The power supplies in the Dimension X-Series include
a new and innovative concept for generating an
isolated DC voltage from a three-phase mains
system.
A semi-regulated resonant converter enables a very
compact design, maximum efficiency and extremely
competitive pricing with only a small compromise in
the output voltage regulation, output ripple and
hold-up time.
Weighing just 1.4 kg, the device provides 960 watts
of continuous output power and an additional 25%
power reserve for dynamic loads. The light-weight
design along with compact dimensions facilitate
straightforward mounting on DIN-rail.
Primary use are applications involving supplies to
motors, valves and other load circuits with a high
power consumption, where an accurate output
voltage regulation which is standard on traditional
switched-mode power supplies is not required.
Furthermore, these switched-mode power supplies
can often replace mains transformers with rectifiers.
XT40.361, XT40.362
36V, 26A, THREE-PHASE INPUT
SEMI-REGULATED POWER SUPPLY
• Alternative or Replacement for AC Transformer
• Three Phase Input – DC Output
• DIN-Rail Mountable
• Width only 96mm
• 95.5% Efficiency
• 125% Peak Power Capability
• No Input Inrush Current
• Active Input Transient Blocker
• Full Power Between -25°C and +60°C
• Easy Failure Diagnostics
• No Electrolytic Capacitors on Input Side
• Cost Effective and Robust
• 3 Year Warranty
2. SHORT-FORM DATA
Output voltage DC 36V
Adjustment range none
Output current 26.6A continuous
33.3A for typ. 15s
Output power 960W continuous
1200W for typ. 15s
Output ripple < 2000mVpp 20Hz-2kHz
< 250mVpp 2kHz to 20MHz
Input voltage 3AC 400V XT40.361
3AC 480V XT40.362
Mains frequency 50-60Hz ±6%
AC Input current 1.65A / phase XT40.361, 3x400V
1.4A / phase XT40.362, 3x480V
Power factor 0.93 36V, 26.6A
AC Inrush current typ. 2A peak
Efficiency 95.5%
Losses 45.2W
Temperature range -25°C to +70°C operational
Derating 24W/°C +60 to +70°C
Dimensions 96x124x159mm WxHxD
3. ORDER NUMBERS
Power Supply
Jan. 2007 / Rev. 1.0 DS-XT40.36x-EN All parameters are specified at 36V 13.3A, 3x400Vac (XT40.361) or 3x480Vac (XT40.362),
25°C ambient and after a 5 minutes run-in time unless otherwise noted.
XT40.361
XT40.362
400V Input
480V Input
www.pulspower.com Phone +49 89 9278 0 Germany
4. MARKINGS
LISTED
IND. CONT. EQ.
UL 508
18WM
UL 60950-1
EMC, LVD
1/20
– X-Series
XT40.361, XT40.362
36V, 26A, THREE-PHASE INPUT
INDEX PAGE INDEX PAGE
1.
General Description ............................................1
2. Short-form Data ..................................................1
3. Order Numbers....................................................1
The power supply shall only be installed and put into operation by qualified personnel.
This power supply is designed for installation in an enclosure and is intended for the general use, such as in industrial
control, office, communication, and instrumentation equipment. Do not use this device in aircraft, trains and nuclear
equipment, where malfunctioning of the power supply may cause severe personal injury or threaten human life.
TERMINOLOGY AND ABREVIATIONS
PE and symbol PE is the abbreviation for Protective Earth and has the same meaning as the symbol .
Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”.
T.b.d. To be defined, value or description will follow later.
3AC 400V A figure displayed with the AC or DC before the value represents a nominal voltage with
standard tolerances (usually ±15%) included. 3AC means three phase input.
E.g.: DC 12V describes a 12V battery disregarding whether it is charged (13.7V) or
discharged (10V).
As long as otherwise stated, 3AC 400V parameters are valid at 50Hz and 3AC 480V
parameters are valid at 60Hz mains frequency.
3x 400Vac A figure with the unit (Vac) at the end is a value which is used during testing without any
additional tolerances included. 3x 400Vac means a three phase input.
DISCLAIMER
The information presented in this document is believed to be accurate and reliable and may change without notice.
Jan. 2007 / Rev. 1.0 DS-XT40.36x-EN All parameters are specified at 36V 13.3A, 3x400Vac (XT40.361) or 3x480Vac (XT40.362),
25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
2/20
– X-Series
XT40.361, XT40.362
36V, 26A, THREE-PHASE INPUT
5. AC-INPUT
XT40.361 XT40.362
AC input nom. 3AC 400V 3AC 480V
Mains arrangement TN-, TT- or IT-Mains consult factory if one phase is earthed
AC input range
min. 3x 360-440Vac 3x 432-528Vac fully regulated output (±2%), Pout > 48W
min. 3x 300-460Vac
*)
3x 360-552Vac
*)
max. 3x 475Vac 3x 565Vac Absolute maximum input voltage with no
Input frequency nom. 50 – 60Hz 50 – 60Hz ±6%
Turn-on voltage typ. 3x 325Vac 3x 390Vac see Fig. 5-2
Shut-down voltage typ. 3x 295Vac 3x 355Vac see Fig. 5-2
Input current
nom. 1.65A 1.4A at 26.6A, symmetrical input, see Fig. 5-4
Power factor **) typ. 0.93 0.93 at 26.6A, symmetrical input, see Fig. 5-5
Turn-on overshoot typ. 700mV 700mV see Fig. 5-3
Start-up delay ***) typ. 400ms 350ms over the entire load range, see Fig. 5-3
Rise time typ. 40ms 40ms 0mF, 26.6A, see Fig. 5-3
*) A minimum voltage of 3x340Vac (XT40.361) or 3x408Vac (XT40.362) is required to turn the power supply on.
**) The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit.
***) The start-up delay for mains voltage interruptions up to 350ms is zero. In such cases, the power supply will immediately
generate the output voltage once the mains voltage interruption is over.
typ. 70ms 70ms 27mF, 26.6V, see Fig. 5-3
Input Voltage Range
Fig. 5-1 Output voltage vs. input voltage and input current
permanently allowed,
see Fig. 5-1 for output voltage regulation
damage to the power supply. Output
might be off at this level.
Changes of the input voltage will be fully
regulated within certain limits. The
output voltage will only start to change
proportionally to the input voltage with
extreme under or over-voltages. The
V
OUT
42V
39V
P
OUT
> 48W (>5%)
P
OUT
= 0W
yellow LED reports an input voltage
problem if exceeded by a window of
±15%. The maximum increase of the
output voltage is limited to the 42.5V
OVP level. This level will be kept
regulated for 2s before the power supply
will shut down and reports “Shut-down”
by the red LED.
36V
33V
30V
XT40.361:
XT40.362:
420340480Vac320
400360 380440
504456576Vac384
480
528 552432408360
V
460300
Jan. 2007 / Rev. 1.0 DS-XT40.36x-EN All parameters are specified at 36V 13.3A, 3x400Vac (XT40.361) or 3x480Vac (XT40.362),
25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
IN
3/20
– X-Series
XT40.361, XT40.362
36V, 26A, THREE-PHASE INPUT
Fig. 5-2 Input voltage range Fig. 5-3 Turn-on behavior definitions
P
OUT
Turn-on
Shut-down
Fig. 5-4 Input current vs. output load Fig. 5-5 Power factor vs. output load
Input Current per Phase, typ.
1.8A
1.5
1.2
0.9
0.6
0.3
0
4820
fully regulated
range
3x 432Vac480V Version:
1
6
3
.
0
4
T
X
4
T
X
Output Current
12 16
x
3
(
6
3
.
0
3x 440Vac3x 360Vac400V Version:
3x 528Vac
)
V
0
0
4
V
0
8
4
x
3
(
2
28
24
)
V
IN
32A
Intput
Voltage
Output
Voltage
Power Factor, typ.
1.0
0.95
0.9
0.85
0.8
0.75
0.70
482028
- 5%
Start-up
delay
Output Current
12 1624
Rise
Time
Overshoot
32A
6. INPUT INRUSH CURRENT
There is virtually no input inrush current surge as there are no electrolytic bulk-capacitors utilized on the input side of
the power supply.
The charging current into the EMI suppression capacitors is disregarded for the first millisecond after switch-on.
Inrush current max. 4A
Inrush energy max. 5A2s 5A2s -25°C to +70°C, see Fig. 6-1
Inrush delay
Fig. 6-1 Input inrush current, typical behavior
A
typ. 400ms 350ms see Fig. 6-1
Input Current
Input Voltage
Output Voltage
XT40.361 XT40.362
4A
peak
-25°C to +70°C, see Fig. 6-1
peak
A: Inrush delay
XT40.361:
Input: 3x400Vac, only one phase shown
Output: 36V, 26A
Ambient: 25°C
Upper curve: Input current 2A / DIV
Medium curve: Input voltage 500V / DIV
(measured between L and N)
Lower curve: Output voltage 30V / DIV
Time basis: 100ms / DIV
Jan. 2007 / Rev. 1.0 DS-XT40.36x-EN All parameters are specified at 36V 13.3A, 3x400Vac (XT40.361) or 3x480Vac (XT40.362),
25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
4/20
– X-Series
XT40.361, XT40.362
36V, 26A, THREE-PHASE INPUT
7. OUTPUT
Output voltage
Output voltage adjustment range
Output current
33.3A up to 15s with full output voltage, see Fig. 7-1
Short-circuit current
Output power
1200W up to 15s
Line regulation
Load regulation max. 1200mV static value, 0A Æ 26.6A Æ 0A
Ripple and noise voltage *)
max. 250mVpp 2kHz to 20MHz, 50Ohm
Output capacitance
*) The ripple and noise voltage mostly consist of a mains ripple with 300Hz (50Hz mains) or 360Hz (60Hz mains). The ripple and
noise voltage can be reduced by the utilization of external capacitors.
The power supply is also designed to support loads with a higher short-term current and power requirement. The
short-term duration is firmware controlled by an output power manager. If the nominal output power is exceeded for
a certain period of time which is defined in the zone A, B and C, the power supply responds with an automatic shutdown. Pressing the reset button or cycling the input power (10s off time is required) initiates an attempt to restart. If
the fault has been cleared the device will operate normally.
The short term power can be used periodically. See chapter 25.1 for further information.
Fig. 7-1 Output voltage vs. output current, typ.
nom. 36V
none The output voltage is fixed. No adjustment possible
nom. 26.6A continuous, see Fig. 7-1
min. 115A load impedance 40mOhm, see Fig. 7-1
Note: The short-circuit current is available for 0.1s
Jan. 2007 / Rev. 1.0 DS-XT40.36x-EN All parameters are specified at 36V 13.3A, 3x400Vac (XT40.361) or 3x480Vac (XT40.362),
25°C ambient and after a 5 minutes run-in time unless otherwise noted.
Hold-up Time typ. 2.6ms 2.6ms 26.6A, resistive load, see Fig. 8-2typ. 2.2ms 2.2ms 26.6A, constant power load, see Fig. 8-2typ. 5.2ms 5.2ms 13.3A, resistive load
typ. 4.4ms 4.4ms 13.3A, constant power load
Hold-up Time min. 2.1ms 2.1ms 26.6A, resistive load, see
min. 1.8ms 1.8ms 26.6A, constant power load, see Fig. 8-2min. 4.2ms 4.2ms 13.3A, resistive load
min. 3.5ms 3.5ms 13.3A, constant power load
The energy is stored in the output capacitor. As
soon as the input is turned off, the output
capacitor will be discharged and the voltage will
dissipate according to the curves in
lighter the load, the longer the hold-up time. Half
the load means twice the hold-up time.
The hold-up time depends on the load
Fig. 8-2. The
Intput
Voltage
characteristic. The curves below show the hold-up
time for a load with a resistive and a constant
power characteristic.
The hold-up time is defined as the period of time
Output
Voltage
when the input is turned off and until the output
–15%
voltage falls below 36V
(30.6V). This value is
defined in the IEC61131-2 as the lower limit for the
supplying voltage.
Fig. 8-2 Hold-up time vs. input voltage
Fig. 8-2
Fig. 8-1 Hold-up time, definitions
Zero Transition
Hold-
up
Time
-15%
V
OUT
36V
33V
30.6V
27V
24V
21V
18V
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
5.5 6.0 6.5 7.0 7.5 8.05.08.5 9.0
26.6A, constant power load, min.
26.6A, constant power load, typ.
26.6A, resistive load, min.
26.6A, resistive load, typ.
11ms9.5 10 10.5
Note: At no load, the hold-up time can be up to one minute. The green DC-ok LED is on during this time.
Jan. 2007 / Rev. 1.0 DS-XT40.36x-EN All parameters are specified at 36V 13.3A, 3x400Vac (XT40.361) or 3x480Vac (XT40.362),
25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
T
6/20
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.