IMP ORTANT:
NOTE: DO NOT RETURN UNIT TO THE STORE BEFORE CONTACTING OUR CUSTOMER SERVICE DEPARTMENT. DO NOT DISPOSE OF YOUR CARTONS UNTIL YOU ARE COMPLETELY SATISFIED WITH YOUR NEW FIREPLACE HEATER.
NOTE : Light bulbs may become loose during shipping. If the flame effect is dim or does not work, please check that light bulb or bulbs are finger tight in socket. See instructions for replacing bulb or bulbs. Please do not return the sample to the store before checking light bulbs.
NOTE: The electric fireplace heater may emit a slight harmless odor when first turned on. This is caused by activating the internal heater components for the first time and should not occur again.
INSTRUCTION MANUAL
ATTENTION:
1. Find a location for the fireplace heater that is protected from direct sunlight.
2. Do not plug the unit into the power outlet before reading all instructions.
IMPORTANT SAFETY INSTRUCTIONS
WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:
1) Read all instructions before using this electric fireplace heater.
2) This electric fireplace heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. The grill directly in front of the heater outlet becomes hot during heater operation. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 0.9 m (3 ft) away from the front of the unit and keep them away from the sides and rear.
3) Extreme caution is necessary when any heater is used by or near children or individuals with disabilities and whenever the fireplace is left operating and unattended.
4) Always unplug fireplace when not in use.
5) Do not operate any electric fireplace with a damaged cord or plug or after the heater malfunctions, has been dropped or damaged in any manner.
6) Do not use outdoors.
7) This electric fireplace heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.
8) Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area and where it will not be tripped over.
9) To disconnect fireplace, turn controls to off, then remove plug from outlet.
10) Connect to properly grounded outlets only.
11) Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater.
12) To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked.
13) A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
14) Use this fireplace heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
15) Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire. However, if you have to use an extension cord, the cord shall be No.14 AWG minimum size and rated not less than 1875 watts.
16) Do not plug this product into a receptacle controlled by a wall switch or dimmer.
17) When storing or transporting the unit and cord, keep in a dry place, free from excessive vibration and store so as to avoid damage.
SAVE THESE INSTRUCTIONS FOR FUTURE USE.
CAUTION:
IF YOU USE THIS HEATER IN CONJUNCTION WITH A THERMAL CONTROL, A PROGRAM CONTROLLER, A TIMER OR ANY OTHER DEVICE THAT SWITCHES THE HEATER ON AUTOMATICALLY, REMEMBER TO OBSERVE ALL SAFETY WARNINGS AT ALL TIMES. THE FIREPLACE HEATER HAS SAFET Y OVERHEAT PROTECTION. IF THE OVERHEAT PROTECTION TRIPS, SWITCH OFF ALL SWITCHES AND WAIT APPROXIMATELY 5–10 MINUTES. IT SHOULD RESET AUTOMATICALLY ONCE THE UNIT COOLS DOWN.
WARNING:
PROCEDURES AND TECHNIQUES, IF NOT CAREFULLY FOLLOWED, WILL RESULT IN DAMAGE TO THE EQUIPMENT, AND WILL EXPOSE THE USER TO THE RISK OF SERIOUS INJURY, ILLNESS OR DEATH.
1
Page 2
THIS ELECTRIC FIREPLACE HEATER IS FOR USE ON 120 VOLTS. THE CORD HAS A PLUG, AS SHOWN AT A IN ILLUSTRATION BELOW. AN ADAPTER, AS SHOWN AT C, IS AVAILABLE FOR CONNECTING THREE-BLADE GROUNDING-TYPE PLUGS TO TWO-SLOT RECEPTACLES. THE GREEN GROUNDING PLUG EXTENDING FROM THE ADAPTER MUST BE CONNECTED TO A PERMANENT GROUND SUCH AS A PROPERLY GROUNDED OUTLET BOX. THE ADAPTER SHOULD NOT BE USED IF A THREE-SLOT GROUNDED RECEPTACLE IS AVAILABLE.
A 15 AMP CIRCUIT IS REQUIRED TO OPERATE THIS HEATER. IF THE BREAKER TRIPS WHEN THE HE ATER IS USED, YOU MAY NEED TO MOVE THE HEATER TO ANOTHER LOCATION OR UNPLUG OTHER APPLIANCES THAT ARE ON THE SAME CIRCUIT. IF YOU REQUIRE AN E XTENSION CORD, USE ONE THAT IS RATED AT 1875 WAT TS.
PARTS LIST:
Fireplace insert..................................................................................................... 1
A) Top panel ........................................................................................................ 1
B) Base panel ...................................................................................................... 1
C) Front upper panel ............................................................................................ 1
D) Left upper front panel ...................................................................................... 1
E) Right upper front panel .................................................................................... 1
F) Left lower front panel ....................................................................................... 1
G) Right lower front panel ..................................................................................... 1
H) Left uppper side panel ..................................................................................... 1
J) Right upper side panel ..................................................................................... 1
K) Left lower side panel ........................................................................................ 1
L) Right lower side panel ...................................................................................... 1
M) Front lower panel ............................................................................................. 1
P) 3-holes wood connectors .................................................................................2
Q) 4-holes wood connectors ................................................................................ 2
R) Mounting feet .................................................................................................. 2
S) Screws for mounting feet ................................................................................. 8
T) Short screws .................................................................................................. 2
U) Mounting clips ................................................................................................. 2
V) Mounting brackets .......................................................................................... 2
W) Screws ......................................................................................................... 56
X) Plastic connectors ........................................................................................ 12
Y) SELF REPAIR SE T
Touch-up repair paint (bottle) ........................................................................... 1
L-shape bracket .............................................................................................. 2
Screws for L bracket ....................................................................................... 8
Plastic connectors .......................................................................................... 1
Screws ........................................................................................................... 3
Nuts ............................................................................................................... 3
Z) WALL ANCHOR SAFETY CABLE
Wall anchor ..................................................................................................... 1
Screw for wall anchor ...................................................................................... 1
Screw for mantel ............................................................................................. 1
Security cable.................................................................................................. 1
Z1) Foam tape (for fireplace insert - not shown) ...................................................... 2
TOOLS REQUIRED: PHILLIPS SCREWDRIVER
BACK
MANTEL ASSEMBLY:
CAUTION: Place a piece of cardboard or protective sheet on the floor in order to avoid scratching the decorative surface of your mantel during assembly.
Please DO NOT fully tighten the screws until all panels are assembled.
NOTE: Each plastic connector is pre-assembled (pre-drilled ) on the specific panels with 2 screws. If the screw( s) do not fit during assembly, loosen the 2 ( pre-drilled) screws to adjust the plastic connector until the screws are able to be installed. Tighten all screws once all panels are assembled.
2
Page 3
Attach 10 plastic connectors (X ) to panels F, G, H, J, K and L, as shown in Fig. A
Step 1:
(2 pcs screws for each connector). Attach panel K and panel H together with 4-holes wood connector (Q ) and 4 screws (W ). At tach panel l and panel J together with 4-holes wood connector ( Q) and 4 screws ( W). Attach panel F and panel D together with 1 screw ( W). Attach panel G and panel E together with 1 screw (W). Attach 2 – 3-holes wood connectors (P), one at each side, to panel C with 4 screws (W) (2 screws for each 3-holes wood connector).
Fig. A BACK
Step 3: Attach the left (D, F, H and K) and right (E, G, J and L) side panels to the base
panel (B) using 4 screws (W) ( 2 screws on each side). See Fig C.
Fig. C BACK
Step 4: Attach tthe front lower panel (M ) to the left front lower panel (F) and right front
lower panel ( G) with 2 screws (1 screw on each side). See Fig. D.
Step 2: Attach the left side panel (H and K) to the left front panel (D and F) with 2
screws (W). Attach the right side panel (J and L) to the right front panel (E and G) with 2 screws (W). See Fig. B.
Fig. B BACK
NOTE: If the screw(s) do not fit during assembly, loosen the 2 screws to adjust the plastic connector until the panels/screws can be installed.
Fig. D BACK
Step 5: Attach the front upper panel (C ) to the left and right front upper panel (D and E)
with 2 screws ( W) (1 screw on each side). See Fig. E.
Fig. E BACK
3
Page 4
Step 6: Attach 2 plastic connectors (X) on the upper side of front upper panel ( C) with 4
screws (W) ( 2 at each plastic connector). See Fig F.
Fig. F BACK
Step 7: Install the top panel (A) to the unit, as shown and attach with 4 screws (W). See Fig. G.
Step 10: Make sure that the foam tape is completely covering both, the side flanges,
as shown in Fig. I.
Fig. I BACK
Step 11: Attach 2 mounting feet ( R) to fireplace inser t (one on each side) with 8
mounting feet screws (S ) (4 screws in each mounting foot). See Fig. J.
Fig. G BACK
Step 8: Foam tape (Z1) has been provided to protect your fireplace mantel. Remove the
backing paper from the foam tape.
Step 9: Attached the foam tape to the left and right side flanges of the insert, as shown
in Fig. H. The foam tape shall be spaced about 10 – 15 mm (0.4 – 0.6 in ) from the front edge of the insert.
Fig. H
Fig. J BACK
St ep 12: Carefully place the insert in the unit opening. The front of insert should be flush with
the front of the mantel. Carefully lift the insert into the mantel until the top stopper is against to mantel. Attach 2 mounting clips (U) to the top side of the insert with 2 short screws (T). Attach 2 mounting brackets (V) to the mounting feet (R) and attach to the base with 2 screws (W). See Fig. K
Fig. K BACK
Step 13: Tighten all screws.
Step 14: Move assembled unit to desired location. Unit should not be positioned in area exposed
to direct sunlight.
.
4
Page 5
WALL ANCHOR SAFETY CABLE
The use of wall anchor safety cable is highly recommended in order to reduce the risk of the fireplace being tipped over accidentally.
WARNING : THIS CABLE MAY REDUCE POSSIBLE RISK OF INJURY IF THE FIREPL ACE IS IMPROPERLY HANDLED, BUT IS NOT A SUBSTITUTE FOR PROPER ADULT SUPERVISION. CHILDREN SHOULD NOT BE LEFT UNATTENDED NEAR ANY HEATER.
1. Drill a 8 mm (5/16 in) hole in the wall. Insert the plastic wall anchor into the hole and gently tap until the flange on the anchor is against the wall surface.
2. Position the back edge of the mantel close to the wall.
3. Attach the safety cable to the mantel using the screw for mantel.
4. Use the screw for wall to attach the other end of safety cable to the wall.
5. Make sure all screws are tight.
WAL L
O/I : Press this switch for main power and flame effect. The indicator light will turn on. See below for other control switches.
750W: For low heat function, press this switch while the O/ I switch is in the ON position. The indicator light will turn ON.
1500W : For high heat function, press this switch while the O/I switch and the 750W switch are in the ON position. The indicator light will turn ON.
TEMPERATURE CONTROL: To adjust the temperature to your individual requirements, turn the temperature control dial to the right (clockwise ) to increase the desired temperature and to the left for lower temperature. This temperature control dial can only be used while the O/I switch and 750W and 1500W switches are in the ON position.
DIMMER CONTROL KNOB: Turn the dimmer dial clockwise or counter clockwise to get the desired flame intensity. The dimmer switch can only be used when the O /I switch is in the on position.
NOTE: When the O/Iswitch is turned off, all other heater functions will stop even though the switches may be in the ON position.
MAINTENANCE
WARNING : DISCONNECT POWER AND UNPLUG THE POWER CORD BEFORE ATTEMPTING ANY MAINTENANCE OR CLEANING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR DAMAGE TO PERSONS. THE BULBS IN YOUR UNIT CAN BECOME EXTREMELY HOT.
Allow at least 10 minutes between turning off the unit and removing the light bulbs to avoid the accidental burning of the skin.
RISK OF FIRE: DO NOT EXCEED THE RECOMMENDED BULB WATTAGE.
OPERATION
After reading complete instructions, confirm all controls on fireplace are in the OFF position. Plug the fireplace into a 15AMP/120Volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 WATTS. Once the fireplace insert has been properly connected to a grounded electrical outlet, it is ready to operate.
OPERATION BY THE CONTROL PANEL
The controls are located behind the grill below the front glass and can be accessed by pulling the grill from the top, forward and down.
WARNING : DO NOT TOUCH HOT SURFACE AT CENTRE OF GRILL, HANDLE, LEFT OR RIGHT SIDE OF GRILL WHEN PULLING OUT.
REPLACING THE FLAME EFFECT LIGHT AND LOG-SET LIGHT BULBS
Step 1: Remove the 4 screws on the back of fireplace and open the rear cover.
Step 2: You will find a 1 x 40W type B-10 bulb under log-set bed.
Step 3: Loosen and remove the burnt out bulb and replace with a new bulb.
Step 4: Close the rear cover and secure with the 4 screws.
Step 5: Plug in the unit.
5
Page 6
REPAIR SET
TOUCH-UP REPAIR PAINT
2. Drill the holes with diameter 10 mm (3 /4 in) and depth 10 mm (3 /4 in) Each plastic connector needs 3 holes. See Fig. B.
on the mantel.
Paint directly on the mantel unit if necessary.
REPAIRS
If any problems are found with the original parts during mantel assembly, such as if the panels cannot be installed with the plastic connector, try to solve by one of the following methods.
Tools required: Electric drill, drill bits 10 mm (3 /4 in) or 2 mm (1/16 in), pencil, hammer, Phillips screwdriver, safety goggles and gloves (if necessary).
WARNING : WEAR GOGGLES BEFORE YOU START DRILLING.
OPTION 1:
Use the spare nuts, screws and plastic connector.
1. Place the plastic connector on the mantel unit and mark the drill-holes, as shown in Fig. A.
Fig. B Fig. C
3. Gently install the nuts into the drilled-holes with hammer, as shown in Fig. C.
4. Attach the plastic connector and lock in place with screws, as shown in Fig. D.
Fig. D
OPTION 2:
Use the small L-brackets and screws.
1. Place the small L-bracket to the unit and mark the drill holes on the mantel, as shown in Fig. E.
Fig. A
Fig. E
6
Page 7
2. Drill the holes with diameter 2 mm (1/16 in) and depth 8 mm ( 5/16 in) on the mantel. Each small L-bracket needs 4 holes. See Fig. F.
Fig. F Fig. G
3. Attach the small L-bracket and lock in place with screws, as shown in Fig. G.
CLEANING
To clean the unit, first turn off the controls on the unit and unplug the unit from power source. To clean glass display panel, remove dust with a clean dry cloth. To remove finger prints and other marks, clean glass with a clean damp cloth. Do not use abrasive cleaners or spray liquids on glass display panel surface. Metal and metal painted parts should be cleaned with a damp cloth. Do not use abrasive cleaners or spray liquids on these surfaces.
WARRANTY
Every electric fireplace heater is tested before it leaves the factory and it is guaranteed for one year. If the unit should fail to operate correctly within one year from the date of purchase, please go to our website www.qualitycraft.com and click on customer support. We will, at our discretion, either repair or replace the unit. It will have to be returned to us freight prepaid and we will return the repaired or replaced unit to you freight prepaid. The company’s sole obligation is to repair or replace the unit.
WARRANTY CLAIM PROCEDURE
If a claimable defect occurs, please fill out a claim form through our website at www.qualit ycraft.com and click on customer support.
Before you make your claim, please make sure you have:
1. The description of the electric fireplace
2. Proof of sale
3. Details regarding the defect
4. Name and address of the owner
Claims must be filled out in writing and returned within six (6) months of appearance of defect. Failure to comply with this stipulation will make the warranty null and void. We reserve the right to a thirty-day ( 30) delay following receipt of claim in which to inspect the product. We assume no responsibility for labor costs, removing/replacing a previously installed product, transportation, or return of a product.
REPLACEMENT PARTS
ITEM PART # QTY
Self repair kit RE-KIT 1
Wall anchor safet y cable SA-Cab#1 1
Hardware kit
P) 3-holes wood connectors ............... 2
Q) 4-holes wood connectors ............... 2
R) Mounting feet .................................2
T) Short screws .................................. 2
U) Mounting clips ...............................2
870P-28- HW K#1 1
Imported by
Quality Craft
Laval, Quebec, Canada H7C 0A5 1-800-459-4409 (EST) (Monday to Friday, 8:30am to 5:00pm, EST )
www.qualitycraft.com
Made in China
7
Loading...