1
READ AND SAVE THESE INSTRUCTIONS
MODELS 7100A, 7150A, 8090A, & 8100A FANS
MODELS 7100LA, 7150LA, 8090LA, 8100LA, FAN/LIGHTS
DESCRIPTION
The FAN and FAN/LIGHT models listed in these instructions are intended for use in bathrooms. However, they
can also be used in other areas where ventilation is
required. These units are approved for installation in the
ceiling above a bathtub or shower stall only when connected to a U.L. Listed GFCI protected branch circuit.
ALL FAN/LIGHT models are U.L. Listed Type I.C.
(Inherently Protected) for installation in insulated ceilings.
UNPACKING
Unpack carefully. If there are missing components or hidden damage, immediately contact your distributor or the
delivering carrier concerning discrepancies.
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
TO REDUCE RISK OF FIRE, ELECTRICAL SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Do not use this fan with any Solid-State speed control
device.
2. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the
manufacturer.
3. Before servicing or cleaning unit, switch power off at
service panel and lock service panel to prevent power
from being switched on accidentally.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
5. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer’s guideline and safety
standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring or other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. If this unit is installed over a tub or shower, it must be
marked as appropriate for the application. See product
label.
9. NEVER place a switch where it can be reached from a tub
or shower.
10. CAUTION: For General Ventilation Use Only! Do not
use to exhaust hazardous or explosive materials or vapors.
11. Not for use in kitchens.
TOOLS
Installation of your Marley Engineered Products fan is easy. No
special technical knowledge is needed; only a few ordinary
tools are required:
Screwdriver
Hammer
Saber saw, Keyhole saw, or Jig saw
Electric drill with bit
Wire cutters
Wire stripper
Wire nuts and general electrical supplies
Safety glasses
Ruler and straight edge
All hand tools should be insulated. Power tools should display
the UL Listing Mark.
FIG. 1
ROOF CAP
4” ROUND
DUCT
ROOF
FIG. 2
WALL
CAP
4” ROUND
DUCT

2
NEW HOME INSTALLATION
(MODELS: 7100A, 7130A, 7150A, 8090A, 8100A, 7100LA, 7150LA, 8090LA & 8100LA)
1. Remove grille assembly from carton and set aside until needed. Remove reflector assembly from blower unit
(MODELS: 7100LA, 7150LA, 8090LA & 8100LA) by pulling plug from receptacle, loosen mounting screws and remove through
keyhole slot. See Fig. 4.
2. Loosen three screws securing blower unit to housing and slide it toward outlet box. Carefully lift and tilt blower unit and remove
from housing. Pull motor plug from receptacle. See Figs. 3 & 4.
3. Remove outlet box cover by removing mounting screw. Retain cover and screw for reinstallation. Remove desired knockout from
housing.
4. Insert (4) mounting brackets with angles pointing away from housing. In approximate location between joist where housing will be
located, drive (2) nails (4D or 6D) 1” from bottom of joist, 11” apart leaving 1/4” of nail projecting. Position one set of mounting
brackets over nails and drop into place. Extend the remaining mounting brackets to the adjacent joist and repeat nailing procedure. Finish driving nails and adjust housing between ceiling joist. See Fig. 5.
5. Run 120V A C, 60 Hz power cables from wall switch/switches to appropriate knockout in housing. Use a BX or
Romex connector. (Refer to wiring diagram designated for the model being installed.) Connect cables from wall
switch/switches to receptacle wires using approved wire connectors. Connect ground wire to green screw or lead
in outlet box. Install outlet box cover and secure with screw provided.
6. Run four inch duct from discharge outlet to roof jack or wall cap. See Figs. 1 & 2.
IMPORTANT: Be sure nothing obstructs the discharge of the vent. Take precautions to insure that
insulation does not get into ductwork or fan discharge opening, and damper opens and closes freely.
7. Push blower motor plug into receptacle and carefully replace blower unit. Reverse procedure as noted. Tighten screws securely.
See Figs. 3 & 4.
8. Insert lamp plug of reflector assembly into lamp
receptacle on the outlet box. Align keyhole slot on reflector
assembly bracket over screw on blower unit and slide into place. Insure that protrusion in bracket aligns with hole
in blower assembly and tighten screw. Install 100 watt (maximum) type A-19 bulb and a 7 1/2 watt candelabra base C-7 bulb.
(MODELS: 7100LA, 7150LA, 8090LA & 8100LA only.)
9. Squeeze spring on plastic grille and insert into tabs located in housing. See Figs. 3 & 4. Press grille firmly into place.
OUTLET BOX
RECEPTACLE
VENTILATOR
BLACK
WHITE
GROUND SCREW
GROUND
WHITE
BLACK
BLACK
WIRING DIAGRAM
MODELS 7100, 7130,
7150, 7100A, , 7150A,
8090, 8100, 8090A, &
8100A
WALL
SWITCH
120V AC
60 HZ
SUPPLY
BLACK
WHITE
WHITE
WHITE
WIRING DIAGRAM
MODELS 7100L, 7150L,
7100LA, 7150LA, 8090L,
8100L, 8090LA, & 8100LA
LIGHT
NIGHT LIGHT
BLUE
BROWN
WALL
SWITCH
WALL
SWITCH
WALL
SWITCH
OUTLET BOX
RECEPTACLE
VENTILATOR
GROUND SCREW
GROUND
WHITE
BLACK
BLACK
BLACK
BLACK
120V AC
60 HZ
SUPPLY
CAUTION!
BE SURE ALL WIRING COMPLIES WITH LOCAL AND NATIONAL ELECTRICAL
CODES, AND HOUSING IS PROPERLY GROUNDED.

3
AIR DISCHARGE
OUTLET
OUTLET
BOX COVER
GRILLE
MOUNTING
TABS
BLOWER UNIT
GRILLE
12 1/2”
11 13/16”
7 5/8”
10”
11 1/2”
GRILLE
SPRING
BLOWER
MOUNTING
SCREWS
WIRE
CONNECTORS
MODELS:
7100A & 7150A
OUTLET
BOX COVER
GRILLE MOUNTING
TABS
BLOWER
UNIT
GRILLE
12 1/2”
12 1/2”
11 3/16”
7 5/8”
10”
GRILLE
SPRING
BLOWER
MOUNTING
SCREWS
REFLECTOR
MOUNTING
SCREW
REFLECTOR
ASSEMBLY
MODELS:
7100LA & 7150LA
FIG. 3
MOUNTING
BRACKETS
MOUNTING
BRACKETS
WIRE
CONNECTOR
(PLUG)
WIRE
CONNECTOR
(PLUG)
AIR DISCHARGE
OUTLET
WIRE
CONNECTORS
INSTALLATION IN EXISTING HOMES
(MODELS: 7100A, 7130A, 7150A, 8090A,
8100A, 7100LA, 7150LA, 8090LA & 8100LA)
1. Carefully read all previous installation instructions and follow
those applicable to your installation, including ducting and
wiring. (Figs. 1 & 2.)
2. Drill a small hole in the ceiling from below in proposed location,
then locate this hole in the attic (or crawl space).
3. In attic, mark ceiling for cutout by using housing as a template.
Using this line, make a cutout about 1/4” larger.
4. Place housing with mounting brackets installed into hole and
rest mounting brackets on sheetrock. Extend and nail all four
ends of mounting brackets.
5. Perform steps 1 through 10 as for new construction.
FIG. 5
1”
11”

4
SPECIFICATIONS:
MODEL VOLTS DUCT CFM H.V.I. Certification (Sq. Ft.)
SIZE RATING BATH KITCHEN OTHER
8090A/8090LA 120 4” 90 85 N/A 115
7100A/7100LA 120 4” 100 95 N/A 125
8100A/8100LA
7150A/7150LA 120 4” 150 140 N/A 190
Part No. 5200-2500-004 PPD 079
04/06
470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA
HOW TO OBTAIN WARRANTY SERVICE AND
WARRANTY PARTS PLUS GENERAL INFORMATION
1. Warranty Service or Parts 1-800-642-4328
2. Purchase Replacement Parts 1-800-654-3545
3. General Product Information www.marleymep.com
Note: When obtaining service always have the following:
1. Model number of the product
2. Date of manufacture
3. Part number or description