Your PYLE PRO Series Compact Mixing Console
is a sophisticated control center, perfect for mixing sound from multiple signal sources such as MICROPHONES, GUITAR, GUITAR AMP,KEYBOARD, SAMPLER, DRUM MACHINE or AUDIO OUTPUT FROM A VCR. This mixer is ruggedly constructed for home or professional use. Wide range of volume controls permit you to adjust sound levels accurately to achieve just the right mix for playing through your speaker system or for recording.
Owner’s Manual Table of Contents
i Introduction
1 Safety Instructions
Care and Maintenance
2 Features and Controls: PYD6070 Mixer
3 Features and Controls: PYD1270 Mixer
4 INSTALLATION, PYD6070 Mixers
5 INSTALLATION, PYD1270 Mixers
6 Mono Input Channel Controls,
MIC/LINE/GAIN/EQ/EFX/PAN/PEAK/LEVEL/LO CUT(PYD1270)
CH1/CH2 For PYD6070
CH1/CH2/CH3/CH4 For PYD1270
7 Stereo Input Channel Controls,
LINE/EQ(PYD6070)/EFX/BAL/LEVEL/GAIN(PYD1270)
CH3/4 & CH5/6 For PYD6070
CH5/6, CH7/8, CH9/10, & CH11/12 For PYD1270
8-9 Main Section Connections and Controls
10 Specifications
11 Warranty
i – Pyle Pro Mixer PYD6070/1270 Owner’s Manual
Safety Instructions
CAUTION: To reduce the risk of electronic shock, do not remove the cover (or back). No user
serviceable parts inside; refer servicing to qualified personnel.
WARNING: To reduce the risk of fire electric shock, do not expose this device to rain and moisture.
This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage that may be sufficient to constitute a risk of shock.
This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. Please read the manual.
This device should be kept away from water or liquid to be spilled into the unit.
This device should be kept away from heat sources such as raditors, heat registers, stoves, etc.
This device should be situated so that its location or position does not interfere with its proper ventilation.
Care and Maintenance
Your PYLE PRO mixer is an example of superior design and craftsmanship. The following suggestions will help you care for your mixer so you can enjoy years of use:
• Keep the mixer dry, if it gets wet, wipe immediately.
• Use the mixer only in well ventilated installations.
• Handle the mixer gently and carefully-do not drop.
• Keep the mixer away from dust and dirt.
• Wipe occasionally with a damp cloth to keep it looking new. Do not use harsh chemicals, solvents or detergents.
Pyle Pro Mixer PYD6070/1270 Owner’s Manual – 1
Features and Controls: PYD6070 Mixer
MIC1 & MIC2 Balanced XLR Input Connector
For connecting a balanced low impedance microphone with XLR type plug.
EFX SEND/RETURN Jacks
Permit you to either include externally generated effects (such as a digital sampler or synth) IN the mix, or to process the mixed sound (echo reverb, etc.).
LINE 1 & LINE 2 BAL or UNBAL 1/4" (TRS) Input Jack
For connecting a balanced or unbalanced line level sources.
MIC1/LINE 1 & MIC2/LINE 2 GAIN Control
Lets you adjust the gain of the input source.
CH1, CH2, CH3/4, & CH5/6 Tone Controls (EQ)
CH1, CH2, CH3/4, & CH5/6 EFX Control
Lets you adjust the channel signal level sent to the external effect.
CH1 & CH2 PAN Control
Lets you adjust the channel signal level feeding the L & R mix bus.
CH1 & CH2 PEAK Indicator
Indicates the channel signal is going into overload.
HEADPHONES Jack
Accepts the headphones with 1/4" plug.
CTRL ROOM OUT Jacks
To connect the mixer to a second receiver or amplifier powering speakers in the control room or in a remote location.
POWER ON Indicator
MAIN OUT Jacks
To connect the mixer to a receiver or amplifier.
LINE 3/4 & LINE 5/6 BAL or UNBAL 1/4" (TRS) Input Jacks
For connecting a balanced or unbalanced stereo line level sources. Use LEFT input jack only for each channel, if the source signal is mono.
TAPE IN & OUT Jacks
To connect the mixer to a tape deck for recording the mixed program and for auditioning mix playback from tape.
TAPE TO MIX Switch
Press to route the signal playback from tape to the MAIN mix bus.
DUAL LED DISPLAY METER
Indicates the levels of left and right MAIN outputs.
PHANTOM +48V DC Switch with Indicator
Press to accept the use of condenser microphones.
CH1, CH2, CH3/4, & CH5/6 LEVEL Control
Lets you adjust the channel signal level sent to the MAIN mix bus.
CH3/4 & CH5/6 BAL Control
Lets you adjust the channel signal levels of left and right relative to each other before both signals are then sent to the MAIN mix bus. It allows you to balance the source in the stereo image.
2 – Pyle Pro Mixer PYD6070/1270 Owner’s Manual
MASTER Level Control
Lets you adjust the signal level of MAIN and TAPE outputs.
EFX RETURN Level Control
Lets you adjust the effects signal level sent to the MIAN mix bus.
CONTROL ROOM/PHONES Level Control
Lets you adjust the signal level sent to the control room and headphones.
TAPE TO CONTROL ROOM Switch
Press to route the signal playback from tape to the control room.
Features and Controls: PYD1270 Mixer
EFX SEND/RETURN (LINE 11/12 Input) Jacks
Permit you to either include externally generated effects (such as a digital sampler or synth) IN the mix, or to process the mixed sound (echo reverb, etc.). Use two 1/4" (TRS) jacks of LINE 11/12 as effect return path, turn the EFX GAIN of CH 11/12 fully down to avoid undesirable feedback.
LINE 5/6, LINE 7/8, LINE 9/10, & LINE 11/12 BAL or UNBAL 1/4" (TRS) Input Jacks
For connecting a balanced or unbalanced stereo line level sources. Use LEFT input jack only for each channel, if the source signal is mono.
CONTROL ROOM/PHONES Level Control
Lets you adjust the signal level sent to the control room and headphones.
TAPE TO CONTROL ROOM Switch
Press to route the signal playback from tape to the control room.
CH5/6, CH7/8, CH9/10, & CH11/12 BAL Control
Lets you adjust the channel signal levels of left and right relative to each other before both signals are then sent to the MAIN mix bus. It allows you to balance the source in the stereo image.
MIC1/LINE 1, MIC2/LINE 2, MIC3/LINE 3, & MIC4/LINE 4 GAIN Control
Lets you adjust the gain of the input source.
CH1, CH2, CH3, & CH4 Tone Controls (EQ)
CH1, CH2, CH3, CH4, CH5/6, CH7/8, CH9/10, & CH11/12 EFX Control
Lets you adjust the channel signal level sent to the external effect.
LINE 1, LINE 2, LINE 3, & LINE 4 BAL or UNBAL 1/4" (TRS) Input Jack
For connecting a balanced or unbalanced line level sources.
MIC1/MIC2/MIC3 & MIC4 Balanced XLR Input Connector
For connecting a balanced low impedance microphone with XLR type plug.
CH1, CH2, CH3, & CH4 PEAK Indicator
Indicates the channel signal is going into overload.
CH1, CH2, CH3, & CH4 LO CUT Switch
Press to eliminate unwanted low-frequency signal components.
CH1, CH2, CH3, CH4, CH5/6, CH7/8, CH9/10, & CH11/12 LEVEL Control
Lets you adjust the channel signal level sent to the MAIN mix bus.
CH1, CH2, CH3, & CH4 PAN Control
Lets you adjust the channel signal level feeding theL&Rmixbus.
CH5/6, CH7/8, CH9/10, & CH11/12 GAIN Switch
Press to increase the channel gain by +12dB.
CTRL ROOM OUT Jacks
To connect the mixer to a second receiver or amplifier powering speakers in the control room or in a remote location.
HEADPHONES Jack
Accepts the headphones with 1/4" plug.
POWER ON Indicator
MAIN OUT Jacks
To connect the mixer to a receiver or amplifier.
TAPE IN & OUT Jacks
To connect the mixer to a tape deck for recording the mixed program and for auditioning mix playback from tape.
TAPE TO MIX Switch
Press to route the signal playback from tape to the MAIN mix bus.
EFX TO CONTROL ROOM Switch
Press to route the EFX SEND signal to the control room.
DUAL LED DISPLAY METER
Indicates the levels of left and right MAIN outputs.
PHANTOM +48V DC Switch with Indicator
Press to accept the use of condenser microphones.
MASTER Level Control
Lets you adjust the signal level of MAIN and TAPE outputs.
EFX SEND Level Control
Lets you adjust the EFFECTS signal level sent to the EFX SEND.
Pyle Pro Mixer PYD6070/1270 Owner’s Manual – 3
INSTALLATION, PYD6070 Mixers
4 – Pyle Pro Mixer PYD6070/1270 Owner’s Manual
INSTALLATION, PYD1270 Mixers
Pyle Pro Mixer PYD6070/1270 Owner’s Manual – 5
Mono Input Channel Controls
CH1/CH2 For PYD6070 CH1/CH2/CH3/CH4 For PYD1270
MIC
Each mono input channel comes with an XLR balanced microphone input connector and also offers a +48V PHANTOM switch to supply power for condenser microphones. Please mute the playback/PA loudspeakers system before switching on +48V PHANTOM power to prevent the switch­on thumps being directed to the loudspeakers. Please connect the microphones before switching on the +48V PHANTOM power supply, do not connect microphones to the mixer as long as the phantom power supply is switched on. Wait for approximately one minute to get the system stabilized.
LINE
Each mono input channel comes with a balanced 1/4" (TRS) line level input jack. The unbalanced devices can also be connected to this input.
NOTE
Please use only either the MIC or LINE input of a channel at any one time, do not use both simultaneously.
GAIN
This rotary GAIN control adjusts the channel input gain level. Proper gain setting gives the mixer to work in the best operating level. Please turn it to 0 completely whenever you connect or disconnect a signal source to one of the inputs.
EQ (HI/MID/LO)
ALL the mono input channels has a 3-band equalizer, all bands provide up to 15dB of cut and boost, with a centre detent for OFF. The cut-off frequencies of HI and LO band are 10 kHz and 100 Hz respectively. The MID band is configured as a peak filter with a center frequency at 1 kHz .
EFX
It enable you to feed channel signal to the external effect.
PAN
It determines the amount of the channel signal feeding the left and right mix bus, to locate the source smoothly across the stereo image. Its constant-power design ensure the signal is always maintained at a constant level.
PEAK
It illuminates to warm you the input channel signal is driven too high, which could cause distortion. Use the GAIN control to adjust until the LED does not light.
LEVEL
It determines the level of channel signal in the MAIN mix bus and provides a clear visual indication of channel level.
LO CUT (PYD1270)
It is a steep LO CUT filter designed to eliminate unwanted low frequency hum. It is useful on live vocals to reduce stage rumble or "popping" noise from microphone.
6 – Pyle Pro Mixer PYD6070/1270 Owner’s Manual
Stereo Input Channel Controls
CH3/4 & CH5/6 For PYD6070
LINE, LEFT & RIGHT
Each stereo input channel comes with two balanced 1/4" (TRS) line level input jacks. The unbalanced devices can also be connected to this input. If only the jack marked "LEFT" is used, the channel operate in mono. The stereo channels are designed to handle typical line level signals.
EQ (PYD6070)
It is similar to those of the mono channels, except that the EQ is stereo. It is preferable of using two mono equalizer when EQ-ing a stereo signal to avoid the discrepancies occurred oftenly between left and right setting.
EFX
It is similar to those of the mono channels, except that the EFX SEND buses are both mono, a mono sum is first taken from the stereo input before it is sent to the EFX bus.
CH5/6, CH7/8, CH9/10 & CH11/12 For PYD1270
BAL
It determines the level of left and right input signals relative to each other before both signals are then routed to the MAIN stereo mix bus, allows you to balance the source in the stereo image. If a stereo channel is run in mono (only the left input connected), the balance control acts as a pan in the normal way.
LEVEL
It determines the level of channel signal in the MAIN mix bus and provides a clear visual indication of channel level.
GAIN (PYD1270)
It is an input sensitivity switch which used to select between +12dB (press on) for studio level and 0dB (press off) for home-recording level.
Pyle Pro Mixer PYD6070/1270 Owner’s Manual – 7
Main Section Connections and Controls
PYD6070 PYD1270
EFX SEND Jack
It is a 1/4" unbalanced jack sends out the signals from mix bus to the external effects unit.
EFX RETURN Jacks/Control (PYD6070)
The EFX RETURN Jacks bring the output of the external effects unit back into the mixer. These jacks can be used instead as additional line level inputs, but any external effects signal will have to be brought back into the mixer via a normal stereo channel, it does allow you to use the channel EQ on the effects return signal. When a normal stereo channel is used as effects return path, the EFX control of the relevant channel should be turned fully down to
avoid undesirable feedback. If only the LEFT jack is used, the EFX RETURN is operated in MONO mode. Use the EFX RETURN rotary control to adjust the effects signal levelsent to the MAIN mix bus. NOTE:PYD1270 uses two 1/4" (TRS) jacks of LINE 11/12 as EFX RETURN, turn the EFX GAIN of CH 11/12 fully down to avoid undesirable feedback when using this path.
PHONES/CTRL ROOM OUT Jacks
The stereo PHONES jack sends the mix signals to the headphones. The two unbalanced CTRL ROOM OUT jacks carry the summed effects, main mix signals, and soloed channel signals to the control room speakers.
POWER ON Indicator
The large size LED indicator illuminated when the mixer power is on.
MAIN OUT Jacks
The MAIN OUT jacks send line level signals from mixer to external devices, for examples, equalizer or power amplifier.
8 – Pyle Pro Mixer PYD6070/1270 Owner’s Manual
TAPE IN Jacks
The TAPE IN jacks are used to bring the external signal source (Tape Recorder or CD Player) into the mixer. Like the EFX RETURN jacks, they also can be used as a standard stereo line level input, in other words, the line or tape output of an power amplifier with source selection switch can also be connected here for you to listen to additional source.
TAPE OUT Jacks
The TAPE OUT jacks are used send the MAIN mix signal to your recording device. The output level is adjusted by the MASTER level control.
TAPE TO CONTROL ROOM Switch
Press this switch to monitor signals coming back from tape recorder (TAPE IN) to ensure that they are recording correctly. Do not use the TAPE TO MIX switch doing this to avoid the feedback loop.
TAPE TO MIX Switch
Press this switch to route the signals from TAPE IN to the MAIN mix.
EFX TO CONTROL ROOM Switch (PYD1270)
Press this switch to monitor the EFX SEND signal in the control room or headphone. The MAIN mix signal will be muted while routing the EFX SEND signal to the control room.
EFX SEND Control (PYD1270)
Use it to adjust the overall EFX SEND signal level.
PHANTOM Switch/LED Indicator
Press to activate +48V DC power supply on the MIC XLR connectors of all mono channels. The red LED lights when phantom power is on.
DUAL LED DISPLAY METER
A pair of 5-segment bargraph peak meters displays the MAIN mix level LEFT and RIGHT.
PHONE/CONTROL ROOM Control
Use it to adjust the level of both headphones and main monitor outputs.
MASTER control
Use it to adjust the MAIN mix signal level.
Pyle Pro Mixer PYD6070/1270 Owner’s Manual – 9
Specifications
MONO INPUT CHANNELS
Mic Input electronically balanced
Sensitivity/Impedance ..............................................1.5 mV/600 Ohms
Frequency Response .................................................20 Hz to 20 kHz, +/- 3dB
Distortion ................................................................0.2%, 1 kHz/1.5 mV input
S/N Ratio ................................................................60 dB (with A-WTD)
Line Input electronically balanced
Frequency Response. ................................................20 Hz to 20 kHz, +/- 3dB
Distortion ................................................................0.03%, 1 kHz/150 mV input
Equalization
HI shelving ..............................................................10 kHz, +/- 15 dB
Mid Range ...............................................................1 kHz, +/- 15 dB
Lo Shelving .............................................................100 Hz, +/- 15 dB
STEREO INPUTS CHANNELS
Line Input balanced
Frequency Response .................................................20 Hz to 20 kHz, +/- 3dB
Distortion ................................................................0.03%, 1 kHz/150 mV input
Equalization
HI shelving ..............................................................10 kHz, +/- 15 dB
Mid Range ...............................................................1 kHz, +/- 15 dB
Lo Shelving .............................................................100 Hz, +/- 15 dB
MAIN MIX SECTION
Max Output .............................................................2V unbalanced
EFX Send Max Out....................................................2V unbalanced
Control Room Out.....................................................2V unbalanced
Signal to Noise Ratio.................................................80 dB (with A-WTD)
POWER SOURCE.......................................................AC 15V
DIMENSIONS (WxHxDmm): ..................................PYD6070 213x40x226
.............................................................................PYD1270 270x40x226
10 – Pyle Pro Mixer PYD6070/1270 Owner’s Manual
Pyle Pro Mixer PYD6070/1270 –11 Owner’s Manual
Please complete warranty card, detach and return
Place
Stamp
Here
PYLE PRO Audio, Inc. 1600 63rd Street Brooklyn, NY 11204
Limited Warranty
All PYLE PRO products are carefully constructed and tested before shipment. Units purchased in the USA are warranted to be free of defects in material and workmanship for two (2) years from the date of purchase. This warranty is limited to the original retail purchaser of the mixer.
Should the unit fail due to factory defects in material or workmanship, your unit will be repaired or replaced at the sole discretion of PYLE.
To obtain warranty service, you must first call our Consumer Return Hotline at (718) 236-6948 to obtain a Return Authorization Number. This R.A. # must appear on the outside of your package and on all paperwork relating to your return.
When returning the unit to us for warranty service, it must be carefully packed and shipped, prepaid, to:
Please complete warranty card, detach and return
Thank you for purchasing this PYLE product. To activate your warranty, please mail this card within 10 days.
warranty registration card
PYLE PRO MIXERS
Name
R.A.#: _____________ PYLE PRO Service Center 1600 63rd Street
You must also include the following items with your return:
• A copy of your sales receipt or other proof of purchase
• A brief letter, indicating the problem you are experiencing with the product
• Include in your letter your return address, daytime phone number and R.A. number
• Also include a check or money order for $20.00 for return
shipping, handling and insurance, or provide your Visa/MC number with expiration date.
Our obligation under this warranty is limited to the repair or replacement of the defective unit when it is returned to us prepaid. This warranty will be considered void if the unit was tampered with, improperly serviced or subject to misuse, neglect or accidental damage.
Brooklyn, NY 11204
Address
City, State ZIP
Model No. Serial #
Date of Purchase
Purchased at:
Music Products Store
Catalog Merchandiser
Sound Contractor/Installer Mail Order
Other
(if available)
www.pyleaudio.com
12 – Pyle Pro Mixer PYD6070/1270
Owner’s Manual
Loading...