User
Manual
Commercial Water Boiler
SAVE
THESE INSTRUCTIONS FOR FUTURE
REFERENCE

L.
2.
Before
Using/Connecting to Power
Supply:
Remove all
packaging
and any
protective
plastic
coating.
Only use
urn
on a
flat level
surface that
is
adequate
to
support
the weight
when full
of water, and
keep
it
away
from
the
edge of
counters
to avoid
accident.
Do
not
place
the appliance
near a
hot
gas
or electric
burner
or near
any hot surfaces.
Close
supervision
is
necessary
when
any appliance
is
used by
or
near
children,
4.
Do not use the
water urn
outdoors.
If the
supply
cord
is
damaged,
it must
be
replaced
by
the manufacturer,
service
agent
or
similar
qualified
person
in order
to avoid
a
hazard.
(The
supply
cord
may
become
warm
when
the appliance
is in use')
If the
water
urn breakdowns
or
has been
damaged
in
any
manner,
return it
to
the nearest
authorized
service
facility
for
examination
and
repair.
7.
Always
switch
off
before
removing
plug from the
outlet.
8.
Do not lift
or
move the
urn when
it contains
hot water'
9.
Turn
off the
power supply
and
remove
the
plug when
not
in use.
Cool
the
water
urn
off
before
moving/cleaning
or
replacing
any
parts'
10.
Remove
the
plug
by
grasping the
plug. Do not
pull
the cord.
5.
6.

11. Do
not
let cord hang over edge
of counter/work
space.
IZ.Do not
place
the
appliance
where
the mains lead
could fall into
a sink.
L3. Place
the water
urn securely in center of counter
or
work
space.
L4. Always
put
water in the urn before switching on. Do
not switch
on the water urn if the water tank is
empty.
15. To
protect
against
electric shock, do not immerse the
water urn
in water.
16. Switch OFF after use and unplug
the unit
from the
socket.
l7.Do not overfill urn as there is a risk that boiling
water will
be ejected
from
around the lid.
18. The water urn should not be
operated by
persons
(including
children) with reduced
physical,
sensory
or mental capabilities,
or
lack
of experience or
knowledge, without
supervision.

THE
WATER
URN
Cool-touch handles
Temperafure
Control
Plastic
lid with
twist
lock
OrVOff
switch
THE APPLIANCE
IS NOW
READY TO USE
WARNING:
-
Do
not touch the
surface.
The surface of the
water
urn
gets
very
hot during use.
- Do
not remove the
lid while boiling.
- If the
appliance
is overfilled, boiling
water may spill
out.
- This appliance
is not intended
for use by
young
children unless
they
are adequately supervised
by
a
responsible
person
to ensure
that they can
use the
appliance safely.

i
I
l
I
I
.
Before
Use:
Fill,
heat, and
discard the
water twice
before
general use.
-
Under
filling
may
cause
the thermal
cut-out to
operate
[and
may
shorten
the
element life).
HOW TO USE
1. Remove all
packaging
before
use.
2.
Place
the drip
tray on
the base
underneath
the
tap,
as shown in
picture.
3. Twist lid anti
clockwise.
Open the
lid
and fill the
urn
with the
desired
amount
of
water.
Do not fill above
the MAX
capacity
mark.
4. Always
put
water
in the urn before
switching
on.
5.
Plug the
urn to the
main
socket.
6. Switch
ON the
urn. The
red indicator
light
will
illuminate
when water
is heating.
After the
water
has
boiled
the
urn will
automatically
switch to
keep
warm, and
the
green
indicator
light will
illuminate
showing
that the
urn is
preserving heat.
7.
Turn the temperature
control to
the desired
setting.
This urn
is not
intended to
continuously
boil water
due to
the hazards
of steam and
water escaping
from
under
the
lid.
B. Use the
water faucet
to dispense
water. Open the
tap
by
pulling
the
tap lever to
the horizontal
position;
close
the tap
by returning
the lever to the
vertical
position.
9.
When about
three cups of
water are
remaining in the
urn,
turn the appliance
off and
unplug it from the
electric
outlet.
ro. Always
make
sure there
is at least minimal water
in
the
urn to
prevent boil-dry.
I

BOIt-DRY
PROTECTION
To
prevent
accident
from
boil-dry, the appliance
is
protected
with
a
thermal limiter. If water in the tank
is
boiled dry, the limiter
activates and
the appliance turns
itself
off, although
the lamp will remain
on.
If
the thermal
limiter is
activated, there
is
a manual reset
button
located
in the middle of the base bottom. Turn
off unit. Let to cool.
Press button to reset.
THERMAL
CUT-OUT
The heating
element is fitted
with a thermal cut-out,
which
protects
the urn from
damage when continuous misuse
of
the
urn is allowed
[boil
dry, switched
on
without
water,
or
the appliance
exterior has
been accessible with water)
the
thermal cut-out will
stop the appliance
from working.
Do not confuse
thermal cut-out
with boil-dry
protection.
Thermal
cut-out in
the appliance is
a disposable
part.
Once
thermal cut-out is
triggered, the appliance
will be
impaired
and cannot
be used again. Therefore
the
appliance
should be taken
to an authorized agent
to
replace
the thermal
cut-out. A single fuse will
be replaced.
In rare instances, if
the heating element is
damaged, the
unit
must
be replaced.
CLEANING AND MAINTENANCE
ALWAYS TURN
OFF THE POWER
SUPPLY, REMOVE THE PLUG
AND ALLOW
THE URN TO
COOL
BEFORE
CLEANING.
THIS
URN IS NOT
WATERPROOF!

ELECTRIC
CIRCUIT DIAGRAM
This
appliance requires a 16Amp
plug.
USAGE PAMNIETERS:
Model No. Power
Approximate
Capacity
Voltage Environmental
Temperature
in Use
Environmental
Humidity
in Use
MISBB2 1500w 9L
220V-
240V/
50Hz
10-38 degrees Less
than 90%
MISBB3 1500w
20L
220V-
240V/
50Hz
10-38
degrees Less than 90%
MISBB4 2500w 351
220V240V
/
50Hz
10-38 degrees Less
than
90%