PureWater 200 GPD, 400 GPD, 500 GPD, 600 GPD, 800 GPD Mounting Instruction, User And Maintenance Handbook

...
Mounting-instruction, User - and maintenance-handbook
For the series NO FRILLS modular COMFORT, 230 Volts 50 Hz
PureWater. H. Fehlemann - Desalination
Your Freshwater-Source
We are happy that you decided in favor of one of our reversion-osmosis-installation (RO unite) and you greet in the growing circle of the users of desalination-installations.
We will do everything in order to satisfy you also after your purchase. This handbook contains, exact instructions, as you fit in your installation, use it and keep it
maintained. If you should have further questions in addition, you don't hesitate to call us.
In order to gain an optimal performance and a long lifespan of your installation, you read alertly through this handbook before the mounting; if you should require further help, you let it know us.
PureWater – Desalination
Index of contents
System-bases........................................................................................ 1
Performance data............................................................................. 2
Membrane-Performance......................................................................... 2
Electric connection-values...................................................................... 3 .
Pressure regulation................................................................................... 4
Before mounting. .................................................................................... 5
Description of the individual parts. ......................................................... 6-7
Mounting the pressure vessels. ................................................................. 8
Motor and pump. ..................................................................................... 9
Factors affecting Temperature and
Pressure......................................................................................... 10
Flow-diagram. ........................................................................................ 12
Pressure Regulator................................................................................... 13
Electrical installation............................................................................... 14
Starting the System................................................................................. 15-16
Maintenance....................................................................................... 16
How to Flush................................................................ 17
Cleaning............................................................................................... 18
Storage............................................................................................... 19
Membrane Change.....................................................................................20+20a
Manufactures Literature............................................................................. 21-23
Logbook..................................................................................................... 24
Quality Monitor…………………………………………………………………. 25 John Guest System…………………………………………………………… 26 Wiring ………………………………………………………………………….. 27
NO FRILLS 500/800 Guide
System-bases
Introduction into the reversion - osmosis
Reverse-osmosis is a process, with which a membrane divides one water-flow in two water flows. One part is fresh-water and amounts about 7-10 percent of the entire water-quantity, the other flow is concentrated saltwater, which is washed away. Since saltwater is a solution of H²O and different solved materials (salt), the membrane acts like a filter. In order to be able to remove these solved materials from the water, the pores of the membrane must be smaller than the solved materials that should be taken away. The pores of a membrane are so small that they can be seen only by one electron microscope. (0,0001 micron), that means, that the sea-water must be pressed through the membrane. This pressure must have the strength of 800 Psi (56 bar) approximately. How high the current pressure must be exact, is a result from the water-temperature and the salt content of the water.
This temperature / pressure-relationship later will be explained later in this handbook. See chapters: Temperature - Pressure - Correction. As you know, each filter can become blocked or damaged. A reverse-osmosis-membrane is
no exception. Your System is designed that surplus particles are rinsed with the Brine flow. Nevertheless, there are conditions, which contaminates, blocked or damage the membrane.
With regular maintenance, as it is described in this handbook, the possibility of a failure of a membrane can be minimized and costly substitute be avoided. Regular maintenance is comparatively affordable, gets the effectiveness and extends the lifespan of the installations.
1
NO FRILLS 500/800 Handbook
Performance Data
Membrane-performance* Model gallons per hour liter per hour
200 GPD 8,30 GPH 31,41 LPS 400 GPD 16.60 GPH 62,83 LPS 500 GPD 20,80 GPH 78,20 LPS
600 GPD 25,00 GPH 94,50 LPS 800 GPD 38,00 GPH 145,00 LPS 1000 GPD 52,90 GPH 200,00 LPS
1300 GPD 54,20 GPH 205,14 LPS 1800 GPD 75,00 GPH 283,81 LPS 2000 GPD 83,33 GPH 315,40 LPS 3000 GPD 125,00 GPH 473,12 LPS
Salt-Rejection = Minim. 99,2% Water-quality = above WHO standard
Sea-water-temperature, pressure and salt content have strong influence on the performance and quality of the product-water. Details you find in the chapter Operation.
Test-conditions Pressure 800 PSI
Sea-water-temperature 25° C Salinity 35,000 PPM (parts of million))
Pump-performance
Operating-pressure 700 - 1000 PSI Total flow 200-800 GPD systems 2.90 GPM 1000-1800 GPD systems 3.7/4.76 GPM
2
NO FRILLS 500/800 guides
Electric connection-values 230-volt SERIES Ampere KILOWATT
NO FRILLS 500/600 GPD 9,5 1,5 NO FRILLS 800/900 GPD 9,5 1,5 NO FRILLS 1000-1800 GPD 16 1,85/2,2
Electric wiring
The connection should be carried out by a qualified electrician.
Control box inside:
Motor connection for CAT Pumps
See attached CD. For Identification of the wires at the pump, we left a short piece of wire out of the box at the motor. However, you are free to connect the wires inside the box. The build in switch is not needed. If you leave the switch, make sure, it is in the ON position. The connection schematic is inside the cup of the box.
Electrical connections should be done by a qualified electrician. Cable Identification: NO 1 = L - brown NO 2= N – blue, yellow – green is GND
3
Power relay
Fuse 2A for LP Pump
Test Button – pull Reset Button Motor protection relay
NO FRILLS 500/800 Guides
The NO FRILLS 500/800 modular COMFORT is delivered in following implementation.
Motor and HP Pump Main Controlpanel Pressure Vessel and Membrane NF 500
Fresh Water flush system Pre-Filter and PH Stabilizer LP Pump
Pressure Regulation and Flow distribution
Pump switches Flush Button (Option)
Quality Monitor
4
Pressure indicator
High Pressure Bypass Valve Position: No pressure, cleaning flushing
CLEANING VALVE: Position: NORMAL FLOW: for desalination and flushing. Brine Flow over board.
Position: CLEANING: for cleaning and preservation. The flow is returned to the “T” at the pre filter. See flow diagram.
NO FRILLS 500/800 Guides
Before mounting!!
Please pay attention to the following points before you fit in your NO FRILLS installation and take in operation!
1. The installation should be taken in operation within 12 months after delivery
2. The installation should about every 7 days, in very hot areas, every 3 days, operated with sea water or flushed with fresh-water.
3. If the installation is for a long time out of order, it should at the latest after 12 months flushed and preserved again.
4. Never operate the system in harbors or in areas where fuel and oil is in the sea-water.
5. If you use the system in fresh - or brackish water, the operating-pressure must be adjusted, that the output of fresh water is within the operating limits.
6. Protect the installation from freezing.
7. Don't let the membrane dry out. If you take out the membrane for any reason, it has to be sealed immediately.
8. The sea-water- inlet must be shaped so that the sea-water is pressed in during cruise.
Attention!!
The quantity of the produced drinking water is very strong dependent on the temperature of the sea-water. All accomplishment-statements are based on a temperature of the sea-water of 25°C. Per 1°C below 25°C, the production loses 3 percent of performance.
As well, the salinity of the sea water is a factor. Higher salinity, lower performance.
5
NO FRILLS 500/800 Guide The general scopes of the NO FRILLS desalination-installations
The NO FRILLS RO systems are laid out according to the last realizations of the revers­osmosis-technology. These installations enjoy ever more severe popularity with Cruisers, sport-fishers and on boats, where mounting space is limited.
The NO FRILLS systems are simple to use and uncomplicated in maintenance. The NF 500 produces about. 78 liters / h, the NF 800 produces, about. 145 liters / h. See the
reduced performance with temperatures below 25°C.
2.2 descriptions of the individual parts
The 230 V boost-pump. (LP Pump)
The boost-pump is required to feed the sea-water, if the high-pressure-pump is built-in at or above the waterline. The booster-pump must be installed below the waterline. The booster­pump supports the start-process, trapped air is fast removed.
Hand-water-test-appliance (Optional) N.A. on COMFORT and COMPACT Models
The hand-water-Tester measures how much ppm of the TDS is still in the water. The value from the World-Health-Organization, WHO, for good drinking water, is 500 ppm.
ppm = parts per million TDS (total dissolved Solids) Pressure gauges
The pressure gauge shows how much pressure the high pressure-pump delivers. The work­area is between 800 and 950 psi. High pressure-pump The high pressure-pump pumps waters through the membrane Flow meter How much drinking water is produced in the hour shows the flow-meter. (In U.S. gallons per hour) 1 U.S. Gallon = 3.78 liters. 2
Pressure Regulator The pressure control allows the operator to regulate the pressure. 800 psi is normal.
Sea-water-filters (option) for BASIC and STANDARD
The sea-water-filter keeps back coarse particles and spares the booster-pump and the pre­filter consequently.
Pre-filter The pre-filter has a permeability of 20/5 microns and filters the fine particles.
Sample Valve (option) N. A. for COMFORT and COMPACT Models
The sample-valve enables to take a water-test directly at the exit of the system. This is to the control the water quality so that one can prevent the influx of bad water.
6
NO FRILLS 500/800 Guides Cleaning-valve (mounted at the pressure regulation)
This valve enables, either a flow over board (Normal Flow), or a recirculation for cleaning and preservation. (Cleaning Flow) See flow diagram.
Fresh-water – flush system (FWS)
The fresh-water – flush system provides flushing the system when not in use, with fresh water, just with a turn of the handle at the selector valve. The build in changeable carbon filter cartridge prevents that chloride exits the membrane. The handle must be installed below the waterline if you install the system acc. Page 12. When installing acc. Page 12a all components except the boost pump can be mounted over the waterline. Flushing the system extends the lifetime of the membrane and is used for short time storage. (up to10 days)
7
NO FRILLS 500/800 guides
Mounting the pressure vessels
The pressure vessels are individually packed and have to be mounted on the brackets. All PV (pressure vessels) are marked with an arrow – feed flow direction -. The PV’s are marked also with PV 1 and PV 2.
From 2015 the Pressure Vessels are pre-mounted. However, for installation you have to separate the Pressure vessels.
PV1 HP Connection
PV2 Product Water
JG Product
HP Hose to Pressure Regulation
HP Hose from HP Pump
Connect the high pressure hose from the HP pump with PV 1, where the yellow spot is located.( only Phoenix vessels ) On Super Duplex Vessels there is a Mark “HP Hose to Pump” or PV1
Connect the high pressure hose from the pressure regulation to PV 2, there is no yellow spot located, but a mark PV2 or “HP Hose to Panel”
Connect the short HP hose, delivered in a plastic bag, to the both right HP hose connections at PV 1 and PV 2. See picture above. From 2015 there is a 316SS Elbow pre-mounted.
Last step is to connect the fresh water hose assy. to the both 3/8” hose barbs or John Guest connections at the PV, right side. How to use the John Guest connections you find at the end of this manual. The Product water connection could be a hose barb, or John Guest connection. That is upon customer’s request.
NOTE!!
All high pressure connections have seals. Don’t tighten the connections to strong,
this could damage the seal. Just a little click with the key is enough.
8
Product Flow Feed Flow
Feed Flow Product Flow
NO FRILLS 500/800 Guides
1 Motor See water inlet
High pressure connection
2 High pressure pump
Attention: On Interpumps: Before starting the Pump, change the red safety transportation cap to the yellow cap with the mark: OIL. This will provide crank shaft ventilation.
For CAT Pumps (blue) remove the tape over the red oil filler cap. The Oil could be removed for transportation by air. Check if oil is in the pump!!!! Recommended is normal non-synthetic 15W40 o
9
Motor and HP Pump
NO FRILLS 500/800 Guide
Installation
The Installation on a boat is very much dependent on the situation. Generally, there is no limitation in length for water hoses. The most common installation is the installation above the waterline. Ref. to the respective diagram. However, some parts have to be placed below the waterline. This is the Sea Water Filter (Strainer) and the LP Pump. The HP Pump should be in a dry place. For better understanding the position of the hoses is marked at the back side of the main Panel. See picture below.
Over board: A ½” hose connected at the main panel must free flow to an outlet well above the waterline. Return Cleaning: This hose connection has to be connected with the “ T “ at the Fresh Water Flush system
(FWF System)
Product Water from Membrane: A ½” hose or a John Guest Tube from the product water outlet to the respective connection at
the main panel.
This is to measure the water firs, before entering the Tank.
To Tank: This is the connection which is the outlet for your product water. Draw a hose to the PH
Stabilizer and from there to your product water storage tank.
Attention!! Always enter your storage Tank from the top!!!
Panel back side
HP Hose from Membrane
Product water to Tank (PH Stabilizer) - over board - return Cleaning - product water from Membrane (could be a JG pipe)
Normal Flow = The Brine water flows over board Cleaning Flow = For cleaning and preservation, activates a circuit flow Cleaning flushing = For all operations where no pressure is needed (fresh water flush, preservation
and cleaning. RO Mode Pressure = to rise the pressure for normal desalination
9a
NO FRILLS 500/800 Guide
FACTORS AFFECTING PERMEATE PRODUCTION
VARIATIONS IN TEMPERATURE, PRESSURE, AND SALINITY
The following table illustrates how the quality and quantity of permeate produced by a RO system is affected by changes in temperature, salinity and pressure:
* If the feed water salt concentration decreases, the product water flow rate should not be allowed to increase more than 20% above rated flow. Feed pressure may need to be lowered to maintain rated flow in brackish water or tap water applications. ** Feed pressure shall not be increased above 950 psi. The RO system can be adjusted to maintain a constant permeate output when feed water temperature and salinity is other than nominal. The operator can do this by controlling system pressure manually via the backpressure regulation valve located in the system brine piping. As permeate flow decreases, the operator can throttle the pressure regulation valve closed to increase system pressure. This, in turn, will increase the permeate output and mitigate the effect of a decrease in temperature or an increase in salinity. Conversely, the operator can open the pressure regulation valve to reduce pressure and permeate flow in areas of excessively high temperature or low salinity.
IN FRESH OR BRACKISH FEEDWATER CONDITIONS, MAKE SURE TO REDUCE PRESSURE BY TURNING REGULATOR. SET PRESSURE SO, THAT PRODUCT FLOW IS NO MORE THAN 120% Of DESIGNED FLOW; TO PREVENT MEMBRANE DAMAGE.
TEMPERATURE CORRECTION FACTOR
As previously described, the output capacity of any RO unit is highly dependent on feed water temperature. In order to quantify this relationship, operational data has been utilized to develop Temperature Correction Factors (TCF). The TCF (which is compensated to 25°C/77°F) is used to determine what part of any change in system output flow is due to variations in feed water temperature alone. This, in turn, allows the operator to establish the baseline flow for a given temperature, allowing more accurate troubleshooting. The procedure for calculating the TCF and the temperature compensated flow is as follows:
1) Measure raw water temperature.
2) Determine the corresponding correction factor from Table 3.2 based on the measured
temperature.
3) Note the product flow rate at the Product Flow meter.
4) Multiply the measure (uncorrected) product flow meter flow rate by the correction factor
from Table.
10
With constant and increasing TDS Capacity
Salinity and pressure Temperature increasing increasing
Temperature and pressure Salinity increases decreases
Temperature and salinity Pressure decreases increases
NO FRILLS 500/800 Guide
Example:
Raw water temp: 15°C TCF: 1.47 Uncorrected product flow: 12.75 (gph) Calculation: 12.75 x 1.47 = 18.743 (gph) Corrected product flow: 18.7 (gph)This is the normal flow for a NF500
(
11
NO FRILLS 500/800 Guide
Flow diagram (Installation above Waterline)
12
NO FRILLS 500/800 Guide
Mounting and connections
On the picture below, you see pressure regulator, looking from the top. This could be adjusted with a 27mm key.
Pressure Regulator
The pressure regulator is a fixed set up type; however, it can be adjusted. The regulator is factory set to 800­820psi (56bar). It might be necessary to adjust. That depends on salinity and temperature. Refer to Temperature and salinity adjustment. But anyhow, the unit will operate with 800psi pressure within the operational limits.
For units equipped with low energy membranes (from 2015) the factory pressure setting is lower than 800psi. Adjust the pressure according to the product flow. If you reach the rated product flow, this pressure is enough. To adjust the pressure, you must loosen the counter screw below the regulator.
Mounting the system:
Find good positions for the components. Motor and Pumps should be in a dry place. Accessible parts are the pressure regulation, the pre-filters and the fresh water flush system. Keep a little space below the filters for changing the filter elements. Install a seacock in the feed water line.
Mount the system according to the flow diagram. All sea water lines are ¾” hoses. Don’t use transparent hoses. All freshwater hoses are 3/8” or ½” We recommend hose qualities which have drinking water grade. The LP pump has to be placed under the waterline. With the
installation on Page 12 you can place all parts, which are not marked red, above the waterline.
13
Pressure Regulator
NO FRILLS 500/800 Guide
TO CONNECT THE ELECTRICAL
TURN OFF ALL ELECTRICAL POWER FOR USE WITH THE RO UNIT PRIOR TO CONNECTING TOTHE RO POWER SOURCE. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATHTO PERSONS HANDLING THE UNIT.
NOTE: Adhere to all electrical codes and regulations governing the installation and wiring of electrical equipment. Typical codes specify the type and size of conduit, wire diameter, and class or wire insulation depending upon the amperage and environment.
NOTE: The power supply should always be of greater service rating than the requirements of the RO unit. This will assure proper voltage even if power supply voltage is slightly less than required. Never connect the RO unit to a line that services another electrical device. THE RO UNIT SHOULD HAVE ITS OWN INDEPENDENT POWER SUPPLY.
NOTE: We recommend use of a 15 amp fuse or circuit breaker for 230 Volts AC units. Cable Identification: N0.1= L - brown No.2 = N – blue The Cables are guided outside the control box at the panel.
We recommend installing a waterproof box between each cable. This makes it easy to dismount the unit.
14
NO FRILLS 500/800 Guide
Starting the System
Step 1: Verify all power switches and power sources are in the OFF position. Step 2: Turn the High Pressure Bypass Valve (Black Valve) to CLEANING/FLUSHING
Position. This procedure allows release of the high pressure air trapped within the system. Verify the Cleaning Valve (Grey Valve) is positioned to NORMAL FLOW discharge. Also check the grey Freshwater Flush Valve is positioned for seawater intake, NOT freshwater.
FAILURE TO OPEN THE HIGH PRESSURE BYPASS VALVE, WHICH IS REQUIRED TO RELEASE ANY TRAPPED AIR, COULD RESULT IN HYDRAULIC SHOCK TO THE SYSTEM.
Step 3: Verify the seawater intake is open at the through-hull. This allows the feed seawater
to flow into the unit. Start-up time can be expedited by filling the pre-filter housing with non-chlorinated
freshwater, before the RO unit is turned on.
Step 4: Switch ON the breaker at main breaker panel to power up unit.
Step 5: Upon start-up inspect all plumbing connections in the unit for leakage. Varying
temperatures during shipment may cause plumbing connections to seep when
starting the RO unit for the first time. Secure the unit and repair any leaks before
proceeding. Once the leaks are repaired, open the raw water source and restart the
unit. Starts the LP pump first, then HP Pump. Step 6: Observe the Brine Flow over board, to ensure all air and bubbles exited the RO
system before proceeding to next step. Step 7: Gradually turn the High Pressure Bypass Valve (Black Valve) to
RO MODE/ PRESSURE position. The pressure gauge should steadily rise to a
reading of 700-820 psi. Step 8: Observe the system pressure on the High Pressure Gauge. During RO production,
the indicated pressure should be at 700-850 psi (depending on Seawater
temperature) If the pressure reading is not at 700-850 psi, adjust the pressure
regulator.
NOTE: If the RO unit is used for other than seawater purification (in freshwater or brackish water applications), reduce pressure as necessary to achieve product flow no greater than 120% of design flow to avoid membrane damage. RO pressure production should NEVER EXCEED 950 psi, doing so risks damage to RO unit which would VOID factory warranty.
Step 9: Taste the water quality or test it with a hand-held test meter to determine water
quality. If quality is good allow the water to flow into the Tank. N.a. for COMFORT and
COMPACT systems there is a controller and you can read the quality. Step 10: Check the RO unit for water leakage periodically at the initial start-up. Observe
Product Flow meter.
Record the product flow after 48 hours of operation (use the sample log sheet
provided).
4.2 TO SHUT DOWN UNIT
Step 1: As the RO unit operates, turn the High Pressure Bypass Valve (Black Valve) to
CLEANING/FLUSHING Position. (Counter clockwise), when RO unit is running. This
will release the high pressure within the RO system. Step 2: Turn OFF your power at the control box.
The RO unit may be left in this “stand by” condition with the seawater for up to seven
days or three days in hot, tropical climates. If the RO unit will be out of service for
extended time periods, please refer to the Maintenance section of this manual. 15
NO FRILLS 500/800 Guide
MAINTENANCE
The service life of most system equipment is directly related to the raw water inlet conditions. Improper maintenance will also significantly reduce the life expectancy of the major unit components (such as the membranes, filters and pumps) as well as the reliability of the unit as a whole. Under normal conditions, and with proper maintenance, a reverse osmosis membrane (which is the major consumable item) should have an effective service life somewhere between 4 and 6 years.
NOTE: The RO unit must be cleaned when product water output drops by 20%. Table 5.1: Maintenance Task Chart.
** Change pump oil after first 100 hours of RO use. After the first oil change at 100 hours, change the pump oil every 500 hours thereafter or once annually which ever interval comes first.
FRESHWATER FLUSH / SHORT TERM STORAGE
Ideally, the No Frills performs optimally when the RO unit is used regularly. The likelihood of bacterial and biological growth in the membranes increases, when stagnant seawater (in extended periods) is in contact with the membranes. A freshwater flush procedure is necessary to prevent clogging and growth of organic contaminants in the RO system and its membranes. This method pushes out older stagnant seawater (saltwater) out of the membranes and replacing it with freshwater (non-saltwater), leaving less chance of fouling the membranes. The freshwater flush procedure should be used when the unit will be placed idle or in “stand by” condition for more than several days OR idle for three days in hot, tropical climates. Although they do not attack the membranes or other system components directly, high concentrations of biological matter can block enough of the product water channels to cause a reduction of as much as 40% of the total system capacity.
16
NO FRILLS 500/800 Guide
PERFORM A FRESHWATER FLUSH TO THE RO UNIT WITH NON-CHLORINATED FRESH WATER ONLY. EXPOSING THE MEMBRANES TO CHLORINATED WATER WILL CAUSE IRREVERSIBLE DAMAGE AND VOID THE RO UNIT WARRANTY. THE FRESHWATER FLUSH SYSTEM USES A CARBON FILTER INLINE BEFORE SYSTEM TO CONSUME THE CHLORINE THAT MAY BE PRESENT FROM THE DOCK WATER.
TO FLUSH THE NO FRILLS UNIT
Step 1: Verify all power switches and power sources are turned OFF. Step 2: Turn ON your water pressure and watermaker breakers on main electrical panel.
Turn the High Pressure Bypass Valve to CLEANING/FLUSHING (ensuring zero
pressure in system). Verify the gray Cleaning Valve is positioned to NORMAL FLOW
position. Step 3: Turn the gray Freshwater Flush Valve to FRESHWATER position. Step 4: Turn the switch at the control panel to ON (HP pump only) Step 5: Verify the freshwater supply pressure does not exceed 35 psi. Step 6: After flushing the unit for two minutes, turn the switch at the control panel to OFF. Step 7: Turn the gray Freshwater Flush Valve to SEAWATER position. Leave RO unit in
standing condition, for up to three weeks. Then re-flush or preserve. Step 8: To restart the NO FRILLS, refer to instructions: TO START THE NO FRILLS UNIT.
CHEMICAL CLEANING PROCEDURE
The RO unit must be chemically cleaned when product water output drops below 80% of original production. The frequency of this occurring will vary greatly upon feed water. Fouling odor from the membrane will naturally occur during regular usage of the RO unit. The fouling odor will progress without proper cleaning of the membranes, therefore reducing the efficiency of the RO unit.
THE USE OF CHEMICALS OR CLEANING METHODS OTHER THAN THOSE OUTLINED IN THIS MANUAL WILL VOID THE RO UNIT WARRANTY. NON-IONIC SURFACTANTS USED FOR MEMBRANE CLEANING OR ANY OTHER CHEMICALS NOT APPROVED IN WRITING BY PUREWATER, WILL VOID THE RO UNIT WARRANTY. CLEANING CHEMICAL #1 IS AN ALKALINE DETERGENT, USED TO REMOVE OIL, GREASE, BIOLOGICAL MATTER, AND GRIME FROM THE SURFACE OF THE RO MEMBRANES. SEE WARNING LABEL ON SIDE OF PACKAGE AND OBSERVE ALL SAFETY PRECAUTIONS ON LABEL. CLEANING CHEMICAL #2 IS AN ACID, A MINERAL SCALE REMOVER. SEE WARNING LABEL ON SIDE OF PACKAGE AND OBSERVE ALL SAFETY PRECAUTIONS ON LABEL. NOTE: All cleaning and preservation procedures can be done with either NON­CHLORINATED freshwater to optimize performance of cleaning process, or see water. NOTE: You should allow your unit’s product water to run and drain for the first 30
minutes after cleaning or upon start up after preservation.
17
NO FRILLS 500/800 Guide
CLEANING STEPS FOR CHEMICAL #1 AND #2
Single Use Cleaning Cartridges Powder Form
18
Step1. Prior cleaning the RO perform a fresh water flush to the system. Turn the handle at the freshwater flush system to SEA WATER operation to stop the fresh water flow.
Step2. Remove the 5 micron filter from housing
Step3. Place cleaning filter #1, blue stripe, into filter housing and close it.
Step4. Place High Pressure Bypass valve in cleaning pos.
Step5. Turn Cleaning Valve in Cleaning Pos.
Step6. Start the RO Unite and let it run for 30 Min.
Step7. Stop the RO system and turn the cleaning valve to NORMAL FLOW. Then flush the system with fresh water.
Step8. Place the Cleaning Filter#2, red ring, into the filter housing and start with Step4 to Step7.
Step9. Place a new 5 micron Filter into the housing.
Step1. Prior cleaning the RO perform a fresh water flush to the system. Turn the handle at the freshwater flush system to SEA WATER operation to stop the fresh water flow.
Step 2. Place 5 TBSP of #1 into the filter housing and fill with clean water.
Step3. Crystals need to be completely dissolved before proceeding to next step. Screw housing back into place.
Step4. Place High Press. Bypass in Cleaning pos.
Step5. Turn Cleaning valve into cleaning.
Step6. Start the RO Unite and let it run for 30 Min.
Step7. . Stop the RO system and turn the cleaning valve to NORMAL FLOW. Then flush the system with fresh water.
Step8. Place 4 TBSP of chemical#2 into the filter housing and repeat the Step3 to Step7.
NO FRILLS 500/800 Guide
LONG TERM STORAGE / PRESERVATION PROCEDURE
During periods when the RO unit is to be shut down for an extended period of time, it is necessary to re-flush the unit every three weeks OR to circulate a preservative solution through the membrane to prevent the growth of biological organisms. Use the following procedure to preserve the RO elements:
PRESERVATIVE CHEMICAL #3 IS A FOOD GRADE PRESERVATIVE. SEE WARNING LABEL ON SIDE OF PACKAGE AND ADHERE TO ALL SAFETY PRECAUTIONS ON LABEL.
NOTE: You should allow your unit’s product water to run to drain for the first 30
minutes after cleaning or upon start up after preservation. The procedure is the same than cleaning Step 1 to Step 6. Step 7 is to remove the
cleaning filter and leave everything as it is until using the RO system again. Use either Cartridge or powder for preservation. Use 3 TBS of powder.
OIL CHANGE PROCEDURE
An oil change is recommended after the first 100 hours of RO use. Subsequent oil changes are to be performed every 500-hour intervals OR changed annually. Change oil any time moisture is detected or if oil is cloudy. For additional pump information, refer to MANUFACTURER’S LITERATURE at the back of this manual. Or CAT Pumps CD.
NOTE: The first oil change requires a complete oil drain, to ensure your pump is free of any fragments. DO NOT RUN PUMP WITHOUT OIL IN THE CRANKCASE. NOTE: Prior to the oil change, it MAY facilitate the oil replacement process by running the RO unit to heat the oil. Heating the oil reduces the viscosity allowing it to be more fluid to travel through the pump.
19
NO FRILLS 500/800 Guide
Change of Membranes
End cap Membrane Brine Seal(Seawater side) Pressure Vessel End cap
To change the membrane, start on the side, where the sea water is going out. (HP hose to Panel) At the beginning of the arrow Feed Flow Direction is the seawater side. Turn out the End cap of the opposite side by using a key. (5mm face spanner) Then you can take out the Membrane. The Brine Seal is in the End Cap. For installing a new Membrane you have first to change the seal at the Membrane to the opposite side. See picture above.
Before installing the new membrane, lubricate everything with SILICON GREASE or Glycerine. Don’t use any other lubricant. Any other lubricant will damage the membrane.
Push the new membrane into the PV and push the end cap in position.
PW Super Duplex Pressure Vessels
20
5mm holes for special key to turn the end-caps off (counter clockwise)
HP Connection
Freshwater connection
NO FRILLS 500/800 Guide
Endkappen bei Phoenix Druckgehäusen
Endcaps with Phoenix pressure vessels
5mm
Inbus/Allen
Die Phoenix Druckgehäuse unterscheiden sich von den AQUA PRO Gehäusen nur durch die Farbe und die Endkappen.
Zum Wechsel der Membran lösen Sie die beiden Inbusschrauben. Sie können dann die Befestigungen herausnehmen. Legen Sie diese so auf eine Arbeitsplatte, wie Sie diese herausgenommen haben. Das erleichtert den Einbau später. Ziehen Sie dann die Kunststoffendkappe mit einer Zange, die Sie am Anschluss für den Hochdruckschlauch ansetzten, hinaus. Fetten Sie die Dichtung mit Silikonfett. Dann können Sie die Membran herausziehen. Setzten Sie die neue Membran in der gleichen Richtung wieder ein. Achten Sie darauf, dass der Dichtungsring an der Membran an der gleichen Stelle ist. Er muss immer an der Seite des Gehäuses sein, wo das Seewasser eintritt. Drücken Sie dann die Kunststoffendkappe wieder in das Gehäuse hinein und setzten Sie die Sicherungsbolzen wieder ein. Sichern Sie diese wieder mit den beiden Inbusschrauben.
To Change the Membrane: Loose the two 5 mm Allen screws, take the three fasteners out. Pull the plastic endcap out
(use two screw drivers).Than pull the membrane out. Insert the new membrane. The black seal must be at the side, where the yellow spot is located on the pressure vessel. Use only silicon grease. Then press the endcap back into the pressure vessel and install the fasteners the same way, you took them out.
20a
NO FRILLS 500/800 Guide
Manufactures Literature (For Interpump) CAT Pumps will have an attached CD)
21
NO FRILLS 500/800 Guide
Manufactures Literature
22
NO FRILLS 500/800 Guide
Manufactures Literature
23
NO FRILLS 500/800 Guide
Logbook
Modell #_________
Manufactures date__________
Sea water temperature
Pressure
Product flow
Salinity Sea water
Salinity product water
PH Sea water
24
NO FRILLS 500/800 Guide
Quality Monitor (COMPACT and COMFORT Versions)
The Quality Monitor shows the quality of the product water in PPM TDS (Part per Million Total dissolved Solids) It is switched on with the LP Pump switch.
When starting the system, the quality is always for a short period (30-45sec) high salinity. Shortly the monitor starts to count down. As soon as the quality reaches the pre-set value (factory set point is 500PPM) the water is produced into the tank.
The controller is activating a diversion valve to control the destination of the product water. The diversion Valve is located at the right side of the Main control panel. There is an emergency gray button, to override the valve. Only to be used, when the controller is not working. Push and turn to the right to lock.
25
Digital Display ppm
Switch OFF- AUTO- ON Normal position is AUTO. OFF= Controller is OFF AUTO= Controller is in the AUTO position. Automatic product water transfer to tank. ON= Product water is always produced into tank.
LED display: RED Controller is OFF Amber= Water is produced into tank. Green= Water is going over board
Calibrating screw
Set Point for adjusting product water set value. To readjust, push the yellow set button and turn with a tiny screwdriver the desired set point. Return- push MEAS
NO FRILLS 500/800 Guide
The John Guest System
26
NO FRILLS 500/800 Guide
Wiring
27