The installation of QASAIR Rangehoods must comply with the information in this booklet. QASAIR Rangehoods are
designed and made to work efciently over all domestic cookware available on the Australian market.
Clearance from cooktop to Rangehood
For electric hot plate cooktops
As there are no regulations for Rangehoods over an electric hot plate, please follow the manufacturers Instructions /
Recommendations.
For Induction cooktops
Induction cooktops may present problems with condensation on lters of Rangehoods.
All Qasair Rangehoods installed above an induction cooktop must be installed no less than 750mm between the
induction cooktop and the Rangehood, with the exception of the Eastmore (EAS) Rangehood which can be installed
no less than 600mm. Undermount (NDCH) and Conley (CON) Rangehoods are not suitable for induction cooktops.
For gas cooktops
All Qasair Rangehood installations over a gas appliance must comply with (AS/NZS 5601.1).
The Regulations for the installation of Gas Appliances (AS/NZS 5601.1) states that the clearance between the
highest part of the burner of a gas cooking appliance and a Rangehood be no less than 600mm. If the gas
appliance is designed for use without a cooking vessel like an indoor barbecue or open ame grill, then the
clearance from the cooking surface to the Rangehood shall be no less than 1200mm.
All Qasair Rangehoods installed above a gas cooktop must be installed no less than 600mm between the highest
part of the burner and the Rangehood.
The recommendation for Qasair Wallmount Rangehoods is that they be installed between 700 to 800mm above the
highest part of the burner. When the Rangehood is installed in a galley or partially enclosed kitchen the Rangehood
can be installed between 900 to 1000mm above the highest part of the burner.
Qasair Island Rangehoods should not be installed any higher than 800mm above the highest part of the burner as
any movement around the bench will result in fumes being drawn out from the catchment area of the Rangehood
with the exception of the Thermidor and Liverpool which for aesthetic reasons is installed ush with the ceiling.
Ducting
1. Every QASAIR Rangehood must be ducted to the outside atmosphere by the use of zinc-alume duct or
non-porous and non-ammable materials. Do not use of any type of exible ducting or plastic PVC piping.
Rangehoods must not be vented into a wall cavity or a ceiling space. Externally ducting the rangehood prevents
a build up of grease, which can be a re risk. Ensure the external outlet vent does not restrict the airow in any
way, as this may result in reduced performance.
2. QASAIR Rangehoods must be ducted in duct work equivalent to the outlet of the rangehood ie: The cross
sectional area of the rangehood outlet and the duct work must be equal. Do not reduce the duct size or have
sharp bends. Enlarge the duct size if the duct is to run 6 metres or longer. Advice from CONDARI is available to
ensure optimum performance. Always use nonammable materials to minimise the risk of re in the duct.
3. Ensure all ducting pieces are correctly tted and sealed with either duct tape or silicone to ensure that fumes
do not escape into the ceiling space and seep into living areas through vents or light ttings.
Qasair Rangehoods Installation Instructions4
Other Important Information
1. Always adequately ventilate the room when the rangehood is in use at the same time as appliances
burning gas or other fuels.
2. WARNING: Incorrect venting will result in additional noise and a reduction in efciency. Exhaust air must not be
discharged into any chimney or ue, which may carry combustible products from other sources.
a) Do not discharge the air-ow from the rangehood into a ue used for exhausting fumes
from burning gas or fuel;
b) For cleaning purposes please refer topage 51 of installation instructions for stainless steel;
c) If cleaning is not carried out in accordance with the instructions as listed on page 51, there may be an
increased risk of re;
d) Some parts of the rangehood may become hot when cooking;
e) This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
3. The installation and tting of the rangehood should be done in such a way that will allow the unit to be removed
if service is required. Additional costs incurred in the removal of wall tiles, damage to walls or bench tops are not
covered by warranty.
4. To reduce the risk of xing screws coming in contact with live parts, do not drill or screw into the rangehood.
Live wires are encapsulated where possible to prevent user contact. If necessary drill from the inside out and
only through single sheet material.
5. NOTE: CONDARI recommend an air movement of between 1000 to 1400 cubic metres per hour over an indoor
barbecue, depending on the length of the duct run. Ensure a twin motor unit is installed over indoor barbecues
for optimum results. Barbecues should be positioned under the centre of the hood where the fans are mounted
and not near the outer edges where leakage may occur.
6. The lights in the rangehoods are LED and come with a night light except for D400L-1 and SEN400L-1.
7. If the supply cord is damaged, an authorised service centre or licensed electrician must replace it.
8. Do not ambé under the rangehood.
9. QASAIR domestic rangehoods must not to be used over barbecues approved for outdoor use only,
CONDARI make a range of hoods specically for outdoor barbecues in alfresco areas under the CONDOR
name.
10. CONDARI can manufacture rangehoods to be used over commercial cookers in domestic applications.
12. NOTE: Ensure all requirements are met with gas and electrical regulations and or state authorities.
Qasair Rangehoods Installation Instructions
5
INSTALLATION INSTRUCTIONS
EXECUTIVE / FLINDERS RANGE
CUTOUT DIMENSIONS
MODELHOOD SIZEBASE SIZE
CON 60L243 x 580 280 x 600258 x 585280 x 600
CON 80L
NDCH 90L243 x 880280 x 900258 x 885280 x 900
NDCH 100L243 x 980280 x 1000258 x 985280 x 1000
NDCH 120L243 x 1180280 x 1200258 x 1185280 x 1200
LIS 500L390 x 480430 x 500400 x 485430 x 500
LIS 800L390 x 780430 x 800400 x 785430 x 800
LIS 900L390 x 870430 x 900400 x 885430 x 900
LIS 1000L390 x 980430 x 1000400 x 985430 x 1000
LIS 1200L390 x 1180430 x 1200400 x 1185430 x 1200
LIS 1500L390 x 1480430 x 1500400 x 1485430 x 1500
WES 60L / EAS 60L290 x 565330 x 600300 x 570330 x 600
WES 80L / EAS 80L290 x 780330 x 800300 x 785330 x 800
243 x 780 280 x 800258 x 785280 x 800
PROUD MOUNT
CUT OUT DIMENSION
FLUSH MOUNT
CUT OUT DIMENSION
WES 90L / EAS 90L290 x 880330 x 900300 x 885330 x 900
WES 100L / EAS 100L290 x 980330 x 1000300 x 985330 x 1000
WES 120L / EAS 120L290 x 1180330 x 1200300 x 1185330 x 1200
WCV 1000L560 x 980600 x 1000570 x 985600 x 1000
WCV 1300L560 x 1280600 x 1300570 x 1285600 x 1300
WCV 1600L560 x 1580600 x 1600570 x 1585600 x 1600
WCV 1800L560 x 1780600 x 1800570 x 1785600 x 1800
ETN 600L340 x 580380 x 600355 x 585380 x 600
ETN 900L340 x 880380 x 900355 x 885380 x 900
ETN 1200L340 x 1180380 x 1200355 x 1185380 x 1200
Qasair Rangehoods Installation Instructions6
DUCT DIRECTION CHANGE INSTRUCTIONS
Before installing your rangehood check whether it has the fan mounted for back or top ducting.
For top ducting, the unit will have the air outlet at the top, and for back ducting, the unit will have the air outlet at the
back.
To change from top to back or back to top, proceed as follows:
Duct direction for ETN, NDCH and CON models
The motor shown is fitted to the back plate (P) and this plate is attached to the hood by screws (S). To change from
top to back, remove the filters, unplug fan(s). Undo all the screw (S), carefully remove the plate and turn it around so
the motor points out the way required. Fit and reconnect the fan(s), and fit all the screws again and tighten.
Duct direction for LIS / FA / MT / MC / EAS and WES
To change the duct direction, proceed as follows:
1. Remove the screws from the fan access panel and remove access panel (for MT and MC models only).
2. Disconnect fan(s).
3. Unscrew the 2 x 7mm screws (B) fixing the fan to the hood. Remove fan entirely. Repeat for each fan.
4. Rotate the fan assembly and re-install so that the air outlet meets with the rangehood outlet hole through which
you are going to vent (top or back).
5. Replace the 2 x 7mm screws holding each fan.
6. Reconnect the fan(s)
7. Refit the fan access panel (for MT, EAS and WES models only).
LIS model – Rear duct
Qasair Rangehoods Installation Instructions
7
INSTALLATION INSTRUCTIONS
• MT
Installation must be carried out by the procedure outlined.
Failure to do so may void the guarantee.
Electrical: Wiring to the appliance must comply with State and local Regulations.
Connection to be carried out by a registered electrician.
• MC
1. Fit a shelf at 410mm from the base of the cupboard.
2. Note hinge location prior to drilling.
3. Work from the centre line mark and drill 4 x M5 to M8 holes.
4. For top ducted models, cut out hole for the ducting allow 20mm clearance.
5. Fix left and right hand mounting brackets (supplied) 145mm from the base of the cupboard flush with the rear
of the unit. Notch to the back.
6. Lift rangehood onto mounting brackets by holding either end. DO NOT use the slide mechanism as this may
cause damage.
7. Insert the 4 x 50mm pan head screws supplied through the shelf and into the rangehood. Turn clockwise to level
the rangehood.
8. Fix the rangehood position by inserting 2 x no 8 1/2 inch screws through the left and right hand brackets.
9. Fit doors.
10. Minor adjustments may be required on the rangehood handle. Loosen the screws on the rear of the handle and
adjust handle position and re- tighten. The rangehood handle can be replaced.
11. All of the rangehoods shown on pages 1 and 8 are supplied with a 10AMP plug and lead for connection
to a 10AMP GPO, which must be in an accessible position.
12. The handle can be removed and replaced with one made by the cabinet maker to fit in with the kitchen cabinets.
The MT 90 has 3 screws and the MT 60 has 2 screws. These can be accessed by sliding the facia out and
un-screwing the front from underneath and behind the facia. The handle will come off by tilting it forward from
the top.
Qasair Rangehoods Installation Instructions8
Mini Trim
Technical Specification Sheet
MTSlide Out
Page 1 of 1Condari Pty Ltd.
Version: B 03/12/2014F
MINI TRIM - MT
Power entry location
is the same for all
MT models.
255
395
110
120
2
0
2
0
3
8
2
275
170
0
This view is shown
with slide out trim
in closed position.
110
ModelModelMT 60L-1
Body Width
Motor Box /
Flue Width
Motor Qty
LED Light
Nightlight
Light Qty
Light Centres
Filter Qty
MT 60L-1
600mm
518mm
1
Cool
YES
1
N/A
1
MT 90L-1
900mm
518mm
1
Cool
YES
2
320mm
2
Filter Size
Conversion
Top/Back Back/Top
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Corner Type
514mm
10 Amp Lead
Square
Qasair Rangehoods Installation Instructions
x177mm
YES
N/A
N/A
N/A
N/A
MT 90L-1
x177mm
407mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
9
Condari Pty Ltd.Page 1 of 1
Version: B 03/12/2014
Marcel
Technical Specification Sheet
MCSlide Out
MARCEL - MC
2
110
455
179
255
0
110
2
0
100
This view is shown
with slide out trim
in closed position.
Power Entry
275
170
2
0
Model
Body Width
Motor Box /
Flue Width
Motor Qty
LED Light
Nightlight
Light Qty
Light Centres
Filter Qty
1000mm
918mm
2
Cool
YES
2
320mm
2
Model
Filter Size
Conversion
Top/Back Back/Top
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Corner Type
MC 1000L-2MC 1000L-2
x177mm
457mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
F
Qasair Rangehoods Installation Instructions10
INSTALLATION INSTRUCTIONS
• FA
1. The rangehood is designed to be fitted within joinery and can be installed by inserting screws in the three holes
provided on each side, or to the top or back by drilling your own mounting holes as required.
2. When installed, cover the access holes to the side fixing screws with the plastic plugs supplied.
3. Fit filters.
4. Install front panel to suit as per your kitchen design.
Installation must be carried out by the procedure outlined.
Failure to do so may void the guarantee.
Electrical: Wiring to the appliance must comply with State and local Regulations.
Connection to be carried out by a registered electrician.
Qasair Rangehoods Installation Instructions
11
Condari Pty Ltd.Page 1 of 1
Version: B 03/12/2014F
m
m
Foldaway
Technical Specification Sheet
FA
Undercupboard
FOLDAWAY - FA
450
110
Power Entry
110
2
0
2
0
300
0
1
4
4
4
200
Model
Body Width
Door Width
Motor Qty
LED Light
Nightlight
Light Qty
Light Centres
Filter Qty
FA 60L-1FA 90L-2FA 90L-1FA 60L-1FA 90L-2FA 90L-1
598mm
573.4mm
1
Cool
YES
1
Centre
2
898mm
873.4mm
1
Cool
YES
2
350mm
2
This view is shown
with door in closed
.
position
Power Entry
Model
898mm
873.4mm
2
Cool
YES
2
350mm
2
Filter Size
Conversion
Top/Back Back/Top
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Corner Type
x290mm
274mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
x290mm
424mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
x290
424mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
Qasair Rangehoods Installation Instructions12
INSTALLATION INSTRUCTIONS
FlushMount(1:4)Proud Mount(1:4)
AABB
• CON
Installation must be carried out by the procedure outlined.
Failure to do so may void the guarantee.
Electrical: Wiring to the appliance must comply with State and local Regulations.
Connection to be carried out by a registered electrician.
• NDCH
• LIS
• ETN
1. Loosen screws A and B by turning anti-clockwise.
2. Turn screw ‘D’ anti-clockwise to extend the outer spring bracket.
3. Insert rangehood into cut out and turn screw ‘C’ clockwise to align rangehood with cupboard base.
4. Do not over tighten.
5. Tighten screw ‘A’ by turning clockwise to lock xing bracket.
6. Fit off ductwork as required.
7. To remove rangehood, turn screw ‘D’ clockwise.
RANGEHOOD SPRING BRACKETS
Models: LIS
CON
MOUNTING POSITION
Models: ETNNDCH
Cupboard
PROUD MOUNT
Qasair Rangehoods Installation Instructions
Front of Rangehood
12
Front of Rangehood
12
Cupboard
FLUSH MOUNT
13
m
m
Conley
Technical Specification Sheet
CON
Undercupboard
CONLEY - CON
1
0
110
1
Power Entry
240
110
1
0
360
2
280
Model
Body Width
Motor Box /
Flue Width
Motor Qty
LED Light
Nightlight
Light Qty
Light Centres
Filter Qty
CON 60L-1CON 80L-2CON 80L-1CON 60L-1CON 80L-2CON 80L-1
600mm
580mm
1
Cool
YES
1
Centre
2
800mm
780mm
1
Cool
YES
2
379mm
2
800mm
780mm
2
Cool
YES
2
379mm
2
Power Entry
Model
Filter Size
Conversion
Top/Back Back/Top
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Corner Type
Condari Pty Ltd.Page 1 of 1
x250mm
269mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
Version: A 01/07/2014
379mm
10 Amp Lead
x157mm
YES
N/A
N/A
N/A
N/A
Square
F
x157
379mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
Qasair Rangehoods Installation Instructions14
Undermount
TechnicalSpecificationSheet
NDCH
Undercupboard
Page 1 of 2
Condari Pty Ltd.
Version: B 19/12/2014F
Power entry location
UNDERMOUNT - NDCH
1
0
110
1
2
is the same for all
NDCH models.
240
110
1
0
360
Model
Body Width
Motor Box /
Flue Width
Motor Qty
LED Light
Nightlight
Light Qty
Light Centres
Filter Qty
NDCH 90L-1
900mm
880mm
1
Cool
YES
2
770mm
2
NDCH 90L-2
900mm
880mm
2
Cool
YES
2
770mm
2
280
Model
Filter Size
Conversion
Top/Back Back/Top
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Corner Type
NDCH 90L-1NDCH 90L-2
x260mm
340mm
YES
10 Amp Lead
N/A
N/A
N/A
Square
x260mm
340mm
YES
10 Amp Lead
N/A
N/A
N/A
N/AN/A
Square
Qasair Rangehoods Installation Instructions
15
Undermount
Technical Specification Sheet
NDCH
Undercupboard
UNDERMOUNT - NDCH
240
Power entry location
is the same for all
NDCH models.