Pyronix TMD15 User Manual

15m 50ft
10m
12m
15m
4m
6m
8m
2m
2.4m 6ft 6”
10m 12m 15m
2m 4m 6m 8m
2.4m 6ft 6”
10m 12m 15m
2m 4m 6m 8m
Minimum Range Setting
Dual Tech Lens
Volumetric 90 30 Zones 3 Planes
3mm (0.12")
PIR Lens
Volumetric 69 24 Zones 3 Planes
RINS1405-1
Coverage Pattern And Plan View
Operation of Features
VERTICAL COVERAGE
HORIZONTAL COVERAGE
Dual Tech PIR
TMD 15
2 Volumetric Lenses, with NO overlapping zones
15m Internal detector
WHITE
3mm ABS, 0.4mm HDPE in Lens Area
2 Low noise dual element passive infrared sensors and a microwave doppler unit
Selectable AUTO or HIGH
Digital
15m PIR and 1-15m microwave
0m - 1m anti-masking
27 facets,54 zones in total.
: 5 columns, 15 facets, 30 zones
90 field of view none-overlapping zones
: 4 columns, 12 facets, 24 zones
69 field of view none-overlapping zones
0.25 - 2.5m/s
9-16Vdc, 13.8Vdc typically
24mA @ 13.8Vdc Quiescent
3 x SELV limits; 60Vdc 50mA(42.4Vac peak)
1.8 - 2.4m = 15m. 3m = 12m
12Vdc 50mA both front and rear
-40 C to +80 C (-40 F to +176 F)
-30 C to +70 C (-22 F to +158 F)
EN55022 Class 2
EN50130-4
Top Lens
Bottom Lens
Model:
Colour:
Casing:
Lenses:
Detection Method:
Dual Tech Sensitivity:
Temperature Compensation:
Microwave Detection Range:
anti-mask Detection Range:
Detection Zones:
Detection Speed:
Operating Voltage:
Current Consumption:
Relay Output:
Mounting Height:
Tamper Switch:
Storage Temperature:
Operating Temperature:
Emissions:
Immunity:
Pyronix Limited, Pyronix House, Braithwell Way,
Hellaby, Rotherham, S66 8QY. UK
Customer Support Line (UK only):
+44(0)845 6434 999 or or +44(0)1709 535225
Hours: Mon to Fri, 8:00am till 6:30pm
Email: customer.support@pyronix.com
Website: www.pyronix.com
WARRANTY
This product is sold subject to our standard warranty
conditions and is warranted against defects in
workmanship for a period of five years.
In the interest of continuing improvement of quality,
customer care and design, Pyronix Ltd reserves the
right to amend specifications, without giving prior
notice.
This product is approved for use in the Residential,
Commercial and Light Industrial Environment.
TMD15 Specifications
SWITCH FEATURE POSITION MEANING
1 50/60Hz ON 50Hz
OFF 60Hz
2 Anti anti-mask ON 24 Hour
OFF Anti-anti-mask only enabled in
unset mode
3 Blocking ON Blocking processing Off
OFF Blocking processing On
4 RI1 Mode
OFF Stateof Ri1 = set/unset mode
5 Sensitivity ON Dual Tech = AUTO
OFF Dual Tech = HIGH
6 anti-mask ON Open anti-mask & Alarm relays
when in anti-mask
OFF Open anti-mask relay only when
in anti-mask
7 Operational ON Two movement detector
Mode OFF TriCover detector
8 LED Enable ON Enable LEDs
OFF Disable LEDS
ON Permanent in Set Mode
Switch Options
Suggested Specification Detail:
A dual technology (PIR/Microwave) movement detector having a range capability of 15 metres and five detection columns within an overall angle of coverage of 90 degrees. This is non-overlapping with a PIR movement detector, which has a range capability of 15 metres and four detection columns with an overall angle of coverage of 69 degrees installed in the (location) and at a height of (x) metres.
®
®
®
®
TS50131-2-4 EN50131-1 PD6662:2004
Security Grade 3 Environmental Class 2
TS50131-2-4 EN50131-1 PD6662:2004
Security Grade 3 Environmental Class 2
Switch 2. Anti-anti-mask Mode
This controls when the anti-masking algorithm is applied. When the DIP switch is (Default), the anti-masking algorithm is enabled regardless of the set/unset status of the detector. When the DIP switch is the anti-masking algorithm is enabled when the RI1 is in the unset state.
ON
OFF,
Switch 3. Blocking
Switch 1. 50/60Hz ON OFF= 50Hz = 60Hz
Initial Power Up
The EN anti-mask Operation
Self Test
Low Voltage Detect
On first power up of the TMD15G3, the detector will go into a self test, this will involve the GREEN and ORANGE LEDs flashing on the dual tech, and the RED LED flashing on the PIR. After a minute the detector will be ready. If the ORANGE LED is still flashing then the detector has failed a Microwave test, or if the GREEN LED or RED LED is still flashing then the detector has failed a PIR test, if this occurs try restarting the detector (powering down and back up).
Every 5 hours of detector none activity the detector will do an active diagnostic self test. If in the unlikely event of a failed self test the detector anti-mask/fault relay will open.
If the detector detects a low voltage fault, then the anti-mask/fault relay will open
FOR EN OPERATIONS DIPSWITCH 6 MUST BE ON
If an attempt is made to anti-mask the TMD15G3 the BLUE LED will start flashing at half a second intervals, signaling that the detector is going into ‘anti-mask processing’. anti-mask processing will take 60 seconds to complete.
For None EN operation just the anti-mask/fault relay goes open.To select which relays to open on a anti-mask activation see dip switch 6.To reset the detector to normal operating mode, remove the blocking material, the BLUE LED will then flash again and during this time the detector should be walk tested to activate both Microwave and PIR, the GREEN and ORANGE LED will distinguish after 60 seconds and the relays will be closed again.If the detector has been put into anti-mask processing by accident, you will need to walk test the detector so both the Microwave and PIR trigger, after 60 seconds the BLUE LED will stop flashing and normal operation is resumed.
If the detector still sees a anti-mask after 60 seconds then the anti-mask/fault and Alarm relays open, and the GREEN and ORANGE LEDs will be illuminated.
ON = Blocking Disabled / OFF = Blocking Enabled ‘Blocking’ works as follows: If an attempt to anti-mask the detector is made when the
control panel is disarmed, the alarm relay will be held open until the anti-masking is removed (thus not allowing the control panel to arm). Youmust also connect the
“RI 1” input on the TMD15G3 to a programmable output. When the control panel is disarmed, this input must be at 0V. When the panel is armed it must be at 12V. Toenable this feature dip switch 3 must be OFF.
®
®
®
Switch 5. Dual Tech (Alarm 1) Sensitivity
Switch 7. Operational mode
ON = TMD Mode
OFF = TriCover Detector Mode..
DIP Switch 7 determines the operational mode of the detector. When the switch is ON (default) will operate as a TMD15G3 , where the Dual Techand the Single PIR operate independently. Toopen alarm contact 1, the Dual Tech’s PIR must trigger within a given time period of the microwave sensor.Alarm contact 2 is based on the operation of the Single PIR only.
When switch 7 is OFF,the detector will operate as a TriCover detector, with all technologies needing to trigger within a given time period of each other to open alarm contact 1. Alarm contact 2 will operate in the inverse of alarm contact 1. In alarm, the only LED to be illuminated will be the Dual Techalarm LED.
Switch 8. LED Enable/Disable
Switch 4. RI 1 Mode
A link on board marked “RI1/Spare”determines if the RI1 terminal is used for the set/unset signalling or simply as a spare terminal to aid EOL wiring. If the RI1/Spare link is fitted, the state of RI1 determines if the panel is set or unset. The actions that can be performed in set and unset mode are also determined by DIP switch 4 and 2. DIP switch 4 controls the action of RI1. If the switch is the detector will operate permanently in Set Mode. When DIP switch 4 is the detector will use the state of RI1 to determine the set or unset state. A 0V applied to input RI1 is interpreted as being unset. A +12V applied to input RI1 is interpreted as being set. DIP switch 2 determines if anti-masking is enabled all of the time or only when the panel is unset. When nothing is connected to RI1, the input state is in the set state.
ON
OFF,
Switch 6. Anti-anti-mask Relay Action
®
®
®
FOR EN OPERATION DIPSWITCH 3 MUST BE OFF
ON = Open Both anti-mask and Alarm Relays Example of a control panel input looking for a anti-mask value of 13k7. See below Alarm relay = 4k7, Tamper EOL = 2k2, anti-mask/Fault relay = 6k8.
None EN operation only anti-mask relay opens. OFF = Opens anti-mask Relay Only Example of a control panel input looking for a anti-mask value of 14k2. See below Alarm relay = Closed, TamperEOL = 2k2, anti-mask/Fault relay = 12K.
ON = Auto Sensitivity / OFF = High Sensitivity
The bottom PIR will always remain in Auto Sensitivity
ON = LED Enable / OFF = LED Disable
Toremotely enable the LEDs 0V must be applied to the “LED” terminal. If used with Pyronix panels, the LED terminal must be connected to a PGM output and programmed as “Remote LED Enable”.
For Standard G3 operations the DIP switches do not need to be adjusted.
This product complies with TS50131-2-4. at security grade 3,
environmental class 2.
UK = Suitable for use with systems installed to PD6662:2004 (AMD)
EXPORT = Suitable for use with systems installed to EN50131-1
INTERNATIONAL
INTERNATIONAL
Physical Layout
+
-
TAMPER
ALARM1 ALARM2
RI1/SPARE
anti-mask/FAULTEOL
anti-mask/FAULT
RI1
LED
EOLEOLEOLEOLEOL
anti-mask/FAULT
ALARM1
ALARM
2
TAMPER
TAMPER
1K
2K2
4K7
5K6
6K8
8K2
12K
15K
3K
1K
1K
1K
1K
0
2K2
2K2
2K2
2K2
4K7
4K7
4K7
4K7
5K6
5K6
5K6
5K6
6K8
6K8
MWRange Adjust
AMAdjust
1
K
S
O
N
2
3
4
5
6
7
8
Pyro Sensor
Pyro Sensor
EOL Resistance Headers
(TAMPER, ALARM 1, anti-mask/FAULT)
Dual Tech
EOL Resistance Headers
Single PIR
(TAMPER, ALARM 2)
DIP Switches
PIR Range: 5, 10 or 15m (15m top)
Microwave
Module
LEDs
Orange (Microwave)
Blue (Alarm)
Green (PIR)
Left = Center = Right =
LED Red (Alarm)
Front Tamper
Anti-mask EOL Header
Disabled Enabled
RI1/Spare
Microwave Adjust
Decrease Sensitivity
()1m
Increase Sensitivity
()15m
Increase Sensitivity
()1m
(Must be at0.1m - 1m to be EN compliant)
FULLYANTI-CLOCKWISE
TURNS THE anti-mask OFF
Anti-mask Adjust
The Tampers
Dip Switches
Front Tamper
Back Tamper
Case Lid Screw
3K
3K
Grade 3 Configuration (DEOL)
TriCover® mode configured to a single input with anti-mask
configured to a second input
Case Lid Screw Fitting
Wall Mounting
Casing Knockouts
NOTE: When mounting the TMD 15, ensure that it is mounted vertically
Rear Tamper Break Out (See “The Tamper” section)
Make sure a 10mm gap exists between the ceiling and the top of the TMD before fixing.
PIR Range
Wall Fixing Knockouts
NOTE: IF THE RESISTOR VALUES THAT YOU REQUIRE ARENT SHOWN, PLEASE CONTACT CUSTOMER SUPPORT.
Grade 2 Configuration
Dual Tech and Single PIR Technologies
Configured To Separate Inputs (SEOL)
Dual tech to input 1
Single PIR to input 2
Single PIR
Single PIR
anti-mask/FAULT
anti-mask/FAULT
ALARM 1
ALARM 1
TAMPER
TAMPER
1K
1K
2K2
2K2
4K7
4K7
5K6
5K6
6K8
6K8
8K2
8K2
12K
12K
15K
15K
1K
1K
1K
1K
2K2
2K2
2K2
2K2
4K7
4K7
4K7
4K7
5K6
5K6
5K6
5K6
6K8
6K8
Dual Tech
Dual Tech
ALARM 2
ALARM 2
TAMPER
TAMPER
1K
1K
1K
1K
0
0
2K2
2K2
2K2
2K2
4K7
4K7
4K7
4K7
5K6
5K6
5K6
5K6
6K8
6K8
3K
Single PIR
anti-mask/FAULT
ALARM 1
TAMPER
1K
2K2
4K7
5K6
6K8
8K2
12K
15K
1K
1K
2K2
2K2
4K7
4K7
5K6
5K6
6K8
Dual Tech
ALARM 2
TAMPER
1K
1K
0
2K2
2K2
4K7
4K7
5K6
5K6
6K8
Hard Wired Resistor (This example would be 4k7)
Hard Wired Resistor (This example would be 4k7)
ANTI-MASK FAULT EOL LINK MUST
BE OFF
ANTI-MASK
FAULT EOL LINK MUST
BE OFF
ANTI-MASK FAULT EOL LINK MUST
BE OFF
The Wiring Connections For The TMD15 (Examples)
®
On Off
1
KS
ON
2
3
4
5
6
7
8
Enable LEDs
2 Movement Detector
Open Mask & Alarm Relays
Dual TechAuto Sensitivity
Set Mode
Blocking Off
24 Hour
50Hz
Disable LEDs
TriCover Detector
Open Mask Relay
Dual TechHigh Sensitivity
RI 1 Mode
Blocking On
anti-mask only in unset
60Hz
®
Grade 2 Configuration
TriCover® Mode SEOL Wired to a single input with anti-mask
configured to a second input
The back tamper operates by the use of the “rear tamper break out” section of the TMD 15. If the detector is forcibly removed the “rear tamper break out” stays attached to the wall, thus opening the back tamper.
®
®
The Installation Of The TMD15
®
10mm
+
-
TAMPER
ALARM1 ALARM2
RI1 / SPARE
anti-mask/FAULTEOL
anti-mask/FAULT
RI1
LED
EOLEOLEOLEOLEOL
anti-m
ask/F
AU
L
T
ALA
RM
1
ALAR
M
2
TAM
PER
TAM
PER
1K
2K2
4K7
5K6
6K8
8K2
12K
15K
3K
1K
1K
1K
1K
0
2K2
2K2
2K2
2K2
4K7
4K7
4K7
4K7
5K6
5K6
5K6
5K6
6K8
6K8
MWRange Adjust
AMAdjust
1
KS
ON
2
3
4
5
6
7
8
The ‘notches’ as shown above, alter the range of the PIR from 5m to 15m.
Top = 15m
Middle = 10m
Bottom = 5m
Decrease Sensitivity
()0m
NOTE: DIP SWITCH 7 MUST BE OFF
NOTE: DIP SWITCH 7 MUST BE OFF
Z2
+
-
TAMPER
ALARM 1 ALARM 2
RI1/SPARE
MASK/FAULTEOL
anti-mask/FAULT
RI 1
LED
EOLEOLEOLEOLEOL
+AUX-
Z1
COM
Z2
Z2
+
-
TAMPER
ALARM 1 ALARM 2
RI1/SPARE
MASK/FAULTEOL
anti-mask/FAULT
RI 1
LED
EOLEOLEOLEOLEOL
+AUX-
+AUX-
Z1
Z1
COM
COM
+
-
TAMPER
ALARM 1 ALARM 2
RI1/SPARE
MASK/FAULTEOL
anti-mask/FAULT
RI 1
LED
EOLEOLEOLEOLEOL