Qmark 790L User Manual

READ & SAVE THESE INSTRUCTIONS
MODEL 790L
ROOM-TO-ROOM
VENTILATOR
Model 790L Room-to-Room Ventilator
draws air from one room and circulates it
in another. This will aid in distributing the
heat from a fireplace or stove to other
months, it will also help in circulating air
from a window air conditioner.
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel
to prevent power from being switched on accidentally.
3. Installation work and electrical wiring should be done by qualified person(s) in
accor-
dance with all applicable codes and standards, including fire-rated construction.
4. Sufficient air is needed for proper combustion and exhausting of gases through flue
(chimney) of fuel burning equipment to prevent back drafting. Follow the heating equip-
ment manufacturer’s guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other
hidden utilities.
6. This fan is suitable for use with Solid-State speed control devices.
LIMITED WARRANTY
Dear Customer:
Thank you for your interest in Marley Engineered Products bath fans. We’re sure you will enjoy its
benefits for many years to come. Please take a minute to fill out the following information and keep it
in your permanent records.
Date Purchased Date Installed
Model Number
LIMITED WARRANTY
This Marley product is warranted to be free of defects in material and workmanship for 12 months
from date of original purchase.
Elements for baseboard heaters are warranted for 10 years from the date of original purchase.
There is no other warranty, express or implied, except such as is expressly set forth herein. Seller will
not be liable for any general, consequential, or incidental damages, including without limitation any
damages for loss of use or loss of profits, for any breach of warranty or for negligence.
Seller’s liability and buyer’s exclusive remedy are limited to the repair of defective goods or the
shipment of equivalent goods, or the granting of a reasonable allowance on account of any
defects, as the seller may elect.
TO OBTAIN PERFORMANCE UNDER THIS WARRANTY, YOU MUST:
1. Contact the Marley Engineered Products Service Department at 1-800-642-HEAT between
the hours of 8:30 a.m. and 5:00 p.m., E.S.T., Monday through Friday.
2. Provide the model number of the product, the date of installation, and state the nature of the
difficulty being experienced.
3. The Marley Engineered Products Service Representative will determine the best way to
resolve the difficulty.
Products within warranty, which have been installed and returned to the seller for repairs will be
repaired and returned as used products. Repairs to products outside the warranty period will be
subjected to labor and parts charges.
Some states have enacted legislation which: (a) does not allow the inclusion of limitations on inci-
dental or consequential damages; (b) does not allow limitations on the length of a warranty period;
(c)
precludes exclusion, during the period of a limited warranty, of any implied warranties of merchantabil-
ity or fitness for purpose.
To the extent of such provisions being applicable in your state, the limitations in this warranty may
not apply.
TO ENSURE SAFE OPERATION
• Be sure that this unit is correctly installed and wired by a qualified installer in accordance with
the instructions and applicable NEC or equivalent codes.
• Be sure that operating instructions are followed and that moving and heating parts are kept
clean and free from obstructions.
Any warranties granted or liabilities assumed hereunder will not apply to goods that have been
damaged in transit, altered, repaired, installed or operated otherwise than in conformity with the above
requirements for safe operation.
Part no. 5200-2526-001 ECR 36989 9/06
HOW TO ORDER REPAIR PARTS
In order to obtain any needed repair or replacement
parts, warranty service or technical information, please
contact Marley Engineered Products Service Center toll-
free by calling 1-800-642-HEAT.
When ordering repair parts, always give the informa-
tion listed as follows:
1. The Part Number
2. The Model Number
3. The Part Description
4. Date of Manufacture
470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA
NOT SUITABLE FOR USE OVER COOKING EQUIPMENT. SEE
ILLUSTRATION.
DO NOT MOUNT IN A FIRE-RATED WALL.
OUTSIDE SLEEVE
OUTLET BOX
INSIDE SLEEVE
MOTOR & BLADE
BRACKET
CONTROL
CONTROL
KNOB
SCREW (FROM INSIDE
ON BOTH SIDES)
AIR FLOW
FIG. 2
INSTALLATION
1. Determine location of ventilator. Locate wall studs, being careful of obstruc-
tions. Remember to leave enough clearance for the outlet box.
2. Mark and cut round hole as close to a stud as possible at desired location
in wall. Hole should be 9
1
8” in diameter.
3. Remove ventilator from carton and disassemble. Remove control knob
and grille cover knob. Remove grille cover. Remove motor bracket
assembly by loosening screws and twisting bracket clockwise. Be sure to
unplug motor and control from outlet box. Remove two screws which
secure inside and outside sleeves together. Pull sleeves apart. See
Figure 2.
4. Establish air flow direction desired and install outside sleeve (without junc-
tion box) in room to be exhausted into. Slide inside sleeve (with junction
box) from other side of wall into place and secure with two screws. This will
trap the wall between the sleeve flanges and hold ventilator in place. If
sleeves cannot be clamped tightly enough to secure housing in wall, screw
or nail to stud through any of holes or slots in sleeve. (Be sure power to
supply line is off.)
5. Remove outlet box cover and outlet box. Run power cable from
source into back of outlet box, and secure with proper clamp.
6. Attach ground supply lead to ground terminal in outlet box (green screw).
Attach supply leads to receptacle wires, white to white and black to black.
All wiring must meet all local and N.E.C. codes.
7. Carefully replace outlet box and cover securely being sure not to pinch any
wires.
8. Replace motor and bracket assembly by carefully plugging in motor and
control into their respective receptacles and placing key hole slots in bracket
over screws. Twist to lock bracket in place, centering blade in housing
before securing screws.
9. Replace grille covers and knobs.
DO NOT INSTALLABOVE
OR INSIDE
THIS AREA
45˚
45˚
COOKING
EQUIPMENT
FLOOR
Loading...