Read and understand these instructions before using equipment!
Page 2
Page 3
Table of Contents
Introduction
Applicable Safety Standards
Worker Classifications
Safety Information
Maintenance, Cleaning, and Storage
Inspection
Product Specific Applications
Limitations
Components and Specifications
Installation and Use
Labels
Inspection Log
Notes
1-2
2
2
3-4
5
5
6
7-10
11-12
12-15
16
17
17
Introduction
Thank you for purchasing a Guardian Fall Protection Permanent Adjustable Standing Seam Roof
Anchor. This manual must be read and understood in its entirety, and used as part of an
employee training program as required by OSHA or any applicable state agency.
This and any other included instructions must be made available to the user of the equipment.
The user must understand how to safely and effectively use the Permanent Adjustable Standing
Seam Roof Anchor, and all fall safety equipment used in combination with the Permanent
Adjustable Standing Seam Roof Anchor.
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
1
Page 4
User Information
Date of First Use:
Serial #:
Trainer:
User:
Applicable Safety Standards
When used according to instruction specifications, this product meets or exceeds all applicable
OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.1-2007, and ANSI A10.32-2012 standards for fall
protection. Applicable standards and regulations depend on the type of work being done, and
also might include state-specific regulations. Consult regulatory agencies for more information
on personal fall arrest systems and associated components.
Worker Classifications
CAUTION
!
Qualified Person: A person with an accredited degree or certification, and with extensive
experience or sufficient professional standing, who is considered proficient in planning and
reviewing the conformity of fall protection and rescue systems.
Competent Person: A highly trained and experienced person who is ASSIGNED BY THE EMPLOYER
to be responsible for all elements of a fall safety program, including, but not limited to, its
regulation, management, and application. A person who is proficient in identifying existing and
predictable fall hazards, and who has the authority to stop work in order to eliminate hazards.
Authorized Person: A person who is assigned by their employer to work around or be subject to
potential or existing fall hazards.
It is the responsibility of a Qualified or Competent person to supervise the job site and
ensure all applicable safety regulations are complied with.
Understand the following definitions of those who
work near or who may be exposed to fall hazards.
2
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
Page 5
Safety Information
Failure to understand and comply with safety regulations may result in
WARNING
!
Do not alter equipment.
Do not misuse equipment.
Workplace conditions, including, but not limited to, flame, corrosive chemicals, electrical shock,
sharp objects, machinery, abrasive substances, weather conditions, and uneven surfaces, must
be assessed by a Competent Person before fall protection equipment is selected.
The analysis of the workplace must anticipate where workers will be performing their duties,
the routes they will take to reach their work, and the potential and existing fall hazards they
may be exposed to.
Fall protection equipment must be chosen by a Competent Person. Selections must account for
all potential hazardous workplace conditions.
All fall protection equipment should be purchased new and in an unused condition.
Fall protection systems must be selected and installed under the supervision of a Competent
Person, and used in a compliant manner.
Fall protection systems must be designed in a manner compliant with all federal, state, and
safety regulations.
serious injury or death. Regulations included herein are not all-inclusive,
are for reference only, and are not intended to replace a Competent
Person’s judgment or knowledge of federal or state standards.
Unless explicitly stated otherwise, the maximum allowable free fall distance for lanyards must
not exceed 6’. No free fall allowed for non-LE SRLs. Class A SRLs must arrest falls within 24”;
Class B SRLs must arrest falls within 54”.
Forces applied to anchors must be calculated by a Competent Person.
Harnesses and connectors selected must be compliant with manufacturer’s instructions, and
must be of compatible size and configuration.
A pre-planned rescue procedure in the case of a fall is required. The rescue plan must be projectspecific. The rescue plan must allow for employees to rescue themselves, or provide an
alternative means for their prompt rescue.
Store rescue equipment in an easily accessible and clearly marked area.
Training of Authorized Persons to correctly erect, disassemble, inspect, maintain, store, and use
equipment must be provided by a Competent Person.
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
3
Page 6
Training must include the ability to recognize fall hazards, minimize the likelihood of fall hazards,
and the correct use of personal fall arrest systems.
NEVER use fall protection equipment of any kind to hang, lift, support, or hoist tools or
equipment, unless explicitly certified for such use.
Maintenance of equipment must be done according to manufacturer’s instructions. Equipment
instructions must be retained for reference.
Prior to EACH use, all equipment in a fall protection system must be inspected for any potential
or existing deficiencies that may result in its failure or reduced functionality. IMMEDIATELY
remove equipment from service if any deficiencies are found.
Equipment must be inspected by a Competent Person at least every six months. These
inspections must be documented in equipment instruction manual and on equipment inspection
grid label.
Equipment must be inspected for defects, including, but not limited to, the absence of required
labels or markings, improper form/fit/function, evidence of cracks, sharp edges, deformation,
corrosion, excessive heating, alteration, excessive wear, fraying, knotting, abrasion, and absence
of parts.
Equipment that fails inspection in any way must immediately be removed from use, or repaired
by an entity approved by the manufacturer.
No on-site repair of equipment unless explicitly permitted by Guardian Fall Protection.
Equipment subjected to forces of fall arrest must immediately be removed from use.
Snap hooks, carabiners, and other connectors must be selected and applied in a compatible
fashion. All risk of disengagement must be eliminated. All snap hooks and carabiners must be
self-locking and self-closing, and must never be connected to each other.
Age, fitness, and health conditions can seriously affect the worker should a fall occur. Consult a
doctor if there is any reason to doubt a user’s ability to withstand and safely absorb fall arrest
forces or perform set-up of equipment.
Pregnant women and minors must not use this equipment.
Physical harm may still occur even if fall safety equipment functions correctly. Sustained post-fall
suspension may result in serious injury or death. Use trauma relief straps to reduce the effects of
suspension trauma.
Allowable individual worker weight limit (including all equipment), unless explicitly stated
otherwise, is 130-310 lbs.
4
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
Page 7
Maintenance, Cleaning, and Storage
Repairs to Permanent Adjustable Standing Seam Roof Anchors can only be made by a Guardian
Fall Protection representative or an entity authorized by Guardian. Contact Guardian for all
maintenance and repair needs at: 1-800-466-6385. If a Permanent Adjustable Standing Seam
Roof Anchor fails inspection in any way, immediately remove it from service, and contact
Guardian to inquire about its return or repair.
Cleaning after use is important for maintaining the safety and longevity of Permanent Adjustable
Standing Seam Roof Anchors. Remove all dirt, corrosives, and contaminants from Permanent
Adjustable Standing Seam Roof Anchors before and after each use. If Permanent Adjustable
Standing Seam Roof Anchor cannot be cleaned with plain water, use mild soap and water, then
rinse and wipe dry. NEVER clean Permanent Adjustable Standing Seam Roof Anchors with
corrosive substances.
When not in use, store equipment where it will not be affected by heat, light, excessive
moisture, chemicals, or other degrading elements.
Inspection
KEEP INSTRUCTIONS AVAILABLE FOR REFERENCE. Record Date of First Use.
Prior to EACH use, inspect Permanent Adjustable Standing Seam Roof Anchor for deficiencies,
including, but not limited to, corrosion, deformation, pits, burrs, rough surfaces, sharp edges,
cracking, rust, paint buildup, excessive heating, alteration, and missing or illegible labels.
IMMEDIATELY remove Permanent Adjustable Standing Seam Roof Anchor from service if defects
or damage are found, or if exposed to forces of fall arrest.
Ensure that applicable work area is free of all damage, including, but not limited to, debris, rot,
rust, decay, cracking, and hazardous materials. Ensure that selected work area will support the
application-specific minimum loads set forth in this instruction manual. Work area MUST be
stable.
At least every 6 months, a Competent Person other than the user must inspect Permanent
Adjustable Standing Seam Roof Anchors. Competent Person inspections MUST be recorded in
inspection log in instruction manual and on equipment inspection grid label. The
Competent Person must sign their initials in the box corresponding to the month and year
the inspection took place.
During inspection, consider all applications and hazards Permanent Adjustable Standing Seam
Roof Anchors have been subjected to.
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
5
Page 8
Product Specific Applications
WARNING
!
Personal Fall Arrest: Permanent Adjustable Standing Seam Roof Anchors may be
used to support a MAXIMUM 1 Personal Fall Arrest System (PFAS) for use in Fall
Arrest applications. Structure must withstand loads applied in the directions
permitted by the system of at least 5,000 lbs. Maximum free fall is 6‘, or up to 12’
if used in combination with equipment explicitly certified for such use. Applicable
D-ring: Dorsal.
Restraint: Permanent Adjustable Standing Seam Roof Anchors may be used in
Restraint applications. Restraint systems prevent workers from reaching the leading
edge of a fall hazard. Always account for fully deployed length of lanyard/SRL.
Structure must withstand loads applied in the directions permitted by the system of
at least 1,000 lbs. No free fall is permitted. Restraint systems may only be used on
surfaces with slopes up to 4/12 (vertical/horizontal). Applicable D-rings: Dorsal,
Chest, Side, Shoulder.
Work Positioning: Permanent Adjustable Standing Seam Roof Anchors may be
used in Work Positioning applications. Work Positioning systems allow a worker to
be supported while in suspension and work freely with both hands. Structure must
withstand loads applied in the directions permitted by the system of at least
3,000 lbs. Maximum allowable free fall is 2’. Applicable D-rings: Side, Shoulder.
Use of equipment in unintended applications may result in serious
injury or death. Maximum 1 attachment per connection point.
For all applications: worker weight capacity range
(including all clothing, tools, and equipment) is 130-310 lbs.,
or up to 420 lbs. if used in combination with
equipment explicitly certified for such use.
6
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
Page 9
Limitations
Fall Clearance: There must be sufficient clearance below the anchorage connector to arrest a fall
before the user strikes the ground or an obstruction. When calculating fall clearance, account for
a MINIMUM 3’ safety factor, deceleration distance, user height, length of lanyard/SRL, and all
other applicable factors. Diagram shown is an example fall clearance calculation ONLY.
FALL CLEARANCE CALCULATION
Lanyard length
(6’ total)
Required
distance
from
anchorage
(19’ total)
Deceleration
distance (4’ total)
Height of harness
dorsal D-ring from
worker’s feet
(6’ total)
Safety factor
(3’ total)
Swing Falls: Prior to installation or use, make considerations for eliminating or minimizing all
swing fall hazards. Swing falls occur when the anchor is not directly above the location where a
fall occurs. Always work as close to in line with the anchor point as possible. Swing falls
significantly increase the likelihood of serious injury or death in the event of a fall.
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
7
Page 10
Compatibility: When making connections with Permanent Adjustable Standing Seam Roof
Anchors, eliminate all possibility of roll-out. Roll-out occurs when interference between a hook
and the attachment point causes the hook gate to unintentionally open and release. All
connections must be selected and deemed compatible with Permanent Adjustable Standing
Seam Roof Anchors by a Competent Person. All connector gates must be self-closing and
self-locking, and withstand minimum loads of 3,600 lbs. See the following for examples of
compatible/incompatible connections:
Connector
closed and
locked to
D-ring. OK.
Two or more
snap hooks or
carabiners
connected to
each other. NO.
Two connectors
to same
D-ring. NO.
Incompatible
or irregular
application,
which may
increase risk
of roll-out. NO.
Connector
to integral
lanyard.
NO.
Connector
directly to
webbing.
NO.
Application
that places
load on gate.
NO.
Connector
directly to
horizontal
lifeline. NO.
8
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
Page 11
Correct Anchorage Positioning:
This chart details allowable working zones required
to reduce risk of swing falls and improper side loading.
ALWAYS adhere to information specified by chart.
Anchor Distance
From
Leading Edge (Y)
6’
10’
15’
20’
25’
30’
35’
40’
45’
50’
55’
60’
For example, if the anchorage connector is 6’ from the leading
edge (Y), the working distance (X) is 8’ in each direction from
the perpendicular, which translates to a 53° working angle.
Key:
X: Working Distance
Along Roof Edge
Y: Distance From
Leading Edge
Ø: Total Working
Angle
Working Distance
Along Roof Edge
(Either Direction) (X)
8’
9’ - 9”
11’ - 7”
13’ - 3”
14’ - 6”
16’
17’ - 2”
18’ - 3”
19’ - 4”
19’ - 10”
21’ - 4”
22’ - 3”
Y
Working Angle
From
Perpendicular (Ø)
53°
45°
38°
33°
30°
28°
26°
24°
23°
21°
21°
21°
Ø
X
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
9
Page 12
Ultraseam US 175LS
Panel
Panel
Manufac turer
Material
Name
Thick ness
A
B
B
C
C
C
C
Custom Built
Custom Built Metals
D
D
D
D
D
E
E
E
Material
Manufac turer
Thick ness
Panel
Panel
Name
E
E
E
E
E
E
F
R
F
F
F
G
G
G
G
I
I
I
I
I
Grobgekoemt Snap
I
K
K
Manufac turer
Name
Thick ness
Panel
Panel
Material
Machinery
Manufac turer
Thick ness
Name
N
M
N
M
N
N
O
O
P
Prefalz 25 mm DFSS
R
R
S
S
S
B
S
B
S
B
T
Tegral Metal Form Tegral Alu-Seam 0.9mm Aluminum
Manufac turer
Name
Thick ness
T
U
U
U
C
U
C
V
Z
Z
Z
Z
Thick ness
Manufac turer
Name
Incompatible Roof Seams:
Prior to installation, refer to the table below to determine if the Permanent Adjustable
Standing Seam Roof Anchor is incompatible with the selected roof seam. If selected roof
seam appears on table, DO NOT install the Permanent Adjustable Standing Seam Roof
Anchor.
WARNING
!
AB Martin Roofing AB Seam 19.524 ga steel
AEP SpanKlip Rib24 ga steel
Alcan/NovelisFalzonal 25mm 0.7mm Alumi num
Architectural Metal Ultra Seam US200S 0.4 Aluminum
Products
Architectural Metal AMS 175 1--3/4" 0.032 Aluminum
Specialties, Inc. Snap-Lock
Architectural Metal AMS200 2"0.4 Aluminum
Specialties, Inc. Mechanical Lock
Architectural Metal Ultraseam US 200S 0.4 Aluminum
Specialties, Inc. 2" Mechanical Lock
Architectural Metal
Specialties, Inc. Snap-Lock
Armor Building Armor Clip26 ga steel
Supply
ASC BuildingSkyline26 ga steel
Products
ATASDutch Seam24 ga steel
ATASDutch Seam0.4 Aluminum
KMETECU Zin 25mm 0.7 mm Copper
McElroy Metals Maxima 2"0.032 Alu minum
McElroy Metals Meridian24 ga steel
McElroy Metals Meridian26 ga steel
McElroy Metals Mirage24 ga steel
Merchant & Evans Zip Rib1mm Zinc
Metal FabMetFab Historic 0.032 Aluminum
ManufacturingPanel 1.5" (DBF)
Metal FabMetFab III Panel 0.032 Aluminum
Manufacturing(DBF)
Metal FabMetFab0.032 Aluminum
ManufacturingSnapOn 675
NedZinkNATUREL 24mm 0.7 mm
New TechSS 1500.032 Alum inum
Machinery(Double Fold)
New TechSS 210A0.032 Aluminum
Machinery(Double Fold)
New TechSS 45024 ga steel
Machinery
New TechSS 450 SL24 ga steel
DFSS
degree
90
MRD-150
MRD-150
Panel PanelM aterial
DFSS
Double Fold
0.032 Aluminum
10
NEVER attach Permanent Adjustable Standing
Seam Roof Anchor to incompatible roof seams.
TASDutch Seam 0.032 Aluminum
EMOVF Profile1mm Aluminum
ryer Company TBS Superseam 0.032 Aluminu m
oated MetalsUltra Flange 1.0 24 ga steel
oated MetalsUltra Flange 1.0 26 ga steel
orusFalzine0.7 mm Alumi num
orusKalzip 650.9 mm Alumi num
rexel MetalsDMC 150 SS (DBF) 0.032 Aluminum
rexel MetalsDMC 150 SL24 ga steel
rexel MetalsDMC 150 SL26 ga steel
rexel MetalsDMC 175S Snap 0.032 Al uminum
achinery1--3/4"
U RaySeries 100024 ga steel
U RaySeries 100026 ga steel
C MetalsOCM 150 SL24 ga steel
C MetalsOCM 150 SL26 ga steel
refa
heinzinkPreweathered0.8 Zinc
heinzinkTizn 25mm DFSS 0.7 Zinc
chlebach1.5 Nail Strip24 ga steel
Zinc
chlebach1.5 Nail Strip26 ga steel
peedDeckSpeedDeck0.6mm ste el
uilding Systems Interm ediate Rib
peedDeckSpeedDeck0.9mm Aluminum
uilding Systems Interm ediate Rib
peedDeckSpeedDeck0.9mm Aluminum
uilding Systems Lapped Rib
nglertSeries 15000.032 A luminum
nglertSeries 150024 ga steel
nglertSeries 20000.032 A luminum
nglertSeries 24000.032 A luminum
nglertSeries 2500 (DBF) 0.0 32 Aluminum
verlast Roofing Inc.Everseam24 ga steel
ielders SteelKingKlip 7000.5mm steel
oofing(Intermediate Rib)
irestoneUC30.04 Aluminum
ollansbee Steel 1" (25mm) DF TCSII 28 ga ss steel
uture RoofSnap Lock 1"26 ga steel
arlandR-Mor Loc0.032 Al uminum
arlandR-Mor Loc0.04 Al uminum
arlandR-Mor Span0.032 Alum inum
arlandR-Mor Span0.04 Alum inum
metcoSeries 3000.032 Alum inum
metcoSeries 3000.04 Alum inum
metcoSnap Lok 1--3/4" 0.032 Alumi num
metcoSnap Lok 1--3/4" 0.04 Alumi num
mpol
nterlock Roofing Snap Lock 1"0.027 Aluminum
ingspan UKKingZip0.9m m Aluminum
METECU 25mm DFSS 0.7 mm Copper
anel Panel
P
remcoTremLock VP0.032 Alumi num
micore/VM Zinc Tizn 25mm DFSS 0.7mm Zinc
na CladUC30.04 Aluminum
nion Corrugating Advantage Lok II 24 ga steel
ompany
nion Corrugating SL 15024 ga steel
ompany
ic West CaPrestige24 ga steel
intek Srl24mm Doubl e 0.7mm Zinc
intek Srl24mm Doubl e 0.8mm Zinc
intek Srl38mm Doubl e 0.7mm Zinc
intek Srl38mm Doubl e 0.8mm Zinc
Standing Seam
Standing Seam
Standing Seam
Standing Seam
1 mm Aluminu m
Material
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
Page 13
Components and Specifications
Some assembly of components is necessary prior to installation and use of Permanent
Adjustable Standing Seam Roof Anchor. Always use fasteners provided by Guardian Fall
Protection. Components are manufactured from the following materials:
Large Tie-Off Bar: Aluminum Seam Bar (2): Aluminum
Tie-Off Tab: Stainless Steel S-5 Clamp (8): Aluminum
• (2) Set Screws are provided with each S-5 clamp. S-5 Clamps are designed with four Set
Screw holes for increased versatility, but require only two Set Screws for proper
installation of the Permanent Adjustable Standing Seam Roof Anchor.
Seam Bar
x1 per side (L/R)
Tie-Off
Tab
LR
Large
Tie-Off Bar
S-5 Clamp
x4 per side (L/R)
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
11
Page 14
For all fasteners, torque to 25-30
foot-pounds and ensure that MINIMUM
1 complete bolt thread is visible.
1. Install Tie-Off Tab to Tie-Off Bar. Insert 2”
long, 5/8”-18 Bolt through Tie-Off Tab bolt
hole, through washer, through Tie-Off Bar,
and secure with lock nut. Tighten lock nut
against underside of Tie-Off Bar. Tie-Off Tab
must swivel freely a full 360°.
2. Install all (8) S-5 Clamps (4 per Seam Bar) onto
Seam Bars prior to installation of Seam Bars onto
Tie-Off Bar. Insert bolt through washer, through
Seam Bar, and through one of top two S-5 Clamp
holes. One bolt and one washer per S-5 Clamp.
Top ViewBottom View
Installation and Use
A Qualified Person is responsible for the installation of the Permanent Adjustable
Standing Seam Roof Anchor, and must verify both standing seam and existing structure
meet all compatibility and minimum strength requirements as specified by this
instruction manual. Anchor is intended for permanent installations, but may be used in
multiple installations. Always use new nylock nuts for each installation application.
Prior to installation:
1. Ensure make, model, and material of selected roof seam are compatible with the Permanent
Adjustable Standing Seam Roof Anchor (refer to pg. 8). Measure intended installation location of
Permanent Adjustable Standing Seam Roof Anchor. Contact Guardian Fall Protection with any
questions regarding compatibility.
2. All PFAS equipment must be selected and deemed compatible with the Permanent Adjustable
Standing Seam Roof Anchor by a Competent Person.
3. Work surface must be free of any and all deficiencies, including, but not limited to, corrosion,
rust, deformation, cracking, debris, and loose materials that may infringe upon the stability of
the Permanent Adjustable Standing Seam Roof Anchor.
4. Consider and minimize all existing and potential swing fall hazards.
5. When used in Fall Arrest applications, harness dorsal D-ring must ALWAYS remain level with or
below Permanent Adjustable Standing Seam Roof Anchor.
12
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
Page 15
Installation:
1. 3/16” Allen wrench attachment tip (provided with S-5 Clamps) is required for installation
of Permanent Adjustable Standing Seam Roof Anchor. To install, attach Allen wrench
attachment to compatible 1/4” drive screw gun.
2. Adjust Permanent Adjustable Standing Seam Roof Anchor to match roof seam spacing.
Compatible with roof seams from 12” - 24” apart. Tighten all (4) bolts on Tie-Off Bar to 25-30
foot-pounds.
3. Place all S-5 Clamps over selected roof seams. S-5 Clamps and Seam Bars MUST be
perpendicular to roof edge. Both sets of S-5 Clamps must be the same distance from roof
edge.
25-30
ft.-lbs.
12” - 24”
Roof Edge
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
13
Page 16
4. Insert Set Screws in bottom two holes of all S-5 Clamps. All Set Screws must face same
direction. Ensure all Set Screws will compress against roof seam when fully installed.
Roof Seam
Set Screws
must compress
against roof seam.
5. Use 3/16” Allen wrench attachment (provided with S-5 Clamps) with compatible 1/4” drive
screw gun to install Set Screws.
• If roof material is 22 gauge or thicker, torque all S-5 Clamp Set Screws to
between 13.33-15 foot-pounds.
• If roof material is thinner than 22 gauge, torque all S-5 Clamp Set Screws to
between 10.83-12.5 foot-pounds.
WARNING
!
NEVER over-torque set-screws; doing so could
strip hardware or damage roof panels.
14
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
Page 17
6. As installation of Set Screws progresses, torque values of already installed Set Screws may
change as tension on roof seam increases. As necessary, re-torque Set Screws until all Set Screws
are within torque range specified by this instruction manual. Measure Set Screw torque with
torque wrench.
When applying torque to Set Screws, ensure that selected drive screw
WARNING
!
gun (with 3/16” Allen wrench attachment) is applying consistent and
adequate torque. Prior to each use, ALWAYS use properly calibrated
torque wrench to ensure all Set Screws are adequately torqued.
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
15
Page 18
Labels
INSPECTION GRID
20____
20____
20____
20____
20____
YRJ F M A M JJ A S O N D
Date of First Use: __________________. Product lifetime is indefinite as
long as equipment passes pre-use and Competent Person inspections.
If equipment fails inspection
IMMEDIATELY REMOVE FROM SERVICE
DO NOT REMOVE LABELS
User must inspect prior to EACH use. Competent Person must complete
formal inspection every 6 months. Competent Person to inspect and initial.
User must inspect prior to EACH use. Competent Person must complete
formal inspection every 6 months. Competent Person to inspect and initial.
Date of First Use: __________________. Product lifetime is indefinite as
long as equipment passes pre-use and Competent Person inspections.
YR J F M A M J J A S O N D
20____
20____
INSPECTION GRID
20____
20____
20____
If equipment fails inspection
IMMEDIATELY REMOVE FROM SERVICE
www.guardianfall.com
1-800-466-6385
6305 S. 231st St.
Kent, WA 98032
90027 (Rev. C)
Permanent Adjustable Standing Seam Roof Anchor
Part #: 00249Date of manufacture:
Compliant with all OSHA 1910, 1926 Subpart M,
ANSI Z359.1-2007, and ANSI A10.32-2012 regulations.
Prior to use, read and understand all manufacturer’s
instructions provided with equipment at
time of shipment from manufacturer.
Material: Aluminum and stainless steel.
Worker capacity: 130-310 lbs. (including all equipment)
unless used with system components certified for up to 420 lbs.
All connections must be selected and deemed compatible
with the Permanent Adjustable Standing Seam
Roof Anchor by a Competent Person.
S-5 Set Screw torque requirements:
13.33-15 foot-pounds on 22 gauge steel or thicker,
10.83-12.5 foot-pounds on steel thinner than 22 gauge.
Refer to instructions for installation requirements.
WARNING
Ensure roof seam compatibility prior to installation.
Prior to use, ensure all Set Screws are torqued correctly.
!
Label locations
DO NOT REMOVE LABEL
Prior to use, ensure all Set Screws are torqued correctly.
Ensure roof seam compatibility prior to installation.
Refer to instructions for installation requirements.
130-150 inch-pounds on steel thinner than 22 gauge.
160-180 inch-pounds on 22 gauge steel or thicker,
All connections must be selected and deemed compatible
unless used with system components certified for up to 420 lbs.
!
with the Permanent Adjustable Standing Seam
S-5 Set Screw torque requirements:
Worker capacity: 130-310 lbs. (including all equipment)
WARNING
Roof Anchor by a Competent Person.
Prior to use, read and understand all manufacturer’s
Material: Aluminum, stainless steel, steel.
ANSI Z359.1-2007, and ANSI A10.32-2012 regulations.
Part #: 00249
time of shipment from manufacturer.
instructions provided with equipment at
Permanent Adjustable Standing Seam Roof Anchor
Compliant with all OSHA 1910, 1926 Subpart M,
1-800-466-6385
www.guardianfall.com
Date of manufacture:
90027 (Rev. B)
Kent, WA 98032
6305 S. 231st St.
16
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
Page 19
Inspection Log
User must inspect prior to EACH use. Competent Person other than user must complete
formal inspection at least every 6 months. Competent Person to inspect and initial.
Date of First Use: __________________. Product lifetime is indefinite, as long as it passes
pre-use and Competent Person inspections.
This inspection log must be specific to one Permanent Adjustable Standing Seam Roof
Anchor. Separate inspection logs must be used for each Permanent Adjustable Standing
Seam Roof Anchor. All inspection records must be made visible and available to all users
at all times.
If equipment fails inspection IMMEDIATELY REMOVE FROM SERVICE.
Notes
Guardian Fall Protection 6305 S. 231st St., Kent, WA 98032 phone: (800) 466-6385 fax: (800) 670-7892 www.guardianfall.com
1785021 (Rev. F)
Page 20