OPERATING INSTRUCTIONS
Model: Pyroclassic® IV Wood Burner
Pyroclassic fires are unique and work differently from other wood burners.
Please take your time to read through these instructions to maximise the benefits of
your new Pyroclassic IV.
Save these instructions for future reference.
IMPORTANT NOTE
Pyroclassic® fires have been in production for more than 30 years. Our experience, along with
other New Zealand manufacturers, is most issues relating to obtaining maximum efficiencies
come from loading the fire with wet wood (more than 25% moisture content).
The New Zealand Home Heating Association report that as much as 95% of complaints received
are a result of poor fuel.
We strongly suggest you read the 'Firewood' section on page 6 in this booklet.
![](/html/e8/e880/e88081eb5d535237fc8329a8ceab196efbce3dd89e60c5c712b5c40a86697ea6/bg2.png)
UK TEST RESULTS
(MIXED FUEL)
NZ TEST RESULTS
(SOFT WOOD)
AUS TEST RESULTS
(HARD WOOD)
5.0kW
refuelling interval
65.3% (+18% water
heating)
64.17% (including
water heating)
221°C-260°C @
nominal heat output.
5.2g/s @ nominal heat
output
Mean CO
Emission
(@13%O2)
PYROCLASSIC
®
IV OPERATING INSTRUCTIONS
FUEL TYPE: WOOD LOGS ONLY
This unit is capable of continuous operation. Please use recommended fuels only.
Maximum fuel load is 9kg - DO NOT EXCEED
This appliance is NOT suitable for use in a shared flue.
This appliance should NOT be operated with the loading door open.
WARNING: The appliance is designed to become hot during operation, care should be taken to avoid contact with
external surfaces.
New Zealand Home Heating Association maximum average output test method result: 14.2kW
Australian Home Heating Association Solid Fuel Certificate of Compliance No.H633-0811 23/8/17 (Soft wood with wetback)
Australian Home Heating Association Solid Fuel Certificate of Compliance No. H824/0215 10/2/18 (Hard wood with wetback)
Australian Home Heating Association Solid Fuel Certificate of Compliance No. H825/0215 10/2/18 (Hard wood dry)
Environment Canterbury Authorisation Number: 121121 (without wetback)
Environment Canterbury Authorisation Number: 121122 (with wetback)
Nelson Authorisation Number: 072269 (without wetback)
Nelson Authorisation Number: 073063 (without wetback)
Pyroclassic Fires Operating Instructions | Updated July 2016 | V.2 | 2
![](/html/e8/e880/e88081eb5d535237fc8329a8ceab196efbce3dd89e60c5c712b5c40a86697ea6/bg3.png)
WATER HEATING
Water heating is by low pressure thermosyphon, maximum operating pressure 10 Bar.
The capacity of the wetback is 0.5 litres.
Excess heat from the wetback boiler to the domestic hot tank should be dissipated using a ‘heat leak’ radiator. A
drain-cock must be fitted in the lowest part of the system. See Hotflow wetback installation instructions
included with the wetback for more information. A copy of these instructions can be downloaded from
www.pyroclassic.co.nz.
Minimum safe distances from unprotected combustible materials:
Back - 350mm, Side - 480mm (See technical specifications sheet on protection measures).
This appliance is not suitable for use in a shared flue system and should not be operated in a room
with another combustion heater.
WARNING: There must not be an extractor fan in the same room or space as the appliance as it may
cause the stove to emit fumes into the room.
Pyroclassic Fires Operating Instructions | Updated July 2016 | V.2 | 3
![](/html/e8/e880/e88081eb5d535237fc8329a8ceab196efbce3dd89e60c5c712b5c40a86697ea6/bg4.png)
IMPORTANT AND USEFUL INFORMATION
Thank you for purchasing the Pyroclassic® IV freestanding wood fire. At Pyroclassic Fires, we take pride in
manufacturing this high quality, low emission fire which has enjoyed over 30 years of proven reliability and high
efficiency
WARNING:
This appliance should only be installed by a trained and NZHHA qualified installer.
The appliance and flue system must be installed in accordance with AS/NZS 2918 and the appropriate
Appliances installed in accordance with this standard shall comply with the requirements of local standards
Any modification of the appliance that has not been approved in writing by the testing authority is
.
requirements of relevant building codes.
where required by the regulatory authority. It shall display compliance tag reading “Tested to AS/NZS 4013”
considered to be in breach of the approval granted for compliance with local tested standards.
Cracked and broken components e.g. glass or ceramic, may render the installation unsafe.
Maintain a clearance of at least 1m between the front of the fire and building structure or any other
substantial permanent object.
To help you obtain all the benefits the Pyroclassic® IV offers, we ask you to ensure the
following four important steps are performed:
1. Correctly complete your warranty card and return it to us either in person at our factory, or by mailing to:
Pyroclassic Fires Ltd
PO Box 14057
Hastings, 4159
New Zealand
2. The wood you use in the Pyroclassic® IV should be good quality, dry wood with a moisture content of 25%
or less, 12% - 18% is ideal for clean, efficient heat. A digital moisture meter is provided free of charge with
your fire so please use this to test your wood fuel.
3. Please read this operating manual thoroughly as even individuals who have significant experience with
wood fires will learn from this
4. Before the start of the winter season, follow this maintenance checklist on your fire:
Have the flue professionally swept using a suitable sized brush.
Ensure the door seals sufficiently all the way around.
Ensure the door spindle lines up with the hole in the front plate when the door closes and that it is
lubricated with grease.
Inspect the air tubes and load limiter assembly to ensure there are no cracks/holes that have appeared.
If so, depending on the amount of wear, consider getting replacement air tubes installed.
Remove the front panel and ensure the two primary air inlets are clear.
Make sure the turboslide is sealing flush against the front plate of the fire by looking down the side of
the decorative panel.
.
Pyroclassic Fires Operating Instructions | Updated July 2016 | V.2 | 4