Quantum 6311658V7R0, 6311658V7R0 2 User Manual

SNMP Integration
Guide
6311658-07
Ver. 7, Rel. 0
SNMP Integration Guide, 6311658-07, Ver. 7, Rel. 0, December 2003. Made in USA.
Quantum Corporation provides this publication “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice.
COPYRIGHT STATEMENT
Copyright 2003 by Quantum Corporation. All rights reserved.
Your right to copy this manual is limited by copyright law. Making copies or adaptations without prior written authorization of Quantum Corporation is prohibited by law and constitutes a punishable violation of the law.
TRADEMARK STATEMENT
Prism Storage Architecture is a trademark of Quantum Corporation. Other trademarks may be mentioned herein which belong to other companies.
6207947-06cP 29

Contents

Preface ix
Chapter 1 Unicenter TND on Windows NT/2000 1
Overview............................................................................................................. 1
System Requirements on Windows NT/2000 ............................................... 2
Level of Security.......................................................................................... 2
Activating SNMP Traps .................................................................................... 3
Pre-Installation Steps......................................................................................... 4
Installing the SNMP Integration Software ..................................................... 5
Setting Up Unicenter TND ...............................................................................8
Following Up: Testing the Library Icon........................................................ 10
Uninstalling SNMP Integration Software .................................................... 11
Uninstalling Software from Windows NT 4.0...................................... 11
Uninstalling Software from Windows 2000.......................................... 12
Troubleshooting ............................................................................................. 12
SNMP Integration Guide iii
Chapter 2 OpenView NNM on Windows NT/2000 13
Overview ...........................................................................................................13
System Requirements on Windows NT/2000..............................................14
Level of Security........................................................................................14
Installing SNMP Integration Software ..........................................................15
Installing Software from a CD.................................................................15
Duplicate IP Addresses ...................................................................................17
Setting Up OpenView NNM ..........................................................................18
Changing Symbol Type............................................................................19
Configuring Status Source .......................................................................20
Configuring Object Attributes.................................................................21
Following Up: Testing the Library Icon........................................................22
Uninstalling Library Integration Software ...................................................23
Uninstalling Software from Windows NT 4.0 ......................................23
Uninstalling Software from Windows 2000 ..........................................24
Troubleshooting................................................................................................24
Chapter 3 OpenView NNM on Solaris 25
Overview ...........................................................................................................25
System Requirements on Solaris....................................................................26
Level of Security........................................................................................26
Installing SNMP Integration Software ..........................................................26
Installing Software from a CD.................................................................27
Installation Output Script ........................................................................27
Duplicate IP Addresses ...................................................................................28
Setting Up OpenView NNM ..........................................................................28
Configuring Object Attributes.................................................................29
Following Up: Testing the Library Icon........................................................31
Uninstalling Library Integration Software ...................................................31
Uninstalling Software...............................................................................32
Troubleshooting................................................................................................32
Appendix A Configuring the SNMP Management Web Page 33
PX720..................................................................................................................33
P-Series and M-Series ......................................................................................35
DX-Series ...........................................................................................................37
iv SNMP Integration Guide
Glossary 39
Index 43
SNMP Integration Guide v
vi SNMP Integration Guide

Figures

Figure 1 Component Activation Flags Tab .............................................. 3
Figure 2 Server Preferences Tab ................................................................4
Figure 3 SNMP Integration Installation Dialog Box ............................... 5
Figure 4 Welcome Dialog Box.................................................................... 6
Figure 5 Software License Agreement Dialog Box.................................. 6
Figure 6 Update TND Repository Information Dialog Box................... 7
Figure 7 Setup Complete Dialog Box........................................................ 8
Figure 8 2-D Map ......................................................................................... 9
Figure 9 SNMP Integration Installation Dialog Box ............................. 15
Figure 10 Welcome Dialog Box.................................................................. 16
Figure 11 Software License Agreement Dialog Box................................ 16
Figure 12 Setup Complete Dialog Box...................................................... 17
Figure 13 Subnet Map ................................................................................. 19
Figure 14 Change Symbol Type Dialog Box ............................................20
Figure 15 Symbol Properties Dialog Box.................................................. 21
Figure 16 Object Properties Dialog Box.................................................... 21
Figure 17 Attributes Dialog Box ................................................................ 22
SNMP Integration Guide vii
Figure 18 Subnet Map - Truncated View..................................................29
Figure 19 Object Properties Window ........................................................30
Figure 20 Object Attributes Window.........................................................30
Figure 21 PX720 SNMP Configuration Section........................................34
Figure 22 SNMP Configuration Page........................................................36
Figure 23 DX-Series SNMP Page................................................................38
viii SNMP Integration Guide

Preface

This manual describes how to use the SNMP Integration Kit to integrate Quantum Libraries and DX-Series Enhanced Data Protection Systems with the following third party network management software packages:
Unicenter Network and Systems Management Unicenter TND) of Computer Associates Windows NT
•OpenView (HP), supported on Windows NT, Windows 2000, and Sun Solaris environments
Supported libraries include:
M-Series (M1500, M1800, and M2500) equipped with MC300
®
and Windows® 2000
®
Network Node Manager™ (NNM) of Hewlett Packard
®
3.0 (appears as
(CA), supported on
P-Series (P4000, P7000, P2000, and P3000) equipped with MC350
DX-Series (DX30 and DX100)
PX720
Throughout this document, “library”refers to all supported products.
SNMP Integration Guide ix
Audience The intended audience for this manual is network system administrators.
Purpose The following topics are covered for each third party network
management software integration:
System requirements, includes the hardware and software components that are required to be installed and to run properly.
Pre-installation steps for the SNMP software
Installing the SNMP software from a CD or from the internet.
Setting up third party management software after installation
Configuring the management console Web pages
Testing the library icon
Troubleshooting
Removing library integration software
Document Organization
The manual is organized as follows:
Chapter 1, Unicenter TND on Windows NT/2000 system requirements and installation of Unicenter TND on a Windows platform.
Chapter 2, OpenView NNM on Windows NT/2000 system requirements and installation of OpenView NNM on a Windows platform.
Chapter 3, OpenView NNM on Solaris requirements and installation of OpenView NNM on a Solaris platform.
Appendix A, Configuring the SNMP Management Web Page describes how to configure the SNMP Management Web page.
This document concludes with a glossary and an index.
x SNMP Integration Guide
, describes the
, describes the
, describes the system
,
Notational Conventions
This manual uses the following conventions:
Note: Notes emphasize important information related to the main
topic.
Related Documents
Documents related to the SNMP integration software are shown below:
Quantum Documentation
Document No. Document Title Document Description
6311631 MC300 Prism
Management Card User’s Guide
This manual provides server management instructions for the MC300 Prism Management Card for M-Series libraries.
6473025 MC350 Prism
Management Card User’s Guide
This manual provides server management instructions for the MC350 Prism Management Card for P-Series libraries.
6444601 PX720 User’s Guide This guide contains sections
on installation, operation, and diagnostic software.
6513501 DX-Series User’s
Guide
This guide contains sections on installation, operation, and diagnostic software.
Refer to the appropriate product manuals for information about your tape drive and cartridges.
SNMP Integration Guide xi
Contacts Quantum company contacts are listed below.
Quantum Corporate Headquarters
To order documentation on Quantum products contact:
Quantum Corporation P.O. Box 57100 Irvine, CA 92619-7100 (949) 856-7800 (800) 284-5101
Technical Publications
To comment on existing documentation send e-mail to:
doc-comments@quantum.com
Quantum Home Page 0
Visit the Quantum home page at:
http://www.quantum.com
Customer Support 0
0
0
The Quantum Customer Support Department provides a 24-hour help desk that can be reached at:
North/South America: (949) 725-2100 or
Asia/Pacific Rim: (International Code)
Europe/Middle East/Africa: (International Code)
xii SNMP Integration Guide
(800) 284-5101
+61 7 3839 0988
+44 (0) 1256 848748
Send faxes for the Customer Support Department to:
North/South America: (949) 725-2176
Asia/Pacific Rim: (International Code)
+61 7 3839 0955
Europe/Middle East/Africa: (International Code)
+44 (0) 1256 848777
Send e-mail for the Customer Support Department to:
North/South America: www.quantum.com/askaquestion Asia/Pacific Rim: apachelp@quantum.com Europe/Middle East/Africa: eurohelp@quantum.com
SNMP Integration Guide xiii
xiv SNMP Integration Guide
Chapter 1
1Unicenter TND on
Windows NT/2000

Overview 1

Computer Associates (CA) allowing network administrators to graphically view their networks and the nodes attached to the network. This allows the network administrator to assess the health of these devices, as well as take corrective action if necessary.
In order for Quantum Libraries to display as actual library icons in the network management software, you must install the SNMP Integration Kit.
The SNMP Integration with Unicenter TND will:
Install the Quantum Library MIB file
Install the Quantum Library icon files
Create an Quantum Library class
Update the message map and action tables
SNMP Integration Guide 1
Unicenter TND is a network management tool
Chapter 1 Unicenter TND on Windows NT/2000 System Requirements on Windows NT/2000
SNMP integration with Unicenter TND consists of the following tasks:
Installing the SNMP Integration Software
Setting Up Unicenter TND
Following Up: Testing the Library Icon

System Requirements on Windows NT/2000 1

The SNMP integration with Unicenter TND on NT/2000 requires the following hardware and software components to run properly. These include:
Microsoft Windows 2000 or Windows NT installed and running
Hard disk drive with at least 10 MB of available space
CD-ROM drive
Internet browser: Microsoft Netscape
®
Communicator version 4.7x
®
Internet Explorer version 5.0 or 5.5, or
(server or workstation),
SNMP and SNMP trap services active and running
Unicenter TNG Framework version 2.1 or higher installed with SNMP traps activated (see Activating SNMP Traps
)

Level of Security 1 In Unicenter TNG Framework 2.1, the level of security required to

integrate the library is the same level of security required to install and
operate Unicenter TND. This is typically the System Administrator (sa)
level. The security entry is case sensitive.
In Unicenter TNG Framework 2.4 or higher, the level of security required to integrate the library is the same level of security required to install and operate Unicenter TND. This is typically the user name and password for logging into the computer network.
Note: Before beginning, verify that SNMP service is running (see
Start/Control Panel/Services).
2 SNMP Integration Guide
Chapter 1 Unicenter TND on Windows NT/2000

Activating SNMP Traps

Activating SNMP Traps 1
To activate the SNMP traps:
1 Click Start and select Programs/Unicenter TND/Enterprise
Figure 1 Component Activation Flags Tab
Management/EM Classics/Windows NT/Configuration
2 Click Settings icon.
The
EM Settings dialog box appears with the Component Activation
Flags
tab activated (see figure 1).
.
3 Change the Setting to Yes for the SNMP Trap Server Activated flag.
4 Select the Server Preferences tab (see figure 2).
SNMP Integration Guide 3
Chapter 1 Unicenter TND on Windows NT/2000 Pre-Installation Steps
Figure 2 Server Preferences Tab
5 Set preference to Yes for SNMP Trap Server Activated.
6 Exit the Unicenter TND Settings dialog box.
7 Reboot the PC for the changes to take effect.

Pre-Installation Steps 1

Before installing the SNMP integration software, edit the
c:\winnt\system32\drivers\etc\hosts file and add the library node(s):
<IP Address> <Library Name> <Library Name> is derived from the library name and the domain name
specified in the management Web page.
For example, if the library name is BLD5 and the domain is
mycompany.eng, the library name in the /etc/hosts file will be BLD5.mycompany.eng.
4 SNMP Integration Guide
Network Configuration section of your library’s
Loading...
+ 40 hidden pages