Q-SYS SPA2-60, SPA4-60, SPA2-200, SPA4-100 User guide

Page 1
System Power Amplifier (SPA)
Installation Guide
SPA2-60 Amplifier SPA4-60 Amplifier SPA2-200 Amplifier SPA4-100 Amplifier
EXPLANATION OF SYMBOLS
The term “WARNING!” indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily injury or death.
The term “CAUTION!” indicates instructions regarding possible damage to physical equipment. If these instructions are not followed, it may result in damage to the equipment that may not be covered under the warranty.
The term "NOTE" is used to indicate additional useful information.
The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un-insulated "dangerous" voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans.
The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important safety, and operating and maintenance instructions in this manual.
What's in the Box
SPA2-60 SPA2-200 SPA4-60 SPA4-100
Rack-Ear Spacer QSC P/N CH-001386-00
Rack-Ear Cover Label QSC P/N LB-001138-00
SPA 4-channel (1x)
Plug 3.5 mm, 10 pos, grn QSC P/N CO-000681-00
(1x)
AC Power Cord, US
(2x)
Phillips Pan Head M4 x 7 mm
(1x)
Euro Plug 3.5 mm, 4 pos, grn QSC P/N CO-000649-00
Plug 3.5 mm, 10 pos, grn QSC P/N CO-000683-00
(1x)
(6x)
SPA 2-channel (1x) SPA 4-channel (2x)
SPA 4-channel (1x)
Rack Ear QSC P/N CH-001344-00
Phillips Flathead M3 x 6 mm
Euro Plug 3.5 mm, 5 pos, grn QSC P/N CO-000644-00
Warranty TD-000453
(2x)
(6x)
SPA 2-channel (1x)
(1x)
Joining Plate QSC P/N CH-001345-00
Foam Spacer QSC P/N PL-001023-00
Euro Plug 3.5 mm, 4 pos, blk QSC P/N CO-000645-00
Safety Information TD-000337
(2x)
(4x)
SPA 2-channel (1x)
(1x)
TD-000500-00-F
*TD-000500-00*
Page 2
Installation
2
1
Ventilation
• Recommend 1RU (1.75 in / 44.45 mm) space above the amplifier.
• Minimum open space of 6 inches measured from back of amplifier.
NOTE:
circuitry which allows them to reduce output power in order to maintain safe operating temperatures. Insufficient ventilation may result in the amplifier reducing output power during normal operation (indicated by Limiter/Protect LEDs illuminating red). To reduce the possibility of thermal limiting, and allow proper heat dissipation, we recommend that you keep the space directly above and to the rear of these amplifiers free of obstacles.
QSC System Power Amplifiers contain advanced protection
— Figure 1 —
Select the Amplifier Installation Configuration
Choose one of the following configuration options:
A. One Amplifier 19-inch Rack (Left or Right Mount) on page 3 D. Under Table or on Wall on page 4
B. Two Amplifiers 19-inch Rack (Front or Rear Facing Out) on page 3 E. Free-Standing on Desk/Table on page 5
C. One Amplifier Half Rack (Front or Rear Facing Out) on page 4 F. Plenum Installation on page 5
2
Page 3
A. One Amplifier 19-inch Rack (Left or Right Mount)
6
Figure 2
1.
(1)
2
2.
(2)
3
3.
(5)
4.
(1)
B. Two Amplifiers 19-inch Rack
(Front or Rear Facing Out)
Figure 3
1.
(2)
Top Side
Front Panel
1
4
— Figure 2 —
5
3
Top Side
Front Panel
2
4
1
Bottom Side
Amp 2
4
3
Front Panel
2.
3.
4.
5.
6.
(2)
(2)
(6)
(1)
(6)
Bottom Side
Amp 1
2
1
Front Panel
4
3
1
6
5
Bottom Side
Amp 2
Rear Panel
4
3
Bottom Side
Amp 1
2
1
Rear Panel
4
3
1
— Figure 3 —
3
Page 4
C. One Amplifier Half Rack (
1
2
3
3
2
1
2
3
Figure 4
1. (1)
Front or Rear Facing Out
)
Top Side
2. (2)
3. (6)
D. Under Table or on Wall
Figure 5.
1.
(1)
Top Side
— Figure 4 —
Front Panel
Rear Panel
5
2.
(2)
3.
(6)
4.
(4)
Not supplied – use appropriate screws for
mounting surface.
5. Mounting Surface
3
2
1
4
Mounting
Surface
Bottom Side
— Figure 5 —
Front Panel
4
Page 5
E. Free-Standing on Desk/Table
1 2 3 4
1
2
3
4
Figure 6
1.
(1)
2.
(4)
2
Bottom Side
Front Panel
1
F. Plenum Installation
Configure amplifier per option D Under Table or on Wall.
Figure 7
1.
(1)
2.
(1)
Plenum Kit - Suitable for Air Handling Spaces only when used with optional Plenum Kit (FG-000995-00) sold separately.
Rack-Mounting Options
All Configurations
Figure 8
Using the examples shown, you can mount any of the amplifier configurations. The example at the lower right of
Figure 8 can be flipped to accommodate a single amplifier
on the left side.
1. Equipment Rack (not supplied)
— Figure 6 —
2
— Figure 7 —
Top Side
Front Panel
1
2.
(2)
Optional – to bring flush with Q-Sys Core 110
3.
(2)
4.
(4)
Rack-Mounting Screws and Washers (not supplied)
— Figure 8 —
5
Page 6
Front Panel
Limiter / Protect
Red – Protect / Mute Orange – Limiter on
Input Signal
Blue – Present
Power
Blue – On Orange – Standby
Limiter / Protect
Red – Protect / Mute Orange – Limiter on
Input Signal
Blue – Present
— Figure 9 —
Rear Panel
1 2 3 4 5 4 6 7 8
1 2 3 4 5 4 6 7
4 4
Power
Blue – On Orange – Standby
9 10 11 12 13 14
— Figure 10 —
1. Output Channels 1 & 2
2. Remote Control Channels 1 & 2
3. Input Channels 1 & 2
4. Channel 1 thru Channel 4 Status LEDs a. Green – Normal Signal Level
5. Channel 1 Attenuator Control
6. Channel 2 Attenuator Control
7. Mode Configuration Switches Channel 1& 2
8. AC Power Connection
9. Output Channels 3 & 4
10. Remote Control Channel 3 & 4
11. Input Channels 3 & 4
12. Mode Configuration Switches Channel 3 & 4
13. Channel 3 Attenuator Control
14. Channel 4 Attenuator Control
b. Amber – Input or Output Overload/
Clipping or Thermal Limiting c. Red – Limit or Protect Mode d. Red – Thermal Limit or Protect Mode e. Red – Mute
1 No signal for 10 minutes, amplifier outputs are muted (LEDs are red). No signal for 25 minutes, amplifier is put in Standby Mode (Rear LEDs are off).
1
6
8
Page 7
Connections
5mm
1:1
Wire
IMPORTANT:
Output Connectors
IMPORTANT:
Figure 12 – Figure 13
SPA 2-channel
(1)
SPA 4-channel
(2)
Class 2 Wiring
Class 2 Wiring
— Figure 12 —
— Figure 11 —
SPA 2-channel
Strip Length = 5mm
DO NOT TIN!
SPA 4-channel
— Figure 13 —
Input Connectors
SPA 2-channel Connector
Figure 14 – Figure 15
(1)
SPA 4-channel Connector
Figure 16 – Figure 17
(1)
— Figure 14 —
— Figure 16 —
— Figure 15 —
— Figure 17 —
7
Page 8
Balanced and Unbalanced Inputs
& &
&
Figure 18
Stereo Mode
Figure 19 – Figure 21
Balanced
Unbalanced
— Figure 18 —
Inputs
Unbalanced Inputs:
jumper between (-) negative and ground.
Outputs
— Figure 19 —
CAUTION!: Do not connect any output to ground.
— Figure 20 —
— Figure 21 —
8
Page 9
4 or 8-ohm Bridged Mode
& &
&
& &
&
X
X
Figure 22 – Figure 25
8+ Bridged Load
Inputs
— Figure 23 —
4 - 8 Bridged Load
— Figure 22 —
CAUTION!: Do not connect any output to ground.
IMPORTANT:
Mode, use both signal inputs of a channel pair (for example parallel CH1&2 inputs and parallel CH3&4 inputs), and set the attenuation for each channel pair to the same level.
When using 4 or 8-ohm Bridged
70V / 100V Bridge Mode
NOTE:
in bridged 70 V and 100 V modes
80 Hz (high-pass filter) is auto-engaged
Outputs
— Figure 24 —
— Figure 25 —
Bridged Outputs
Figure 26 – Figure 29
— Figure 26 —
Bridged
Inputs
— Figure 27 —
— Figure 28 —
Minimum Load Impedance:
• 70V Bridged = 16
• 100V Bridged = 26
— Figure 29 —
9
Page 10
Remote
Figure 30 – Figure 32
SPA 2-channel
(1)
3.5mm, 5-pin
V = +10Vdc reference output C = 0-10Vdc control input
C @ 10V = Max Volume C @ 0V = Mute
10 k
Standby Switch in Run Mode
SPA 4-channel
(1)
3.5mm, 10-pin
When the potentiometer is at the minimum position, the amplifier goes into Mute mode. On the SPA 4-channel amplifier, the remote level controls for channel 1 & 2 are independent from channels 3 & 4 remote level control.
On the SPA 4-channel model, closing the "Standby Switch" between the first two pins of either Ch1-Ch2 or Ch3-Ch4 causes all four channels to go into Standby.
Standby Switch in Standby Mode
— Figure 30 —
SPA 2-channel
— Figure 32 —
— Figure 31 —
SPA 4-channel
10
Page 11
Mailing Address:
QSC, LLC
1675 MacArthur Boulevard
Costa Mesa, CA 92626-1468 USA
Telephone Numbers:
Main Number: (714) 754-6175
Sales & Marketing: (714) 957-7100 or toll free (USA only) (800) 854-4079
Customer Service: (714) 957-7150 or toll free (USA only) (800) 772-2834
Facsimile Numbers:
Sales & Marketing FAX: (714) 754-6174
Customer Service FAX: (714) 754-6173
World Wide Web:
www.qsc.com
E-mail:
info@qsc.com
service@qsc.com
© 2015 - 2022 QSC, LLC. All rights reserved. QSC and the QSC logo are registered trademarks of QSC, LLC in the U.S. Patent and Trademark office and other countries. All other
trademarks are the property of their respective owners.
http://patents.qsc.com.
Loading...