01 Introduction of RS-103TDS
02 What is reverse osmosis
03 Components & Selected filters
04 Cartridge filters
05 The parts of RS-103TDS
06 LCD display
07 Tubing connection diagram
08 Installation diagram
09 Change filters
10 Change membrane
11 Operation regulation
13 FAQ
14 Maintenance checking list
15 Memo
Thank you very much for selecting Pure-Pro Water Corp.
In order to bring the best use of your system, please read
the user's manual carefully before installation and follow
the regulations.
Memo
RO Computer Controller
T.D.S.(XI ppm)/Time(X 10m)
FULL
FLUSH
WORK
SOURCE
MANUAL
T.D.S./Time
MANUAL FLUSH
RESET
ROYAL Reverse Osmosis Drinking Water Systems
01
PURE-PRO REVERSE OSMOSIS SYSTEM
14
PURE-PRO REVERSE OSMOSIS SYSTEM
P
R
O
P
URE
DRINKING WATER SYSTEM
P
R
O
P
URE
DRINKING WATER SYSTEM
Introduction of RS-103TDS
¨RS-103TDS Quick-change cartridges RO system
®
PurePro ROYAL RO system uses the most advanced water treatment technology: "Reverse Osmosis". Reverse Osmosis (RO) is recognized as one of the best available technologies for producing best quality drinking water. It's also the same method used by many bottled water companies to make safe and great tasting water. No other home water treatment system can offer you as much protection and reliability.
®
PurePro ROYAL RO system uses 100GPD membrane which is powerful, fast and excellent efficiency. 100GPD membrane increase the daily production capacity and the speed of RO water production. This allows for better assurance that there is adequate water available when desired, even during heavy use times of the day. PurePro ROYAL RO with its supreme quality ensures a great water flow rate with absolutely the least wasting of water.
The newly designed ROYAL RO system is user friendly with design simplicity in mind. It requires no tools for filter changes. Use twist and quick-change cartridge design makes filter changes fast, clean and easy. This space saving allows maximum use of your under counter space.
Maintenance checking list
Date
Filters
1st stage 2nd stage 3rd stage
4th stage 5th stage
Other items
Production: 100 GPD / 378 LPD Water storage tank: 3.2gallons / 12.2 liters With a booster pump (optional): Input in AC 110Volt, 220Volt or 240Volt (50/60Hz) Operation pressure: 5 -80 psi Dimensions: (cm)27.5 (L) x 44.5(H) x 26.5 (W) Weight: 8 kg - system
4 kg - tank
¨Specifications
ROYAL Reverse Osmosis Drinking Water Systems
ROYAL Reverse Osmosis Drinking Water Systems
Reverse osmosis was originally designed to make sea water drinkable for the
navy. It is ideal for anyone on a low sodium diet. An R.O. membrane has a pore
size much smaller than bacteria virus, or the cryptosporidium parasite. When
functioning properly it will remove all microorganisms from tap water and produce
sterile water. Reverse osmosis is the reversal of the natural flow of osmosis. In a
water purification system, the goal is not to dilute the salt solution, but to
separate the pure water from the salt and other contaminants. When the natural
osmotic flow is reversed, water from the salt solution is forced to pass through the
membrane in the opposite direction by application of pressure-thus the term
REVERSE OSMOSIS. Through this process, we are able to produce pure water
by screening out the salts and other contaminants.
13
PURE-PRO REVERSE OSMOSIS SYSTEM
02
PURE-PRO REVERSE OSMOSIS SYSTEM
P
R
O
P
URE
DRINKING WATER SYSTEM
P
R
O
P
URE
DRINKING WATER SYSTEM
What is reverse osmosis
Reverse Osmosis
Pressure
Membrane
Water flow
FAQ
ROYAL Reverse Osmosis Drinking Water Systems
ROYAL Reverse Osmosis Drinking Water Systems
Q: What is the guarantee on the PurePro system ?
The PurePro system (excluding filters) is guaranteed for 1 year for material and workmanship. All defective parts will be replaced free within the first year under natural breakdown. The membrane has one year pro-rated guarantee.
Q: What factors affect the quantity and the quality of the water production?
There are four major variables to consider:
1.Pressure-The greater the water pressure, the better water quantity and quality it produced. Water pressure of 60 PSI is ideal.
00
2.Temperature-76 F is the ideal water temperature for R.O. 40 F water will
0
cause the production of R.O. water to fall to half of that at 76F. The maximum
0
water temperature recommended is 85 F.
3.Total Dissolved Solids (TDS)-The higher the amount of dissolved contaminants in the water, the lower the quantity of water produced. A high level of TOTAL DISSOLVED SOLIDS can be overcome with additional water pressure.
4.Membrane-Different membranes have different characteristics. Some produce more water than others; some have better contaminant rejection capabilities; some have greater resistance to chemical abrasion for longer life. PurePro system includes TW30-1812-100 The Thin Film Composite (TFC) membranes combine the best of these characteristics and are considered the finest membrane in the world.
Q: Can the PurePro system be connected to an extra faucet?
It only takes a 1/4" tee and tubing to run the water to a refrigerator or a extra faucet. Some families run PurePro system to all of their bathrooms.
Q: What does the PurePro series drinking water taste like?
The taste of the PurePro water depends on the amount of contaminants in the tap water originally. If 95% of dissolved minerals and chemicals are removed, the R.O. water may taste like distilled water (no minerals), bottled water (low mineral), or natural spring water (moderate mineral content).