Pulsar VD53, VD54 User Manual

CAL. VD53 & VD54
CHRONOGRAPH
ENGLISH
TIME/CALENDAR
l
Hour, minute and second hands
l
Date displayed in numerals (VD53 only)
l
Measures up to 60 minutes in one second increments.
CALIBER OF THREE HANDS WITH THREE EYES (MINUTES, 1/1 SECOND CHRONOGRAPH, 24-HUOR INDICATOR)
English
2
English
3
HOUR.
24
6
12
18
60
45 15
30
60
5
SCREW DOWN CROWN
[for models with screw down crown]
Locking the crown
1
Turn Crown counterclockwise until you no
longer feel the threads turning.
2
Crown can be pulled out.
1
Push Crown back in to normal position.
2
Turn Crown clockwise while pressing it
lightly until tight.
Unlocking the crown
DISPLAY AND CROWN/BUTTONS
c: Second click
b: First click
a: Normal position
Hour hand
STOPWATCH
minute hand
24 - hour hand
Minute hand
A
a b c
B
Date (VD53 only)
Second hand
CROWN
STOPWATCH second hand
English
4
English
5
HOUR.
24
6
12
18
60
60
45 15
30
5
60
45 15
30
60
ADJUSTING THE STOPWATCH HAND POSITION
l
Before setting the time, be sure to check that the STOPWATCH
hands
are in the “0” position when the
STOPWATCH is reset
(for resetting
the STOPWATCH, see "STOPWATCH".)
A
B
Press A or B to reset the STOP­WATCH second and minute hands to the “0” position.
s
STOPWATCH minute hand
Push back in to normal position.
CROWN
STOPWATCH second hand
A
B
CROWN
Pull out to second click
s
OR
A: The hands move counterclockwise. B: The hands move clockwise.
* If either of the STOPWATCH hands is not at the "0" position, reset
them , following the procedure below:
CROWN
TIME SETTING
Date (VD53 only)
Hour hand
Minute hand
Second hand
l
Before setting the time, check that the stopwatch measurement is
stopped.
1 Pull out to first click, and turn clockwise until the previous day’s date appears. (VD53 only)
2
Pull out to second click when the second hand is at the 12 o’clock position. The second hand will stop on the spot. And advance the hour and
minute hands by turning the crown.
3 Turn clockwise until the desired date appears. (VD53 only) 4 Turn to set the hour and minute hands. 5 Push back in to normal position in accordance with a time signal.
English
6
English
7
HOUR.
24
6
12
18
60
60
45 15
30
5
STOPWATCH
l
The stopwatch can measure up to 60 minutes in one second increments.
l
The measured time is indicated by the STOPWATCH hands that move inde
-
pendently of the center and 24-hour hands.
l
Before using the stopwatch, be sure to check that the crown is set at the nor
-
mal position and that the STOPWATCH hands are reset to the “0” position.
A
Start / Stop / Restart
B
Reset
STOPWATCH
second hand
STOPWATCH
minute hand
* If the STOPWATCH hands do not return to the "0" position when the stopwatch is
reset, follow the procedure in "STOPWATCH HAND POSITION ADJUSTMENT".
Standard measurement
START
s
A
STOP
s
B
RESET
Accumulated elapsed time measurement
A
START
s
A
STOP
s
A
s
RESTART
STOP
s
B
RESET
A
A
Split time measurement
A
START
s
SPLIT
s
s
SPLIT RELEASE STOP RESET
s
B
A
B
B
English
8
English
9
NOTES ON OPERATING THE WATCH
TIME SETTING
l
Do not press any button when the crown is at the second click position, as this will
move the STOPWATCH hands.
l
When the time is set, the 24-hour hand move correspondingly with the hour and minute hands.
l
When setting the hour hand, check that the 24-hour hand is correctly set.
l
When setting the minute hand, first advance it 4 to 5 minutes ahead of the desired time and then turn it back to the exact minute.
[Date setting (VD53 only)]
l
It is necessary to adjust the date on the first day after a 30-day month and February.
l
Do not set the date between 9:00 p.m. and 1:00 a.m., as the date may not change
properly. If it is necessary to set the date during that period of time, first change the time to any time outside of this period, set the date, and then reset to the correct time.
STOPWATCH
l
Restart and stop of the stopwatch can be repeated by pressing button A.
l
Measurement and release of split time can be repeated by pressing button B.
BATTERY CHANGE
Battery life : Approx. 2 years
Battery : SEIKO SR920SW
2
Years
l
If the stopwatch is used for more than 2 hours a day, the battery life may be less
than the specified period.
l
As the battery is inserted at the factory to check the function and performance of the watch, its actual life once in your possession may be less than the specified period.
l
When the battery expires, be sure to replace it as soon as possible to prevent any
malfunction.
English
10
English
11
HOUR.
24
6
12
18
60
45 15
30
60
5
l
Battery life indicator
When the battery nears its end, the second hand moves at two-second intervals instead of normal one-second intervals. In that case, have the battery replaced with a new one as soon as possible.
* The watch remains accurate while the second hand is moving at two-second
intervals.
l
We recommend that you contact an AUTHORIZED PULSAR DEALER for battery
replacement.
l
After the battery is replaced with a new one, adjust the stopwatch hand position and
set the time/calendar.
l
Necessary procedure after battery change
AND
Press and hold simultaneously for 2 seconds or longer.
Press to reset the STOP
­WATCH second and minute hands to the “0” position.
After the battery is replaced with a new one, or in case any of the hands should move
improperly, follow the procedure below to reset the
STOPWATCH
hands to “0” po-
sition.
* The STOPWATCH second hand
turns counter clockwise, and then returns to where it was.
s
Turn to set the time.
Push back in to normal position.
s
Pull out to second click.
s
* The ST OPWATCH mi nute
ha nd mov es cor resp ond­ingly with the STOPWATCH second hand.
* Th e STO PWATC H han ds
mo ve q uic kly if t he r e­spect ive buttons a re kept pressed.
B
A
CROWN
B
A
B
A
CROWN
CROWN
A: The hands move counterclockwise. B: The hands move clockwise.
OR
s
English
12
English
13
WARNING
l
Do not remove the battery from the watch.
l
If it is necessary to take out the battery, keep it out of the reach of
children. If a child swallows it, consult a doctor immediately.
l
Never short-circuit, tamper with or heat the battery, and never ex-
pose it to fire. The battery may burst, become very hot or catch fire.
CAUTION
l
The battery is not rechargeable. Never attempt to recharge it, as this
may cause battery leakage or damage to the battery.
TO PRESERVE THE QUALITY OF YOUR WATCH
WATER RESISTANCE
l
Non-water resistant
l
Water resistance (5 bar)*
If “WATER RESI STANT 5 BAR” is i nscri bed on the c ase back, yo ur wa tch i s de si gn ed and
manu-factured to w ithstand up to 5 bar and is suitable for sw imming, yachting and taking a shower.
If “WATER RESISTANT 10 BAR”,
“WATER RESISTANT 15 BAR” or
“WATER RESISTANT 20 BAR” is
inscribed on the case back, your
l
Water resistance (10 bar/15 bar/20
bar)*
watch is designed and manufactured to withstand up to 10 bar/15 bar/20 bar and is suitable for taking a bath, shallow diving, but not for scuba diving. We recommend that you wear a PULSAR Diver’s watch for scuba diving.
If “WATER RESISTANT” is not inscribed on the case back, your watch is not water resistant, and care should be taken not to get
If “WATER RESISTANT” is inscribed on the case back, your wa tch is de signe d an d manufact ured to withstand up to 3 bar, such as acci-
l
Water resistance (3 bar)
dental contact with splashes of water or rain, but it is not designed for swimming or diving.
it wet as water may damage the movement. If the watch becomes wet, we suggest that you have it checked by an AUTHORIZED PULSAR DEALER or SERVICE CENTER.
English
14
English
15
* Before using the water resistance 5, 10, 15 or 20 bar watch in water, be sure the
crown is pushed in completely.
Do not operate the crown when the watch is wet or in water. If used in sea water,
rinse the watch in fresh water and dry it completely.
* When taking a shower with the water resistance 5 bar watch, or taking a bath with
the water resistance 10, 15 or 20 bar watch, be sure to observe the following:
Do not operate the crown when the watch is wet with soapy water or shampoo.
If the watch is left in warm water, a slight time loss or gain may be caused. This condition, however, will be corrected when the watch returns to normal tem­perature.
NOTE: Pressure in bar is a test pressure and should not be considered as cor­responding to actual diving depth since swimming movement tends to increase the pressure at a given depth. Care should also be taken on diving into water.
TEMPERATURES
Temperatu res over 60° C (140° F) may cause batter y lea kage or sho rt
-
Your wa tch wo rks with stabl e accuracy within a tempera ture ra nge o f 5 ° C and 35° C (41° F and 95° F).
en t he batt ery li fe. Do no t leave your watch in very low temperatures below –10° C (+14° F) fo r a lon g tim e sinc e the cold may cause a slight time loss or gain. However, the above conditi ons will be corr ecte d whe n the watch re
-
turns to no rmal te mperatur e.
MAGNETISM
Your wa tch wi ll b e ad ­versely affe cted by strong magnetism. Keep it away fr om cl ose con tact wit h magnetic obj ects.
Be careful not to expose th e wa tch to sol vent s, mercury, cosmetic spray, detergents, adhesives o r paints. Othe rwise, the
CHEMICALS
case, b race let, etc . may bec ome di sco lored, det eri orat ed or dam­aged.
Li ght a cti vities w ill not affect your watch , but be careful not to drop your wa tch or h it i t ag ain st ha rd sur face s, a s this
SHOCKS & VIBRATION
may cause dam age.
To prevent possible rusting of the case and bracelet caused by dust, moisture and perspi­ration, wipe them periodically with a soft dry cloth
.
CARE OF CASE AND BRACELET
It is reco mmended that the wa tch be che cked on ce every 2 to 3 years. Have your watch checked by an AU TH OR IZ ED PU LS AR
PERIODIC CHECK
DE ALE R or SERV ICE CEN TER to ensure that the case, crown, buttons, gaske t and cr ystal seal rem ain intact.
PRECAUTION REGARDING CASE BACK PROTECTIVE FILM
If your watch has a pro­tective fi lm and/or a sti cker on the case back, be sure to peel them o ff before us ­ing your watch.
Loading...