Puls SL10.104 Data Sheet

Data sheet SilverLine
12-15V adjustable, 180W
SL10.104
• Input: AC 230/115V, DC 240...375V
• Output: 12-15V/180W
• PULS Overload Design 20% Power boost up to 215W; high overload current, no switch-off
• Robust mechanics and EMC
• DC ok LED
• Inrush current limiting and Overtemperatur protection
UL60950 E137006
CUL/CSA-C22.2
No 60950
UL508 LISTED IND. CONT. EQ.
18 WM, 60°C
EMC and Low Volt. Directive
Input
Input voltage AC100-120/220-240V (Manual Select),
50-60 Hz (AC 85...132/176...264V, DC 240...375V, 47-63 Hz)
Note: At DC input, always leave the switch in the 230V position
Input current I
Inrush current I
Fuse loading I²t 4.6A²s 6.8A²s 4.2A²s
at T
amb
Unit is internally fused (fuse not accessible). For external fusing of unit and for input line protection, use circuit breaker with B-characteristic 10A or slower action, or alternatively T10A HBC fuse.
Harmonic current emissions (PFC)
Transient handling
Hold up time 45,7 / 84,6 / 81,3ms (bei AC 100/120/230V,
IT Mains allowed
n
pk
= +50°C, cold start
<5A (switch in 115V position) <2.3A (switch in 230V position)
AC 100V AC 120V AC 230V
37A 45A 51A
AC 100V AC 120V AC 230V
0.67 0.64 0.54
above 98W > class A
Transient resistance acc. to VDE 0160 / W2 (750V/1.3ms), for all load conditions.
12V/15A) (see Diagram overleaf)
Efficiency, Reliability etc.*
Efficiency >87% (AC 230V, 12V/15A)
Losses <26.9W (AC 230V, 12V/15A)
MTBF 425.000h acc. to Siemensnorm SN 29500
(12V/15A, AC 230V, T
Lifetime expectancy (electrolytics)
The unit uses longlife electrolytics, specified for +105°C (cf. ’The SilverLine’, p.2).
* For further information see data sheets „The SilverLine“,
„SilverLine Family Branches“ and mechanics data sheet
amb
= +40°C)
Output
Output voltage DC 12-15V, adjustable by (covered) front pan-
el potentiometer; preset: 12V ±0.5% Adjustment range guaranteed
Rated continuous loading with convection cooling
•T
=0°C - 60°C
amb
•T
=0°C - 45°C
amb
Output is protected against short-circuit, open circuit and overload
Short-circuit current 21A min. ,28A max.
Ambient temperature range T
amb
Derating typ. 5 W/K (at T
Voltage regulation < - 150mV overall
Ripple / Noise <50mV
Serial operation not allowed
Parallel operation not allowed
Overvolt. protection typ. 19V
Power back immunity < 18V
Front panel indicator Green LED on front panel
12V/15A (180W) resp. 15V/12A 12V/18A (215W) resp. 15V/14.4A short-term also at 60°C (< 1 min)
Operation: 0°C...+70°C (>60°C: Derating) Storage: -40°C...+85°C
= +60°C...+70°C)
amb
, (20MHz bandw., 50Ω measurement)
PP
Construction / Mechanics*
Housing dimensions and Weight
•W x H x D
• Free space for ventilation
•Weight
Connection Screw terminals , input=3, output=4
• Wire gauge
• Recomm. tightening torque
• Wire stripping length
Design advantages:
• All connection blocks are easy to reach as mounted at the front panel.
120mm x 124mm x 102mm (+ DIN rail) above/below 25mm recommended left/right 15mm recommended 980g
0,5...4mm 0,8Nm / 7lb.in
7mm / 0,275”
2
/ 20...10 AWG
Ordering information
Order number Description
SL10.104 SLZ14 SLZ02
sl10e104 / 040511 1/2
SilverLine switched-mode power supply Adapter for S7-300 rail Wall mounting set
Data sheet
Start / Overload Behaviour
Startup delay typ. 0,22s
Rise time 5...25ms, depending on load
Overload Behaviour
• Special PULS Overload Design (see diagram overleaf)
– no disconnection, no hiccup if overloaded – high overload current (up to 2.2 I
Vout is gradually reduced with increasing
Nom
),
current.
• 20% power boost
– 18A short-term
, at 45°C or forced cooling
even continuous
Advantages:
• High short-circuit current, giving large ’start-up window’: unit starts reliably even with heavy loads (DC-DC converters, motors).
• No ’sticking’ such as can occur with fold-back characteristics
• Secondary fuses operate more reliably
Electromagnetic Compatibility (EMC)
Emissions
• EN 61000-6-4, Class B (EN 55011, EN 55022)
• EN 61000-3-3
• Output power less than 98W: EN 61000-3-2 Class A and EN 61000-6­3 are fulfilled.
• Output power more than 98W: EN 61000-3-2 Class A and EN 61000­6-3 are not fulfilled.
Immunity EN 61000-6-2 (also includes EN 61000-6-1)
• Electrostatic
EN 61000-4-2, Level 4 (15kV; 8kV)
Discharge (ESD)
• Electromagnetic
EN 61000-4-3, Level 3 (10V/m)
radiated fields
• Burst, coupled to:
– ACin-lines – DCout-lines
• Surge transients
– (L -> PE) –(N -> PE) –(L -> N)
• Conducted noise immunity
EN 61000-4-4, Level 4 (4kV) Level 3 (2kV)
EN 61000-4-5 Installation class 4 (4kV) Installation class 4 (4kV) Installation class 4 (2kV)
EN 61000-4-6, Level 3 (10V, 150kHz - 80MHz)
• Voltage Dips EN 61000-4-11
• Transient immunity Transient resistance acc. to VDE 0160/W2
over entire load range
Further information
For further information, especially about
•EMC
• Connections
• Safety, Approvals
• Mechanics und Mounting,
see page 2 of the „The SilverLine“ data sheet.
For detailed dimensions
see SilverLine mechanics data sheet SL2.5/ SL5/ SL10
Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in time. They are subject to change without prior notice.
Your partner in power supply:
16
14
12
10
Output Voltage [V]
8
6
4
2
0
0246810121416182022242628
89
88
87
Efficecny [%]
86
85
84
83
82
81
80
79
1,5 3,0 4,5 6,0 7,5 9,0 10,5 12,0 13,5 15,0
30
25
20
Power Loss [W]
15
10
5
0
0,0 1,5 3,0 4,5 6,0 7,5 9,0 10,5 12,0 13,5 15,0
180
160
140
120
Hold-up time [ms]
100
80
60
40
20
0
85 105 125 145 165 185 205 225 245
Overload Behavior AC 230V typ.
0°C 25°C 45°C 60°C
Efficiency
Pow er Losses
100 Vac
120 Vac
230 Vac
Hold-up Time
typ. (Load 50%)
min. (Load 50%)
typ. (Load 100%)
min. (Lo ad 100%)
European Power Supply Manufacturers Association
Input Current [A]
100 Vac
120 Vac
230 Vac
Output Current [A]
Output current [A]
SL10.104
Input Voltage VAC [V]
Bayerns Best 50 Czech 100 Best Europe’s 500
PULS GmbH
Arabellastraße 15
D-81925 München
Tel.: +49 89 9278-0
Fax: +49 89 9278-199
www.puls-power.com
2/2 sl10e104 / 040511
Loading...