Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Safety Precautions for Explosion Proof Products
Please follow the instruction below to ensure safe and correct use of explosion proof products.
1. Explosion proof products should be managed according to explosion proof regulations. Do not disassemble, assemble, alter or repair
the product arbitrarily.
2. The temperature rating of the product is the temperature the product will experience at the applied rated voltage and ambient
temperature indicated.
3. Use cable glands that satisfy the product’s explosion proof grade and temperature grade.
4. Unused cable entries must be lled with material that meets the explosion proof grade and temperature rating.
5. Before installing the product, please make sure all cautions indicated on the labels, packaging, and operation manual of the product
are fully understood.
6. Installation, maintenance and repair of the product must be performed by experts in the explosion proof eld, or persons who have
received relevant training.
7. For safety, the product should be installed and operated in environments that avoid high temperature and high pressure.
8. Please follow general safety precautions and avoid installing the product in locations that may generate excessive heat.
9. When installing the product in places where chemicals are located, please make sure that the environment does not have two or more
incompatible chemicals mixed. For safety, please read the instruction manual carefully and be mindful of the chemical compositions
where the product is used.
Precaution for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn o the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a re to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point.
(Failure to follow these instructions may lead to re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to re, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device.
(Failure to follow this may cause damage to property, re, electric shock and loss of life.)
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the
product that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn o the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s specication.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, re, and electric shock.
QTEX series
Please scan the QR code for more
detailed product information.
www.qlight.com
Page 2
Ordering Specications
QTEX
[Model number]
||||
• QTEX
• QTEXB
Product Specications
■
Explosion Proof Specications
Model number
Range for
operating voltage
Ex mark
Ambient operating
temperature
Explosion proof
group/ Zone
QTEXB
QTEX
AC/DC 12V to 24V
AC 110V to 220V
IECEx - Ex db IIC T6 Gb / Ex tb
IIIC T85°C Db
ATEX - II2G Ex db IIC T6 Gb
/ II2D Ex tb IIIC T85°C Db
KCs - Ex d IIC T6
–40°C ≤ Ta ≤ 60°C
II 2G, II 2D
-
3
[Layer count][Voltage][Color]
• 1-1Layer
• 2-2Layers
• 3-3Layers
• 4-4Layers
• 5-5Layers
Zone
denitions(Gas)
Group
denitions(Gas)
Maximum surface
temperature of
electrical equipment
Zone
denitions(Dust)
Group
denitions(Dust)
-
• 12-DC12V
• 24-DC24V
• 110/220-AC110V-220V
Zone 1
Zone 2
GROUP II A
GROUP II B
GROUP II C
Zone 21
Zone 22
GROUP II A
GROUP II B
GROUP II C
T1
T2
T3
12
High risk gas/vapour
Medium risk gas/vapour
Acetone, Petrol, Methanol, Propane, Toluene
Ethylene, City gas
Hydrogen, Acetylene, Carbon sulphide
450
°C
300°C
200°C
High risk powder/dust
Medium risk powder/dust
Ignitible bers/yings(more than 0.5mm)
Non-conductive dusts
Conductive dusts
-
T4
T5
T6
RAG
R-Red
A-Amber
G-Green
B-Blue
W-White
135
100
85
°C
°C
°C
■
General Product Specications
Model
number
QTEX
(Steady/
Flashing)
Layer
Voltage Current
count
AC/DC12V 0.085A
AC/DC12V 0.064A
1
110V-220V
AC/DC12V 0.150A
AC/DC12V 0.099A
2
110V-220V
AC/DC12V 0.210A
AC/DC12V 0.129A
3
110V-220V
AC/DC12V 0.270A
AC/DC12V 0.159A
4
110V-220V
AC/DC12V 0.330A
AC/DC12V 0.189A
5
110V-220V
AC
AC
AC
AC
AC
Max.
0.052A
Max.
0.067A
Max.
0.083A
Max.
0.098A
Max.
0.113A
• Protection rating : IP66
Certicate
WeightColor
4.01kg
4.01kg
R-Red
4.02kg
4.15kg
R-Red
4.15kg
G-Green
4.16kg
4.31kg
R-Red
4.31kg
A-Amber
G-Green
4.32kg
4.46kg
R-Red
A-Amber
4.46kg
G-Green
B-Blue
4.47kg
R-Red
4.61kg
A-Amber
4.61kg
G-Green
B-Blue
4.62kg
W-White
Model
number
QTEXB
(Steady/
Flashing)
Layer
Voltage Current
count
AC/DC12V 0.175A
AC/DC12V 0.134A
1
110V-220V
AC/DC12V 0.240A
AC/DC12V 0.169A
2
110V-220V
AC/DC12V 0.300A
AC/DC12V 0.199A
3
110V-220V
AC/DC12V 0.360A
AC/DC12V 0.229A
4
110V-220V
AC/DC12V 0.430A
AC/DC12V 0.259A
5
110V-220V
AC
AC
AC
AC
AC
Max.
0.077A
Max.
0.092A
Max.
0.106A
Max.
0.121A
Max.
0.135A
Certicate
WeightColor
4.11kg
4.11kg
R-Red
4.12kg
4.25kg
R-Red
4.25kg
G-Green
4.26kg
4.41kg
R-Red
4.41kg
A-Amber
G-Green
4.42kg
4.56kg
R-Red
A-Amber
4.56kg
G-Green
B-Blue
4.57kg
R-Red
4.71kg
A-Amber
4.71kg
G-Green
B-Blue
4.72kg
W-White
23
Page 3
CABLE ENTRY 3/4" NPT
218
54.5
82.5
15
168.5273
30
108
156.5
74
156.5
236
471.5
Ø124
4-Ø9
FITTING HOLES
Ø144
108
Ø144
Dimensions
(Units : mm)
QTEX/ QTEXB - Direct mount type model
30
Ø124
471.5
168.5273
82.5
4-Ø9
FITTING HOLES
456.5
15
CABLE ENTRY 3/4" NPT
74
54.5
156.5
218
236
※
product(QTEXB).
QTEX/ QTEXB - Wall mount type model
154.5
Ø124
156.5
BUZZER HOLE
Ø21.5
For QTEXB model, buzzer is located on the bottom of the
Ø144
74
4-Ø9
FITTING HOLES
54.5
282
300
370
153.527330
67.5
10
Grounding Instructions
M4 ground
contact part
148
74
CABLE ENTRY 3/4" NPT
74
156.5
154.5
•
Please use an M4 bolt at the location marked in the diagram above to ground the product.
•
When connecting the grounding cable, please use a ring terminal.
•
Please use a grounding cable with a diameter greater than 4mm.
•
Please make sure to ground the common line(-) of the product.
BUZZER HOLE
Ø21.5
※
For QTEXB model, buzzer is located on the bottom of the
product(QTEXB).
Page 4
Wiring Instructions
QTEX/ QTEXB model can be wired with either external contact and transistor.
•
When wiring with transistor, please make sure to use PNP transistor and follow the wiring instructions in the diagram below.
•
(EXTERNAL CONTACT)
Red
Amber
Green
Blue
White
Red2
Black
Gray
Orange
Violet
Flash
Common
Fuse
Steady
Layer1
Layer2
Layer3
Layer4
Layer5
Buzzer
Common
Terminal Block Wiring Instructions
OpenClose
Power (Current)
Red
Amber
Green
Blue
White
Red2
Gray
Black
Orange
Violet
(EXTERNAL TRANSISTOR-PNP)
Layer1
Layer2
Layer3
Layer4
Layer5
Common
Common
Fuse
Buzzer
Steady
Layer1
Layer2
Layer3
Layer4
Layer5
Flash
Power (Current)
RED
AMBER
GREEN
BLUE
WHITE
RED2(Buzzer)
BLACK(Flashing common)
GRAY(Steady common)
ORANGE(+)
VIOLET(-)
Power
• Disassemble the terminal block cover by turn the terminal block cover in the CCW direction using the QTEX (B) cover disassembly tool.
• QTEX model features a terminal block located inside of the housing for easy wiring. For detailed wiring instructions, please refer to the
wiring Instructions above.
• After wiring, place the cover around the top of product and turn the cover in the CW direction using the QTEX (B) cover disassembly tool.
※
Please make sure to close the terminal block cover completely to prevent failure in waterproong.
•
When wiring, please insert the wires while pushing down on the lever of each terminal box
wiring port using a terminal block screw driver(-).
•
When removing the wiring, please pull on the wire while simultaniously pushing down on the
lever of each terminal box wiring port.
※
If wires are removed while the lever of the terminal box wiring port is not pushed down,
it may cause damage to the contact point of the terminal box.
45
Page 5
Parts Denition/ Installation
4-Ø9 HOLES
54.5
218
QTEX/ QTEXB Direct mount type model
Cover(AI)
Lens(Tempered glass)
Housing(AI)
Flat washer
Spring washer
Bolt
Bracket(STS)
Cover disassembly tool
•
First, machine taps or holes on the mounting surface.
•
The mounting hole of this product is 9mm in diameter.
•
When machining taps, fasten the bolt through the mounting hole of the product.
•
When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface.
•
Based on your application needs, use a wall mount or direct mount bracket to secure the product’s cover or body to the desired mounting
QTEX/ QTEXB Wall mount type model
Cover(AI)
Lens(Tempered glass)
Bolt
Housing(AI)
Bracket(STS)
Flat washer
Spring washer
Nut
surface.
Mounting Hole Specications
•
Machine holes on the mounting surface referring
to the diagram below.
4-Ø9 HOLES
218
54.5
QTEX/ QTEXB Wall mount type modelQTEX/ QTEXB Direct mount type model
54.5
4-Ø9 HOLES
Installation Environment and Protection Rating
•
This product is designed for use with non-sparking explosion proof structure.
•
Please make sure to use the prduct in a environment where satises regulated explosion proof grading.
•
For further information, please visit our website (http://www.qlight.com).
282
Page 6
Technical Certication
•
Qlight products are designed to meet strict quality and technical standards. Thus, the Qlight brand is widely recognized for its high quality
and technical innovations from leading institutions around the world.
Specication and dimensions listen in this catalogue subject to change wuthout notice for product quality improvemont. The newest prouct information is available on our web site.(www.qlight.com)Please read the instruction Manual attached to the product carefully before installation and use.
Head Ofce | A-412, 579, Gyeongin-ro, Guro-gu, Seoul, Korea Tel. +82-80-328-2222 Fax : +82-2-2679-6154
Factory | 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-80-328-1111
Qlight Overseas Sales Dept |
185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea Tel : +82-55-328-4082
Qlight Public Relations & Marketing Team Ofce | Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-245-0017
Qlight USA, Inc. www.qlight.com www.qlightusa.com | [email protected]
3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1.408.519.5740 Fax. +1.408.519.5739