AIR CIRCULATOR ASSEMBLY AND
INSTALLATION INSTRUCTIONS
WARNING
!
Read Carefully– This instruction sheet contains vital information for the proper installation, use, and efficient operation of the fan described. Carefully read this manual before installation, cleaning, or operation of the fan. Failure to adhere to the instructions could result in fire, electrical shock, death, serious personal injury, or property damage. Save these instructions and review frequently for continuing safe operation and instructing future users.
CAUTION – TO REDUCE RISK OF FIRE AND ELECTRIC SHOCK:
1. Before servicing or cleaning unit, unplug power to fan to prevent power from being switched on accidentally.
2. Installation workand electrical wiringmust be doneby qualified person(s)in accordance with all applicable codes and stan­dards, including fire-rated construction.
3. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
CAUTION: DO NOT MOVE FAN WHILE BLADE IS MOVING. ALWAYS TURN FAN OFF AND LET BLADE STOP BEFORE ATTEMPTING TO MOVE. DO NOT USE BLADE GUARD TO MOVE FAN.
SAVE THESE INSTRUCTIONS
IMPORTANT: REVIEW ALL THE ASSEMBLY INSTRUCTIONS AND CHECK FOR MISSING OR DAMAGED PARTS PRIOR TO STARTING ASSEMBLY.
In most cases, your fan head will come pre-assembled at the factory prior to shipping, if not, follow instructions titled “Fan Head Unassembled”.
1. Remove fan head assembly from carton and check for missing or damaged parts.
2. Choose the mount for your application from the following pages, and follow mounting instructions.
FAN HEAD UNASSEMBLED
FAN GUARD
BACK
FLAT WASHERS
Figure 1
FAN GUARD
FRONT
NUT
LOCK WASHER
1. Remove motor, fan guard (front and back) and fan blade from cartons.
2. Secure back half of fan guard to studs on face of motor using washers, lock washers and hex nuts. (See fig. 1)
3. Secure blade to motor shaft, with hub facing away from motor (Discharge Side) for commercial and industrial models. Tighten set screw to flat side of motor shaft. WARNING: Do not tighten set screw to round side of shaft as it will cause damage to shaft and blade could come off. Set screw must be tightened to flat of motor shaft. Failure to align and tighten to flat on shaft may result in damage to shaft or may allow blade to come loose.(See fig. 1).
4. Secure front half of fan guard to back by hanging guard at top and work­ing hooks together down sides and across bottom. Snap hook in place with screwdriver.
5. Follow directions for mounting head assembly on mount on the following
FAN BLADE
HUB
pages (Pedestal or Wall).
ADJUSTABLE PEDESTAL COLUMN
1. Remove 2 sections of adjustable pedestal column from carton(See fig. 2). Remove oval grommet from parts package and install in oval slot near top of pedestal column, Remove large round grommet from parts package. Turn grommet “inside out” so that groove is on the inside and the smooth side is on the outside. Install grommet over bottom lip of pedestal column. Feed power cord down through top of black section (end with screw holes). Slide adjustment collar into black section, align screw holes and secure. Secure adjustment collar to low-
OVAL GROMMET
Remove oval grommet from parts
ackage and install in oval slot
p
ear top of pedestal
n
Figure 2
LARGE ROUND GROMMET
emove large round grommet from
R parts package.
Turn grommet “inside out” so that groove is on the inside and the smooth side is on the outside.
Install grommet over bottom lip of pedestal column.
Figure 3
Remove 2 phillips head screws.
st height for assembly (See fig. 3).
e
2. Remove base from carton and insert medium rubber grommet into hole on surface of fan base.(See fig. 3)
3. Feed power cord from bottom of column down through center hole of fan base and then back through hole with rubber grommet. (See fig. 3).
4. Align holes in flange at base of column with holes in top of fan base. Secure by using 5/16” x 1” carriage bolts, external tooth star washers, and hex nuts. (See fig. 3). One of the carriage bolts is to be attached with the 5/16” internal tooth star washer mounted under the bolt head.
5. Secure fan head assembly to upper column using 1/2” x 1” hex bolt, star washers, lock washers and hex nuts; and 1/4” x 1” bolt, washer, lock washers, and hex nut. (See fig. 4).
6. Loosen adjustment collar and extend fan to proper height. Tighten collar and connect power cord from column to power cord on motor.
7. Refer to nameplate for proper supply voltage. Plug power cord from fan into any 120 VAC 3-prong grounded outlet for all 120 volt rated units. Units rated 220V or 277V are not supplied with attach­ment plugs. These units may be hard wired to a junction box or provided with the required 15 amp, 3 prong grounded plug rated at 250V or 277V as per nameplate rating of the fan unit.
Align and secure with
2 phillips head screws.
Figure 5
RUBBER GROMMET
Figure 4
FIXED PEDESTAL COLUMN
1. If fixed pedestal column comes un-assembled,
put two sections together, align holes at union, and secure with screws. Power cord for this model is external. Follow items 2, 4, 5 & 7 for balance of installation.