Quality Craft MM228R-50EDC User Manual

Page 1
ELECTRIC FIREPLACE
HEATER
Model: MM228R-50EDC
IMP ORTANT: PLEASE NOTE : WHEN YOU OPEN THE CARTON CAREFULLY CHECK THE UNIT AND MAKE SURE THERE IS NO DAMAGE. IF YOU HAVE ANY PROBLEMS WITH ASSEMBLING THE UNIT, WITH HOW THE VARIOUS FUNCTIONS WORK OR WITH DAMAGE OR MISSING PARTS PLEASE CALL 1-800-459-4409 (9 :00 AM ­5: 00 PM EST) IMMEDIATELY FOR SERVICE.
NOTE: DO NOT RETURN UNIT TO THE STORE BEFORE CALLING THE TOLL FREE NUMBER. DO NOT DISPOSE OF YOUR CARTONS UNTIL YOU ARE COMPLETELY SATISFIED WITH YOUR NEW FIREPLACE HEATER.
NOTE: Light bulbs may become loose during shipping. If the flame effect is dim or does not work, please check that light bulb or bulbs are finger tight in socket. See instructions for replacing bulb or bulbs.
NOTE: The electric fireplace heater may emit a slight harmless odor when first turned on. This is caused by activating the internal heater components for the first time and should not occur again.
INSTRUCTION MANUAL
ATTENTION:
1) Find a location for the fireplace heater that is protected from direct sunlight.
2) Do not plug the unit into the power outlet before reading all instructions.
IMPORTANT SAFETY INSTRUCTIONS
WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:
1) Read all instructions before using this electric fireplace heater.
2) This electric fireplace heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. The grill directly in front of the heater outlet becomes hot during heater operation. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9 m) away from the front of the unit and keep them away from the sides and rear.
3) Extreme caution is necessary when any heater is used by, or near, children or individuals with disabilities and whenever the fireplace is left operating and unattended.
4) Always unplug fireplace when not in use.
5) Do not operate any electric fireplace with a damaged cord or plug or after the heater malfunctions, has been dropped or damaged in any manner.
6) Do not use outdoors.
7) This electric fireplace heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never place electric fireplace heater where it may fall into a bathtub or other water container.
8) Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area and where it will not be tripped over.
9) To disconnect fireplace, turn controls to off, then remove plug from outlet.
10) Connect to properly grounded outlets only.
11) Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater.
12) To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked.
13) A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
14) Use this fireplace heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
15) Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire. However, if you have to use an extension cord, the cord shall be No. 14 AWG minimum size and rated not less than 1875 watts.
16) Caution: Do not plug this product into a receptacle controlled by a wall switch or dimmer.
17) When storing or transporting the unit and cord, keep in a dry place, free from excessive vibration and store so as to avoid damage.
SAVE THESE INSTRUCTIONS FOR FUTURE USE.
CAUTION:
IF YOU USE THIS HEATER IN CONJUNCTION WITH A THERMAL CONTROL, A PROGRAM CONTROLLER, A TIMER OR ANY OTHER DEVICE THAT SWITCHES THE HEATER ON AUTOMATICALLY, REMEMBER TO OBSERVE ALL SAFETY WARNINGS AT ALL TIMES. THE FIREPLACE HEATER HAS SAFET Y OVERHEAT PROTECTION. IF THE OVERHEAT PROTECTION TRIPS, SWITCH OFF ALL SWITCH BUTTONS AND WAIT APPROXIMATELY 5 -10 MINUTES. IT SHOULD RESET AUTOMATICALLY ONCE THE UNIT COOLS DOWN.
WARNING:
PROCEDURES AND TECHNIQUES IF NOT CAREFULLY FOLLOWED WILL RESULT IN DAMAGE TO THE EQUIPMENT AND WILL EXPOSE THE USER TO THE RISK OF SERIOUS INJURY, ILLNESS OR DEATH.
THIS ELECTRIC FIREPLACE HEATER IS FOR USE ON 120 VOLTS. THE CORD HAS A PLUG AS SHOWN AT A IN ILLUSTRATION BELOW. AN ADAPTER AS SHOWN AT C IS AVAILABLE FOR CONNECTING THREE-BLADE GROUNDING-TYPE PLUGS TO TWO-SLOT RECEPTACLES. THE GREEN GROUNDING PLUG EXTENDING FROM THE ADAPTER MUST BE CONNECTED TO A PERMANENT GROUND SUCH AS A PROPERLY GROUNDED OUTLET BOX. THE ADAPTER SHOULD NOT BE USED IF A THREE-SLOT GROUNDED RECEPTACLE IS AVAILABLE.
A 15 AMP CIRCUIT IS REQUIRED TO OPERATE THIS HEATER. IF THE BREAKER TRIPS WHEN THE HE ATER IS USED THEN YOU MAY NEED TO MOVE THE HEATER TO ANOTHER LOCATION OR UNPLUG OTHER APPLIANCES THAT ARE ON THE SAME CIRCUIT. IF YOU REQUIRE AN E XTENSION CORD USE ONE THAT IS RATED AT 1875 WATTS.
1
Page 2
PARTS LIST
Fireplace insert...................................................................................................... 1
A) Top panel ........................................................................................................ 1
B) Base panel ...................................................................................................... 1
C) Left outer side panel ........................................................................................ 1
D) Right outer side panel ...................................................................................... 1
E) Lef t inner side panel ........................................................................................ 1
F) Right inner side panel ...................................................................................... 1
G) Left front panel ................................................................................................ 1
H) Right front panel .............................................................................................. 1
I) Back panel ...................................................................................................... 2
J) Upper back panel ............................................................................................. 1
K) Middle panel .................................................................................................... 1
L) Shelves ........................................................................................................... 4
M) Left door ......................................................................................................... 1
N) Right door ....................................................................................................... 1
O) Door handle screws ......................................................................................... 2
P) Door handles ................................................................................................... 2
Q) Magnets .......................................................................................................... 2
R) Door hinges ..................................................................................................... 4
S) Door mounting screws ................................................................................... 20
T) Shelf supporting pins ..................................................................................... 16
U) L-Mounting brackets ........................................................................................ 2
V) Short KD screws .............................................................................................. 2
W) KD screws ..................................................................................................... 84
X) Plastic connectors ......................................................................................... 28
Y) SELF REPAIR SET
Touch-up repair paint (bottle) ........................................................................... 1
L-shape bracket ............................................................................................... 2
Screws for L bracket ........................................................................................ 8
Plastic connectors ........................................................................................... 1
KD screws ....................................................................................................... 3
KD nuts ........................................................................................................... 3
THI S FIRE PLACE MA NTEL REQ UIRES 1 - 2 PE OPLE T O ASS EMBL E AND N ORMALLY TAK ES 45 MINU TES - 1 HOUR T O COMP LET E.
TOOL REQUIRED: PHILLIPS HEAD SCREWDRIVER
BACK
MANTEL ASSEMBLY
CAUTION: Place a piece of cardboard or protective sheet on the floor in order to avoid scratching the decorative sur face of your mantel during assembly.
Please DO NOT fully tighten the KD screws until all panels are assembled.
NOTE: Each plastic connector is pre-assembled (pre-drilled) on the specific panels with 2 screws. If the KD screw (s ) do not fit during assembly, loosen the 2 (pre-drilled) screws to adjust the plastic connector until the KD screws are able to be installed. Tighten all KD screws once all panels are assembled.
2
Page 3
Step 1: Attach 28 plastic connectors [X] to panels C, D, E, F, G, H, I and K with 56 KD
screws [W] as shown in Fig. A (2 KD screws for each plastic connector).
Fig. A BACK
Step 2: Attach Door hinges [ R] to Panels G and H with 8 door mounting screws [S].
Attach 16 shelf supporting pins [T ] to panels C, D, E and F. See Fig. B.
Step 3: Attach panel G to panel C with 2 KD screws. Attach panel H to panel D with 2
KD screws. See Fig. C.
Fig. C BACK
Step 4: Attach panels C, D, E and F to Panel B with 6 KD screws. See Fig. D.
Fig. B BACK
Fig. D BACK
Step 5: Attach panel K to panels E and F with 4 KD screws. See Fig. E.
Fig. E BACK
3
Page 4
Step 6: Attach panels I to panels C, D, E and F with 8 KD screws. See Fig. F.
Fig. F BACK
Step 7: At tach panel J to panel K as shown in Fig. G.
Step 8: Attach panel A to the unit as shown in Fig. H with 6 KD screws.
Fig. H FRONT
Step 9: Attach magnets [Q] to panel E and F with 4 door mounting screws [S]. See
Fig. I.
Fig. G BACK
Fig. I FRONT
4
Page 5
Step 10: Attach shelves [L] to the unit as shown in Fig. J.
Fig. J FRONT
Step 11: Attach door handles [P] to Left door and right door [M and N] with door
handle screws [ O]. See Fig. K.
FIREPLACE INSERT INSTALLATION
The fireplace insert can be installed after the mantel has been fully assembled.
WARNING: Make sure the fireplace insert controls are in the OFF position and the unit is NOT plugged in.
Step 1: Carefully place the insert in the unit opening. The front of the insert should be
flush with the front of the mantel. Carefully lift the insert into the mantel until the top stopper is against the mantel. See Fig. M.
Fig. M BACK
Step 2: Attach 2 L-mounting bracket [U ] to the insert with 2 short KD screws [V]. See
Fig. N.
Fig. K
Step 12: Attach left and right doors to the unit as shown in Fig. L with 8 door
mounting screws [S].
Fig. L FRONT
Step 13: Tighten all KD screws.
Fig. N BACK
Step 3: Move assembled unit to desired location. Unit should not be positioned in area
exposed to direct sunlight.
5
Page 6
OPERATION
OPERATION BY THE REMOTE CONTROL
After reading complete instructions, confirm all controls on fireplace are in the OFF position. Plug the fireplace into a 15AMP/120Volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 WATTS. Once the fireplace inser t has been properly connected to a grounded electrical outlet, it is ready to operate.
OPERATION BY THE CONTROL PANEL
The controls are located behind the 2 front covers at the top right and left corners of the insert, and can be accessed by gently pushing the bottom of the covers.
O/I: Press this button for main power function. The unit will beep and the indicator light will be on. Press again will stop the main power function. Once the heater is switched off, the indicator light will flash and the unit will keep working with air flow for 5 more seconds.
: Press this button once for flame ef fect. The unit will beep and the indicator
light will be ON. The bulbs for flame effect & log-set will be ON. To adjust the flame intensity, hold down the button – the flame optics will go higher or lower. Once you have found the desired setting, release the button. Pressing the button again will stop the light function.
750W: Press this button for low heat level. The unit will beep, the indicator light will be on. The fireplace heater will give low heat level. Pressing once again will stop the low heat level function.
1500W : Press this button for high heat level. The unit will beep, the indicator light will be on. The fireplace heater will give high heat level. Pressing once again will stop the high heat level function.
Temperature Control: To adjust the temperature to your individual requirements, turn the temperature control dial to the right ( clockwise) to increase the desired temperature and to the left for lower temperature. This temperature control dial can only be used while the O/ I switch and 750W & 1500W switches are in the ON position.
Note: When the O /I switch is turned off, all other heater functions will stop even though the switches may be in the on position.
Note: In order to shut down the heater safely, it is recommended to turn the temperature control knob to lowest setting and allow the heater to cool down before press the O/I switch to off position.
Plug in your electric fireplace and it will beep once. This means you have power and your remote is ready to operate your electric fireplace.
0/I: Press this button for main power function. The unit will beep and the indicator light will be on. Press again will stop the main power function.
Once the heater is switched off, the indicator light will flash and the unit will keep working with the air flow for 5 more seconds.
: Press this button once for flame ef fect. The unit will beep
and the indicator light will be ON. The bulbs for flame & log-set will be ON. To adjust the flame intensity, hold down the button – the flame optics will go higher or lower. Once your have found the desired setting, release the button. Pressing the button again will stop the light function.
750W: Press this button for low heat level. The unit will beep and indicator light will be ON. The fireplace heater will give low heat level. Press once again will stop the low heat level function.
1500W : Press this button for high heat level. The unit will beep and indicator light will be ON. The fireplace heater will give high heat level. Press once again will stop the high heat level function.
REMOTE CONTROL BATTERY REPLACEMENT
Replace with 2 AA A batteries.
WARNING : DO NOT MIX OLD AND NEW BATTERIES. DO NOT MIX ALK ALINE, STANDARD (CARBON-ZINC), OR RECHARGEABLE (NICKEL CADMIUM) BATTERIES.
MAINTENANCE
Disconnect power and unplug the power cord before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. The bulbs in your unit can become extremely hot. Allow at least 10 minutes between turning off the unit and removing the light bulbs to avoid the accidental burning of the skin.
RISK OF FIRE: DO NOT EXCEED THE RECOMMENDED BULB WATTAGE.
REPLACING THE FLAME EFFECT LIGHT AND LOG-SET LIGHT BULBS
Step 1: Remove the 2 screws on the front of the fireplace
and open the glass window.
Step 2: Remove the screws from both sides of the log set bed.
Step 3: Remove the log set bed. You will find 2 x 40 Watt type E-12 bulbs.
Step 4: Loosen, remove and replace the burnt out bulb(s).
Step 5: Set the log set bed back into place and re-attach the screws.
Step 6: Close the glass window and re-attach the screws.
Step 7: Plug in the unit.
6
Page 7
OPTION 1:
Use the spare KD nuts, K D screws and plastic connector.
1. Place the plastic connector on the mantel unit and mark the drill-holes as shown in Fig. A.
Fig. A
REPAIR SET
TOUCH-UP REPAIR PAINT
Paint directly on the mantel unit if necessary.
2. Drill the holes with diameter 3/4 inches (10 mm) and depth 3/4 inches the mantel. Each plastic connector needs 3 holes. See Fig. B.
Fig. B Fig. C
3. Gently install the KD nuts into the drilled-holes with hammer as shown in Fig. C.
4. Attach the plastic connector and lock in place with KD screws as shown in Fig. D.
(10 mm) on
REPAIRS
If any problems are found with the original parts during mantel assembly, such as the panels cannot be installed with the plastic connector, try to solve by one of the following methods:
Tools required: Electric drill, drill bits 3 /4 inches (10 mm) or 1/16 inches (2 mm), pencil, hammer, Phillips screwdriver, safety goggles and gloves (if necessary).
WARNING : Wear goggles before you start drilling.
Fig. D
OPTION 2:
Use the small L-brackets and screws.
1. Place the small L-bracket to the unit as shown and mark the drill-holes on the mantel as shown in Fig. E.
Fig. E
7
Page 8
2. Drill the holes with diameter 1/16 inches (2 mm) and depth 5/16 inches ( 8 mm) on the mantel. Each small L-bracket needs 4 holes. See Fig. F.
Fig. F Fig. G
WARRANTY
Every electric fireplace heater is tested before it leaves the factory and it is guaranteed for one year. If the unit should fail to operate correctly within one year from the date of purchase, call customer service at 1-800-459-4409 (9 :00 AM - 5:00 PM EST ). We will, at our discretion either repair or replace the unit. It will have to be returned to us freight prepaid and we will return the repaired or replaced unit to you freight prepaid. The company’s sole obligation is to repair or replace the unit.
This warranty is void if in the opinion of Qualit y Craft the unit has been tampered with, altered, misused, damaged, abused or used with the wrong power source. Light bulbs and remote batteries are not covered by this warranty. The warrant y is for homeowner use only and does not cover units used in commercial situations.
3. Attach the small L-bracket and lock in place with screws as shown in Fig. G.
CLEANING
To clean unit first turn off controls on unit and unplug the unit from power source. To clean glass display panel; remove dust with clean dry cloth or to remove finger prints and other marks clean glass with clean damp cloth. Do not use abrasive cleaners or spray liquids on glass display panel surface. Metal and metal painted parts should be cleaned with damp cloth. Do not use abrasive cleaners or spray liquids on these surfaces.
Imported by
Quality Craft
Laval, Quebec, Canada H7S 2G7 1-800-459-4409 (EST)
www.qualitycraft.com
Made in China
8
Loading...