QC10 Series Attenuators
Quam-Nichols Company
QC10 Classic
QC10
Features
• Twenty watt continuous
power rating
• Protective bracketing
guards against accidental
damage to switch leads
during installation.
• Durable, insulated, stranded
switch leads prevent
breakage and accidental
grounds.
• Positive stop action switch
• Two styles of stainless
steel trim plate
• In stock for immediate
delivery
Quam QC10 series of attenua-
tors are designed to provide
local or remote level control of
25 or 70.7 volt distributed
loudspeakers. These attenuators
can be used to control a single
speaker or groups of loudspeakers when the total speaker load
is twenty watts or less. Each
model provides ten standard
steps of attenuation plus an “off”
position. Model QC10 features a
contemporary style, embossed
position
identification stainless steel trim
plate. QC10 Classic is the traditional style, embossed, paint
filled stainless steel trim plate.
All models in this series except
QC10RM include screws to
mount to standard single gang
electrical boxes with a depth
requirement of 2-1/8 inches.
Model QC10RM is supplied with
a 2” x 2” dial scale and a barrel
extension nut to accommodate
mounting to rack panels up to
1/8” thick.
Model Type / Description
QC10 WALL MOUNT W/ EMBOSSED POSITIONS
QC10 CLASSIC WALL MOUNT W/ EMBOSSED, PAINT FILLED,
POSITIONS
QC10P WALL MOUNT W/ 24 VDC PRIORITY “BYPASS”
RELAY
QC10RM RACK PANELMOUNTED W/ DIALSCALE
Specifications
POWER RATING 20 WATTS CONTINUOUS
POSITIONS 10 PLUS “0” (OFF) POSITION
ATTENUATION STEPS STEPS 1-2 = -6 DB
REF. 70.7 VOLT LINE STEPS 3-10 = -3 DB
TOTAL ATTENUATION -36 DB (NOT INCLUDING “0” POSITION)
INSERTION LOSS < .5 DB
WALLMOUNTING PLATE SINGLE GANG BRUSHED STAINLESS STEEL
RECOMMENDED WALL (FLUSH) RAYCO #600 OR EQUIVALENT
BOX (SURFACE) QUAM SE4W
QC10P RELAY VOLTAGE 24 VDC CURRENT .015 AMPERE
CONTROL KNOB BLACK W/ WHITE POSITION INDICATOR
Architects & Engineers Specifications
The area attenuator controls shall be
Quam [insert desired model from
chart] or approved equal. Each unit
shall have a power handling capability of 20 watts continuous power.
Attenuator controls shall provide a
total of -36 dB of attenuation between
ten steps and shall include an additional off position. Rotary switches
shall allow continuous rotation
through all positions. Wall mounted
units shall be furnished with a one
gang stainless steel trim plate. Rack
mount versions shall include a dial
scale. Priority attenuator controls
shall have an integral 24 VDC relay
which when activated shall bypass
the attenuation setting. Control
knobs shall be black with a white
position indicator.
16
COMMUNICATIONS
Quam-Nichols Company
234 East Marquette Road • Chicago, IL 60637
(773) 488-5800
•FAX (773) 488-6944
Member
TS-15C