The most outstanding features of this Dimension Q­Series power supply are the high efficiency and the small size, which are achieved by a synchronous rectification and further novel design details.
With short-term power capability of 150% and built­in large sized output capacitors, these features help start motors, charge capacitors and absorb reverse energy. A wide range input voltage design and a negligible low input inrush current make installation and usage simple. Diagnostics are easy due to the DC-ok relay, a green DC-ok and a red overload LED.
Unique quick-connect spring-clamp terminals allow a safe and fast installation. Many global approvals make this unit suitable for nearly every situation.
QS20-Series
Related products
QS10.241
Less
Power
QS20.241
Conformal
coated
36V Output
48V Output
only 200-240V
Input, no PFC
QS20.241-C1
QS20.361
QS20.481
QS20.244
3. ORDER NUMBERS
Power Supply
QS20.241 QS20.241-C1
24-28V unit
conformal coated unit Accessory ZM1.WALL Wall mount bracket ZM15.SIDE Side mount bracket YR2.DIODE Decoupling module
QS20.241, QS20.241-C1
24V, 20A, SINGLE PHASE INPUT
POWER SUPPLY
AC 100-240V Wide-range Input
Efficiency up to 93.9%
Width only 82mm
150% Peak Load Capability
Active Power Factor Correction, PFC
DC Input from 88 to 375Vdc
Short-term Operation from 60Vac to 300Vac
Full Power Between -25°C and +60°C
Negligibly Low Inrush Current
DC-OK Relay Contact
Quick-connect Spring-clamp Terminals
3 Year Warranty
2. SHORT-FORM DATA
Output voltage DC 24V Adjustment range 24-28V Output current 20A continuous, 24V 30A for typ. 4s, 24V Output power 480W continuous, 24V 720W for typ. 4s, 24V Output ripple < 100mVpp 20Hz to 20MHz Input voltage AC 100-240V ±15% Mains frequency 50-60Hz ±6% AC Input current 4.56 / 2.48A at 120 / 230Vac Power factor 0.95 / 0.90 at 120 / 230Vac AC Inrush current typ. 9 / 7A peak at 120 / 230Vac DC Input voltage DC 110-300V DC Input current 4.7 / 1.7A at 110 / 300Vdc Efficiency 92.4 / 93.9% at 120 / 230Vac Losses 39.6 / 31.4W at 120 / 230Vac Temperature range -25°C to +70°C operational Derating 12W/°C +60 to +70°C Hold-up time typ. 32 / 51ms at 120 / 230Vac Dimensions 82x124x127mm WxHxD
4. MARKINGS
18WM
LISTED
IND. CONT. EQ.
UL 508
UL 60950-1 Class I Div 2
GL
Marine
-
-20%/+25%
EMC, LVD
R
CUS
182790
Jan. 2008 / Rev. 1.3 DS-QS20.241-EN All parameters are specified at 24V, 20A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.