● Installation must be in accordance with DMX512-A standard
● DMX Shield must be grounded to Earth Ground at a single point external to power supply
Risk of Fire / Electric Shock
Transformer should be installed by a Licensed electrician in accordance with the N.E.C. and all local codes in force.
QOM-eLED+DMX
Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.This power supply must be installed according to the National Electric Code and local codes and ordinances.This power supply is to be installed and serviced only by an licensed electricians.This power supply is to be installed so that it is not likely to be contacted by people.To avoid a hazard to children, account for all parts and destroy all packaging materials.
● 18 gauge Welded Steel Enclosure: 9.22"W x 15.4"H x 4.90"D
● Door: 9.27"W x 14.5"H
● Knockouts: 9
● Built-in support bracket incorporated to secure housing for surface mounting
FEATURES
● Limited output voltage and current, plus isolation for safe operation
● Fully potted driver(s) for moisture resistance
● Controllable with DMX decoder module
● Control 4 LED channels with DMX
● Surface mount only
● Suitable for dry, damp and wet locations
● Suitable for Use with Submersible Luminaire
● Primary Voltage - Universal (120-277V )
● Wide operating temperature range: -4 degF to 122 degF
● Fits up to (3):100W 24 VDC driver(s) and DMX decoder module(s)
● Driver has Class A sound rating
● DMX dimming down to 0%
● Class 2 Output
● 5 year warranty
Low Voltage Lighting Systems
: CSA Class 3425-15 and Class 3425-95 : CSA Standard C22.2 No. 250.0-08 - Luminaires : ANSI/ UL Standard 2108 - Low Voltage Lighting Systems : CSA Std C22.2 No 250.13-14 - Light Emitting Diode (LED) Equipment for Lighting Applications : ANSI/ UL Standard 8750 - Light Emitting Diode (LED) Equipment for Use in Lighting Products
LED Landscape Lighting Systems
: CSA Class 3402-15 and Class 3402-95 : CSA Standard C22.2 No. 250.7-07 -Extra-Low-Voltage Landscape Lighting Systems : ANSI/ UL Standard 1838 - Low Voltage Landscape Lighting Systems : CSA Std C22.2 No 250.13-14 - Light Emitting Diode (LED) Equipment for Lighting Applications : ANSI/ UL Standard 8750 - Light Emitting Diode (LED) Equipment for Use in Lighting Products
DMXin/LedSyncout
Use these connectors when the driver is used in a DMX network. For DMX in, connect the networkcable’s DMX+, DMX- and DMX shielding wire (the orange/white, orange and brown wire in a CAT5 cable) to the DMX in+, DMX in- and DMX in shield connector respectively. For LedSync out, connect the network cable’s DMX+, DMX- and DMX shielding wire to the LedSync out+, LedSync out- and LedSync shield connector respectively. DMX Shield must be grounded to Earth Ground at a single point external to power supply
M
-
+
LED DRIVER 2
LED DRIVER 1
(120V - 277V)
(120V - 277V)
BOTTOM TRAY
WBGR+24WBGR+24
WBGR+24DMX
9.22"
M
-
+
TOP TRAY
M
-
+
4Knockouts of 1.36"
1.36"
1.07"
Hole for 1"fitting
ORDERING GUIDE
SizeModelPrim. VSec. V
1 Size
100W200W300W
Max Load
(Watts)
1x100W
2x100W
3x100W
Secondary
Voltage(24VDC)
24VDC24VDC24VDC
Max Prim.
Amps@120V
0.95 A
1.90 A
2.85 A
2 Primary Voltage
UNV: 120-277 Vrms
3 Secondary Voltage
24VDC
4 DMX
DMX
5 Options
BK
Black Powder Coat SS316 Marine GradeFinish ( Standard )
● This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Black Wire = +24VRed Wire = Red LEDGreen Wire = Green LEDBlue Wire = Blue LEDWhite Wire = White LED
WBGR+24
WARNING: Risk of electrical shock. May result in serious injury or death. Disconnect power before servicing or installing.
CAUTION: The device may only be connected and installed by a qualified electrician. All applicable regulations, legislation and building codes must be observed.
Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs.
●DMX Shield must be grounded to Earth Ground at a single point external to power supply
● This power supply must be installed according to the National Electric Code and local codes and ordinances and in accordance with applicable installation
code by a person familiar with the construction and operation of the product and the hazards involved.
● Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
● This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.
● To avoid a hazard to children, account for all parts and destroy all packaging materials.
● DMX Shield wire must be grounded to Earth Ground at a single point external to Power Supply
QOM-eLED
Model
QOM-eLED-60QOM-eLED-120QOM-eLED-180
QOM-eLED-100QOM-eLED-200QOM-eLED-300
● Suitable For Indoor Or Outdoor Use
● Wall Mount OnlyINSTALLATION MURALE SEULEMENT
● Suitable For Mounting Within 1.2m (4ft) Of The GroundPEUT ÊTRE INSTALLÉ À MOINS DE 1.2 M (4 PI) DU SOL
● Suitable For Use With Submersible Luminaires Or Submersible Pumps
●
Suitable For WetLocations
CONVIENT AUX EMPLACEMENTS MOUILLÉ
● This Control Unit Has More Than One Power Supply PointDisconnect All Power Supplies Before Servicing COUPER L’ALIMENTATION AVEN L”ENTRETIEN
● For Supply Connections Use
● Keep Enclosure Cover Closed
● Read Installation Instructions Before Wiring
● Class 2
Wire Rated ForAt Least 60C.
Input Voltage
(V)
120120 120
120120120
QOM-eLED
Model
QOM-eLED-60QOM-eLED-120QOM-eLED-180
QOM-eLED-100QOM-eLED-200QOM-eLED-300
Input Voltage
(V)
120 / 277120 / 277120 / 277
120 / 277120 / 277120 / 277
INPUT VOLTAGEOUTPUT VOLTAGE
120V
Input Current
(A)
0.60
1.20
1.80
0.95
1.90
2.85
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
CE PRODUITDOITÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION PERTINENT, PAR UNE PERSONNE QUI CONNAÎTBIEN LE PRODUITETSON FONCTIONNEMENTAINSI QUE LES RISQUES INHÉRENTS.
WARNING:
RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED. CONSULT A QUALIFIED ELECTRICIAN
Frequency
50/6050/6050/60
50/6050/6050/60
Nominal Output
Voltage (VDC)
121212
242424
24V12V
Nominal Output
Wattage (W)
60120180
100200300
INPUT VOLTAGEOUTPUT VOLTAGE
120V - 277V
Input Current
(A)
0.60 / 0.29
1.20 / 0.58
1.80 / 0.87
0.95 / 0.40
1.90 / 0.80
2.85 / 1.20
Frequency
50/6050/6050/60
50/6050/6050/60
Nominal Output
Voltage (VDC)
121212
242424
24V12V
Nominal Output
Wattage (W)
60120180
100200300
CONTROL TYPE
0-10V
DMX
WD
AW
Q-TRAN, INC.
MILFORD, CT U.S.A.
(203) 367-8777
WWW.Q-TRAN.COM
LOW VOLTAGE LIGHTING SYSTEM &LED LANDSCAPE LIGHTING SYSTEM
CLASS:3425 - 15 3425 - 953402 - 15 3402 - 95
CONTROL TYPE
0-10V
DMX
WD
AW
● Suitable For Indoor Or Outdoor Use
● Wall Mount Only
● Suitable For Mounting Within 1.2m (4ft) Of The Ground
● Suitable For Use With Submersible Luminaires Or Submersible Pumps
●
Suitable For WetLocations
● This Control Unit Has More Than One Power Supply PointDisconnect All Power Supplies Before Servicing
● For Supply Connections Use
● Keep Enclosure Cover Closed
● Read Installation Instructions Before Wiring
● Class 2
Wire Rated ForAt Least 60C.
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
WARNING:
RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED. CONSULT A QUALIFIED ELECTRICIAN
Q-TRAN, INC.
MILFORD, CT U.S.A.
(203) 367-8777
WWW.Q-TRAN.COM
LOW VOLTAGE LIGHTING SYSTEM &LED LANDSCAPE LIGHTING SYSTEM