11. FUNCTIONAL DIAGRAM
Fig. 11-1 Functional diagram
L
N
Input Fuse & Input Filter
Input Rectifier & Inrush Limiter
Converter
Output Over-
Voltage
Protection
Power
12. RELIABILITY
Output
Filter
Output
Voltage
Regulator
ML15.051
5V, 3A, SINGLE PHASE INPUT
DC on
+
-
-
V
OUT
These units are extremely reliable and use only the highest quality materials. The number of critical components such as electrolytic capacitors has been reduced.
AC 100V AC 120V AC 230V
Lifetime expectancy min. 66 000h 70 000h 93 000h 40°C, 5V, 3A min. > 15 years > 15 years > 15 years 40°C, 5V, 1.5A min. > 15 years > 15 years > 15 years 25°C, 5V, 3A MTBF SN 29500, IEC 61709 2 479 000h 2 838 000h 2 686 000h 40°C, 5V, 3A 4 066 000h 4 654 000h 4 405 000h 25°C, 5V, 3A MTBF MIL HDBK 217F 1 175 000h 1 251 000h 1 145 000h 40°C, 5V, 3A, Ground Benign GB40 1 575 000h 1 676 000h 1 534 000h 25°C, 5V, 3A, Ground Benign GB25
The Lifetime expectancy shown in the table indicates the operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors.
Lifetime expectancy is specified in operational hours. Lifetime expectancy is calculated according to the capacitor’s manufacturer specification. The prediction model allows a calculation of up to 15 years from date of shipment.
MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product.
Dec. 2007 / Rev. 1.1 DS-ML15.051-EN All parameters are specified at 5V, 3A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.