This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other
than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the
sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is
or has ever been under an Intertek certification program.
Note: The Energy Star Schema requires selecti n g values from a single unit or averaging of values of one unit with multiple filters for
the ENERGY STAR values. Averaging is not available for multi ple units.
CADR
Room Size
200701040GZU-001
Midea
200701040GZU-001
Midea
200701040GZU-001
Midea
Administrator,
AHAM Room Air Cleaner Certification Program
3933 US Route 11, Cortland, NY 13045
Tel: (607) 758-6366
AHAM PORTABLE ELECTRIC ROOM AIR CLEANER CERTIFICATION PROGRAM
NOTICE OF MAXIMUM CERTIFIED RATING (A-7)
GD Midea Environm ent Appliances MFG Co., Ltd.
28 Dongfu Road, Hesui East Industrial Area, D ongfeng, Zhongshan, Guangdong, China
Enclosed is a copy of a room air cleaner certification testing report for the following units. These values are to be used should your
company choose to certify the following models in the AHAM Portable Electric Room Air Cleaner Certification Program.
Test Report No.Brand
The tests indicate t hat the certified val ues m ust not exceed the following:
VoltageFrequency (Hz)
SmokeDustPollen
1206020821022632230
Does this model meet the ENERGY STAR v 2.0 requirements?
Connected Wi-Fi Functionality?
In accordance with the terms of the AHAM Portable Electric Air Cleaner Certification Program Procedural Guide, model data must be
submitted to the Program Laboratory on Form A-1 to become certified and to be included in any future Directory / Listing.
Reference should be made to the License Agreement and the Procedural Guide describing operation of the Program for additional
explanation of procedures to be followed in this action.
Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-
China
GD Midea Environment Appliances MFG Co., Ltd.
GD Midea Environment Appliances MFG Co., Ltd.
28 Dongfu Road, Hesui East Industrial Area, Dongfeng, Zhongshan,
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
Prototype
AHAM AC-1-2019
14-Oct-2020
Rated voltage (V)
Rated power (W)
Rated frequency (Hz)
The product covered by this report is a cord connected indoor used only Air
Purifier.
None
28 Dongfu Road, Hesui East Industrial Area, Dongfeng, Zhongshan,
The results reported are within the minimum and maximum limits of
Midea, TAOTRONICS
KJ350G-S1, TT-AP003 are same except model number.
KJ350G-S1, TT-AP003
Test Laboratory Name / Address
8/F., No.7-2, Caipin Road, Science City, G E TDD, Guangz hou, Guangdong,
Applicant Name / Address
Guangdong, China
Manufacturing Name / Address
Guangdong, China
ProductAir Purifier
Brand Name
Description
Model(s) (if applicable)
Model Similarity
Date of receipt of sample(s)
Date of test
Sample Condition
Test standard(s) or criteria(s)
ENERGY STAR® Program Requirements Product Specification for Room
Air Cleaners Eligibility Criteria: V ersion 2.0
Conclusion
measurability of the AHAM AC-1-2019 "Association of Home Appliance
Manufacturers Method for Measuring Performance of Portable Household
Electric Room Air Cleaners" Test Method and meet the requirements of
EPA Energy Star version 2.0
Date of issue
Date of revision
Prepared by:Approved by:
Ben DengMichael Hudon
Project EngineerLab Manager
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liabil ity to any party, other than to
the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for
the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test
results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or
has ever been under an Intertek certification program.
The test report only allows to be revised only within the report defined retention period unless standard or regulation was withdrawn or
invalid. When determining the test result, m easurement uncertainty has been considered.
The following device settings were used during testing: 120V/60Hz, High S peed, Tested on the Floor
Aerodynamic Particle
Fluidized Bed Aerosol
Test Method:
Tests were performed in accordance with AHAM AC-1-2019 entitled "Association of Home Appliance
Manufacturers Method for Measuring Performance of Portable Household Electric Room Air Cleaners". This
standard method has defined limits of measurability. The practical limits of measurability are: Dust 10 to 400
CADR, Tobacco smoke 10 to 450 CADR and Pollen 25 to 450 CADR. The statistical validity of test results
outside of the stated practical limits is questionable and unevaluated. Clean Air Delivery Rat es (CADR's)
were determined using Tobacco Smoke, AC Fine Test Dust, and Paper Mulberry Poll en.
Additional requirements for energy taken from IEC 62301 Ed. 2 entitled, “Household Electrical Appliances –
Measurement of Standby Power”.
Monitored particle size ranges for the three particulates were as follows:
Smoke - 0.10-1.0 microns; Dust - 0.5-3 microns; Pollen - 5-11 microns.
Test Equipment List:
Equipment Name
Laser Aerosol Spectrometer
Sizer
Generator
Air Cleaner testing Chamber
TypeCalibration DateDue Date
33405/26/20205/25/2021
33211/13/20201/12/2021
3400A6/10/20206/9/2021
Number
SA016-23-04
SA016-23-05
SA016-23-05
SA016-23
Device Under Test Description:
The device(s) tested for this report were/was Model KJ350G-S1
The results reported are within the minimum and maximum limits of measurability of the AHAM AC-1-2019
"Association of Home Appliance Manufacturers Method for Measuring Performance of PortableHousehold
Electric Room Air Cleaners" Test Method.