.3V (15A), +5V (18A), +12V (29A), -12V (.5A),
:
Quantum NDX NAS 1U Rack User’s Guide 39
+5Vsb (3A)
5017C-MTRF:
Rated Output Power: 400W (Part# PWS-351-1H)
Rated Output Voltages: +3.3V (15A), +5V (18A), +12V (29A), -12V (.5A),
+5Vsb (3A)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV Certified (Germany), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
: