Quantum 1U Rackmount Installation Guide

Quantum 1U Rackmount
Rail Installation Guide
Introduction 3
Required Tools 3
Step 1: Installing the Chassis Sections onto the 1U Rackmount 4
Step 2: Installing the Stationary Sections onto the Equipment Rack 5
For 24-I nch Rack s . .......... ............................... ......................... ............................... .....5
For Racks Deeper than 24 Inches.............................................................................7
Step 3: Installing the 1U Rackmount into the Equipment Rack 9
Typical Rack and Slide Configurations (For Reference Only) 11
Document 81-81209-05 A01, January 2006 1
Made in the USA. Quantum Corporation provides this publicati o n “as is” without warra nty of any kind, eithe r expres s or implied , including but not
limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice.
COPYRIGHT STATEMENT
© Copyright 2006 by Quantum Corporation. All rights reserved. Your right to copy this document is limited by copyright law. Makin g copies o r adapt atio n s with out prior wr itten authorization of
Quantum Corporation is prohibited by law and constitutes a p u nishable violatio n of the law.
TRADEMARK STATEMENT
Quantum, DLT, DLTtape, the Quantum logo, and the DLTtape logo are all registered trademarks of Quantum Corporation. SDLT and Super DLTt ape are trad e marks of Quan t u m Co rporation.
Other trademarks may be mentioned herein which belong to other companies.
2
Quantum 1U Rackmount Rail Installation Guide
Document 81-81209-05 A01
January 2006

Introduction 0

The Quantum Rack Mount Slide Kit is designed to facilitate the mounting of 1U Rackmount systems in standard EIA-310 equipment racks. These telescoping slide rails provide easy access to the 1U Rackmount by allowing you to unlock and slide it forward.
Installing the slide rails involves the following steps:
Step 1: Installing the Chassis Sections onto the 1U Rackmount
Step 2: Installing the Stationary Se ction s onto the Equi pment Rack page 5
Step 3: Installing the 1U Rackmoun t into the Equipm ent Rack
Warning: For maximum stability, the equipment rack should be securely
bolted to the floor per the rack manufacturer’s recommendations.
After installing components in the equipment rack, do not pull out more than one compon e nt on its slide rails at a time. If the equipment rack is not securely bolted to the floor, the weight of more than one extended component could cause the equipment rack to become unstable, tip over, and cause dama ge , se rious b odily inj u ry, or deat h .
on page 4
on
on page 9

Required Tools 0

To install the slide rails, you may need the following additional items:
Available rack space in a suitable equipment rack
#2 PHILLIPS® screwdriver
3

Step 1: Installing the Chassis Sections onto the 1U Rackmount

Figure 1 Pressing the Release Button
There are two chas sis sec ti ons, one fo r eac h side of the 1U Rac kmoun t chas sis.
1 Pull the chassis section of the rail forward, past the mounting flange on
the front of the rail set (see figure 1
).
The intermediate section and the chassis section will lock in place when fully extended.
2 Press the release button to release the intermediate section and slide out
the chassis section (see figure 1
Stationary section
Release button
Intermediate section
).
Chassis section
0
Figure 2 Attaching the Chassis Section to the 1U Rackmount Chassis
3 Attach one chass is sec ti on to eac h si de of t he 1U Rac kmoun t chas sis usi ng
four screws per side (see figure 2
Screws
).
Front
4
Quantum 1U Rackmount Rail Installation Guide
Document 81-81209-05 A01
January 2006

Step 2: Installing the Stationary Sections onto the Equipment Rack

Follow the instructions for your size rack as follows:

For 24-Inch Racks

For Racks Deeper than 24 Inches
For 24-Inch Racks 0 1 Install both stationa ry sections onto the front pi llars of the equipment
rack, u sing two screws in the bott o m two mou nting ho l e s of e a ch stationary section (see figure 3
Configurations (For Reference Only) on page 11 for information on
appropriate mounting hardware.
Figure 3 Attaching the Front of the Stationary Section—Front View
on page 5
on page 7
). See Typical Rack and Slide
0
5
2 Attach th e short back bracket to the back e nd of the stati onary section
using two sc rews and nuts per section (see fi gure 4
Figure 4 Assembly of the Stationary Section Screws, Nuts, and Short Back Bracket
Nuts (2X)
3 Attach the back ends of the stationary sections to the back pillars of the
equipment rack, placing the short back bracket on the outside of the back pillar. Secure the stationary section to the rack pillar with two screws in the upper two mounting holes. See figure 5
).
Short back bracket
Screws (2X)
.
Figure 5 Securing the Rail Assembly—Back View
6

For Racks Deeper than 24 Inches

Figure 6 Attaching the Front of the Stationary Section—Front View
Quantum 1U Rackmount Rail Installation Guide
Document 81-81209-05 A01
January 2006
0
1 Install both stationa ry sections onto the front pi llars of the equipment
rack, u sing two screws in the bott o m two mou n t in g holes of e a ch stationary section (see figure 6
Configurations (For Reference Only) on page 11 for more i nformation.
). See Typical Rack and Slide
Figure 7 Attaching the Long Back Bracket—Back View
2 Attach the two long back brackets to the back pillar s of the equipme nt
rack with two screws in the upper two mounting holes (see figure 7
Long back bracket
).
7
3 Insert one end of the support bracket (A) into the stationary section (B) of
the rail assembly. Secure the long back bracket to the stationary section (C) with four screws and nuts (two through the long back bracket and support bracket, and two through the long back bracket, the stationary section, and the support bracket). See figure 8
Figure 8 Inserting the Support Bracket—Back View
and figur e 9.
B
Figure 9 Assembly of the Slide, Bolts, Nuts, and Support Bracket
A
Nuts (4X)
C
Long back bracket
Support bracket
Screws (4X)
8
Quantum 1U Rackmount Rail Installation Guide
Document 81-81209-05 A01
January 2006

Step 3: Installing the 1U Rackmount into the Equipment Rack0

1 Completely exten d th e intermedi a te sections out fro m the front of the
Figure 10 Extending the Intermediate Section Rail —Front View
stationary sections until they lock (see figure 10
Intermediate section
Stationary section
).
Figure 11 Sliding the Chassis Rails into Intermediate Section Rail—Front View
2 Holding the 1U Rackmount with both hands, position and then slide the
chassis sections into the intermedi ate sections . When the rele ase butt ons on the chass is sections stop agains t the intermed iate sections, press b oth release buttons (on opposite sides) and c ontinue sliding the 1U Ra c k mo u nt into th e ra il s . S e e figure 11
.
Release buttons
9
3 Slide the 1U Rackmount completely into the rack, and secure it in place by
tightening the thumbscrews on each side (see figure 12
Figure 12 Securing the 1U Rackmount into the Rack—Front View
).
Thumbscrew
10
Quantum 1U Rackmount Rail Installation Guide
Document 81-81209-05 A01
January 2006

Typical Rack and Slide Configurations (For Reference Only) 0

Figure 13 Typical Rack Configuration 1
Chassis section (mounts to 1U Rackmount)
Screws (3x)
Square hole rack
Intermediate section (floats between chassis and stationary sections)
Stationary section (mounts to equipment rack)
See figure 14
Rack vertical frame member
Nut retainers (3x)
Screws (2x)
Round hole rack
Screws (2x)
Tapped hole rack
Rack vertical frame member
Screws (2x)
Nut plate
Rack vertical frame member
11
Figure 14 Typical Rack Configuration 2
Rack vertical frame member
KEPS nuts (2x)
short back bracket
For racks 24 inches deep
Screws (2x)
Nut retainers (2x)
Square hole rack
Round hole rack
Tapped hole rack
Nut retainers (2x)
Nut plate
Rack vertical frame member
Rack vertical frame member
Screws (2x)
Rack vertical frame member
Screws (2x)
Screws (2x)
Screws (2x)
Long back bracket
KEPS nuts (4x)
Reinforcing plate
For racks 25 to 32 inches deep
Screws (4x)
Square hole rack
Round hole rack
Tapped hole rack
Nut plate
Rack vertical frame member
Rack vertical frame member
Screws (2x)
Screws (2x)
12
*81-81209-05 A01*
81-81209-05 A01
Loading...