Qmark 8100FLH User Manual

1
READ AND SAVE THESE INSTRUCTIONS
MODELS 7100A, 7150A, 8090A, & 8100A FANS
MODELS 7100LA, 7150LA, 8090LA, 8100LA, FAN/LIGHTS
DESCRIPTION
The FAN and FAN/LIGHT models listed in these instruc­tions are intended for use in bathrooms. However, they can also be used in other areas where ventilation is required. These units are approved for installation in the ceiling above a bathtub or shower stall only when con­nected to a U.L. Listed GFCI protected branch circuit. ALL FAN/LIGHT models are U.L. Listed Type I.C. (Inherently Protected) for installation in insulated ceilings.
UNPACKING
Unpack carefully. If there are missing components or hid­den damage, immediately contact your distributor or the delivering carrier concerning discrepancies.
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
TO REDUCE RISK OF FIRE, ELECTRICAL SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Do not use this fan with any Solid-State speed control device.
2. Use this unit only in the manner intended by the manufa­cturer. If you have any questions, contact the manufacturer.
3. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.
4. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
5. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating and Air Conditioning Engineers (ASHRAE), and the local code authorities.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. If this unit is installed over a tub or shower, it must be marked as appropriate for the application. See product label.
9. NEVER place a switch where it can be reached from a tub or shower.
10. CAUTION: For General Ventilation Use Only! Do not use to exhaust hazardous or explosive materials or vapors.
11. Not for use in kitchens.
TOOLS
Installation of your Marley Engineered Products fan is easy. No special technical knowledge is needed; only a few ordinary tools are required:
Screwdriver Hammer Saber saw, Keyhole saw, or Jig saw Electric drill with bit Wire cutters Wire stripper Wire nuts and general electrical supplies Safety glasses Ruler and straight edge
All hand tools should be insulated. Power tools should display the UL Listing Mark.
FIG. 1
ROOF CAP
4” ROUND
DUCT
ROOF
FIG. 2
WALL
CAP
4” ROUND
DUCT
2
NEW HOME INSTALLATION (MODELS: 7100A, 7130A, 7150A, 8090A, 8100A, 7100LA, 7150LA, 8090LA & 8100LA)
1. Remove grille assembly from carton and set aside until needed. Remove reflector assembly from blower unit (MODELS: 7100LA, 7150LA, 8090LA & 8100LA) by pulling plug from receptacle, loosen mounting screws and remove through keyhole slot. See Fig. 4.
2. Loosen three screws securing blower unit to housing and slide it toward outlet box. Carefully lift and tilt blower unit and remove from housing. Pull motor plug from receptacle. See Figs. 3 & 4.
3. Remove outlet box cover by removing mounting screw. Retain cover and screw for reinstallation. Remove desired knockout from housing.
4. Insert (4) mounting brackets with angles pointing away from housing. In approximate location between joist where housing will be located, drive (2) nails (4D or 6D) 1” from bottom of joist, 11” apart leaving 1/4” of nail projecting. Position one set of mounting brackets over nails and drop into place. Extend the remaining mounting brackets to the adjacent joist and repeat nailing proce­dure. Finish driving nails and adjust housing between ceiling joist. See Fig. 5.
5. Run 120V A C, 60 Hz power cables from wall switch/switches to appropriate knockout in housing. Use a BX or Romex connector. (Refer to wiring diagram designated for the model being installed.) Connect cables from wall switch/switches to receptacle wires using approved wire connectors. Connect ground wire to green screw or lead in outlet box. Install outlet box cover and secure with screw provided.
6. Run four inch duct from discharge outlet to roof jack or wall cap. See Figs. 1 & 2.
IMPORTANT: Be sure nothing obstructs the discharge of the vent. Take precautions to insure that insulation does not get into ductwork or fan discharge opening, and damper opens and closes freely.
7. Push blower motor plug into receptacle and carefully replace blower unit. Reverse procedure as noted. Tighten screws securely. See Figs. 3 & 4.
8. Insert lamp plug of reflector assembly into lamp receptacle on the outlet box. Align keyhole slot on reflector assembly bracket over screw on blower unit and slide into place. Insure that protrusion in bracket aligns with hole in blower assembly and tighten screw. Install 100 watt (maximum) type A-19 bulb and a 7 1/2 watt candelabra base C-7 bulb. (MODELS: 7100LA, 7150LA, 8090LA & 8100LA only.)
9. Squeeze spring on plastic grille and insert into tabs located in housing. See Figs. 3 & 4. Press grille firmly into place.
OUTLET BOX RECEPTACLE
VENTILATOR
BLACK
WHITE
GROUND SCREW
GROUND
WHITE
BLACK
BLACK
WIRING DIAGRAM MODELS 7100, 7130, 7150, 7100A, , 7150A, 8090, 8100, 8090A, & 8100A
WALL
SWITCH
120V AC 60 HZ SUPPLY
BLACK WHITE WHITE WHITE
WIRING DIAGRAM MODELS 7100L, 7150L, 7100LA, 7150LA, 8090L, 8100L, 8090LA, & 8100LA
LIGHT
NIGHT LIGHT
BLUE BROWN
WALL
SWITCH
WALL
SWITCH
WALL
SWITCH
OUTLET BOX RECEPTACLE
VENTILATOR
GROUND SCREW
GROUND
WHITE
BLACK
BLACK
BLACK
BLACK
120V AC 60 HZ SUPPLY
CAUTION!
BE SURE ALL WIRING COMPLIES WITH LOCAL AND NATIONAL ELECTRICAL
CODES, AND HOUSING IS PROPERLY GROUNDED.