Q-tran QOM-eLED+DMX Installation Instructions Manual

QOM-eLED+DMX
INSTALLATION INSTRUCTIONS
Must be installed by licensed electrician.
Installation must be in accordance with DMX512-A standard
DMX Shield must be grounded to Earth Ground at a single point external to power supply
Risk of Fire / Electric Shock
Transformer should be installed by a Licensed electrician in accordance with the N.E.C. and all local codes in force.
QOM-eLED+DMX
Wear rubber shoes and work on a sturdy wooden or fiberglass ladder. This power supply must be installed according to the National Electric Code and local codes and ordinances. This power supply is to be installed and serviced only by an licensed electricians. This power supply is to be installed so that it is not likely to be contacted by people. To avoid a hazard to children, account for all parts and destroy all packaging materials.
COMPLI ANT
LANDSCAPE LIGHTING SYSTEMS
CLASS: 3425 - 15 3425 - 95
3402 - 15 3402 - 95
20190826-V01© 2019, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com
QOM-eLED+DMX
HOUSING
18 gauge Welded Steel Enclosure: 9.22"W x 15.4"H x 4.90"D
Door: 9.27"W x 14.5"H
Knockouts: 9
Built-in support bracket incorporated to secure housing for surface mounting
FEATURES
Limited output voltage and current, plus isolation for safe operation
Fully potted driver(s) for moisture resistance
Controllable with DMX decoder module
Control 4 LED channels with DMX
Surface mount only
Suitable for dry, damp and wet locations
Suitable for Use with Submersible Luminaire
Primary Voltage - Universal (120-277V )
Wide operating temperature range: -4 degF to 122 degF
Fits up to (3):100W 24 VDC driver(s) and DMX decoder module(s)
Driver has Class A sound rating
DMX dimming down to 0%
Class 2 Output
5 year warranty
Low Voltage Lighting Systems
: CSA Class 3425-15 and Class 3425-95 : CSA Standard C22.2 No. 250.0-08 - Luminaires : ANSI/ UL Standard 2108 - Low Voltage Lighting Systems : CSA Std C22.2 No 250.13-14 - Light Emitting Diode (LED) Equipment for Lighting Applications : ANSI/ UL Standard 8750 - Light Emitting Diode (LED) Equipment for Use in Lighting Products
LED Landscape Lighting Systems
: CSA Class 3402-15 and Class 3402-95 : CSA Standard C22.2 No. 250.7-07 - Extra-Low-Voltage Landscape Lighting Systems : ANSI/ UL Standard 1838 - Low Voltage Landscape Lighting Systems : CSA Std C22.2 No 250.13-14 - Light Emitting Diode (LED) Equipment for Lighting Applications : ANSI/ UL Standard 8750 - Light Emitting Diode (LED) Equipment for Use in Lighting Products
DMX in/LedSync out
Use these connectors when the driver is used in a DMX network. For DMX in, connect the network cable’s DMX+, DMX- and DMX shielding wire (the orange/white, orange and brown wire in a CAT5 cable) to the DMX in+, DMX in- and DMX in shield connector respectively. For LedSync out, connect the network cable’s DMX+, DMX- and DMX shielding wire to the LedSync out+, LedSync out- and LedSync shield connector respectively. DMX Shield must be grounded to Earth Ground at a single point external to power supply
M
-
+
LED DRIVER 2
LED DRIVER 1
(120V - 277V)
(120V - 277V)
BOTTOM TRAY
W B G R+24 W B G R+24
W B G R+24 DMX
9.22"
M
-
+
TOP TRAY
M
-
+
4 Knockouts of 1.36"
1.36"
1.07"
Hole for 1" fitting
ORDERING GUIDE
SizeModel Prim. V Sec. V
1 Size
100W 200W 300W
Max Load
(Watts)
1x100W
2x100W
3x100W
Secondary
Voltage(24VDC)
24VDC 24VDC 24VDC
Max Prim.
Amps @ 120V
0.95 A
1.90 A
2.85 A
2 Primary Voltage
UNV: 120-277 Vrms
3 Secondary Voltage
24VDC
4 DMX
DMX
5 Options
BK
Black Powder Coat SS 316 Marine Grade Finish ( Standard )
Stainless Steel
Ordering Example
QOM-eLED-100-UNV/24+DMX
LED DRIVER 3
(120V - 277V)
NEU
GND
HOT
PRIMARYSECONDARY
BOTTOM
5 Knockouts of 1.07"
Hole for 3/4" fitting
Opts
DMX
+24 DMXQOM-eLED UNV
Max Prim.
@ 277V
Max Prim.
Amps @ 277V
0.40 A
0.80 A
1.20 A
14.5"
4.90"
15.4"
© 2019, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com
1
QOM - eLED+DMX
15.4"
4.90"
4.90"
Housing & Mounting Options
QOM HOUSING
14.5"
9.22"
ISOMETRIC VIEW
VDC
24
*
Distances are based on a 5% Voltage drop max.
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
1.07" KNOCKOUT 5X (FOR 3/4" FITTINGS)
1.36" KNOCKOUT 4X (FOR 1" FITTINGS)
VOLTAGE D ROP CHART
10 AWG 12 AWG 14 AWG 16 AWG 18 AW G 20 AWG 22 AW G 24 AW G 26 AW G
2
) (3.3mm2) (3.0mm2) (1.3mm2) (0.78mm2) (0.50mm2) (0.33mm2) (0.20mm2) (0.13mm2)
(5.6mm
(W)
17
25
40 80
100
309 130
84
356 567
194
355564897
141224
122
77 48 30 30
51 32
82
53
20 13 8
2133
13 8 5 3
355688
22
355588140223
14
22
7
12
3
5
BOTTOM VIEW
MOUNTING OPTIONS
Surface Wall Mount
Pole Mount
1.82"
3.38"
3.14"
0.25"
2.00"
1/4”x2” wood screw or LAG bolt recommened
NOTE: To order additional lengths of wire for connection in the secondary Please
call Factory for availability.
: QOM must be installed as shown.
© 2019, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com
2
QOM - eLED+DMX
+
iQ-LED
LED DRIVER
To DMX Controller
LINEARdrive 180D
12-28V / 6A Direct voltage controlled LED driver
LINEARdrive 180D
12-28V / 6A Direct voltage controlled LED driver
-
+
iQ-LED
M
-
+
DMX +
DMX -
DMX Shield
DMX
GND
HOT
NEU
LED DRIVER
(120 - 277V)
NEU
GND
HOT
Connecting & Configuration Instruction
Connecting and configuring the LINEARdrive 100D/180D
W B G R +24
LED DRIVER 2 (120 - 277V)
M
-
+
DMX in +
LedSync thru +
LedSync shield
DMX in shield
DMX in -
LedSync thru -
Ext in
-
Ext in +
Primary Wiring
(120 - 277V)
DMX in shield LedSync shield
DMX in - LedSync thyu -
DMX in + LedSync thyu +
GND
GND
NEU
HOT
NEU
HOT
LedSync shield
LedSync thru -
LedSync thru +
DMX in shield
Ext in Ext in +
DMX in -
DMX in +
-
Blue Wire = Blue LED
Red Wire = Red LED
Green Wire = Green LED
White Wire = White LED
Black Wire = +24V
DMX Shield
DMX -
DMX +
SECONDARY
PRIMARY
iQ-LED
A C
B
NEU
W B G R +24
DMX
HOT
GND
GND
HOT
NEU
Commonly Asked Questions
1) How can I verify my installation?
Apply AC input, verify display turns on : This confirms AC input wiring
Run “Visual Test Run” : This verifies wiring of LEDs. Make sure LEDs turning on go in
same order as the Test Run
2) I don’t have a controller yet, how can I keep my lights on?
Change the Mode to “COLR” : This allows to manually set a specific color to be on
Adjust the Hue or WHIT to achieve the desired color : This sets that specific color
3) My LEDs aren’t coming out the right color. They look like white has been added in
Verify the Network Resolution “NETW RES” : Default is 8 BT
Check your DMX Programming. Stick controllers come with RGB programs by default. This will cause RGBW LEDs to show Pink vs. Red
Secondary Wiring
TC
LED supply +
Group
1
Group
2
3
Group
4
Group
© 2019, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com
Control Wiring
DMX connections
LedSync shield
iQ-LED
Black Wire = +24V Red Wire = Red LED Green Wire = Green LED Blue Wire = Blue LED White Wire = White LED
W B G R +24
WARNING: Risk of electrical shock. May result in serious injury or death. Disconnect power before servicing or installing.
CAUTION: The device may only be connected and installed by a qualified electrician. All applicable regulations, legislation and building codes must be observed.
Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs.
DMX Shield must be grounded to Earth Ground at a single point external to power supply
LedSync thru -
LedSync thru +
DMX in shield
Ext in
Ext in +
DMX in -
- DMX in +
DMX in shield
DMX in -
DMX in +
DMX
3
QOM - eLED+DMX
Configuration Instruction
Manual configuration
1. Select mode of operation: 2. Set LED groups:
(5 sec)
M
M
+
+
Set mode
MODE
SET
M
display off
-
COLR
SHOW
DMX
+
/
3. Standalone Standalone Networked operation or operation or operation
- Colour*- - Show - - DMX -
M
HUE
HUE
M
White
WHIT
M
Intensity
INT
M
display off
-
/
0...1535
-
/
0...255
-
/
0...255
+
+
+
M
Show
SHOW
M
Speed
SPD
M
Intensity
INT
M
display off
-
00...20
-
-99...99
-
0...255
M
+
/
DMX address
ADDR
DMX
M
+
/
Network resolution
RES
NETW
M
+
/
Interpolation
INTERPOL
M
display off
-
1...512
-
8 BT
16 BT
-
OFF VID COLR WHIT GLOW
LED groups
LED
M
External input
EXT INP
M
Dimming curve
DIM CURV
M
display off
+
/
+
/
+
/
1-1L 2-2L 3-3L 4-4L 2-4L 1-4L
OFF POTM 10V SWIT
LOG LIN
-
-
-
/
RGB RGBW RGBA RRGB RGGB CCWW CWWW
/
/
+
+
+
* The colour menu depends on the LED group settings you have selected in step 2.
Other features
Visual test run
M
+ +
Test
TEST
R 1 sec G 1 sec B 1 sec
W 1 sec
RGBW 1 sec
R 1 sec G 1 sec B 1 sec
W 1 sec
RGBW 1 sec
display off
-
+
Locking the configuration:
M
Lock driver
LOCK
display off
(5 sec)
+
+
-
+
/
NO
M
SOFT HARD
© 2019, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com
Reset to factory defaults
M
-
+ +
Reset
RE - SET
PRES MENU
Press menu
M
display off
+
(5 sec)
4
QOM-eLED+DMX
M
-
+
iQ-LED
: for exterior
QOM - eLED+DMX
Wiring Installation
LED DRIVER 2 (120 - 277V)
M
-
+
B
LED DRIVER 2 (120 - 277V)
M
-
+
B
B
NEU
GND
HOT
DMX Shield
W B G R +24V
LED DRIVER 2 (120 - 277V)
M
-
+
A C
W B G R +24 W B G R+24
DMX -
DMX +
Blue Wire = Blue LED Red Wire = Red LED Green Wire = Green LED White Wire = White LED Black Wire = +24V
W B G R +24
DMXW B G R +24
SECONDARY
PRIMARY
GND
iQ-LED iQ-LED iQ-LED
© 2019, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com
HOT
NEU
5
QOM - eLED+DMX
CSA Label
CSA REQUIREMENTS
Suitable for Indoor and Outdoor use
This power supply must be installed according to the National Electric Code and local codes and ordinances and in accordance with applicable installation
code by a person familiar with the construction and operation of the product and the hazards involved.
Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.
To avoid a hazard to children, account for all parts and destroy all packaging materials.
DMX Shield wire must be grounded to Earth Ground at a single point external to Power Supply
QOM-eLED
Model
QOM-eLED-60 QOM-eLED-120 QOM-eLED-180
QOM-eLED-100 QOM-eLED-200 QOM-eLED-300
Suitable For Indoor Or Outdoor Use
Wall Mount Only INSTALLATION MURALE SEULEMENT
Suitable For Mounting Within 1.2m (4ft) Of The Ground PEUT ÊTRE INSTALLÉ À MOINS DE 1.2 M (4 PI) DU SOL
Suitable For Use With Submersible Luminaires Or Submersible Pumps
Suitable For Wet Locations
CONVIENT AUX EMPLACEMENTS MOUILLÉ
This Control Unit Has More Than One Power Supply Point Disconnect All Power Supplies Before Servicing COUPER L’ALIMENTATION AVEN L”ENTRETIEN
For Supply Connections Use
Keep Enclosure Cover Closed
Read Installation Instructions Before Wiring
Class 2
Wire Rated For At Least 60C.
Input Voltage
(V)
120 120 120
120 120 120
QOM-eLED
Model
QOM-eLED-60 QOM-eLED-120 QOM-eLED-180
QOM-eLED-100 QOM-eLED-200 QOM-eLED-300
Input Voltage
(V)
120 / 277 120 / 277 120 / 277
120 / 277 120 / 277 120 / 277
INPUT VOLTAGE OUTPUT VOLTAGE
120V
Input Current
(A)
0.60
1.20
1.80
0.95
1.90
2.85
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS.
WARNING:
RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED. CONSULT A QUALIFIED ELECTRICIAN
Frequency
50/60 50/60 50/60
50/60 50/60 50/60
Nominal Output
Voltage (VDC)
12 12 12
24 24 24
24V12V
Nominal Output
Wattage (W)
60 120 180
100 200 300
INPUT VOLTAGE OUTPUT VOLTAGE
120V - 277V
Input Current
(A)
0.60 / 0.29
1.20 / 0.58
1.80 / 0.87
0.95 / 0.40
1.90 / 0.80
2.85 / 1.20
Frequency
50/60 50/60 50/60
50/60 50/60 50/60
Nominal Output
Voltage (VDC)
12 12 12
24 24 24
24V12V
Nominal Output
Wattage (W)
60 120 180
100 200 300
CONTROL TYPE
0-10V
DMX
WD
AW
Q-TRAN, INC.
MILFORD, CT U.S.A.
(203) 367-8777
WWW.Q-TRAN.COM
LOW VOLTAGE LIGHTING SYSTEM & LED LANDSCAPE LIGHTING SYSTEM
CLASS: 3425 - 15 3425 - 95 3402 - 15 3402 - 95
CONTROL TYPE
0-10V
DMX
WD
AW
Suitable For Indoor Or Outdoor Use
Wall Mount Only
Suitable For Mounting Within 1.2m (4ft) Of The Ground
Suitable For Use With Submersible Luminaires Or Submersible Pumps
Suitable For Wet Locations
This Control Unit Has More Than One Power Supply Point Disconnect All Power Supplies Before Servicing
For Supply Connections Use
Keep Enclosure Cover Closed
Read Installation Instructions Before Wiring
Class 2
Wire Rated For At Least 60C.
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
WARNING:
RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED. CONSULT A QUALIFIED ELECTRICIAN
Q-TRAN, INC.
MILFORD, CT U.S.A.
(203) 367-8777
WWW.Q-TRAN.COM
LOW VOLTAGE LIGHTING SYSTEM & LED LANDSCAPE LIGHTING SYSTEM
CLASS: 3425 - 15 3425 - 95 3402 - 15 3402 - 95
© 2019, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com
6
Loading...