Pure n Natural Systems FM22 H.E.P.A. User Manual

Page 1
FM22 H.E.P.A. AIR CLEANER USERS MANUAL
READ AND SAVE THESE INSTRUCTIONS
Pure n Natural Systems, Inc. recommends that a licensed electrician or licensed
contractor install units.
WARNINGS:
1. Always unplug or disconnect the air cleaner from power supply before servicing.
rain, do not use in a window.
3. Do not use this fan with any solid state speed control device.
FILTER CHANGING:
1. Pre Filter - Replace every 3 to 4 weeks.
2. Carbon Panel Filter - Replace at least every 2 months.
3. H.E.P.A. Filter - Replace at least every 12 months.
Step 1. The Pre Filter is located behind the intake door (service door). The Pre Filter is a blue and white polyester, pre-tack filter. The intake door is located closest to the HI/LO/OFF switch on the face of the system. Unclip the two latches on the intake door and the door will swing down. The Pre Filter is the first filter behind the intake door. Peel away dirty Pre Filter and discard. Install the new Pre filter with the white side out. Close door. DO NOT WASH PRE FILTERS.
Step 2. The carbon filter is located behind the Pre Filter. Follow Pre Filter changing instructions from Step 1. Remove Carbon Filter, discard and replace with new Carbon Filter. DO NOT WASH CARBON FILTERS.
Step. 3. Remove the adjustable louver door. Remove the H.E.P.A. Bar. The H.E.P.A. Filter is a pleated media surface with a metal frame. Slip the H.E.P.A. Filter out of the system, discard and replace with new H.E.P.A. Filter. DO NOT WASH H.E.P.A. FILTER.
Filter maintenance may vary according to each situation.
For any questions, please contact our customer service department at 1-800-237-9199.
Page 2
INSTALLATION OF MODEL FM22
FOR
SOLID CEILINGS
1. Remove the system from the shipping container and remove all 3 filters, including
HEPA filter and HEPA bar at exit end.
2. After deciding location and direction of air flow, locate the studs between which
the unit will be positioned.
3. Mark out the area where the ceiling will be cut. (Min. 47” x 22-½”)
4. Remove the piece of ceiling that has been cut, and remove all screws, nails, etc.
from the cut out area.
5. At this time, locate an electrical source from above the cut out area, and plug in
the unit.
6. Remove service door and screws that hold the door frame. Also remove
adjustable exit louver.
7. Raise unit into the ceiling. (Leave the unit protruding from the ceiling depending
on the thickness of molding that you are using to frame around unit.)
8. At this time, from inside the unit, affix (screw) unit to studs. Position the screws
as close to the top of the studs as possible. This will make the removal of the adjustable exit louver easier. We suggest the use of 1-½” to 2” Phillips pan head screws and fender washers for stability. We also suggest that you use 2 screws in each quadrant for support.
9. Replace service door frame to unit, install Pre Filter and Carbon Filters, and clip
on the service door. At opposite end of unit, install the H.E.P.A. Filter and H.E.P.A. bar. Replace the adjustable exit louver.
10. Frame unit in with your choice of material. (See #7)
For any questions, please contact our customer service department at 1-800-237-9199.
Page 3
FM22 CUSTOM SOLID CEILING APPLICATION
The FM-22 Flushmount Air Cleaner is designed for a flushmount installation in a solid ceiling with 24" on center joists. A 13" depth clearance is required above ceiling. After
the FM-22 is secured to joists, a finished molding is recommended for appearance. It is recommended that the air cleaner is installed in areas that do not exceed a 12 ft. ceiling height. All filters on the FM-22 are accessible from the louvered doors on the face of the system.1 unit recommended for every 1200 square feet.
• 1200 C.F.M.
• 46-1/2" L x 22" W x 12" H
• 18 gauge galvanized steel cabinet
• Shipping Weight - 85 lbs.
• 4.2 amps, 120V, two speed
• 10 ft. power cord, 3 prong ground plug
• Three Filter System: 12" deep HEPA, 1/2" activated carbon filter, 1/2" polyester tackified pre-filter
• All systems carry a lifetime motor/blower warranty
• All electrical components and fan motor are UL Listed and CSA Certified.
For any questions, please contact our customer service department at 1-800-237-9199.
Pure n Natural Systems, Inc.
P.O. Box 1137 Streamwood, IL 60107
Toll-Free – 1-800-237-9199 Fax – 847-470-1686
www.purennatural.com