PW maintenance DT-TS, DT-NTS Operating Instructions Manual

Operating Instructions
Model: DT-TS / DT-NTS
06/08 Revision 1
Ref: TS6
Contents Page
Display Symbols Explained 2
Temperature Display 6
Locking the Keypad 7
Heat On/Off 8
Clean Screen 8
Factory Reset 9
Optional Feature Setup 10-13
Wiring Diagrams 14-18
Display Symbols Explained
Symbol Description
Heat On Icon
Shown when the heating is On
Frost On Icon (Heating Off) Shown when the heating is switched off and is
protecting against frost only
Keylock Icon
Shown when the keypad is locked
What is a room thermostat?
A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of the boiler and radiators.
Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy. The heating system will not work if a time switch or programmer has switched it off.
The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this
is to set the room thermostat to a low temperature - say 18ºC - and then turn it up by 1ºC each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs.
Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly.
Installation Procedure
DO’s
1. Do mount the thermostat at eye level.
2. Do read the instructions fully so that you get the best from our product.
DON’Ts
1. Do not install near a direct heat source as this will affect the workings of the thermostat.
2. Do not push hard on the LCD otherwise you will damage the liquid crystal display and this is not repairable.
Installation
The thermostat is designed to be flush mount, a back box of 35mm should have been sunk in the wall prior to installation.
Step 1 Carefully separate the front half of the thermostat from the back plate by placing a small flat head terminal driver in to the slots on the bottom face of the thermostat.
Step 2 Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat.
Place the thermostat front half somewhere safe. Terminate the thermostat as shown in the diagrams at the back of this booklet.
Screw the thermostat back plate on to the back box
Step 3 Re-connect the thermostat ribbon cable and clip the two halves together.
Temperature Display
Room Temp = This is the current room temperature.
SET = This is the temperature you are trying to achieve in
your home.
Locking the Keypad
The thermostat has a keylock facility. To enable this press the bottom right corner of the display and hold for 10 seconds
When activated, you will see . To cancel, repeat the steps above.
Temperature Set
Using the keys allows you to adjust the set temperature. When you press either of these keys, you will see the word SET and the desired temperature.
Press Done to accept.
Heat On / Off
Frost Protect Mode: Pressing the Off button once will
place the thermostat in frost protect mode. In this mode, the thermostat will display the frost icon and will only turn the heating on should the room temperature drop below the set frost temperature (see pages 10-13). Should the heating be turned on whilst in frost mode, the flame symbol will be displayed. To cancel the frost protect mode, press the On button.
Thermostat Off: To turn the thermostat off completely, press and hold the Off button. The display and heating output will be turned off. To turn the thermostat back on, press the On button.
Clean Screen
Pressing Clean Screen will disable all buttons, allowing you 30 seconds to wipe the screen clean.
Factory Reset
The thermostat has a factory reset function. This will reset all settings back to their factory default.
To perform a factory reset, follow these steps:
Turn off the thermostat by pressing the off button. Press and hold the bottom left corner of the LCD for 10 seconds. You will see all the icons appear for 2 seconds and then disappear. The thermostat has then been reset to the factory defaults.
10
THE FOLLOWING SETTINGS ARE OPTIONAL
AND IN MOST CASES NEED NOT BE ADJUSTED
Optional Features Explained
Feature 01 – Temperature Format: This function allows
you to select between °C or °F.
Feature 02 - Switching Differential: This function allows you to increase the switching differential of the thermostat. The default is 1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1.5°C below the set temperature and will switch off 0.5°C above the set temperature.
Feature 03 - Frost Protect: You can set whether the thermostat will maintain the frost temperature when the thermostat display is turned off. As a default, this is enabled.
11
Feature 04 - Frost Protect Temperature: This is the temperature maintained when the thermostat is in frost mode. The range is 07-17°C. The default is 12°C and is suitable for almost all applications.
Feature 05 - Output Delay: To prevent rapid switching, an output delay can be entered. This can be set from 00-15 minutes. The default is 00 which means there is no delay.
Feature 06 - Communication Address: This setting is used when you have connected your thermostat to a network system. Each thermostat on the network must have a unique communication address. This can be set from 01-32.
Feature 07 - Temperature Up/Down Limit: This function allows you to limit the use of the up and down temperature arrow keys. This limit is also applicable when the thermostat is locked and so allows you to give others limited control over the heating system.
12
Adjusting the Optional Settings
To adjust the settings, follow these steps:
• With the thermostat turned on
• Press PROG
• Press SETUP
• Use the at the top of the screen to select the feature number (shown on page xx) and then use the
keys in the centre
adjust the setting.
• Press Done to accept and Store
13
Feature Table
Feature Description Setting
01 °C / °F Temperature Format
02 Switching 01=1°C 02=2°C 03=3°C Differential 1°C = Default
03 Frost Protect 00 = Disabled 01=Enabled (01=Default)
04 Frost Temp 07-17°C (12=Default)
05 Output Delay Enter value 00-15 minutes (00=Default)
06 Comms # Enter number 01-32
07 Temp Limit 00 - 10°C
14
Heatmiser DT-TS Model
15
Heatmiser DT-TS Model
16
Heatmiser DT-TS Model
17
Heatmiser DT-NTS Model
18
Heatmiser DT-NTS Model
Support Tel: 01254 870303
®