Qualcraft Heavy Duty Fixed Roof Bracket User Manual

HEAVY DUTY ROOFING BRACKETS
ROOFING
PRODUCTS
FIXED & ADJUSTABLE Roong Brackets
Durable all steel construction sized to fit specific, common roof pitches. Can be easily installed and removed without damaging shingles. The capacity is one worker per 8 foot staging plus 40lbs., with a maximum of 8 feet between brackets.
For use on 21/12 PITCH ROOFS
Model #2503 6" x 60º
For use on 12/12 PITCH ROOFS
Model #2501 10" x 45º Model #2504 6" x 45º
USE ONLY AS A SLIDEGUARD OR MATERIAL SUPPORT
Model #2502 6" x 90º
FOR USE AS MATERIAL SUPPORT ONLY
Model #2505 4" x 90º
Product Specications
Model # 2501 2502 2503 2504 2505
Description: 10” x 45 Degree 6” x 90 Degree 6” x 60 Degree 6” x 45 Degree 4” x 90 Degree
Unit Pack: 10 / Carton 10 / Carton 10 / Carton 10 / Carton 10 / Carton
Weight per Pack: 23 Pounds / Carton 22.6 Pounds / Carton 22.6 Pounds / Carton 22.6 Pounds / Carton 22 Pounds/Carton
Cu. Ft. per Pack: .52 cu. ft. .99 cu. ft. .63 cu. ft. .63 cu. ft. .63 cu. ft.
© Copyright 2003 • Qual-Craft® Industries • 1551 Central Street
Customer Support and Ordering Information
PO Box 559 • Stoughton, MA 02072
781-344-1000 • www.qualcraft.com
ROOFING PRODUCTS
INSTRUCTIONS FOR INSTALLA­TION AND USE OF THE MODEL #2501 & #3501 10”x 45 DEGREE, MODEL #3504 8” x 45 DEGREE PITCH ROOFING BRACKET (FOR USE ON 12/12 PITCH ROOFS): CAPACITY: One worker per 8 feet of scaffolding plus 40 pounds of materials. GENERAL REQUIRE­MENTS: When installed, the plat-
form support arm must be set to match the pitch of the roof, allowing for the installation of a fully decked and level walk surface. MOUNTING THE ROOF BRACKET: 1) All brack­ets shall be attached to the roof with 20-penny nails. Use all slots on mounting plate. 2) Position bracket so that all nails penetrate both the roof’s surface and the rafter below.
3) Spacing between brackets shall not exceed 8 feet. INSTALLING PLATFORM: 1) wood platforms shall not be less than 2 inches nominal thickness and shall extend beyond the support arm not less than 6 inches and not more than 12 inches.
2) Always use clear, straight-grained wood free from knots or defects. 3) If extended length platforms are re­quired, use additional Roof Brackets every 8 feet. 4) Secure to bracket by nailing the platform to the bracket using the hole provided in the plat­form retainer. INSTRUCTIONS FOR USE: 1) No more than one person shall occupy any given 8 feet of a Roong Bracket Scaffold. 2) Always use OSHA compliant fall arrest sys­tem, guardrails, catch platforms or other safety equipment as required by Local, State or Federal OSHA Regulations. 3) Roof Brackets are intended for use by the experienced tradesman. 4) OSHA Regulations re­quire that employers provide training in the use and care of this product. CARE AND MAINTENANCE: 1) In­spect all Roong Brackets before each use to be sure that there is no damage or deformation, or de­terioration from rusting. Discard if necessary. 2) Do not throw or drop from a building or onto a truck. 3) Do not use if exposed to extreme heat or cold. Discard at once. 4) Do not use if wet or frozen.
60˚ 45˚ 90˚
INSTRUCTIONS FOR INSTALLA­TION AND USE OF THE MODEL #3503 8”x 60 DEGREE FIXE D PI T CH R O OFIN G BRAC K ET (F O R US E ON 21/12 PITC H ROOFS): CAPACITY: One worker per 8 feet of scaffolding plus 40 pounds of materials. GENERAL REQUIREMENTS: When installed,
the platform support arm must be set to match the pitch of the roof, allowing for the installation of a fully decked and level walk surface. MOUNTING THE ROOF BRACKET:
1) All brackets shall be attached to the roof with 20-penny nails. Use all slots on mounting plate. 2) Position bracket so that all nails penetrate both the roof’s surface and the rafter below. 3) Spacing between brackets shall not exceed 8 feet. INSTALLING PLATFORM: 1) wood platforms shall not be less than 2 inches nominal thickness and shall extend beyond the support arm not less than 6 inches and not more than 12 inches.
2) Always use clear, straight-grained wood free from knots or defects. 3) If extended length platforms are re­quired, use additional Roof Brackets every 8 feet. 4) Secure to bracket by nailing the platform to the bracket using the hole provided in the plat­form retainer. INSTRUCTIONS FOR USE: 1) No more than one person shall occupy any given 8 feet of a Roong Bracket Scaffold. 2) Always use OSHA compliant fall arrest sys­tem, guardrails, catch platforms or other safety equipment as required by Local, State or Federal OSHA Regulations. 3) Roof Brackets are intended for use by the experienced tradesman. 4) OSHA Regulations re­quire that employers provide training in the use and care of this product. CARE AND MAINTENANCE: 1) In­spect all Roong Brackets before each use to be sure that there is no damage or deformation, or de­terioration from rusting. Discard if necessary. 2) Do not throw or drop from a building or onto a truck. 3) Do not use if exposed to extreme heat or cold. Discard at once. 4) Do not use if wet or frozen.
HEAVY DUTY ROOFING BRACKETS
INSTRUCTIONS FOR INSTALLA­TION AND USE OF THE MODEL #2502 & #3505 6” X 90 DEGREE & #3502 8”x 90 DEGREE FIXED PITCH ROOFING BRACKET (For use only as a slide guard or a material support): CAPACITY: 250 pounds of materials. GENERAL REQUIREMENTS: On roofs with
a 4/12 to 6/12 roof pitch, when in­stalled as a slide guard, the scaffold brackets should provide a platform that is 90 degrees to the roof’s sur­face at a point along the eave of the roof. For roof slopes greater than 6/ 12 up to 8/12 additional 90-degree slide guards must be installed par­allel to the rst row no further than every eight feet of roof slope. Ad­ditional fall protection methods are required on slopes 8/12 or greater. When slope is greater than 4/12 and the ground to eave height is greater than 25 feet slide guards should not be used. MOUNTING THE ROOF BRACKET: 1) All brackets shall be attached to the roof with 20-penny nails. Use all slots on mounting plate.
2) Position bracket so that all nails penetrate both the roof’s surface and the rafter below. 3) Spacing between brackets shall not exceed 8 feet. INSTALLING PLATFORM:
1) wood pla tform s shall not be less than 2 inches nominal thick­ness and shall extend beyond the support arm not less than 6 inches and not more than 12 inches. 2) Always use clear, straight-grained wood free from knots or defects.
3) If extende d leng th pla tform s are required, use additional Roof Brackets every 8 feet. 4) Secure to bracket by nailing the platform to the bracket using the hole provided in the platform retainer. INSTRUC­TIONS FOR USE: 1) No more than one person shall occupy any given 8 feet of a Roong Bracket Scaffold.
2) Always use OSHA compliant fall arrest system, guard rails, catc h platforms or other safety equip­ment as required by Local, State or Federal OSHA Regulations. 3) Roof Brackets are intended for use by the experienced tradesman. 4) OS HA Regu lati ons req uir e that employers provide training in the use and care of this product. CARE
AND MAINTENANCE: 1) Inspect all Roong Brackets before each use to be sure that there is no damage or deformation, or deterioration from rusting. Discard if necessary. 2) Do not throw or drop from a building or onto a truck. 3) Do not use if exposed to extreme heat or cold. Discard at once. 4) Do not use if wet or frozen.
INSTRUCTIONS FOR INSTALLA­TION AND USE OF THE MODEL #2503 & #3506 6”x 60 DEGREE, #2504 & #3507 6”x 45 DEGREE, #2505 & #3508 4”x 90 DEGREE FIXED PITCH ROOFING BRACKET (For use only as a material sup­port): CAPACITY: 250 pounds of roofing materials.. MOUNTING
THE ROOF BRACKET: 1) All brack­ets shall be attached to the roof with 20-penny nails. Use all slots on mounting plate. 2) Position bracket so that all nails penetrate both the roof’s surface and the rafter below.
3) Spacing between brackets shall not exceed 8 feet. INSTALLING PLATFORM: 1) wood platforms shall not be less than 2 inches nominal thickness and shall extend beyond the support arm not less than 6 inches and not more than 12 inches.
2) Always use clear, straight-grained wood free from knots or defects. 3) If extended length platforms are re­quired, use additional Roof Brackets every 8 feet. 4) Secure to bracket by nailing the platform to the bracket us ing th e hol e pro vide d in th e platform retainer. INSTRUCTIONS FOR USE: 1) Material supports are not intended for use as a scaffold or work platform.. 2) Always use OSHA compliant fall arrest system, guardrails, catch platforms or other safety equipment as required by Lo­cal, State or Federal OSHA Regula­tions. 3) Roof Brackets are intended for use by the experienced trades­man. 4) OSHA Regulations require that employers provide training in the use and care of this product. CARE AND MAINTENANCE: 1) Inspect all Roong Brackets before each use to be sure that there is no damage or deformation, or deterioration from rusting. Discard if necessary. 2) Do not throw or drop from a building or onto a truck. 3) Do not use if exposed to extreme heat or cold. Discard at once. 4) Do not use if wet or frozen.
© Copyright 2003 • Qual-Craft® Industries • 1551 Central Street
PO Box 559 • Stoughton, MA 02072
Customer Support and Ordering Information
781-344-1000 • www.qualcraft.com