ELEMENT USED WITH MODEL NO. TYPE VOLTS WATTS FIXTURE 2-MS-08-208 208
2-MS-08-240 240 2-MS-08-277 Metal 277 850 2-MS-08-347 Sheath 347 2-MS-08-480 480 2-MS-08-600 600 RP22
2-QT-10-208 Quartz 208 RS22 2-QT-10-240 Tube 240 1000 RP32 2-QT-10-277 277 RS32
2-QL-16-208 208 2-QL-16-240 240 2-QL-16-277 Quartz 277 1600 2-QL-16-347 Lamp 347 2-QL-16-480 480 2-QL-16-600 600
ELEMENT USED WITH MODEL NO. TYPE VOLTS WATTS FIXTURE 4-MS-20-208 208 4-MS-20-240 240 4-MS-20-277 Metal 277 2000 4-MS-20-347 Sheath 347 4-MS-20-480 480 4-MS-20-600 600 RP24 4-QT-20-208 208 RS24 4-QT-20-240 240 RP34 4-QT-20-277 Quartz 277 2000 RS34 4-QT-20-347 Tube 347 4-QT-20-480 480 4-QT-20-600 600 4-QL-36-347 Quartz 347 3650 4-QL-36-480 Lamp 480 4-QL-36-600 600
ELEMENT USED WITH MODEL NO. TYPE VOLTS WATTS FIXTURE 3-MS-15-208 208 3-MS-15-240 240 3-MS-15-277 Metal 277 1500 3-MS-15-347 Sheath 347 3-MS-15-480 480 3-MS-15-600 600 RP23 3-QT-15-208 208 RS23 3-QT-15-240 240 RP33 3-QT-15-277 Quartz 277 1500 RS33 3-QT-15-347 Tube 347 3-QT-15-480 480 3-QT-15-600 600 3-QL-25-208 208 3-QL-25-240 240 3-QL-25-277 Quartz 277 2500 3-QL-25-347 Lamp 347 3-QL-25-480 480 3-QL-25-600 600
!
WARNING
Read Carefully - This instruction sheet contains vital infor-
mation for the proper installation, use, and efficient operation of the heater component described. Carefully read this manu­al before installation, cleaning, or operation of the heater. Failure to adhere to the instructions could result in fire, electri­cal shock, death, serious personal injury, or property damage. Save these instructions and review frequently for continuing safe operation and instructing future users.
1. Disconnect all power coming to heater at main service panel before attempting to disassemble heater or install elements.
2. All wiring must be in accordance with local and National
SAVE THESE INSTRUCTIONS
Electrical Codes and the heater must be grounded as a pre­caution against possible electric shock.
3. Verify the power supply voltage coming to the heater matches the rating printed on the heater nameplate before energizing.
4. For quartz lamp elements, cut away excess lead wire after installation into heater to prevent a possible electric shock or short circuit.
5. Do not handle quartz lamp or quartz tube with bare hands, as salt in perspiration may deteriorate the quartz.
6. Ceramic parts are easily broken. Use care when working with ceramic parts.
Figure 1
M
etal Sheath
E
lements
(2 req'd)
#10 Screws
10-32x1/2" Screw (2 req'd) Washer (2 req'd) 1
0-32 Nut (2 req'd)
1215-2174-000 Bracket (
2 req'd)
2
900-0025-000 Insulator
(
2 req'd)
M
etal Sheath Elements (
3 req'd)
#
10
Screws
10-32x1/2" Screw (
3 req'd) Washer (3 req'd) 1
0-32 Nut (3 req'd)
Mounting Brackets 1 With 2 Mounting Holes 2
With 1 Mounting Hole
2900-0025-000 I
nsulator
!
WARNING
Figure 2
Excess element lead wires could come in contact with the heater enclosure and create a shock or fire hazard.
CUT OFF ALL EXCESS LEAD MATERIAL.
Installation of Quartz Lamp Element
Remove terminal cover at each end of fixture to gain access to terminal blocks. Loosen #10 hex nut on terminal stud, then wrap element lead around terminal one full turn as shown in Figure 1, Step 2. Tighten nut, making sure there is some slack in the lead after the attachment is made.
Installation of Quartz Tube Element
Remove terminal cover at each end of fixture to gain access to terminal blocks. Loosen #10 hex nut and install element as shown in Figure 2.
Installation of Metal Sheath Element
All unit sizes:
Remove terminal cover at each end of fixture to gain access to terminal blocks. Loosen #10 hex nut, then attach one end of element to terminal stud as shown in Figure 2.
24 Inch Units:
Attach element to other end terminal block and replace ter­minal covers.
33 Inch and 46 Inch RP2 and RS2 Two Element Units:
With one element attached to terminal, slide insulator over metal sheath element and attach opposite end of element. Complete assembly as shown in Figure 3 using bracket with one mounting hole. Discard extra hardware and bracket with two mounting holes. Replace terminal covers.
Figure 3 RP2 or RS2
Figure 4 RP3 and RS3
RP3 and RS3 Three Element Units:
With one element attached to terminal, slide insulator over metal sheath element and attach opposite end of element. Complete assembly as shown in Figure 4 using bracket with one mounting hole on outside element and using bracket with two mounting holes on middle element. Discard extra hardware and mounting brackets. Replace terminal covers.
All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installa­tion, except metal sheath elements which are warranted against defects in workmanship and materials for two years and quartz tube / quartz lamps for two years from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation. The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to Marley Engineered Products Service Center.Within the limitations of this warranty, inoperative units should be returned to the nearest Marley authorized service center or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products. THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MER­CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DIS­CLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAM­AGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization, include all catalog numbers shown on the products.
HOW TO OBTAIN WARRANTY SERVICE AND WARRANTY PARTS PLUS GENERAL INFORMATION
Note: When obtaining service always have the following:
1. Warranty Service or Parts 1-800-642-4328