PVI Industries 27 P 125A-MXS, 40 P 125A-MXS, 20 P 125A-MXS User Manual

LOW NOx MAXIM • PACKAGED GAS WATER HEATER
POLYSHIELD® POLYMER-LINED STORAGE TANK
125 GALLON TANK SERIES
MODEL NUMBER
Minimum gas inlet pressure – " W.C. 5.5 5.5 5.5 A Cold Inlet - NPT 2 2 2 B Hot Outlet - NPT 2 2 2 C Drain - NPT 1 1 1 D I - Beam Skids 3 X 34-1/2 3 x 34-1/2 3 x 34-1/2 E Overall Depth 45 45 45 F Overall Height 75 75 82 G Flue Outlet Diameter 5 6 7 H Gas Inlet - NPT 1/2 3/4 3/4 J Motor HP 120 V, 1Ø, 60 Hz. 1/6 1/6 1/6
Motor Amps 1.75 1.75 1.75 L Height to Outlet 65 65 73 M Height to Inlet 28 28 36
Approx. Shipping Weight - lbs 1020 1070 1130
Recoveries based on 82% thermal efficiency. ASHRAE 90.1 compliant. Dimensions are in inches unless otherwise specified. For standard and optional equipment, see Form # PV6377.
20 P 125A-MXS 27 P 125A-MXS 40 P 125A-MXS
1. Control Enclosure
2. ASME Temperature & Pressure Relief Valve
3. 3” NPT Handhole
STANDARD GAS PRESSURE REQUIREMENTS:
SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER.
MAXIMUM STATIC PRESSURE: 9" W.C.
FOR GAS PRESSURES OUTSIDE OF THIS RANGE,
CONTACT YOUR PVI REPRESENTATIVE.
STANDARD ELECTRICAL REQUIREMENTS:
CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS
THE ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE
FOR PROPER VENT SIZING, CONSULT THE NATIONAL FUEL GAS CODE
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND
PVI INDUSTRIES, LLC
FORT WORTH, TEXAS 76111
PV 6378 02/05 (800) 784-8326 www.pvi.com
VENTING REQUIREMENTS:
-.02" TO -.06" W.C. (NEGATIVE PRESSURE). TYPE B VENTING.
VENT CONNECTION DIAMETER EXCLUSIVELY.
UNDER "FAN-ASSISTED".
SPECIFICATION WITHOUT NOTICE.
Product is patented in the U.S., Canada, and Mexico.
Loading...