Installation and Wiring Instructions for Mixed Flow Inline Duct Exhaust Fans
Directives d’installation et de branchement électrique des ventilateurs hélico-centrifuges en ligne
Instrucciones de instalación y conección eléctrica ventiladores heliocentrifugal in-line
Models/Modèles/Modelos
99-NBQ-525-8
99-NBQ-700-10
99-NBQ-950-12
General/Généralités/Generalidades
Before installation, careful consideration must be given to how
this system will operate if connected to any other piece of
mechanical equipment. It is always important to assess how
the operation of any air movement device may interact with
vented combustion equipment (i.e. Gas Furnaces, Oil
Furnaces, Wood Stoves, etc.).
NEVER install a ventilator in a situation where its normal
operation, lack of operation or partial failure may result in the
backdrafting or improper functioning of vented combustion
equipment without proper safety/ warning devices installed as
required.
Avant de procéder à l’installation, vous devez déterminer comment ce système interagira s’il est raccordé à toute autre pièce
d’équipement mécanique. Il est toujours important d’évaluer quel
impact aura le fonctionnement de tout équipement de déplacement d’air sur un appareil à combustion (ex. : fournaise au gaz,
fournaise à l’huile, poêle à bois, etc.)
N’installez JAMAIS un ventilateur dans une situation où son
fonctionnement normal, une opération inadéquate ou une défaillance partielle pourrait causer un refoulement ou un mauvais
fonctionnement d’un appareil à combustion sans y installer, tel
que requis, un système de sécurité/d’alarme.
Antes de instalarla, usted debe determinar como este sistema
obrará si es ajustado a cualquiera otra pieza de equipo mecánico. Siempre es importante evaluar el impacto que tendrá el
functionamiento de todo equipo de desplazamiento de aire en un
aparato a combustión (ejemplo: horno de gas, horno de aceite,
estufa de leña, etc...).
Jamás instale un ventilador en una situación donde su functionamiento normal, una operación inadecuada o que un fallo parcial
pueda causar una descarga o un mal funcionamiento de un
aparato a combustión sin instalar tal como es requerido, un sis
tema de seguridad/alarma.
Table of Contents/Table des matières/Índice
General .......................................................................................1
Table of Contents........................................................................1
Typical Applications ....................................................................2
Installation...................................................................................3
Electrical......................................................................................4
Instructions...............................................................................5-6
Warranty......................................................................................7
Généralités..................................................................................1
Table des matières......................................................................1
Applications types
Installation...................................................................................9
Branchement électrique
Directives .............................................................................11-12
Garantie
Generalidades
Índice...........................................................................................1
Aplicaciones típicas...................................................................14
Instalación
Conección eléctrica ..................................................................16
Instrucciones
Garantía
-
....................................................................................13
.................................................................................
...................................................................................19
.......................................................................
............................................................10
.............................................................................
........................................................................
8
1
15
17-18
98-NBQ-8/10/12
0305
Installation
Model 99-NBQ-525-8
1. Secure mounting bracket to fixed structure.
With one screw loosely fitted to fan mounting lug; locate
2.
and align in the slotted mounting bracket hole.
3. Align the other fan fixing hole with the mounting bracket. Insert the bolt and washers provided. Fully tighten
both screws to secure the fan.
Figure 2
Model 99-NBQ-700-10 & 99-NBQ-950-12
1. To install the PVP-SL10 & 12 models, the fan
motor/wheel assembly must first be removed. Loosen
the two spring clips around the casing and remove.
2. Secure the mounting bracket.
3. Replace the fan motor/wheel assembly and tighten the
two spring clips to secure the product.
3
Electrical
Figure 3
Motor without Speed Controller
Motor with Speed Controller
IMPORTANT
8”, 10” and 12” metal fans incorporate two speed (120VAC 60Hz) motors. The live supply must
only be made to terminal
HI
or LOconnection -
NOT TOGETHER
.
4
Instructions
99-NBQ
The 99-NBQ mixed flow range of inline duct exhaust fans
have been manufactured in accordance with the rigorous
standards of production as defined by the International
Quality Standards ISO 9001. All the components have
been checked and tested at the end of the manufacturing
process.
We recommend that you check the following after receiving the product:
1. The correct size has been received.
2. The correct model has been received.
3. That the details on the rating label correspond to the
electrical supply: voltage frequency, etc.
Remove the unit from packaging and inspect for shipping
damage with in 15 days of receipt. If the product is found
to be damaged, immediately contact your local authorized
supplier. DO NOT OPERATE UNIT IF DAMAGED.
These instructions should be considered as a supplement
to EPA standard practices, as well as all state and local
building code regulations.
Environment
The 99-NBQ series of fans are suitable for operation in
both Indoor and Outdoor environments. All models are
suitable for exhaust or supply operation in the temperature
range (inclusive of duct airstream temperature) of -40˚C
(-40˚F) up to +60˚C (140˚F).
Installation
WARNING: To reduce the risk of fire or electric shock,
injury to persons, observe the following:
a) Use this unit only in the manner intended by the manu-
facturer. If you have any questions, contact the
manufacturer.
Before servicing or cleaning the unit, switch the power
b)
off at the service panel and lock the service disconnect
ing means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning
device such as a tag to the service panel.
c) Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable
codes and standards including fire rated construction.
d) Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturers’ guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA) and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE) and the local code authorities.
e) When cutting or drilling into wall or ceiling, do not dam-
age electrical wiring and other hidden utilities.
f) Ducted fans must always be vented to the outdoors.
g) If this unit is to be installed over a tub or a shower, it
must be marked as appropriate for the application and
connected to a GFCI (Ground Fault Circuit Interrupter)
- protected branch circuit.
h) Never place a switch where it can be reached from a
tub or shower.
i) CAUTION: For general ventilating use only. Do not
use to exhaust hazardous or explosive materials
and vapours.
j) CAUTION: This unit has an unguarded impeller. Do
not use in locations readily accessible to people or
animals.
The 99-NBQ series can be mounted in any orientation,
horizontal or vertical and is suitable for numerous types of
applications. See Figure (1). Illustration of some typical
applications.
IMPORTANT:
When using 99-NBQ units in conjunction
with range hoods, the following instructions should be
noted.
WARNING- TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING:
a) Never leave surface units unattended at high settings.
Boil-overs cause smoking and greasy spill-overs that
may ignite.
b) Always turn hood ON when cooking at high heat or
when cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
-
for the size of the surface element.
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:
a) Smother flames with a close fitting lid, cookie sheet or
metal tray, then turn off the burner. Be careful to pre
vent burns. If flames do not go out immediately,
evacuate and call the fire department.
Never pick up a flaming pan - you may be burned.
b)
Do not use water, including wet dishcloths or towels, a
c)
violent steam explosion will result.
d) Use an extinguisher ONLY IF:
(i) You know you have a class ABC extinguisher and
you already know how to operate it.
(ii) The fire is small and contained where it started.
-
5
Instructions
(iii) The fire department is being called.
(iv) You can fight the fire with your back to an exit.
e) TO REDUCE THE RISK OF FIRE, ONLY USE METAL
DUCTWORK.
If the installation is made to rigid or flexible ducting, then
we should recommend the correct diameter ducting is
used to couple to the fan flanges. if it is necessary to bend
the duct at the discharge of the fan, then the bend radius
should be as large as possible.
Before installing the product check the following points:
1. the fan impeller turns freely and
2. there are no obstructions to the airflow
All models include a robust mounting bracket which
enables easy and quick installation of the fan. See Figure
2 installation diagram for 99-NBQ duct fans.
Ductwork connection should be made with duct tape or
duct fast-clamps (available through your local supplier) to
ensure a good seal and secure connection.
Electrical Connection
All 99-NBQ series fans operate from a standard 120V
60Hz AC electrical supply. All wiring must be carried out in
accordance with National Electric Code and all applicable
state and local building codes.
Electrical connections should be made in accordance with
the following diagrams: Figure 3 Electrical wiring.
Maintenance
IMPORTANT: BEFORE CARRYING OUT ANY MAINTENANCE OR SERVICING, ENSURE THAT THE UNIT IS
DISCONNECTED FROM THE MAIN ELECTRICAL SUPPLY.
All 99-NBQ series exhaust fans incorporate sealed for life
bearings and therefore so not require any lubrication. We
would recommend inspection of the product at least once
every twelve (12) months to avoid excessive accumulation
of dust and dirt on the impeller. To inspect the unit, disconnect from electrical supply and remove the ducting. If any
debris is evident on the impeller, clean with a damp (not
wet) cloth. DO NOT USE any detergents or abrasive materials for cleaning.
6