Twenty watt continuous
power rating
Protective bracketing
guards against accidental damage to switch leads during installation.
Durable, insulated, stranded
Positive stop action switch
Two styles of stainless
steel trim plate
In stock for immediate
delivery
Quam QC10 series of attenua-
tors are designed to provide local or remote level control of 25 or 70.7 volt distributed loudspeakers. These attenuators can be used to control a single speaker or groups of loudspeak­ers when the total speaker load is twenty watts or less. Each model provides ten standard steps of attenuation plus an “off” position. Model QC10 features a contemporary style, embossed position
identification stainless steel trim plate. QC10 Classic is the tradi­tional style, embossed, paint filled stainless steel trim plate. All models in this series except QC10RM include screws to mount to standard single gang electrical boxes with a depth requirement of 2-1/8 inches. Model QC10RM is supplied with a 2” x 2” dial scale and a barrel extension nut to accommodate mounting to rack panels up to 1/8” thick.
Model Type / Description
QC10 WALL MOUNT W/ EMBOSSED POSITIONS QC10 CLASSIC WALL MOUNT W/ EMBOSSED, PAINT FILLED,
POSITIONS
QC10P WALL MOUNT W/ 24 VDC PRIORITY “BYPASS”
RELAY
QC10RM RACK PANELMOUNTED W/ DIALSCALE
Specifications
POWER RATING 20 WATTS CONTINUOUS POSITIONS 10 PLUS “0” (OFF) POSITION ATTENUATION STEPS STEPS 1-2 = -6 DB REF. 70.7 VOLT LINE STEPS 3-10 = -3 DB TOTAL ATTENUATION -36 DB (NOT INCLUDING “0” POSITION) INSERTION LOSS < .5 DB WALLMOUNTING PLATE SINGLE GANG BRUSHED STAINLESS STEEL RECOMMENDED WALL (FLUSH) RAYCO #600 OR EQUIVALENT BOX (SURFACE) QUAM SE4W QC10P RELAY VOLTAGE 24 VDC CURRENT .015 AMPERE CONTROL KNOB BLACK W/ WHITE POSITION INDICATOR
Architects & Engineers Specifications
The area attenuator controls shall be Quam [insert desired model from chart] or approved equal. Each unit shall have a power handling capabili­ty of 20 watts continuous power. Attenuator controls shall provide a total of -36 dB of attenuation between ten steps and shall include an addi­tional off position. Rotary switches shall allow continuous rotation
through all positions. Wall mounted units shall be furnished with a one gang stainless steel trim plate. Rack mount versions shall include a dial scale. Priority attenuator controls shall have an integral 24 VDC relay which when activated shall bypass the attenuation setting. Control knobs shall be black with a white position indicator.
16
COMMUNICATIONS
Quam-Nichols Company
234 East Marquette Road • Chicago, IL 60637
(773) 488-5800
FAX (773) 488-6944
Member
TS-15C
Loading...