Tri-detection method
2 digital dual-element passive IR & 1 microwave doppler unit
Sensitivity
AUTO or HIGH
Temperature compensation
Digital
Up to 24kg, 1m high
Detection speed
0.25 - 2.5m/s
Tri-masking
Adjustable from 0m to 1m, covers all 3 technologies
Casing
3mm polycarbonate, 0.4mm HDPE in Lens Area. IP Rating: IP55
Lenses
UV compensated
Operating voltage & current
9 - 16V DC, (24mA @ 13.8V DC quiescent)
Relay output
3 x SELV limits, 60V DC 50mA (42.4V AC peak)
Mounting height & range
1m - 1.5m = 12m range
Tamper switches
12V DC 50mA both front and rear
Temperature
Storage: -40°C to 80°C Operating: -30°C to 70°C
Dimensions & weight
188 x 77 x 84mm, 0.3kg
Product information
Applies to electrical products sold within the European community. At the end of the electrical product’s life, do not dispose of it with household waste. Where possible, recycle the product. Check with your Local Authority or retailer for recycling advice in your country.
Warranty
This product is sold subject to our standard warranty conditions and is warranted again defects in workmanship for a period of five years (excluding lens). In the interest of continuing care and design, Pyronix Ltd reserves the right to amend specifications without giving prior notice.
Environmental Class (EC) IV
9.9GHz: AT, BE, CH, CY, CZ, DK, EE, FI, FR, GR, HR, HU, IE, IS, IT, LT, MT, NL, PL, PT, SI, TR, UAE
10.525GHz: BE, CH, CY, DK, ES, HU, IE, IS, IT, MT, MY, NL, NO, SE, SI, UAE, USA
10.587GHz: GB, MY
EN
XDL12TT-AM
RINS1900-1
1. Installation
Scan the QR code for fixing instructions and adapter information. Ensure that the detector is installed away from reflected sunlight and large objects.
2. Switches
If you disable the detector’s LEDs, you can remotely enable them in walk tests. Connect the detector’s LED terminal to a control panel PGM output that switches to 0V to enable the LEDs.
3. Microwave range and angle of detection
Use the highlighted dials to change the microwave range and angle of detection.
4. LEDs
Four LEDs show the status of the detector.
5. Lens inserts
Use lens inserts to control coverage.
6. Header pins
Place two-pin jumpers onto header pins to adjust resistance for alarm, masking/fault and tamper.
7. Anti-masking
Anti-masking triggers an alarm when part or all of the sensor is masked by an intruder. Use the highlighted dial to change the masking area range. When an intruder enters the masking area, LED2 pulses. When the intruder moves out of the masking area, if the detector does not see activation on all 3 sensors within 1 min, the mask/fault relay opens and LED1 and LED3 turn on. To reset, remove the obstruction and perform a walk test for 1 min.
8. Blocking
Blocking detects intruders behind objects when the panel is disarmed. To use blocking, move switches 3 and 4 down, and connect the R1 input to a panel output that is negative when disarmed. When blocking is active, the alarm relay opens and LED1 and LED3 turn on. To reset, perform a walk test.
9. Connecting to CCTV and lights
To connect the detector to CCTV and lights, refer to the wiring diagram.
Specifications
4m 8m 12m
1-1.5m
1-1.5m
< 24kg
1m
4m 8m 12m
1-1.5m
< 10m
4m 8m 12m
1-1.5m
> 10m
4m 8m 12m
ON
LED 1 LED 2 LED 3
LED 4
Top PIR activated
Bottom PIR activated
Microwave activated
Alarm
Powering up
Low voltage
Top PIR failed self-test
Bottom PIR failed self-test
Microwave failed self-test
Masked / blocked
Mask processing
12m
1.3m
1.3m
~8m
0m
12m
12m
12m
1-1.5m
1
2
3
2
4
5
1-1.5m
4m 8m 12m
Switch
1 2 3 4 5 6 7 8
Up (ON position)
AC 230V, 50 Hz Anti-masking always on Blocking off R1 off Auto sensitivity Open mask & alarm relays Buzzer on LEDs on
Down
AC 110V, 60 Hz Anti-masking on when disarmed Blocking on when disarmed R1 on High sensitivity Open mask relay only Buzzer off LEDs off
2
2
+44(0)333 444 1280 (UK) customer.support@pyronix.com (UK) www.pyronix.com Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
+ -
TAMPER ALARM N / C
XDL12TT-AM
MASK / FAULT
PCX
+12V 0V
EOL EOL EOL
R1 LED ALARM N / O
1
6
8
9
10K 6K8 5K6 4K7 3K9 2K7 2K2 1K5 1K 820R
3K 15K 12K 8K2 6K8 5K6 4K7 2K2 1K
10K 5K6 4K7 3K9 2K7 2K2 1K5 1K
<1m
30%
0%
7
+ -
TAMPER ALARM N / C
XDL12TT-AM
MASK / FAULT
2K2 1K5 1K 820R
T
PCX
+12V 0V A
T
COM
A
EOL
EOL EOL EOL
R1 LED ALARM N / O
ALARM N/C
5K6 4K7 3K9 2K7
10K 6K8
5K6 4K7 2K2 1K
MASK / FAULT
15K 12K 8K2 6K8
10K 3K
2K2 1K5 1K
TAMPER N/C
5K6 4K7 3K9 2K7
10K
DEOL
+ -
TAMPER ALARM N / C
XDL12TT-AM
MASK / FAULT
2K2 1K5 1K 820R
T
PCX
+12V 0V A
T
COM
A
EOL
EOL EOL EOL
R1 LED ALARM N / O
ALARM N/C
5K6 4K7 3K9 2K7
10K 6K8
5K6 4K7 2K2 1K
MASK / FAULT
15K 12K 8K2 6K8
10K 3K
2K2 1K5 1K
TAMPER N/C
5K6 4K7 3K9 2K7
10K
3EOL
+ -
TAMPER ALARM N / C
XDL12TT-AM
MASK / FAULT
2K2 1K5 1K 820R
T
PCX
+12V 0V A
T
COM
A
EOL
EOL EOL EOL
R1 LED ALARM N / O
ALARM N/C
5K6 4K7 3K9 2K7
10K 6K8
5K6 4K7 2K2 1K
MASK / FAULT
15K 12K 8K2 6K8
10K 3K
2K2 1K5 1K
TAMPER N/C
5K6 4K7 3K9 2K7
10K
N/C
DEOL
N/C
+ -
TAMPER ALARM N / C
XDL12TT-AM
MASK / FAULT
T
PCX
+12V 0V A
T
COM
A
EOL
EOL EOL EOL
R1 LED ALARM N/O
NO C NC
PGM
0V
= 0V
PROGRAM OUTPUTS?
PGM [0000] Not Used
Endstation PGMs?
PGM [0022] Final Arm Any
PCX