Pyroclassic Fires Pyroclassic IV Wood Burner, Pyroclassic Mini Wood Burner Installation Instruction Manual

IMPORTANT NOTE
This Pyroclassic fire is tested to AS/NZS4012 and 4013
and should be installed in accordance to AS/NZS 2918:2001.
Under no circumstances should any modification be made, or parts removed.
Doing so will result in voiding the fire’s warranty.
Pyroclassic Fires Ltd PO Box 14057, Hastings, 4159 Showroom: 917 Karamu Rd, Hastings, 4122 Ph: (06) 877 0175 or 0800 479 762
www.pyroclassic.co.nz
PLEASE ENSURE THIS SET OF INSTRUCTIONS REMAINS WITH THE OWNER TO READ
INSTALLATION INSTRUCTIONS
Model: Pyroclassic® IV Wood Burner
Model: Pyroclassic® Mini Wood Burner
Pyroclassic Fires Installation Instructions | Updated June 2017 | 2
TIPS ON INSTALLATION
POSITION THE FIRE
Using the technical specification sheets identify where the Pyroclassic fire is to be situated. Note: We can supply 2 x 10mm steel rods upon request. Push the rods through the two 11mm holes located in the front plate and engage the corresponding 11mm holes in the rear plate. The projecting ends of both rods can now be used as carry rods.
To make the whole unit lighter, the top cooking plate can be carefully removed. Replace the cook top when fire is in position.
INSULATING HEARTH (NOT SUPPLIED BY PYROCLASSIC)
Pyroclassic Fires must sit on an insulating hearth with a minimum distance of 369mm in front of the heater when the hearth is installed flush with the surrounding combustible floor. The width of the floor protector shall extend not less than 200mm each side of any ash-removal or fuel loading openings unless the floor protector forms an abutment with a wall or heat shield at a lesser distance
. If the fire is centered on the hearth then this would be a minimum width of 680mm. The seismic restraints supplied will need to be installed when using this type of hearth.
PYROCLASSIC RAISED HEARTH
Using the raised hearth allows the above mentioned 369mm distance at the front of the fuel loading and ash removal opening to be reduced. The Pyroclassic Hearth is raised 250mm from the floor thus reducing the distance at the front of the door opening to 300mm
.
The Pyroclassic Hearth has a marking hole located on top of the hearth that indicates the exact centre of the flue, you can use the measurements shown on our technical specifications pages to help position the hearth prior to installing the fire. Place the hearth into position and bolt or screw into floor in 4 places, (Fixings not supplied, installer to supply suitable fixings) using the mounting holes provided in the hearth
. Please use the provided black caps to cover the fixing
holes once the hearth has been installed. Also note that there are 4 cups on the top of the hearth, these cups are used to locate the
adjustable feet on the fire. Split pins are provided for the rear feet only to allow the fire to be anchored to the hearth, these act as the earthquake restraints meaning you don’t need to use the fixing slots and brackets in the back plate.
PYROCLASSIC WOODBIN
The woodbin supplied is designed to slide under the Pyroclassic Hearth. If the woodbin is used with a wooden or concrete floor we have supplied carpet squares which should be stuck to the underside of the woodbin, avoid sticking them too close to the edges as they can then be easily seen.
PYROCLASSIC SMALL RAISED TABLE AND WOODBIN
If the smaller option of woodbin is being used on a combustible surface then a continuous layer of non-combustible material must be used underneath to the minimum dimensions shown in the technical specifications, if required a powdercoated steel plate with fixing slots is available for this.