Ph: 800/854-4079 or 714/957-7100 • Fax: 714/754-6174
trademarks are the property of their respective owners. Patents may apply or be pending.
www.qsc.com
614-0006363
Page 2
Attero Tech by QSC Axiom Product Family
User Manual
IMPORTANT SAFETY INSTRUCTIONS
The symbols below are internationally accepted symbols that warn of potential hazards with electrical products.
This symbol, wherever it appears, alerts you to the presence of un-insulated dangerous voltage inside the enclosure -- voltage
that may be sufficient to constitute a risk of shock.
This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature.
Please read the manual.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce
heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the
other. A grounding type plug has two blades and third grounding prong. The wider blade or the third prong is provided for your
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they
exit from the apparatus.
11. Only use attachments/accessories specified by Attero Tech
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as
power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been dropped.
15. When permanently connected, on all-pole mains switch with a contact separation of at least 3mm in each pole shall be incorporated
in the electrical installation of the building.
16. If rack mounting, provide adequate ventilation. Equipment may be located above or below this apparatus but some equipment (like
large power amplifiers) may cause an unacceptable amount of hum or may generate too much heat and degrade the performance
of this apparatus.
QSC, LLC 2020 614-00063
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
Page 3
Attero Tech by QSC Axiom Product Family
A
These limits are
designed to provide reasonable protection against harmful interference when the
This equipment generates, uses,
radiate radio frequency energy and, if not installed and used in accordance with
.
Operation of this equipment in a residential area is likely to cause harmful interference,
User Manual
WARRANTY INFORMATION
For a copy of the QSC Limited Warranty, visit the QSC website at www.qsc.com
Note: This equipment has been tested and found to comply with the limits for a Class
digital device, pursuant to Part 15 of the FCC Rules and EN55022.
equipment is operated in a commercial environment.
and can
the instruction manual, may cause harmful interference to radio communications
in which case the user will be required to correct the interference at their own expense.
QSC, LLC 2020 614-00063
Page 4
Attero Tech by QSC Axiom Product Family
User Manual
Contents
1 – Axiom Bus Overview ............................................................................................................................................................................................................... 1
– ML1 – What’s in the Box ................................................................................................................................................... 1
– ML1 – Signal Metering LED Indications ...................................................................................................................... 1
– USB1 – What’s in the Box .................................................................................................................................................. 2
– BT1 – What’s in the Box .................................................................................................................................................... 2
– AXP2O – What’s in the Box ............................................................................................................................................... 5
– 3rd Party Control ............................................................................................................................................................... 7
– AXPio – What’s in the Box ................................................................................................................................................. 8
– 3rd Party Control ............................................................................................................................................................. 11
Device Specifications..................................................................................................................................................................................................................... iii
ML1 Specs ............................................................................................................................................................................... iii
USB1 Specs .............................................................................................................................................................................. iii
BT1 Specs ................................................................................................................................................................................ iv
AXP2O Specs ........................................................................................................................................................................... iv
AXPio Specs .............................................................................................................................................................................. v
QSC, LLC 2020 614-00063
Page 6
8P8C
TIA 568A
TIA 568B
Axiom Port
1
3: Green/White
2: Orange/White
Analog Audio 1+
2
3: Green
2: Orange
Analog Audio 1-
3
2: Orange/White
3: Green/White
Analog Audio 2+
4
1: Blue
1: Blue
RS-232 TXD)
5
1: Blue/White
1: Blue/White
RS-232 RXD
6
2: Orange
3: Green
Analog Audio 2-
7
4: Brown/White
4: Brown/White
+24 VDC
8
4: Brown
4: Brown
GND
1 – Axiom Bus Overview
The Attero Tech Axiom bus is a proprietary analog extension
solution that leverages unshielded twisted pair cabling (CAT 5/6)
to transmit two balanced audio channels, RS-232 control and 24V
DC power for audio signal extension applications.
The Axiom bus is designed to support distances of up to 100m
(total run length). The Axiom bus also supports daisy chain
connectivity of up to two Axiom devices to provide flexible
modularity for various audio device connectivity in installed AV
systems.
Application Diagram
Attero Tech by QSC Axiom Product Family
User Manual
Pin
Pair: Color
Table 1 - Axiom Bus Details
Pair: Color
Function
QSC, LLC 2020 614-00063
Figure 1 - Axiom Bus Application
Page 7
2– ML1 – Overview
Attero Tech by QSC Axiom Product Family
User Manual
Figure 2 – ML1 Front Panel
The Axiom ML1 provides an installation friendly simple to operate
analog audio extension solution for analog mic and line level
sources in cost-sensitive applications such as small and medium
sized retail, restaurant, education, and hospitality venues.
– ML1 – What’s in the Box
The ML1 comes supplied with the following:
o Axiom ML1device
o Includes interchangeable white and black Decora-style
o (1) White US Single Gang Decora® cover plate w/screws
o (1) Black US Single Gang Decora® cover plate w/screws
o (2) Wall plate mounting screws
inserts
Figure 3 - Product Overview
ID Description
1 Gain Adjust Knobs
2 Signal Presence Indicators
3 3.5mm Input
4 XLR/TRS Input (1/4” TRS Padded for +20dBu support)
5 Axiom Port A Configuration Switches
6 Axiom Ports (A & B)
QSC, LLC 2020 614-00063
Page 8
Figure 4 - Dimensional Drawing
– ML1 – Device Installation
ML1 – Mounting
A typical installation will involve mounting the wall plate
into a pre mounted wall box or mounting bracket. Before
installation, make sure the wall box where the ML1 is to
be installed is pre-wired with a suitable cable back to an
Axiom-enabled expander/injector.
Prior to ML1 installation, ensure the power sourcing
device (Axiom expander/injector) is powered off.
Attach and unshielded CAT-5/6 cable from the Axiomenabled device to the Axiom port A of the ML1.
With the cable attached, carefully place the ML1 into the
wall box taking care to not trap the cabling. Once in
place, secure it with the screws provided. Once the unit
is secured in the wall box, fit the Decora plate and secure
it with the screws provided.
Now you may apply power to the Axiom-enabled
expander/injector, the unit will power up and the signal
presence LEDs should blink once quickly.
The ML1 comes in a single gang US Decora style form
factor and may be mounted in most US single old and
new work back boxes and mud-rings. Given the single
gang size, the ML1 may be mounted in larger gang
boxes with other single gang form factor products to
provide flexible AV system modularity where needed.
*Note: CAD drawings can be downloaded from the QSC
website. Please contact Attero Tech for any further
product related information that is not accessible on the
website.
Attero Tech by QSC Axiom Product Family
User Manual
QSC, LLC 2020 614-00063
Page 9
Figure 6 - Signal Flow
– ML1 – Signal Metering LED Indications
The ML1 is equipped with two LED indicators below the rotary
encoders for each the ¼”/XLR Mic input and the 3.5mm line input.
The following chart indicates the available LED status
information:
Attero Tech by QSC Axiom Product Family
User Manual
Overview
The ML1 may be configured for single use, or daisy-chained with
one other Axiom device.
The default configuration is for single device use with Port B
disabled and XLR enabled.
Figure 5 – LED Signal Metering
LED State Status
Off No signal present
Green -60 dBFS to < -20 dBFS
Yellow/Amber -20 dBFS to < -3 dBFS
Red -3 dBFS to 0 dBFS
Note: The full scale output of the Axiom bus is optimized for
+20dBu levels, so 0dBFS in terms of metering refers to +20 dBu
– ML1 – Controls
The ML1 controls the desired input gain simply using the
coinciding input knob (see Figure 4). Turning the knob clockwise
raises the level, while counter-clockwise lowers.
– ML1 – Device Config & Workflow
Figure 7 - Switch Label/Config Options
The CH1 Select switches allows the integrator to route either the
XLR or a sum of the XLR and 3.5mm inputs to the CH1 output of
Axiom Port A.
The CH2 Select allows the integrator to route either the 3.5mm
input or the Axiom Port CH1 (daisy chained Axiom device) to the
CH2 output of Axiom Port A.
QSC, LLC 2020 614-00063
Page 10
3– USB1 – Overview
Attero Tech by QSC Axiom Product Family
User Manual
Figure 8 – USB1 Front Panel
The Axiom USB1 provides bidirectional USB audio connectivity for
education, corporate or hospitality applications. Connect a PC or
music content server to interface your device’s USB audio content
with the room’s audio system. The USB1 also offers BYOD (bringyour-own-device) support, allowing users to connect their laptops
to integrate the room’s audio into their web conferencing
application (Microsoft Teams, Zoom, etc).
– USB1 – What’s in the Box
The USB1 comes supplied with the following:
o Axiom USB1device
o Includes interchangeable white and black Decora-style
inserts
o (1) White US Single Gang Decora® cover plate w/screws
o (1) Black US Single Gang Decora® cover plate w/screws
o (2) Wall plate mounting screws
Figure 9 - Product Overview
ID Description
1 Status LED
2 USB Type B Port
3 Axiom Port Configuration Switch
4 Axiom Ports (A & B)
5 Mini-USB Configuration Port
QSC, LLC 2020 614-00063
Page 11
Figure 10 - Dimensional Drawing
– USB1 – Device Installation
USB1 – Mounting
A typical installation will involve mounting the wall plate into a
pre mounted wall box or mounting bracket. Before installation,
make sure the wall box where the USB1 is to be installed is prewired with a suitable cable back to an Axiom-enabled
expander/injector.
Prior to USB1 installation, ensure the power sourcing device
(Axiom expander/injector) is powered off.
Attach and unshielded CAT-5/6 cable from the Axiom-enabled
device to the Axiom port A of the USB1.
With the cable attached, carefully place the USB1 into the wall
box taking care to not trap the cabling. Once in place, secure
it with the screws provided. Once the unit is secured in the wall
box, fit the Decora plate and secure it with the screws
provided.
Now you may apply power to the Axiom-enabled
expander/injector, the unit will power up and the signal
presence LEDs should blink once quickly.
The USB1 comes in a single gang US Decora style form factor
and may be mounted in most US single old and new work back
boxes and mud-rings. Given the single gang size, the USB1
may be mounted in larger gang boxes with other single gang
form factor products to provide flexible AV system modularity
where needed.
*Note: CAD drawings can be downloaded from the QSC
website. Please contact QSC for any further product related
information that is not accessible on the website.
Attero Tech by QSC Axiom Product Family
User Manual
QSC, LLC 2020 614-00063
Page 12
– USB1 – Status LEDs
The USB1 is equipped with a single LED indicator above the USB
port. The following chart indicates the available LED status
information:
LED State Status
Off No power/boot
Blinking Green Booting
Green Normal Powered State
Blinking Yellow Identify
Blinking Red Muted
– USB1 – USB Audio Modes
The USB1 supports 16-bit/48 kHz audio with three configurable
sound card options with which the USB audio interface will declare
itself.
o 1x1 Speakerphone (no host AEC)
o 1x1 Speakerphone (host AEC)
o 2x0/1x0 Line in/Line out
USB audio will be routed through the following Axiom ports based
on each corresponding audio mode. Modes are set using unIFY
Control Panel.
Mode Axiom Pair A Axiom Pair B
1 x 1 Play/Record USB Playback Mono USB Record Mono
2 x 0 Play Only USB Playback Left USB Playback Right
1 x 0 Play Only USB Playback Mono N/A
Attero Tech by QSC Axiom Product Family
User Manual
– Device Config & Workflow Overview
The USB1 may be configured for single use, or daisy-chained with
one other Axiom device.
The default configuration is for single device use with Port B
disabled and Ch2 transmitting via Port A.
Figure 11 – Switch/Label Config Options
QSC, LLC 2020 614-00063
Page 13
4 – BT1 – Overview
Attero Tech by QSC Axiom Product Family
User Manual
Figure 12 – USB1 Front Panel
The Axiom BT1 provides two-way Bluetooth connectivity and a 3.5
mm stereo audio connector, allowing users to easily
connect consumer-grade devices to the room’s audio system for
music playback or Bluetooth conference call bridging.
– BT1 – What’s in the Box
The BT1 comes supplied with the following:
o Axiom BT1 device
o Includes interchangeable white and black Decora-style
inserts
o (1) White US Single Gang Decora® cover plate w/screws
o (1) Black US Single Gang Decora® cover plate w/screws
o (2) Wall plate mounting screws
Figure 13 - Product Overview
ID Description
1 Status LED
2 Pairing Button
3 1/8” Line Input
4 Axiom Port Configuration Switch
5 Axiom Ports (A & B)
6 Mini-USB Configuration Port
QSC, LLC 2020 614-00063
Page 14
Figure 14 - Dimensional Drawing
– BT1 – Device Installation
BT1 – Mounting
A typical installation will involve mounting the wall plate into a
pre mounted wall box or mounting bracket. Before installation,
make sure the wall box where the BT1 is to be installed is prewired with a suitable cable back to an Axiom-enabled
expander/injector.
Prior to USB1 installation, ensure the power sourcing device
(Axiom expander/injector) is powered off.
Attach and unshielded CAT-5/6 cable from the Axiom-enabled
device to the Axiom port A of the USB1.
With the cable attached, carefully place the BT1 into the wall
box taking care to not trap the cabling. Once in place, secure
it with the screws provided. Once the unit is secured in the wall
box, fit the Decora plate and secure it with the screws
provided.
Now you may apply power to the Axiom-enabled
expander/injector, the unit will power up and the signal
presence LEDs should blink once quickly.
The BT1 comes in a single gang US Decora style form factor
and may be mounted in most US single old and new work back
boxes and mud-rings. Given the single gang size, the BT1 may
be mounted in larger gang boxes with other single gang form
factor products to provide flexible AV system modularity where
needed.
*Note: CAD drawings can be downloaded from the QSC
website. Please contact QSC for any further product related
information that is not accessible on the website.
Attero Tech by QSC Axiom Product Family
User Manual
QSC, LLC 2020 614-00063
Page 15
– BT1 – Status LEDs
The BT1 is equipped with a single LED indicator above the pairing
button. The following chart indicates the available LED status
information:
LED State Status
White Idle
Flashing Blue Discoverable/Pairing Mode
Blue Connected
Red Initializing
Green AUX jack connection detected
Flashing White Identify
Flashing Purple RSSI value of active Bluetooth® ≤ -90
– BT1 – Device Config & Workflow
The BT1 may be configured for single use, or daisy-chained with
one other Axiom device.
The default configuration is for single device use with Port B
disabled and Ch2 transmitting via Port A.
Figure 15 – Switch/Label Config Options
Attero Tech by QSC Axiom Product Family
User Manual
– BT1 – Device Settings
The BT1 is designed use in a number of configurable modes to
facilitate comprehensive use in professional AV applications. The
following sections describe the available modes and their
functionality.
– Bluetooth® Pairing/Connect Modes
4.3.1.1 – Manual Mode
This usage model is intended for applications where casual users
of a public venue (sports bar, spa, stadium luxury box, fitness
center) have access to connect their devices to the audio system
but headaches are minimized by eliminating automatic reconnect
and pairing history features.
In this mode, users connect their Bluetooth® audio enabled smart
device by simply pressing the front panel “PAIR” button. The
status LED will begin flashing blue to indicate that the BT1 is now
visible to other Bluetooth® devices and accepting pairings. This
pairing period lasts 60 seconds after which the status LED will
stop flashing and turn off and the BT1 will disable its Bluetooth®
interface.
*Note: The default Bluetooth friendly name visible to other
devices is “BT1-xx:xx:xx”. This name can be customized by the
installer using the unIFY Control Panel software.
If a successful pairing is made during the pairing period, the
status LED will stop flashing and turn constantly on.
To disconnect a Bluetooth device from the BT1, press and hold
the PAIR button for 5 seconds and then release it. The status LED
will turn off, and the connection will be reset. Another device may
now be connected by repeating the pairing process.
4.3.1.2 – Reconnect Mode
In this mode, the BT1 maintains a pool of the last 10 paired
devices and any previously paired device on that list will be
permitted to reconnect when in range of the BT1 without
requiring the front panel button to be pressed. The user simply
selects the BT1 friendly name on their smart device.
Any new devices that are paired are added to the paired device
list. If the list already full, a random device from the list will be
removed and the new device added in its place.
4.3.1.3 – Exclusive Mode
This mode is intended for restricted/personal use and works
similarly in operation to reconnect mode. However, rather than
allow any known device from the pairing list to reconnect, only a
specific device can be used with that particular BT1.
To setup a device as the exclusive device, set the BT1 to
“Exclusive” mode, clear the pairing list, and then pair the desired
exclusive device to the unit. The BT1 makes a note of this device
and from that point on, only that exclusive device will be allowed
to reconnect to that particular BT1 when in range. As with the
reconnect mode, reconnection is done without requiring the front
panel button to be pressed by simply selecting that particular BT1
on their smart device.
Once the BT1 has been associated with a device, both the front
panel pair button and the remote “pair” command sent via the
network are disabled and will have no effect.
QSC, LLC 2020 614-00063
Page 16
In order to attach a different device, either pairing list has to be
cleared or the device mode needs to be changed.
*Note: In all modes once paired/connected, the Bluetooth®
friendly name is able to be detected by other devices. However,
while another device may be able to pair and save to its
Bluetooth® device list when in this state, breaking the connection
of the currently active device will not be possible.
– Bluetooth® Audio Bridging
4.3.2.1 – Media Bridging (only)
In this mode (A2DP profile), users may stream audio from media
applications on the paired device. The user is protected from
errant streaming of call audio over Bluetooth® link.
The media bridging mode is an excellent solution for applications
such as hospitality, retail and fitness center background music
where users want to maintain call privacy while sharing media
audio from their device’s media applications.
4.3.2.2 – Call Bridging (only)
In this mode (HFP profile), users may stream incoming/outgoing
calls from the paired device to/from the Axon-connected input
and output. In this mode, the user is protected from errant
streaming of media audio over Bluetooth® link.
The call bridging mode provides call connectivity for conferencing
system users’ Bluetooth equipped devices to a networked audio
based conferencing system. The addition of Bluetooth
connectivity provides simple bridging of far end meeting
participants for on the fly meeting productivity and backup
conferencing connectivity in case of VoIP and Web-based
conferencing service failures.
4.3.2.3 – Call & Media Bridging
In this mode, both profiles are available giving users the ability to
control access of content (call and media) to the system from the
paired device.
*Note: If your application requires call privacy, it is recommended
to not utilize the combined call and media bridging mode as call
audio will be shared automatically over the audio connection.
Attero Tech by QSC Axiom Product Family
User Manual
– Bluetooth® Pass-through AVRCP (AV
Remote Control Protocol)
Many installed AV systems in both residential and commercial
markets feature control products with customizable user
interfaces. With a connected Bluetooth audio device as a source,
it is desirable to have access to the device information and source
content (artist / album / song) for use on the control system UI.
Additionally, the end user of the system may control the source
from any control panel that has this. This is useful if the device is
left somewhere to charge and is out of reach to simply change
songs or stop the audio playback.
Control API access is be available for the following AVRCP pass
through commands:
a) Play
b) Pause
c) Stop
d) Next Track
e) Previous Track
f) Volume Up
g) Volume Down
h) Mute
The AVRCP controls are provided within unIFY Control Panel for
system commissioning and testing.
QSC, LLC 2020 614-00063
Page 17
5 – AXP2O – Overview
Attero Tech by QSC Axiom Product Family
User Manual
The Axiom AXP2O provides analog audio output breakout,
power injection and control system connectivity to Attero Tech’s
Axiom endpoint products. The installer friendly form factor
allows it to be placed on an equipment rack shelf or mounted to
any flat surface.
Features:
Figure 16 – AXP2O Front Panel
o Analog Output - Two balanced line-level analog
outputs for connectivity to mixers, amplifiers and
signal processors.
o Axiom port - Supports connectivity to any Attero
Tech Axiom endpoint.
o RS-232 - Provides RS-232 connectivity to control
systems for extending control to supported Axiom
products (limited to one control enabled Axiom
endpoint on the Axiom bus)
o LED indication of power status
– AXP2O – What’s in the Box
The AXP2O comes supplied with the following:
o Axiom AXP2O device
o 24V AC/DC Power Supply
Figure 17 - Product Overview
ID Description
1 Axiom Port
2 Balanced Audio Output Terminal Blocks
3 RS-232 Terminal Block
4 Power Status LED
5 24V DC Power Input
QSC, LLC 2020 614-00063
Page 18
Figure 18 - AXP2O Dimensional Drawings
– AXP2O – Device Installation
– Mounting
A typical installation will involve mounting an Axiom wall plate
into a pre mounted single-gang or larger wall box, standard
drywall bracket or mud ring. Before starting, make sure the wall
box where the Axiom device is to be installed is pre-wired with a
suitable unshielded CAT5/6 cable back to the AXP2O break out
box.
With the AXP2O powered off, attach the CAT cable from the
Axiom port of the AXP2O to the RJ45 on the Axiom device.
Apply power by plugging in the 24V DC power supply to the DC
power input on the AXP2O. The power LED on the AXP2O should
illuminate green. Additionally, the Axiom wall plate should also
start up and become ready to operate.
Attero Tech by QSC Axiom Product Family
User Manual
With the cable attached, carefully place the Axiom wall plate into
the wall box taking care to not trap the cabling. Once fully in
place, secure it with the screws provided. Once the unit is secured
in the wall box, fit the Decora plate over the front of the unit and
secure it with the screws provided with it. It is recommended to
not over-tighten the screws that attach the included Decora wall
plate to prevent cracking it.
*Note: CAD drawings can be downloaded from the Attero Tech
website. Please contact Attero Tech for any further product
related information that is not accessible on the website.
QSC, LLC 2020 614-00063
Page 19
+
-
GND
Pin 1
Pin 3
Pin 2
1
12
3
XLR-M
2-Wire Cabl e + Shield
Or 3-Wire Cable
TRS Plug
+
-
GND
Sleeve
Tip
Ring
2-Wire Cabl e + Shield
Or 3-Wire Cable
TRS Plug
+
-
GND
Sleeve
Tip
Ring
Output 2
Output 1
+
-
GND
2-Wire Cable
+ Shield
2-Wire Cable
+ Shield
RCA (R)
+
-
GND
Tip
RCA (L)
Tip
Output 2
Output 1
+
-
GND
Sleeve
Sleeve
– Audio Connections
The AXP2O provides balanced audio outputs to external analog
audio equipment. Refer to the following diagrams for connecting
the outputs of the AXP2O to audio devices.
Attero Tech by QSC Axiom Product Family
User Manual
– 3rd Party Control
The RS-232 port on the AXP2O break-out box is intended for
connectivity to 3
of Axiom into professional AV applications.
– RS-232 Interface
The RS-232 interface on the AXP2O is a pass through interface to
the Axiom port. Actual serial port settings can be found on select
Axiom products that support R2-232 control integration features.
rd
party control systems for extended integration
Figure 19 - AXP2O to Balanced Input Wiring Guide
Figure 20 - AXP2O to Unbalanced Input Wiring Guide
QSC, LLC 2020 614-00063
Page 20
6– AXPio – Overview
Attero Tech by QSC Axiom Product Family
User Manual
– USB1 – Device Installation
The Axiom AXPio provides switchable analog audio input/output
breakout, power injection and control system connectivity to
Attero Tech’s Axiom endpoint products. The installer friendly
form factor allows it to be placed on an equipment rack shelf or
mounted to any flat surface.
Features:
Figure 21 – AXPio Front/Back Panels
o Analog I/O - Two balanced switchable line-level
analog inputs/outputs with pad/gain controls for
connectivity to mixers, amplifiers and signal
processors.
o Axiom port - Supports connectivity to any Attero
Tech Axiom endpoint.
o RS-232 - Provides RS-232 connectivity to control
systems for extending control to supported Axiom
products (limited to one control enabled Axiom
endpoint on the Axiom bus)
o LED indication of power status
– AXPio – What’s in the Box
The AXPio comes supplied with the following:
o Axiom AXPio device
Figure 22 - Product Overview
ID Description
1 Axiom Port
2 RS232 Terminal Block
3 Power Status LED
4 24V DC Power Input
5 Input Pad Control
6 I/O Mode selection switch
7 Output Gain Control
8 Balanced Audio I/O (based on Mode selection)
QSC, LLC 2020 614-00063
Page 21
Figure 23 - AXPio Dimensional Drawings
– Mounting
A typical installation will involve mounting an Axiom wall plate
into a pre mounted single-gang or larger wall box, standard
drywall bracket or mud ring. Before starting, make sure the wall
box where the Axiom device is to be installed is pre-wired with a
suitable unshielded CAT5/6 cable back to the AXPio break out
box.
With the AXPio powered off, attach the CAT cable from the Axiom
port of the AXPio to the RJ45 on the Axiom device.
Apply power by plugging in the 24V DC power supply to the DC
power input on the AXPio. The power LED on the AXPio should
illuminate green. Additionally, the Axiom wall plate should also
start up and become ready to operate.
Attero Tech by QSC Axiom Product Family
User Manual
With the cable attached, carefully place the Axiom wall plate into
the wall box taking care to not trap the cabling. Once fully in
place, secure it with the screws provided. Once the unit is secured
in the wall box, fit the Decora plate over the front of the unit and
secure it with the screws provided with it. It is recommended to
not over-tighten the screws that attach the included Decora wall
plate to prevent cracking it.
*Note: CAD drawings can be downloaded from the QSC website.
Please contact Attero Tech by QSC for any further product related
information that is not accessible on the website.
QSC, LLC 2020 614-00063
Page 22
+
-
3-Wi re Cab le
Pin 1
Pin 2
GND
Bala nced
Terminal Block Plug
Pin 3
1
2
3
XLR-M
+
-
3-Wi re Cab le
Sle eve
Tip
GND
Ring
1
2
3
TRS Plug
Bala nced
Terminal Block Plug
Balanced Output
Terminal Block Plug
2-Wire Cable
Sleeve
Tip
TS Plug
Balanced Output
Terminal Block Plug
+
-
2-Wire Cable
Sleeve
Tip
RCA Plug
GND
+
-
GND
Bala nced
Terminal Block Plug
2-Wire C able
Sleeve
Tip
TS Plug
+
-
GND
Bala nced
Terminal Block Plug
2-Wire C able
Sleeve
Tip
RCA Plug
+
-
GND
Hardware Connections
The AXPio provides balanced line-level audio connections to
external analog audio equipment. Refer to the following
diagrams and instructions for connecting different types of
audio devices to the input and/or outputs of the AXPio.
Professional grade audio cabling is recommended to achieve the
best audio performance throughout the system.
Attero Tech by QSC Axiom Product Family
User Manual
– Balanced to Balanced Wiring
Figure 25 - Balanced Wiring Guide
Figure 24 - I/O ports/wiring
Balanced to Unbalanced Wiring
Figure 26 – Unbalanced Wiring Guide
– Unbalanced to Balanced Wiring
QSC, LLC 2020 614-00063
Figure 27 – Unbalanced Wiring Guide
Page 23
– Audio Configuration
Based on the I/O mode selected the device can be configured with
two options.
Attero Tech by QSC Axiom Product Family
User Manual
– 3rd Party Control
The RS-232 port on the AXPio break-out box is intended for
connectivity to 3
of Axiom into professional AV applications.
– RS-232 Interface
rd
party control systems for extended integration
Figure 28 - I/O configuration pots
– Input Settings
The line-level input pads are adjusted using 2 rotary pots. A small
screwdriver is needed to adjust the input pad levels. The inputs
have an adjustable attenuation range of +24 to 0 dBu, allowing
an input full scale input signal range of 0 dBu to +24 dBu.
– Output Settings
The output gains are adjusted using 2 rotary pots. A small
screwdriver is needed to adjust the gain levels. The outputs have
an adjustable gain range of 0 to +24dB, allowing for full scale
output levels of 0 dBu to +24 dBu.
The RS-232 interface on the AXPio is a pass through interface to
the Axiom port. Actual serial port settings can be found on select
Axiom products that support R2-232 control integration features.
QSC, LLC 2020 614-00063
Page 24
Attero Tech by QSC Axiom Product Family
User Manual
QSC, LLC 2020 614-00063
Page 25
Attero Tech by QSC Axiom Product Family
User Manual
ARCHITECTS & ENGINEERS SPECIFICATION
ML1
The single gang mount interface unit shall have two potentiometers on the front panel for gain control of the 3.5mm input and the balanced
input independently.
The unit shall have a 3.5mm stereo consumer level input and a ¼”/XLR combo Mic/Line input. This input is amplified and sent to the Axiom
bus. The XLR input shall be dedicated for dynamic microphone signals, while the ¼” input may be used to interface balanced line level audio
sources to the Axiom bus.
The unit shall have a selector switches for audio channel routing on the top of the unit.
There shall be two bi-color signal presence and level indicator LEDs on the front of the unit. One for the balanced input and one for the
3.5mm input.
The unit shall have two 8P8C RJ45 type connectors on the back side of the unit.
The unit shall support daisy chain of up to 1 other Axiom device, using 2 RJ45 (8P8C style connectors) for connectivity to CAT-X cabling.
The device shall support mounting the mounting of multiple units side by side in a multi-gang wall box or one unit in a single gang US wall
box.
The unit shall be the Attero Tech Axiom ML1.
USB1
The single gang mount interface unit shall have a USB type-B connector on the front panel for connecting to PC or Mac.
The unit shall have software switchable options for 1x1, 2x0, or 1x0 audio routing. This audio is sent over the Axiom bus.
The unit shall have selector switches for audio channel routing on the top of the unit.
The unit shall have a USB mini type-B connector for software configuration of the unit.
There shall a single bi-color status LED on the front of the unit.
The unit shall have two 8P8C RJ45 type connectors on the back side of the unit.
The unit shall support daisy chain of up to 1 other Axiom device, using 2 RJ45 (8P8C style connectors) for connectivity to CAT-X cabling.
The device shall support mounting the mounting of multiple units side by side in a multi-gang wall box or one unit in a single gang US wall
box.
The unit shall be the Attero Tech Axiom USB1.
BT1
The single gang mount interface unit shall have a 3.5mm stereo consumer level TRRS input/output and a Bluetooth® 3.0 compatible audio
receiver/transmitter in a Decora form factor. These inputs/outputs are sent to the Axiom bus.
The unit shall support media and/or call bridging functionality via Bluetooth® connection.
The unit shall have selector switches for audio channel routing on the top of the unit.
The unit shall have a USB mini type-B connector for software configuration of the unit.
There shall be two bi-color signal presence and level indicator LEDs on the front of the unit. One for the balanced input and one for the
3.5mm input.
The unit shall have two 8P8C RJ45 type connectors on the back side of the unit.
The unit shall support daisy chain of up to 1 other Axiom device, using 2 RJ45 (8P8C style connectors) for connectivity to CAT-X cabling.
The device shall support mounting the mounting of multiple units side by side in a multi-gang wall box or one unit in a single gang US wall
box.
The unit shall be the Attero Tech Axiom BT1.
QSC, LLC 2020 614-00063
Page 26
Attero Tech by QSC Axiom Product Family
User Manual
AXP2O
The device shall have an 8P8C connector for connectivity to Axiom bus compatible products.
Two 3-position de-pluggable terminal blocks provide balanced analog audio breakout from the Axiom port for connectivity to the balanced
or unbalanced inputs of external audio equipment.
A single, 3-postion de-pluggable terminal block provides RS-232 pass through connectivity to the Axiom port
The 24VDC input provides power injection to the Axiom port/bus.
The interface shall be compliant with the RoHS directive.
The device shall be the Attero Tech Axiom AXP2O.
AXPio
The flange mount interface unit shall two installer selectable analog inputs or outputs. The line-level analog inputs shall have an attenuation
range of +24 to 0 dBu, allowing an input full scale input signal range of 0 dBu to +24 dBu. The line-level analog outputs shall have a gain
range of 0 to +24dB, allowing for full scale output levels of 0 dBu to +24 dBu.
The device shall have an 8P8C connector for connectivity to Axiom bus compatible products.
Two 3-position de-pluggable terminal blocks provide balanced analog audio breakout from the Axiom port for connectivity to the balanced
or unbalanced inputs or outputs of external audio equipment.
A single, 3-postion de-pluggable terminal block provides RS-232 pass through connectivity to the Axiom port
The 24VDC input provides power injection to the Axiom port/bus.
The interface shall be compliant with the RoHS directive.
The device shall be the Attero Tech Axiom AXPio.
QSC, LLC 2020 614-00063
Page 27
REACH
REACH
Device Specifications
ML1 Specs
Audio Inputs (Mic/Line)
Connector Type XLR – ¼” Combo
Gain 0 to 50 dB
Input Impedance >2kOhms at any gain (mic) >10kOhms Line
Maximum Input Levels
THD+N <0.05% @ 1 kHz, -3 dBFS input, 20-20kHz
Frequency Response 20-20 kHz, +/- 1 dB (1/4”), 50-20kHz +/- 1 dB (XLR)
Dynamic Range >110 dB at minimum gain
EIN -115 dBu
Connector Type 3.5mm TRS
Gain 0 to 20 dB
Input Impedance >10K ohms at any gain
Maximum Input Levels +12 dBu @ minimum gain
+20 dBu @ minimum gain (XLR)
+18 dBu @ minimum gain (1/4”)
Audio Inputs (3.5 mm Line)
Attero Tech by QSC Axiom Product Family
User Manual
Axiom
Physical Layer Analog Audio, RS-232 Control, 24V DC Power
Connector (s) 8P8C
Cable Quality CAT-5e or better, UTP
Power Specifications
DC Power 24V DC (via Axiom port)
Power Consumption 50mA @ 24V / 1.2W
Physical Dimensions
Width 1.66”
Height 1.14”
Depth 2.35”
Weight 0.35 lbs.
Regulatory Compliance
Certifications
WEEE
RoHS
THD+N <0.05% @ 1 kHz, -3 dBFS input. 20-20kHz
Frequency Response 20-20 kHz, +/- 1 dB
Dynamic Range >110 dB at minimum gain
USB1 Specs
USB
Connector Type
Audio Connectivity
Input Impedance >2kOhms at any gain (mic) >10kOhms Line
Maximum Input Levels
THD+N <0.05% @ 1 kHz, -3 dBFS input, 20-20kHz
Frequency Response 20-20 kHz, +/- 1 dB (1/4”), 50-20kHz +/- 1 dB (XLR)
Dynamic Range >110 dB at minimum gain
Connector Type 3.5mm TRS
Gain 0 to 20 dB
Input Impedance >10K ohms at any gain
Maximum Input Levels +12 dBu @ minimum gain
USB Type B
USB Mini Type B (for configuration)
USB Audio 1.1, Compatible with Windows 7 or newer,
and MacOS 10.7 or newer
+20 dBu @ minimum gain (XLR)
+18 dBu @ minimum gain (1/4”)
Audio Output (3.5 mm Line)
Environmental Operating Specifications
Operating Temperature
0 to 40° C
Axiom
Physical Layer Analog Audio, RS-232 Control, 24V DC Power
Connector (s) 8P8C
Cable Quality CAT-5e or better, UTP
Power Specifications
DC Power 24V DC (via Axiom port)
Power Consumption 50mA @ 24V / 1.2W
Physical Dimensions
Width 1.66”
Height 1.14”
Depth 2.35”
Weight
Regulatory Compliance
Certifications
WEEE
RoHS
THD+N <0.05% @ 1 kHz, -3 dBFS input. 20-20kHz
Frequency Response 20-20 kHz, +/- 1 dB
Dynamic Range >110 dB at minimum gain
Operating Temperature
Environmental Operating Specifications
0 to 40° C
QSC, LLC 2020 614-00063
Page 28
REACH
REACH
BT1 Specs
Audio Inputs (Bluetooth/Line)
Input Types
Bluetooth Range 10m (30ft) minimum
Input Impedance >10k Ohms Line (3.5mm)
Maximum Input Levels
THD+N <0.05% @ 1 kHz, -3 dBFS input, 20-20kHz
Frequency Response 20-20 kHz, +/- 1 dB (1/4”), 50-20kHz +/- 1 dB (XLR)