Safety Precautions
Read Operating Instructions thoroughly prior to operation. Use only a grounded outlet that is rated for your
model's electrical requirement. Do not modify the oven or factory control settings to operate the oven above the
stated maximum operating temperature. Exterior surfaces on the 180AE models may become hot to the touch
when operating at higher set temperatures. Conduct periodic maintenance as required.
Read Operating Instructions Thoroughly Prior to Operation
Set-up & Installation
Position unit in its ultimate operating location. Keep a minimum of
3" of airspace around sides & back of the unit and a minimum of 6"
above the unit. The port hole at the top of the unit will expel a small
amount of warm air through convection. This port can also be used
as an access way for an external temperature probe.
Install adjustable shelf by placing the ends of the wire shelf bracket
into the corresponding holes located on the inner sides of the oven
at the desired height. Push the ends of the bracket into the holes
until the first bends in the bracket are against the wall, then rotate
the bracket down. Place the shelf on the brackets. (FIG 1)
Place drip tray on lower shelf.
Plug the unit into a grounded outlet for your unit's rated voltage.
AB
C
FIG. 1
General Operation
The unit is ready for your immediate use. All control parameters,
calibration and tuning has been done at the factory, no adjustments
are necessary.
Push the illuminated power button. All LED's on the temperature
control will light-up for 5 seconds until the current or actual
chamber temperature is displayed. The motor will also start.
To view the set temperature press the star " " key. To change the
set temperature hold the star key together with the up (raise temp)
or down (lower temp) arrow key until the desired temperature is
indicated on the LED display. (FIG. 2) The temperature control is
set at the factory to read in 1/10th degree C (centigrade) units. To
change temperature units or display resolution see: Menu Level
Functions (page 3).
Once the unit reaches the set temperature, allow the unit to cycle for 15 minutes at set point before temperature
becomes fully stable. NOTE: Upon each initial powering-up, the control may typically overshoot the set temp by 1
or 2 degrees. After equilibrium is achieved the control will hold set temperature within 1 unit degree.
*
(PRESS)
FIG. 2
*
View Setpoint in oC / oF units
*
Increase Setpoint
*
Decrease Setpoint
*
(3 sec.) Enter/Exit Menu Levels
Chamber Loading
Article processing times and temperature uniformity are largely dependent on load density and positioning. Load
the incubator so that air circulation within the incubator is not impaired. Here are some general guidelines:
Leave a space between articles on a shelf to allow the unit's horizontal
air flow to circulate around each article. (FIG. 3)
Don't block the return air port located at the back of the lower
plenum/shelf.
Avoid extremely large (in quantity or size) or high-density loads. This
will show by non-uniform processing and long or impossible "heatÂthrough" times. To help determine a large load's suitability, use the setÂpoint recovery time (the time it takes for the temperature to recover to
the original set temperature once load is placed), as a guide. To reduce
recovery time, reduce load proportionally. When possible, measure
large loads or solution temperatures directly with an ancillary
thermometer or probe. Probes can be inserted at top port.
FIG. 3
PAG E 2
Page 3
)
Control Menu Functions
Access the menu levels for the following functions: (user applicable functions and
FUNCTION SETTING
their menu locations are high-lighted in white in the Functions Menu Guide below).
~ Change control to read in C or F temperature units.( in level 2)
~ Change to whole degree or 1/10th degree display resolution.( in level 2)
~ Run or Read temperature tracking.( or in level 3)
~ Lock Temperature setting against inadvertent adjustment.( in level 1)
~ Calibrate control temperature to an external standard.( in level 3)
FUNCTION PROMPT
FIG. 4
To access the control's function menu:
Press and hold both arrow keys for 3 seconds then release when the "tune" function prompt is displayed from
within LEVEL 1 (see "menu entry point" at the bottom of the Menu Guide below). When in the function menu
the LED display will alternate the function prompt with the function setting when keys are released. (FIG 4)
To navigate within the functions menu:
Use up and down arrow keys individually to move "right" or "left" within a level. Press and hold the star key
and then the up or down arrow keys to move "up" or "down" respectively through levels 1, 2 and 3 (Note: you
must be at prompt to move up or down levels).
To change a function setting:
Once at the desired level function prompt, press and hold the star key and press the up or down key to select
or change the function setting. Release star key to set the function. Press the up and down keys together to
return to temperature display or the control will auto-return in 60 seconds.
Functions Menu
Guide
(-2.5 to +2.5)
(oFF)
Alternating
Display
LEVEL 3
(
*
PRESS
LEVEL 2
*
(
PRESS
LEVEL 1
ON / OFF
Control Calibration Adjust
Temperature Tracking Monitor
(
)
PRESS
)
(C)
o
Ph
F
o
o
Select
NONE
C /
o
F, Bar, PSi,
C,
,
1 / 0.1
Select Display Resolution
(
)
PRESS
)
(
)
PRESS
OFF/ON
Set Temperature Lock
MENU ENTRY
POINT
IMPORTANT NOTE: The grey-shaded control functions within the menu levels are factory
tuned and set for the optimum performance and the safe operation for your model
incubator. Care should be taken when navigating or changing user applicablesettings
so as not to alter these factory settings. Factory settings for each function are listed within
the parentheses "( )" on each function tab above. Use as a trouble-shooting reference.
PAG E 3
Page 4
Temperature Tracking Feature
This feature monitors the stability of the control during for any given length process. It will record and display: 1.
The total variation or spread between high and low, 2. The absolute or maximum high and 3. The absolute or
minimum low.
To start the tracking feature navigate to "CheK" prompt in menu level 3. Hold star key then up arrow key to select
ON. Return to temp display or control will auto-return in 60 seconds. The control will track the temperature
variation until "CheK" is turned off. Recorded readings are retained until next "CheK" ON.
You can view readings at any time during or after tracking feature has been turned off. But de-powering the unit
will reset "CheK" to OFF and "rEAd" to zero. To view readings navigate to "rEAd" prompt in menu level 3. Then:
Release orPress/Hold
Displays variance
(0.6o)
TIP: To avoid erroneous tracking data from run-up temperatures or door openings, start the Tracking feature after
articles have been placed and temperature steadies at set point.
*
Press/Hold
Press once
Displays maximum
*
Press/Hold
Press once more
Displays minimum
*
Control Self Diagnostics
Control prompts will only display when a fault or alarm condition exists.
until manually reset. Typically indicates
relay or temperature control failure.
Replace relay or temp control if persists.
Example for 140 series:
PRESS
(Press together to
clear alarm condition)
Maintenance / Control Calibration
To clean interior and exterior surfaces, use a damp cloth with or without an all-purpose cleaner. The acrylic door
should only be cleaned using a lint-free cloth, with or without water. Paper towels can mar the surface of the
acrylic door. Use of any commercial cleansers on the acrylic door will cause crazing and cracking of the surface of
the acrylic over time. Periodically, check the accuracy of the control's temperature display against a known
accurate or calibrated device. This should be done with an empty chamber after the set temperature becomes
steady (typically after 45 to 60 minutes). Calibrate the control in the control's functions menu, level 3 (see page 3).
Tech Support
If you have any questions or need technical assistance, please contact Quincy Lab customer support at
Email: information@quincylab.com Quincy Lab, Inc.
Voice: 800-482-HEAT (4328) 1925 North Leamington Avenue
Fax: 773-622-2282 Chicago, Illinois 60639
Limited Warranty
Quincy Lab, Inc. warrants to the original purchaser that this product will be free from
defects in material and workmanship under normal use throughout the warranty period.
The standard warranty period for this instrument is 18 months from date of shipment.
The instrument warranty is supplemented with a 3-year warranty on the heating
element. Please refer to your invoice or shipping documents to determine the effective
warranty period. This warranty covers parts and labor (labor at factory only), and
shipping costs for replacement parts.
PAG E 4
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.