Model
2 OH M S
PQA2100
1050+1050w rms 460+460w 230+230w 920+920w
>85dB
>70dB
>250
30v/μs
Short circui t,C urrent lim iter, T ermal cut off ,Slo w Star t, Limiter,AC li ne fus e, DC fault,Power u p/do wn tra nsients
<140W
PQA3100
1550+1550w rms 760+760w 380+380w 1520+1520w
10Hz-50KHz -1.5dB
21dB/9V
20K OHMS
>85dB
>70dB >70dB
>250
h
30v/μs
Variab le Speed Fan
<300W
AC 115V- 230V/ 50- 60H z
PQA4100
2050+2050w rms 1000+1000w 500+500w 2000+2000w
>90dB
>250
30v/μs
<300W
PQA5100
2550+2550w rms 1200+1200w 600+600w 2400+2400w
>90dB
>70dB
>250
30v/μs
<300W
OVERVIEW
It is well- known the PQA series professional amplifier is designed by the specialist who has full experience and new model equipment. To raise reliability of the amplifier, PQA series professional amplifier has been installed with short distance cooling unit, high- speeding and consistency to increase the life of the power parts.They all have adopted mature and reliable circuit with SMT technology.
The conventional amplifier applies tunnel- model cooling system, this kind of system has long distance for heat dissipation, the hot air is distributed with difficulty, and theradiator is very hot at the top, but too cool at the bottom, the temperature difference goes between 2 0℃-4 0℃,those system produces temperature difference easily in the power parts, the electric current is high in hot parts, which results in its damage and reduces the using- life and reliability.
PQA series amplifiers has full-protection, including:
Soft start function to prevent wave shock at power- on. Delay function for prevent shock at switch power on. DC protection. Over- electric current protection. Cut- wave protection. Over heat protection.
482x 314 x88 mm
8kg
9.5k g
10.5 kg
11.5k g
Installation guidelines
DO NOT use these amplifiers in damp or high humidity environments.
Do not use outdoors or anywhere where liquids could fall or splash onto the amplifier.
Ensure the amp is adequately ventilated, with free airflow to the front and rear panels.
Keep away from other heat sources. If the amps are mounted in a rack with other amps, ensure there is adequate cool air flow front and rear. Note that air is drawn in through the back panel, and exhausted through the front panel.
NEVER cover the amplifiers, as they may overheat.
PQA power amplifiers are designed to fit standard 19 racks, with a 2U height
and 17 depth. We recommend the use of rear rack supports, especially if the rack is to be mobile. Use shake proof washers or thread lock adhesive to prevent mounting bolts becoming loose in transit.
Ensure that the AC power supply is correct for your amplifier. The required AC supply
is stated on the rear panel next to the AC power input.
ATTENTION
Never put any parts on the top of the amplifier. Using fixed power socket that must be has enough capacity to prove power. Never switch the power on and off continuously at the same time. Donruction in the air vent of front panel. Input stereo level can be adjust by own gain mixer, in bridge- model connection, the adjustment will adjust by CHA channel mixer. The output connector have 3 kind model, tie- model, phone model and professional speakon connector for connecting. When using stereo, bridge, mono function, the connect model must be same than model switch selected. When output high- power signal continuously, the amplifier should be has speed­up in the cooling fan, it may be have low noise produce in this equipment, it is normally. The general gain of the amplifier can be adjust by gain knob, the input level have 0 .7 7V, 1 .4 V, full- power out and fixed 2 6dB gain 3 band should be selected. Donr vent of rear panel. When clear-up the cover of the equipment, you must be power off and loose the power Plug using dry- cloth to clear, never using and solvent that have corrosive to clear. If have problem happened, power down immediately, and contact with dealer.
Ensure that you use the correct type of mains lead for your equipment and country.
This must be free from damage and easily accessible during use.
www.pyleaudio.com
www.pyleaudio.com
Des
Des
PQA
g
n
n
e
e
d
d
n
n
a
a
d
d
e
e
n
n
g
g
i
i
n
g
g
i
i
s
s
e
e
D
D
n
d e
d e
n
n
d a
d a
e
e
n
d i
e
er
er
e
e
in
in
g
g
n
A
A
S.
S.
.
.
n U
n U
d i
e
PQA
S.A
S.A
.
.
U
U
n
n
i
i
ed
ed
r
r
e
e
e
e
n
n
i
i
g
Rear Panel
8
MODE
ST BR
B
2
2
6
6
7
4
5
3
4
3
1
www.pyleaudio.com
8. Bridge mode(PQA2100 doest have bridge mode) As the work is bridge mode, CH A output+connector is the Bridge connector +; while CH B+ connector is the Bridge connector -.
www.pyleaudio.com
PQA
FAULT
No sound (power LED off)
NO sound (Power LED on)
Hum or buzz is audible
Distortion is audible
Sound cuts out or is I ntermittent
PROBLEM SOLUTIONS
AC supply not connected or switched off
Blown fuse
No input, or input too low
Level controls set too low
Speakers faulty or not connected
Noise from AC supply is being picked up in the signal path
There is an earth problem
Excessive signal level somewhere in signal chain.
Damaged or poor quality cables
Damaged or poo r quality cables or conn ectors, connectors n ot pro perly inserted, am p overheating
Check AC connections and switches
Check and replace fuses at plug and IEC socket. USE ONLY SAME TYPE AND RATING!
Check input is connected, and LED
Increase level controls
Check speakers and speaker connections
Use good quali ty, sh ielded sign al cab les and ensure they ar e kept away from AC powe r cabl es and other AC powe red equipment
Use a mains test er to en sure the AC outl et has a good earth . Power connected e quip ment(e.g mixer and amp) from th e same AC outlet where p ossi ble.
Use the LED to ens ure th e AC outlet has a go od ear th. Power connec ted equipment fro m the sa me AC outlet where possib le
Use only high qu ality cables of the a ppro priate type, protect them f rom da mage and regu larl y check connec tions.
Check all cabl es and connection s, ref er to above sections reg arding distorti on and t emp warning light
Service
All the products are thoroughly examined and tested before leaving the factory, and if used correctly will give you many years of excellent service. However, if a problem arises, proceed as follows: (A) contact the retailer from whom the unit was purchased and describe the symptoms of the fault. (B) if the retailer cannot help, return the equipment to the national distributor for your country. Use the original packaging to protect the product from damage. Include a note with the equipment stating your name and address, details of the problems, date code and date and place of purchase.
www.pyleaudio.com
Page5
Loading...