Quad II Eighty Owner's Manual

Owner’s Manual
Quad Electroacoustics Ltd, IAG House, Sovereign Court, Ermine Business Park,
Huntingdon PE29 6XU
England
www.quad-hifi.co.uk
Tel: 01480 447700 Fax: 01480 431767
SERVICE & INFORMATION
Authorised QUAD Service Centres in the U.K. and North America
www.quad-hifi.co.uk
If your QUAD equipment requires servicing (including valve replacement) you should return it to the dealer from whom the equipment was purchased.
If you are abroad and there is no suitable dealer in your area, please contact the distributor for the country in which it was purchased or QUAD Electroacoustics Ltd.
It is user's responsibility, whether the equipment is under warranty or otherwise, to ensure that equipment for service is returned carriage paid and in the original packaging. You should enclose a brief note with your name and address and the reason for returning the equipment.
For information on authorised service centres worldwide contact QUAD Electroacoustics Ltd. A worldwide distributor list is available on the QUAD website:
SPECIFICATIONS
Monobloc valve power amplifier
Input sensitivity (nom) 1V RMS for full output
Power output 80W RMS
Output Impedance 4 Ohms or 8 Ohms, selectable
THD at 80 Watts 0.2% - 1kHz
0.5% - 30Hz to 15Khz
1.0% - 20 to 20 Khz
Residual hum and noise Better than -94 dB
Frequency response 10 Hz to 30 KHz +0 -0.5 dB
3Hz to 50 Khz -3dB
Damping factor 16 at 1 kHz (referred to 8 Ohms)
Power consumption 240VA maximum
Valves 2 x 6SL7, 1 x 6SN7, 4 x KT88
Important Safety Precautions - Please Read Carefully!
U.K.
QUAD Electroacoustics Ltd. IAG House, Sovereign Court, Ermine Business Park, Huntingdon, Cambs PE29 6XU, England. Tel:+44 (0)1480 447700 Fax:+44 (0)1480 431767
QUADII eighty Manual 0405 Issue 1
Warning: To reduce the risk of fire or electrical shock,
IMPORTANT SAFETY INFORMATION
do not expose this product to rain or moisture. The
Read these instructions.
product must not be exposed to dripping and splashing
Keep these instructions.
and no object filled with liquids such as a vase of flowers
Heed all warnings.
should be placed on the product.
Follow all instructions.
No naked flame sources such as candles should be
Do not use this apparatus near water.
placed on the product.
Clean only with dry cloth.
Caution: Changes or modifications not expressly approved by the manufacturer could void the user's
Do not block any ventilation openings.
authority to operate this device.
Install in accordance with the manufacturer's
Warning: The mains power switch for this appliance is
instructions.
located on the side panel. To permit free access to this
Do not install near any heat sources such as radiators,
switch, the apparatus must be located in an open area
heat registers, stoves, or other apparatus (including
without any obstructions.
amplifiers) that produce heat.
IMPORTANT NOTICE TO UK USERS
Do not defeat the safety purpose of the polarized or
The appliance cord is terminated with a UK approved
grounding type plug. A polarized plug has two blades
mains plug fitted with a A fuse. If
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
Use only attachments/accessories specified by the manufacturer.
Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
10 the fuse needs to be replaced, an ASTA or BSI approved BS1362 fuse rated at 10A must be used. If you need to change the mains plug, remove the fuse and dispose of this plug safely immediately after cutting it from the cord.
Connecting a Mains Plug
The wires in the mains lead are coloured in accordance with the code: Blue: NEUTRAL Brown: LIVE: Green and Yellow: Earth. As these colours may not correspond to the coloured markings identifying the terminals in your plug, proceed as follows: The BLUE wire must be connected to the terminal marked with the letter N or coloured BLUE or BLACK. The BROWN wire must be connected to the terminal marked with the letter L or coloured BROWN or RED. The GREEN & YELLOW wire must be connected to the terminal marked with the letter E or coloured GREEN or GREEN & YELLOW or marked with the Earth Symbol
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER-REMOVEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED PERSONNEL
CAUTION!
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ADVERTISSEMENT: RISQUE DE CHOC ELECTRIQUE-
NE PAS OUVRIR
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
GREEN
&
YELLOW (EARTH)
BLUE
(NEUTRAL)
(LIVE)
BROWN
FUSE
(10 A)
USA
Taiga LLC 310 Tosca Drive Stoughton, MA 02072 Tel: 781-341-1234 Fax: 781-341-1228 Email: service@taigallc.com