Installation Guide
9. Restore the water supply and check for leaks.
10. Run the system for at least 5 minutes to remove carbon nes. Water may appear
milky, but this is normal and is only tiny air bubbles that will clear aer a short period.
Cartridge Installation/Changeout
1. Place container under lter in case of drips.
2. Twist out old cartridge. Discard old cartridge.
3. Remove packaging from the new cartridge including the yellow cap on top of the
cartridge. Twist in the new cartridge. Ensure rm seal to head.
Replacement cartridge code: Puretec QT12R
4. Reset LED indicator by following instructions on page 6.
5. Restore water supply.
6. Check for leaks, rectifying them, if any, before leaving the unit.
Aer installing cartridges ush unit for 5 - 10 minutes.
Use Guidelines
• Minimum operating pressure 100 kPa.
• Maximum operating pressure 875 kPa.
• Do not allow exposure to temperatures below 3°C.
• Maximum operating temperature 38°C.
• Maximum ow rate 5 Lpm.
• This system must be installed according to local plumbing codes on the cold water line
- mains only.
• Replacement Cartridges: See Cartridge Changeout section
• This system requires regular replacement of the lter cartridge to maintain proper
operation. Varying chlorine, sediment, or organic substance levels may aect
replacement frequency.
• Be sure to change the lter cartridge at least every 11,355 litres or 6 months which
ever occurs rst; or whenever you detect a change in taste, odour, or decrease in ow.
Caution: Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or aer the system.