QMark B10 QMark B10 Mounting Guide

V
ERTICAL
S
ECTION
6-32 x 3/8" MOUNTING SCREWS
VIEW "A" VIEW "B"
ROTATE HUB
HUB
LOOSEN SIX SCREWS
ROTATE HUB
Mechanical Accessories
VERTICAL SECTION
VIEW "B"
1/2" (12.7mm) SPACER
10-32 NUT
ANEMOSTAT DIFFUSER
10-32 x 3/4" M
OUNTING
SCREWS
10-32 x 3/8" MOUNTING SCREWS
10-32 NUT
VERTICAL SECTION
VIEW "A"
ANEMOSTAT DIFFUSER
For MUH, HUHAA, Dayton 3UF75 - 3UF98 and 2YU58 - 2YU81,
3END3 and 3END4 Series Unit Heaters
INSTALLATION OF VERTICAL SECTION
Common Part for Radial and Anemostat Diffusers)
(
RDM, RDS, RDL, ADM, ADS, ADL, 2E592 and 2YU34
1. Remove louvers from front of heater by gripping louver close to
spring and compressing spring until other end of the louver is free.
2. For Dayton Unit Heaters - Remove bird screen from venturi opening.
3. Position vertical section over venturi outlet and rotate vertical section
4. Secure vertical section with four No. 6-32 x 3/8” (9.5mm) mounting
screws (supplied) as shown in Figure 1.
Figure 1. Installation of Vertical Section
INSTALLATION OF RADIAL DIFFUSER
RDM, RDS, RDL, 2E592 and 2YU34
1. Mount vertical section (supplied as part of radial diffuser). (Refer to
INSTALLATION OF VERTICAL SECTION above.)
2. Loosen all six screws in radial diffuser hub until blades move freely
(See Figure 2, View A).
3. Rotate the radial diffuser hub clockwise until the radial diffuser can
be inserted into the vertical section.
4. Insert blade rods into matching holes in vertical section while rotat-
ing the radial diffuser hub counter-clockwise. (See Figure 2, View B).
5. Center all blades radially and tighten screws enough to allow each
blade to rotate yet maintain a set position.
6. Rotate each blade to desired position and tighten screws to secure
blades.
INSTALLATION OF LOUVERED DIFFUSER
ON HUHAA & DAYTON HEATERS
DS, LDM and LDL
L
1. Louvers may be left in place or removed from the heater. (Refer to
Step 1, INSTALLATION OF VERTICAL SECTION).
2. Place louvered diffuser against front of unit. NOTE: Position locating tabs toward the top and sides of heater
flange.
3. Secure louvered diffuser to heater with three (3) screws (provided)
through the mounting tabs.
INSTALLATION OF ANEMOSTAT DIFFUSER
ADM, ADS, AND ADL
1. Mount vertical section (supplied as part of anemostat diffuser).
(Refer to INSTALLATION OF VERTICAL SECTION.)
2. For small (-S) and large (-L) diffusers, slide anemostat over vertical
section and secure with three No. 10-32 x 3/8” (9.5mm) bolts and nuts. (See Figure 3, View A).
3. For medium (-M) diffuser, slide anemostat into vertical section and
secure with three No. 10-32 x 3/4” (19mm) bolts, nuts and spacers. (See Figure 2, View B).
Figure 3. Installation of Anemostat Diffuser
1. Louvers may be left in place or removed from the heater. (Refer to
2. Insert mounting springs into four 3/16” (4.8mm) holes in inside
3. Place louvered diffuser against front of unit. NOTE: Position locating tabs toward the top and sides of heater
flange.
4. Secure louvered diffuser to heater by using long-nosed pliers to
Figure 2. Installation of Radial Diffuser
INSTALLATION OF LOUVERED DIFFUSER
ON MUH HEATERS LDS, LDM and LDL
Step 1, INSTALLATION OF VERTICAL SECTION ).
flange of front cover.
hook free ends of springs into four 3/16” (4.8mm) holes in inside flange of louvered diffuser.
INSTALLATION OF MOUNTING BRACKETS
B10, B20, B30, B50, 6X966, 6X967, 3UG64, 3UG65,
2YV16, 2YV17, 2YU91 and 2YU92
WARNING
THE BUILDING STRUCTURE AND THE ANCHORING PROVI­SIONS MUST BE SUFFICIENT TO SUPPORT THE COMBINED WEIGHT OF THE HEATER AND MOUNTING BRACKET.
1. Locate the position of the heater wall mounting bracket. Refer to
Figure 4 for minimum mounting clearances. Refer to Figure 5 for mounting bracket dimensions.
WARNING
MOUNTING BRACKET MUST BE INSTALLED WITH OPENING IN BRACKET TOWARD REAR OF HEATER.
2. The hole locations for the mounting bracket can be determined by
holding the bracket in position and marking through the holes. Mounting bracket dimensions with hole locations are also given in Figure 5.
3. A minimum screw size of 3/8-inch (9.5mm) diameter should be used
to mount the bracket to the wall or ceiling. A heavy washer should be used between the bolt head and the bracket. USE THE TYPE OF SCREW THAT IS BEST SUITED TO THE BUILDING STRUCTURE.
4. Remove four bolts and washers from top of heater and secure unit
mounting bracket to top of heater using the four bolts and washers. (See Figure 6).
5. Bolt the unit mounting bracket to the wall mounting bracket using
one 1/2-13 pivot bolt, two flat washers, one split lockwasher, and one 1/2-13 nut. (See Figure 7).
1
V
Q
C
EILING
S
IDE
W
ALL
V
Q
H
Q
C
EILING
S
IDE
W
ALL
C
EILING
B
ACK
W
ALL
B
RACKET TO SIDE BRACKET TO REAR
B
RACKET TO REAR
H
EATER HEATER HEATER
Minimum Mounting Clearances For Horizontal Discharge
3/4"
C
D
1
-1/2"
L
B
A
E
M
1-1/2"
UNIT MOUNTING BRACKET
OPENING MUST FACE REAR OF HEATER
WASHER
MOUNTING BOLTS
H
EA
TER
FRO
NT
AA
BB
HEATER
BACK
5/16" BOLTS,
LOCKWASHERS
AND NUTS
(4 LOCATIONS)
BRACKET
ATTACHMENT BOLT
(4 LOCATIONS)
WALL MOUNTING BRACKET
CEILING MOUNT
1
/2-13
NUT
1/2" SPLIT L
OCKWASHER
1
/2"
FLAT WASHER
1/2" FLAT WASHER
1/2-13 B
OLT
Heaters Ceiling Side Wall Back Wall H (Min.) V (Min.) Q
3 KW - 5 KW 2” (51mm) 6” (152mm) 9” (229mm) 13” (330mm) “0” 183/16” (462mm)
7.5 KW - 10 KW 6” (152mm) 6” (152mm) 13” (330mm) 151/2” (394mm) 2” (50mm) 277/8” (708mm) 15 KW - 20 KW 6” (152mm) 9” (229mm) 121/2” (318mm) 181/2” (470mm) 2” (50mm) 277/8” (708mm) 25 KW - 50 KW 16” (406mm) 12” (305mm) 18
Figure 4. Mounting Bracket Clearances
Model No. Used on
B10, 6X966, 2YV16 3 - 10 KW
B20, 6X967, 2YV17 15 - 20 KW B30, 3UG64, 2YU91 25 - 30 KW B50, 3UG65, 2YU92 40 - 50 KW
1
/2” (470mm) 251/2” (648mm) 105/8”
(270mm)
463/16” (1173mm)
Heater Size
Dimensions 3-20 KW 25-50KW
A7 B9 C7 D1 E2 L 201/2” (521mm) 285/16” (719mm)
M9
1
/4” (184mm) 97/16” (240mm)
1
/2” (241mm) 143/8” (365mm)
1
/4” (184mm) 121/8” (308mm)
15
/16” (49mm) 21/16” (52mm)
1
/4” (57mm) 3” (76mm)
15
/16” (253mm) 1415/16” (380mm)
Figure 5. Mounting Bracket Hole Dimensions
Catalog No. Used on
CMB-10 3 - 10 KW CMB-20 15 - 20 KW CMB-30 25 - 30 KW CMB-50 40 - 50 KW
Figure 6. Installation of Unit Mounting Bracket
INSTALLATION OF CMB MOUNTING BRACKETS
1. Mount bracket per step 4 of Installation of Mounting Brackets, page 1.
2. Hang heater from ceiling using center hole in unit mounting bracket,
maintaining clearances shown in Figure 4.
6/09 ECR 38318 5200-2303-502
Figure 7. Installation of Heater on Mounting Bracket
INSTALLATION OF MOUNTING BRACKETS
VDMB5, VDMB20, VDMB50, 3UG05, 3UG06, 3UG08,
2YU83, 2YU84 and 2YU85
WARNING
THE BUILDING STRUCTURE AND THE ANCHORING PROVISIONS MUST BE SUFFICIENT TO SUPPORT THE COMBINED WEIGHT OF THE HEATER AND MOUNTING BRACKET.
1. Locate the position of the vertical discharge mounting bracket. Refer to
Figure 4 for minimum mounting clearances. Refer to Figure 8 for brack­et dimensions.
2. A minimum screw size 3/8” diameter should be used to mount two of the
brackets to the ceiling. A heavy washer should be used between the bolt head and the bracket. Use the type of screw that is best suited
to the building structure.
3. Remove four bolts and washers from the back of the heater and secure
the other two brackets to the back of the heater using the four bolts and washers.
4. Bolt the unit mounted brackets to the ceiling mounted brackets using the
3/8” bolts, split lockwashers and nuts provided. See Figure 8.
3/8” BOLTS
Model No. KW AB
VDMB5, 3UG05, 2YU83 3 - 5 KW 6” (152mm) 61/8” (156mm) VDMB20, 3UG06, 2YU84 7.5 - 20 KW 87/8” (225mm) 61/8” (156mm) VDMB50, 3UG08, 2YU85 25 - 50 KW 121/2” (318 mm) 121/8” (308mm)
Figure 8. Installation of Heater on Mounting Bracket
2
470 Beauty Spot Rd. East Bennettsville, SC 29512 USA
Notes / Notas / Notes
3
V
ERTICAL
S
ECTION
6-32 x 3/8" MOUNTING SCREWS
VIEW "A" VIEW "B"
ROTATE HUB
HUB
LOOSEN SIX SCREWS
ROTATE HUB
Accesorios Mecánicos
VERTICAL SECTION
VIEW "B"
1/2" (12.7mm) SPACER
10-32 NUT
ANEMOSTAT DIFFUSER
10-32 x 3/4" MOUNTING SCREWS
10-32 x 3/8" MOUNTING S
CREWS
10-32 NUT
VERTICAL S
ECTION
VIEW "A"
ANEMOSTAT DIFFUSER
Para Calentadores de Unidades de la Serie 3UF75-3UF98 y
2YU58 - 2YU81, 3END3 y 3END4 de Dayton, HUHAA y MUH
INSTALACION DE LA SECCION VERTICAL
(Parte Común para Difusores Radiales y Anemostáticos)
RDM, RDS, RDL, ADM, ADS, ADL, 2E592 y 2YU34
1. Saque la rejilla de ventilación del frente del calentador, agarrándola cerca del
esorte y comprimiendo a este último hasta que el otro extremo de la rejilla
r
uede suelto.
q
. En los Calentadores de Unidad Dayton - Quite la reja para detener pájaros de
2
a abertura del venturi.
l
3. Coloque la sección vertical sobre la salida del venturi y hágala girar hasta que
los agujeros de los soportes de montaje queden alineados con los agujeros que les corresponden en el frente del calentador.
4. Asegure la sección vertical con cuatro tornillos de montaje No. 6-32 x 3/8”
9,5mm) (provistos) como se muestra en la Figura 1.
(
Sección Vertical
ornillos de
T Montaje No.
6-32 x 3/8”
Figura 1. Instalación de la Sección Vertical
INSTALACION DEL DIFUSOR RADIAL
. Monte la sección vertical (provista comoparte integrante del difusor radial). (Use
1
como referencia INSTALACION DE LA SECCION VERTICAL que está arriba.)
2. Afloje los seis tornillos del cubo del difusor radial hasta que las aspas se mue-
van libremente (Estudie la Figura 2, Vista A).
3. Haga girar el cubo en el sentido de las agujas del reloj hasta que el difusor
radial se pueda insertar dentro de la sección vertical.
4. Inserte las varillas de las aspas dentro de los agujeros correspondientes en la
sección vertical mientras hace girar el cubo del difusor radial en contra del sentido de las agujas del reloj. (Estudie la Figura 2, Vista B).
5. Centre todas las aspas radialmente y apriete los tornillos lo suficiente para
permitir que cada aspa gire pero al mismo tiempo mantenga una posición fija.
6. Haga girar cada una de las aspas hasta la posición deseada y apriete los
tornillos para asegurarlas.
INSTALACION DEL DIFUSOR CON REJILLA DE VENT-
ILACION EN LOS CALENTADORES HUHAA Y DAYTON
LDS, LDM Y LDL
. Las rejillas de ventilación se pueden dejar en sus lugares o sacarlas del
1
calentador. (Use como referencia el Paso 1, INSTALACION DE LA SECCION
ERTICAL).
V
. Coloque el difusor con rejilla de ventilación contra la parte frontal de la unidad.
2
OTA: Coloque las lengüetas de ubicación en sus posiciones, orientadas
N
acia la parte superior y los costados del reborde del calentador.
h
. Asegure el difusor con rejilla de ventilación al calentador, usando los tres (3)
3
tornillos (provistos) a través de las lengüetas.
INSTALACION DEL DIFUSOR ANEMOSTATICO
ADM, ADS Y ADL
1. Monte l a secció n ver tic al (provista como parte i ntegrante del d ifusor
anemostático). (Use como referencia INSTALACION DE LA SECCION
ERTICAL.)
V
2. Cuando use difu sores pequ eños (-S) o gr andes (-L) , dej e deslizar el
anemostato sobre la sección vertical y asegúrelo con tres pernos 10-32 x 3/8” (9,5mm) y tuercas. (Estudie la Figura 3, Vista A).
. Si usa un difusor mediano (-M), deje deslizar el anemostato dentro de la sec-
3
ión vertical y asegúrelo con tuercas, separadores y tres pernos No. 10-32 x
c 3/4” (19mm). (Estudie la Figura 2, Vista B).
ornillos de
T
Montaje
10-32 x 3/4”
Separador
de 1/2”
(12,7mm)
Difusor Anemostático
ornillos de
T
Montaje
10-32 x 3/8”
Difusor Anemostático
Tuerca
0-32
1
ección
S
ertical
V
VISTA “A”
Figura 3. Instalación del Difusor Anemostático.
VISTA “B”
ección
S
ertical
V
Tuerca
0-32
1
1. Las rejillas de ventilación se pueden dejar en sus lugares o sacarlas del
2. Inserte los resortes de montaje en los cuatro agujeros de 3/16” (4,8mm) que
3. Coloque el difusor con rejilla de ventilación contra la parte frontal de la unidad. NOTA: Coloque las lengüetas de ubicación en sus posiciones orientadas
hacia la parte superior y los costados del reborde del calentador.
4. Asegure el difusor con rejilla de ventilación al calentador, usando pinzas finas y
CUBO
HAGA GIRAR EL
CUBO
Afloje los seis tornillos
HAGA GIRAR EL
CUBO
VISTA “A” VISTA “B”
Figura 2. Instalación del Difusor Radial
INSTALACION DEL DIFUSOR CON REJILLA DE
VENTILACION EN LOS CALENTADORES MUH
LDS, LDM Y LDL
calentador. (Use como referencia el Paso 1, INSTALACION DE LA SECCION VERTICAL).
están en la parte interna del reborde de la cubierta frontal.
largas para enganchar los extremos sueltos de los resortes en los cuatro agu­jeros de 3/16” (4,8mm) que están en la parte interna del reborde del difusor.
INSTALACION DE LOS SOPORTES DE MONTAJE
B10, B20, B30, B50, 6X966, 6X967, 3UG64, 3UG65,
2YV16, 2YV17, 2YU91 y 2YU92
ADVERTENCIA
LA ESTRUCTURA DEL EDIFICIO Y LA FORMA DE ANCLAJE PROVISTA DEBERAN TENER LA FORTALEZA SUFICIENTE PARA SOPORTAR EL PESO COMBINADO DEL CALENTADOR Y EL SOPORTE DE MONTAJE.
1. Ubique la posición del soporte de montaje de la pared del calentador. Use como
referencia la Figura 4 para conocer los espacios de separación mínimos para hacer el montaje. Utilice como referencia la Figura 5 para obtener las dimensiones del soporte de montaje.
ADVERTENCIA
EL SOPORTE DE MONTAJE SE DEBERA INSTALAR CON LA ABERTU­RA QUE TIENE HACIA LA PARTE TRASERA DEL CALENTADOR.
2. La ubicación de los agujeros para el soporte de montaje se puede determinar
sosteniendo a éste último en su posición y marcando a través de los agujeros. Las dimensiones del soporte de montaje con la ubicación para los agujeros también se presentan en la Figura 5.
3. Se deberá usar un tornillo con un tamaño mínimo de 3/8 de pulg. (9,5mm) de
diámetro para montar el soporte a la pared o al cielo raso. Se tendrá que insertar una arandela fuerte entre la cabeza del perno y el soporte. USE EL TIPO DE TORNILLO QUE MEJOR SE ADAPTE A LA ESTRUCTURA DEL EDIFICIO.
4. Saque los cuatro pernos y las arandelas de la parte superior del calentador.
Asegure el soporte de montaje de la unidad a la parte superior del calentador, usando los cuatro pernos y arandelas (Estudie la Figura 6).
5. Aperne el soporte de montaje de la unidad al soporte de montaje de la pared
usando un perno pivote de 1/2-13, dos arandelas planas, una arandela de seguridad partida y una tuerca de 1/2-13. (Estudie la Figura 7).
4
UNIT MOUNTING BRACKET
OPENING MUST FACE REAR OF HEATER
WASHER
MOUNTING BOLTS
H
EA
TER
FRO
NT
WALL MOUNTING BRACKET
CEILING MOUNT
1/2-13 N
UT
1
/2" SPLIT LOCKWASHER
1/2" F
LAT WASHER
1
/2"
FLAT WASHER
1/2-13 BOLT
AA
BB
HEATER
BACK
5/16" BOLTS,
LOCKWASHERS
AND NUTS
(4 LOCATIONS)
BRACKET
ATTACHMENT BOLT
(4 LOCATIONS)
V
Q
CEILING
S
IDE
W
ALL
V
Q
H
Q
CEILING
S
IDE
W
ALL
CEILING
BACK WALL
BRACKET TO SIDE BRACKET TO REAR
BRACKET TO REAR
H
EATER HEATER HEATER
PARED
3/4"
C
D
1-1/2"
L
B
A
E
M
1-1/2"
ATERAL
L
ALENTADOR
C
IELO RASO
C
Pared
Trasera
CALENTADOR
CIELO RASO
IELO RASO
C
CALENTADOR
PARED ATERAL
L
SOPORTE PARA EL COSTADO
SOPORTE PARA LA PARTE TRASERA
SOPORTE PARA LA PARTE TRASERA
Espacios de Montaje Mínimos Para Descarga Horizontal
Calentadores Cielo Raso Pared Lateral Pared Trasera H (Min.) V (Min.) Q
3 KW - 5 KW 2” (51mm) 6” (152mm) 9” (229mm) 13” (330mm) “0” 183/16” (462mm)
7.5 KW - 10 KW 6” (152mm) 6” (152mm) 13” (330mm) 151/2” (394mm) 2” (50mm) 277/8” (708mm) 15 KW - 20 KW 6” (152mm) 9” (229mm) 121/2” (318mm) 181/2” (470mm) 2” (50mm) 277/8” (708mm) 25 KW - 50 KW 16” (406mm) 12” (305mm) 18
Figura 4. Espacios de Separación para Soportes de Montaje
No. Modelo KW
B10, 6X966, 2YV16 3 - 10 KW
B20, 6X967, 2YV17 15 - 20 KW B30, 3UG64, 2YU91 25 - 30 KW B50, 3UG65, 2YU92 40 - 50 KW
Tamaño del Calentador
Dimensiones 3-20 KW 25-50KW
A7 B9 C7 D1 E2 L 201/2” (521mm) 285/
M9
1
/4” (184mm) 97/
1
/2” (241mm) 143/8” (365mm)
1
/4” (184mm) 121/8” (308mm)
5
1
6
1
/
” (49mm) 21/
1
/4” (57mm) 3” (76mm)
15
/16” (253mm) 1415/16” (380mm)
6
1
” (240mm)
6
1
” (52mm)
6
1
” (719mm)
Figura 5. Dimensiones de los Agujeros del Soporte de Montaje
PERNOS DE MONTAJE
ARANDELA
No. Modelo KW
CMB-10 3 - 10 KW CMB-20 15 - 20 KW
LA ABERTURA DEBERA QUEDAR HACIA LA PARTE TRASERA DEL CALENTADOR
SOPORTE DE MONTAJE DE LA UNIDAD
CMB-30 25 - 30 KW CMB-50 40 - 50 KW
1
/2” (470mm) 251/2” (648mm) 105/8”
Arandela de Seguridad Partida de 1/2”
randela Plana
A de 1/2”
Montaje del Cielo Raso
(270mm)
Soporte de Montaje de la Pared
Perno de 1/2-13
Tuerca de 1/2-13
randela Plana
A de 1/2”
463/16” (1173mm)
Figura 7. Instalación del Calentador sobre el Soporte de Montaje
INSTALACION DE SOPORTES DE MONTAJE VDMB
1. Ubiqu e la pos ición del
LA ESTRUCTURA DEL EDIFICIO Y LA FORMA DE ANCLAJE PROVISTA DEBERAN TENER LA FORTALEZA SUFICIENTE PARA SOPORTAR EL PESO COMBINADO DEL CALENTADOR Y EL SOPORTE DE MONTAJE.
soporte de montaje para la descarga vertical. Use como referencia la Figura 4 para conocer los espacios de separación mínimos para hacer el montaje. Utilice la Figura 8 para conocer las dimensiones de los soportes.
2. Se deberá usar un tornillo con un tamaño mínimo de 3/8” de diámetro para
montar dos de los soportes al cielo raso. Se tendrá que insertar una arandela fuerte entre la cabeza del perno y el soporte. Use el tipo de tornillo que
mejor se adapte a la estructura del edificio.
3. Saque cuatro pernos y las arandelas de la parte trasera del calentador.
Asegure los otros dos soportes a la parte trasera del calentador usando los cuatro pernos y las arandelas.
4. Aperne los soportes montados en la unidad a los soportes montados en el
cielo raso, usando los pernos de 3/8”, las arandelas de seguridad partidas y las tuercas que se han provisto. Estudie la Figura 8.
ADVERTENCIA
F
RENTE
D
EL
C
ALENTA
D
O
R
Figura 6. Instalación del Soporte de Montaje de la Unidad
INSTALACION DE SOPORTES DE MONTAJE CMB
1. Monte el soporte de acuerdo con el paso 4 de arriba.
2. Cuelgue el calentador del cielo raso usando en agujero del centro que está
en el soporte de montaje de la unidad, manteniendo los espacios de sepa­ración que se muestran en la Figura 4.
6/09 ECR 38318 5200-2303-502
Arandelas de
Seguridad, Tuercas y
Pernos de 3/8”
(4 lugares)
del Calentador
Perno de
Fijación
del Soporte (4
lugares)
ParteTrasera
Model No. KW AB
VDMB5, 3UG05, 2YU83 3 - 5 KW 6” (152mm) 61/8” (156mm) VDMB20, 3UG06, 2YU84 7.5 - 20 KW 87/8” (225mm) 61/8” (156mm) VDMB50, 3UG08, 2YU85 25 - 50 KW 121/2” (318 mm) 121/8” (308mm)
Figura 8. Instalación del Calentador sobre el Soporte de Montaje
5
470 Beauty Spot Rd. East Bennettsville, SC 29512 USA
T
RONÇON
V
ERTICAL
VIS DE MONTAGE DE (6-32 x 3/8 po)
VUE "A" VUE "B"
MOYEU
DESSERRER LES 6 VIS
FAIRE TOURNER
LE MOYEU
FAIRE TOURNER
LE MOYEU
Accessoires mécaniques
TRONÇON VERTICAL
VUE "B"
RONDELLE D'ESPACEMENT DE 12,7 mm (1/2 po)
ÉCROU DE 10-32
VIS DE MONTAGE (10-32 x 3/4)
VIS DE MONTAGE DE (10-32 x 3/8)
ÉCROU 10-32
TRONÇON VERTICAL
VUE "A"
DIFFUSEUR À ANÉMOSTAT
DIFFUSEUR À ANÉMOSTAT
pour radiateurs des séries MUH, HUHAA et Dayton 3UF75 - 3UF98
et 2YU58 - 2YU81, 3END3 et 3END4
ONTAGE D’UN TRONÇON VERTICAL
Pièce commune aux diffuseurs radiaux et à anémostat)
(
M
RDM, RDS, RDL, ADM, ADS, ADL, 2E592 et 2YU34
1. Retirer la claire-voie de l’avant du radiateur en saisissant celle-ci à
proximité du ressort et en compressant le ressort de façon à dégager l’autre extrémité.
2. Pour les radiateurs Dayton - Retirer la grille à oiseaux de l’ouverture de
venturi.
3. Placer le tronçon vertical sur la sortie du venturi et faire tourner le
tronçon vertical de façon à faire coïncider les trous des supports de montage avec les trous correspondants situés à la face avant du radia­teur.
4. Fixer le tronçon vertical à l’aide de quatre vis de montage (fournies) de
9,5 mm (N˚ 6-32 x 3/8) comme l’indique la figure 1.
Figure 1. Montage du tronçon vertical
MONTAGE D’UN DIFFUSEUR RADIAL
RDM, RDS, RDL, 2E592 et 2YU34
1. Monter le tronçon vertical (fourni avec le diffuseur radial dont il fait par-
tie). (Consulter la partie MONTAGE DU TRONÇON VERTICAL ci­dessus).
2. Desserrer les six vis du moyeu du diffuseur radial jusqu’à ce que les
ailettes se déplacent facilement. (Voir la figure 2, vue A).
3. Faire tourner le moyeu du diffuseur radial dans le sens horaire jusqu’à
ce que l’on puisse introduire le diffuseur radial dans le tronçon vertical.
4. Introduire les tiges des ailettes dans les trous correspondants du
tronçon vertical tout en faisant tourner le moyeu du diffuseur radial dans le sens anti-horaire. (Voir la figure 2, vue B).
5. Centrer toutes les ailettes radialement et serrer suffisamment les vis
pour permettre aux lamelles de tourner tout en conservant une position donnée.
6. Amener toutes les ailettes à la position désirée et serrer les vis pour
maintenir les ailettes.
ONTAGE D’UN DIFFUSEUR À CLAIRE-
M
VOIE SUR LES RADIATEURS HUHAA ET DAYTON
LDS, LDM et LDL
1. On peut laisser la claire-voie du radiateur en place ou la retirer. (Se
reporter au paragraphe 1, MONTAGE DU TRONÇON VERTICAL).
2. Placer le diffuseur à claire-voie contre la face avant de l’appareil. REMARQUE : Diriger les languettes de repère vers le haut et les
côtés du rebord du radiateur.
3. Fixer le diffuseur à claire-voie au radiateur à l’aide de trois vis (fournies)
passées dans les languettes de montage.
MONTAGE D’UN DIFFUSEUR À ANÉMOSTAT
ADM, ADS, et ADL
1. Monter le tronçon vertical (fourni avec le diffuseur à anémostat dont il
fait partie). (Consulter la partie MONTAGE DU TRONÇON VERTI­CAL).
2. Dans le cas des petits (-S) et des grands (-L) diffuseurs, glisser
l’anémostat sur le tronçon vertical et le fixer à l’aide de trois boulons de 9,5 mm (N˚ 10-32 x 3/8 po) et d’écrous. (Voir la figure 3, vue A).
3. Pour le diffuseur moyen (-M), glisser l’anémostat dans le tronçon verti-
cal et le fixer à l’aide de trois boulons de 19 mm (N˚10-32 x 3/4 po) d’écrous et de rondelles d’espacement. (Voir la figure 2, vue B).
Figure 3. Montage d’un diffuseur à anémostat
POSE DE SUPPORTS DE MONTAGE
B10, B20, B30, B50, 6X966, 6X967, 3UG64, 3UG65,
2YV16, 2YV17, 2YU91 et 2YU92
1. Déterminer la posi-
IL FAUT QUE LA STRUCTURE DE LA CONSTRUCTION ET QUE LES DIS POSITIONS D’AN CRAGE SOIE NT SUFFISA NTES POUR SOUTENIR LE POIDS TOTAL DU RADIATEUR ET DU SUPPORT DE MONTAGE.
AVERTISSEMENT
Figure 2. Montage du diffuseur radial
1. On peut laisser la claire-voie du radiateur en place ou la retirer. (Se
2. Introduire les ressorts de montage dans les quatre trous de 4,8 mm
3. Placer le diffuseur à claire-voie contre l’avant de l’appareil. REMARQUE : Diriger les languettes de repère vers le haut et les
côtés du rebord du radiateur.
4. Fixer le diffuseur à claire-voie au radiateur à l’aide de pinces à long bec
MONTAGE D’UN DIFFUSEUR À CLAIRE-
VOIE SUR LES RADIATEURS MUH
LDS, LDM et LDL
reporter au paragraphe 1, MONTAGE D’UN TRONÇON VERTICAL).
(3/16 po) du rebord intérieur de la plaque avant.
pour accrocher les extrémités libres des ressorts dans les quatre trous de 4,8 mm (3/16 po) du rebord intérieur du diffuseur à claire-voie.
tion du support mural de montage du radiateur. Consulter la figure 4 pour connaître les espacements minimum. La figure 5 indique les dimensions du support de montage.
AVERTISSEMENT
DIRIGER L’OUVERTURE DU SUPPORT DE MONTAGE VERS L’ARRIÈRE DU RADIATEUR.
2. On peut déterminer l’emplacement du support de montage en main-
tenant le support en place et en faisant des repères dans les trous. La figure 5 indique également les dimensions du support de montage et l’emplacement des trous.
3. Il faut utiliser une vis d’un diamètre minimum de 9,5 mm (3/8 po) pour
monter le support au mur ou au plafond. Utiliser une rondelle épaisse entre la tête du boulon et le support. UTILISER LE TYPE DE VIS QUI CONVIENT LE MIEUX À LA STRUCTURE DU BÂTIMENT.
4. Retirer les quatre boulons et rondelles du dessus du radiateur et fixer
le support de montage au-dessus du radiateur à l’aide des quatre boulons et rondelles. (Voir la figure 6).
5. Boulonner le support de montage de l’appareil au support de montage
mural à l’aide d’une cheville ouvrière 1/2-13, de deux rondelles plates, d’une rondelle-frein fendue, et d’un écrou de 1/2-13. (Voir la figure 7).
6
L'OUVERTURE DOIT SE TROU­VER FACE À L'ARRIÉRE DU RADIATEUR
RONDELLE
BOULONS DE MONTAGE
F
ACE
A
V
A
NT
D
U
RADI
A
TEUR
SUPPORT DE MONTAGE DE L'APPAREIL
SUPPORT MURAL DE MONTAGE
SUPPORT DE PLAFOND
ÉCROU (1/2-13)
RONDELLE-FREI FENDUE DE
RONDELLE PLATE DE (1/2 po)
RONDELLE PLATE DE (1/2 po)
B
OULON
(
1/2-13)
V
Q
P
LAFOND
M
UR
L
ATÉRAL
V
Q
H
Q
P
LAFOND
MUR
LATÉRAL
P
LAFOND
M
UR
A
RRIÉRE
S
UPPORT VERS LE CÔTÉ SUPPORT VERS L'ARRIÈRE
S
UPPORT VERS L'ARRIÉRE
R
ADIATEUR
R
ADIA-
T
EUR
R
ADIATEUR
Espacements minimaux de montage Pour Décharge Horizontale
3/4"
C
D
1-1/2"
L
B
A
E
M
1-1/2"
AA
BB
HEATER
BACK
5/16" BOLTS,
LOCKWASHERS
AND NUTS
(4 LOCATIONS)
BRACKET
ATTACHMENT BOLT
(4 LOCATIONS)
Radiateurs Plafond Mur latéral Mur arrière H (Min) V (Min.) Q
3 KW - 5 KW 2” (51mm) 6” (152mm) 9” (229mm) 13” (330mm) “0” 183/16” (462mm)
7.5 KW - 10 KW 6” (152mm) 6” (152mm) 13” (330mm) 151/2” (394mm) 2” (50mm) 277/8” (708mm) 15 KW - 20 KW 6” (152mm) 9” (229mm) 121/2” (318mm) 181/2” (470mm) 2” (50mm) 277/8” (708mm) 25 KW - 50 KW 16” (406mm) 12” (305mm) 181/2” (470mm) 251/2” (648mm) 105/8”
Figure 4. Espacements pour le support de montage
No. de cat. Pour modèlo
B10, 6X966, 2YV16 3 - 10 KW B20, 6X967, 2YV17 15 - 20 KW B30, 3UG64, 2YU91 25 - 30 KW B50, 3UG65, 2YU92 40 - 50 KW
Figure 7. Pose du radiateur sur un support de montage
Encombrement du radiateur
Dimensions 3 à 20 KW 25 à 50KW
A7 B9 C7 D1 E2 L 201/2” (521mm) 285/16” (719mm)
M9
1
/4” (184mm) 97/16” (240mm)
1
/2” (241mm) 143/8” (365mm)
1
/4” (184mm) 121/8” (308mm)
15
/16” (49mm) 21/16” (52mm)
1
/4” (57mm) 3” (76mm)
15
/16” (253mm) 1415/16” (380mm)
Figure 5. Dimension des trous du support de montage
INSTALLATION DES SUPPORTS DE FIXATION
VDMB5, VDMB20, VDMB50, 3UG05, 3UG06, 3UG08,
2YU83, 2YU84 et 2YU85
AVERTISSEMENT
LA STRUCTURE DE L’IMMEUBLE ET LE S DISPOSITIFS D’ANCRAGE DOIVENT ETRE SUFFISANTS POUR SUPPORTER LE POIDS COMBINE DU RADIATEUR DU SUPPORT DE FIXA­TION.
1. Identifier la position du support vertical de fixation de refoulement. Voir la figure 4 pour les dégagements minimum de fixation. Voir la fig-
No. de cat. Pour modèlo
CMB-10 3 - 10 KW CMB-20 15 - 20 KW CMB-30 25 - 30 KW CMB-50 40 - 50 KW
ure 8 pour les dimensions du support.
2. Une vis de diamètre minimum de 9,5mm doit être utilisée pour monter deux des supports au plafond. Une rondelle épaisse doit entre la tête de boulon et le support. Utiliser le type de vis qui convient le mieux à la structure de l’immeuble.
3. Retirer quatre boulons et rondelles du dos du radiateur et fixer les deux autres supports ar dos du radiateur en utilisant les quatre boulons et rondelles.
4. Boulonner les supports montés sur l’appareil sur les supports montés au plafond en utilisnat les boulons de 3/8po., les rondelles frein fendues et les écrous fournis. Voir la figure 8.
(270mm)
463/16” (1173mm)
Figure 6. Pose d’un support de montage d’appareil
POSE DES SUPPORTS DE MONTAGE CMB
1. Monter le support conformément au paragraphe 4 ci-dessus.
2. Accrocher le radiateur au plafond en utilisant le trou central du support
de fixation de l’appareil, en conservant le dégagements indiqués à la figure 4.
6/09 5200-2303-502
ECR 38318
BOULONS DE 3/8PO.
RONDELLES FREINET
ECROUS
(4 EMPLACEMENTS)
BOULON DE FIXATION
DE SUPPORT
(4 EMPLACEMENTS)
Modèle No. KW AB
VDMB5, 3UG05, 2YU83 3 - 5 KW 6” (152mm) 61/8” (156mm) VDMB20, 3UG06, 2YU84 7.5 - 20 KW 87/8” (225mm) 61/8” (156mm) VDMB50, 3UG08, 2YU85 25 - 50 KW 121/2” (318 mm) 121/8” (308mm)
Figure 8. Installation du radiateur sur les supports de fixation.
7
470 Beauty Spot Rd. East Bennettsville, SC 29512 USA
Notes / Notas / Notes
Loading...