Quantum DX5000, DX3000 Quick Start Guide

DX3000 and DX5000
Quick Start Guide
TABLE OF CONTENTS
Introduction .......................................1
Notational Conventions .................1
Choosing a Location ..........................2
Rack Space Requirements...............2
Environmental Conditions .............2
Providing Necessary Tools..............2
Taking ESD Precautions ..................2
Unpacking the DX3000/DX5000.........2
Installing the DX3000/DX5000 System3
Locating the Mounting Position ....3
Installing the DX3000/DX5000
Chassis ............................................. 4
Cabling the DX3000/DX5000..............7
Cabling a DX3000 System...............7
Cabling a DX5000 System...............8
Initial Configuration .......................... 8

Introduction 0

This quick start guides provides basic installation and configuration instructions for both the DX3000 and DX5000 systems (see figure 1). For more information, see
Quantum DX3000 and DX5000 User’s Guide
the provided with your DX3000 or DX5000 system.

Notational Conventions 0

This instruction uses the following conventions:
NOTE: Notes emphasize important information related to the main topic.
AUTION: Cautions indicate potential hazards to equipment and are included
C
to prevent damage to equipment.
ARNING: Warnings indicate potential hazards to personal safety and are
W
included to prevent injury.
on the documentation CD
Figure 1 PX3000 and DX5000
DX3000 and DX5000 Quick Start Guide

Choosing a Location 0

The DX3000/DX5000 must be installed in a restricted access location per specification EN69050-1. This system must only be installed by qualified IT service personnel. This is required to prevent untrained personnel from allowing body parts or electrically conductive items to penetrate into the interior of the system when replacing or installing drives, fans, and power supplies.
When choosing an installation site for the DX3000/DX5000 system, consider the following requirements:

Rack Space Requirements

Environmental Conditions

Rack Space Requirements 0
Ta b l e 1 contains the rack requirements for both the DX3000
and DX5000.
Table 1 Rack Requirements
DX3000 DX5000
Depth 27 in (68.6 cm) 25.4 in (64.5 cm)
Width 19 in (48.3 cm) 19 in (48.3 cm)
Height 3.5 in (8.9 cm),
2U
Weight 50 lbs (22.68 kg) 122 (55.34 kg)
Air Clearance
Environmental Conditions 0
Open 4 in (10.2 cm) behind unit for proper
8.75 (22.2 cm), 5U
air flow

Preparing for the Installation 0

Before you begin the installation procedure in this section, make the following preparations as described in this section:
Providing Necessary Tools

Taking ESD Precautions

Providing Necessary Tools 0

Provide the following tools for unpacking and installing the DX3000 and DX5000 systems:
#1 PHILLIPS® screwdriver
#2 PHILLIPS screwdriver
#1 Flat head screwdriver
Antistatic wrist strap included in accessory kit
Tak i n g E S D P r e c a u t i o n s 0
Some components within the DX3000 and DX5000 systems contain static-sensitive parts. To avoid damaging these parts while performing installation procedures, always observe the following precautions:
Keep the DX3000/DX5000 system turned off during all installation procedures.
Use an antistatic wrist strap (included in the accessory kit).
Keep static-sensitive parts in their original shipping containers until ready for installation.
Do not place static-sensitive parts on a metal surface. Place them inside their protective shipping bag or on an antistatic mat.
Avoid touching connectors and other components.
The installation site must have the following environmental conditions:
Humidity: 20%-80% non-condensing
Temperature: 10°C-35°C (50°F-95°F)
Altitude: 0 to 10,000 feet (0 to 3048 meters)
These environmental conditions apply when the DX-Series system is in operation.
OTE: For additional specifications, refer to the
N
Quantum DX3000 and DX5000 User’s Guide
81-81493)
(PN
NOTE: Dry climates and cold-weather heating
environments have lower relative humidity and are more likely to produce static electricity.

Unpacking the DX3000/DX5000 0

This section explains how to unpack both the DX3000 and DX5000 system components and move them to their final installation location.
By following these instructions, you help ensure that the system will continue to be safeguarded after it arrives at the installation site.
2
DX3000 and DX5000 Quick Start Guide
Unpack and remove the following components from the packing materials (see figure 2
and figure 3):
DX3000 or DX5000 chassis
Hard drive sleds
Accessory kit
W
ARNING: The DX3000 weighs 38 lbs (17.24 kg) and
the DX5000 weights 85 lbs (38.56 kg) without hard drives. Two people are required to lift either unit.
Figure 2 Unpacking the DX3000
Foam
DX3000 chassis Lift point
Figure 3 Unpacking the DX5000
Foam
Antistatic bag
Hard drive sleds
Accessory kit
Foam
Lift point
DX5000 chassis
Foam
Antistatic bag
Hard drive sleds
Rail kit
Foam
Foam
Cables
Quick start
Foam

Installing the DX3000/DX5000 System

Installing the DX3000/5000 in a rack consists of the following steps:
Locating the Mounting Position
Installing the DX3000/DX5000 Chassis

Locating the Mounting Position

Both the DX3000 and DX5000 systems are designed to fit in a standard 19 inch wide rack. It is important to the chassis installation to locate the hole pattern in the rack rails (see
figure 4
).
0
0
3
DX3000 and DX5000 Quick Start Guide
Figure 4 Rail Hole Pattern
5U
7U of rack space
2U
1 DX5000 System (5U)
1 DX3000 System (2U)
The marks above (X) indicate the location of mounting hardware on the rack rails. Ensure that any necessary mounting hardware is installed on the rack rails prior to installing the chassis.
1U = 1.75 in (44.45mm)
1U = 1.75 in (44.45mm)
Hole pattern
Top of rack
.312 in (7.92 mm) .625 in (15.9 mm) .625 in (15.9 mm)
.5 in (12.7 mm) .625 in (15.9 mm) .625 in (15.9 mm)
.5 in (12.7 mm)

Installing the DX3000/ DX5000 Chassis 0

1 Assemble the DX3000/DX5000 support brackets
figure 5
:
For the DX5000 - The DX5000 rails are preset for
easy installation. Loosen the two nuts securing the back portion of the rail so the rail can adjust to the depth of the rack.
For the DX3000 - The DX3000 rails are preset for
28 in (71.1cm). Loosen the nuts to adjust the rails to the depth of the rack.
OTE: Two sizes of support brackets are included
N
with the DX3000 rails to support various rack depths. Measure the depth of the rack to determine the depth. The short brackets (5 in., 12.7cm) are used for rack depths of 28 to 31 in (71.1 to 78.7 cm). The long brackets (10 in., 25.4 cm) are used for rack depths of 32 to 36 in (81.3 to 91.4 cm). Use the appropriate support bracket for your rack.
ARNING: If the rack is empty at the time of
W
installation, do NOT install the DX3000 or DX5000 chassis too high in the rack. The weight of the chassis may cause the rack to become “top heavy” and unstable if installed in the top of an empty rack.
OTE: Quantum ships sufficient clip nuts to support
N
mounting the DX3000/DX5000 rack rails and also to secure the front of the chassis to the rails.
Clip nut
4