LOW NOx TURBOPOWER® • PACKAGED WATER HEATER
NICKELSHIELD® NICKEL-PLATED STORAGE TANK
TANK SERIES 750 GALLONS VERTICAL
MODEL
NUMBER
500 N 750A-TPL 500 400 399,000 4.5 4TPL 399 MBtu/h 28 5 3/4 16 1/3 8 2660
c Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss.
d “J” dimension is for the burner housing only – gas train may exceed this dimension.
e Standard gas train.
* The information presented is for natural gas 0.6 S.G.
Dimensions are in inches unless otherwise specified.
For standard and optional equipment, see form #PV6540.
Recovery gph
40° - 120°F 40° - 140°F A B C J d HP Amps
c
INPUT
Btu/h
Min. Inlet
Flow Gas
Pressure
" W.C. e
SCAQMD Energy
Model No.
Dimensions (inches)
Blower
Motor
Shipping
Weight
lbs
STANDARD GAS PRESSURE REQUIREMENTS:
SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER.
MAXIMUM STATIC INLET GAS PRESSURE IS 14" W.C.
FOR GAS PRESSURES OUTSIDE OF THIS RANGE,
CONTACT YOUR PVI REPRESENTATIVE.
VENTING REQUIREMENTS:
-.02" TO -.06" W.C. (NEGATIVE PRESSURE).
TYPE B VENTING.
ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON
THE VENT CONNECTION DIAMETER EXCLUSIVELY. CHECK
NATIONAL FUEL GAS CODE UNDER "FAN ASSISTED."
CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS.
MOTOR VOLTAGE: 1/3 HP ARE 120V, 1Ø, 60 HZ.
208V, 230V AND 460V MOTORS ARE AVAILABLE BUT WILL
REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN
OPTIONAL CONTROL CIRCUIT TRANSFORMER.
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND
PVI INDUSTRIES, LLC
FORT WORTH, TEXAS 76111
PV 6549 11/07 (800) 784-8326 • www.pvi.com
STANDARD ELECTRICAL REQUIREMENTS:
SPECIFICATION WITHOUT NOTICE.
Product is patented in the U.S., Canada, and Mexico.