![](/html/57/57a9/57a9b29e43532cc935f38392cff2cd714fc57db8bdb001b106b234da10e84e05/bg1.png)
PULS does it again:
practical, versatile and reliable like
the SilverLine – yet small like
no other.
Data Sheet
MiniLine
with DC 48-56V / 100W
• Mounted and connected
in record time, no tools required
• World-wide approvals (UL, EN, CSA,
CB Scheme) for industry and office/
home
• Tiny: WxHxD = 73 x 75 x 103mm
• Adjustable output voltage
up to DC 56V
• 115/230V Auto Select Input
• PULS Overload Design™
(high output overload capability)
• Selectable single/parallel operation
(jumper)
PULS GmbH, Arabellastrasse 15, 81925 Munich
Tel. +49.(0)89.9278-244, Fax: +49.(0)89.9278-199
sales@puls-power.com, http://www.puls-power.com
Mini is more.
ML100e105/040504
![](/html/57/57a9/57a9b29e43532cc935f38392cff2cd714fc57db8bdb001b106b234da10e84e05/bg2.png)
Technical Data ML100.105
s
p
m
a
l
C
g
n
i
r
p
S
X Input
Input voltage AC 100-120/220-240V (Auto Select), 47...63 Hz
(AC 85...132V / AC 184...264V,
DC 220...375V, N= + and L= - )
Input current <2.1A (@ AC 100V
<1A (@ AC 220V
, 100W P
in
, 100W P
in
out
out
)
)
External fusing not required, unit provides internal fuse
(T3A15H, not accessible)
Transient immunity Transient resistance acc. to VDE 0160 / W2
(750V/ 1.3 ms), over entire load range
Hold-up time
(see diagram below)
>40 ms @ AC 230V, 48V / 2.1A
>20 ms @ AC 196V, 48V / 2.1A
>20 ms @ AC 100V, 48V / 2.1A
X Efficiency, Reliability
Efficiency
Losses
MTBF (Reliability) appr. 500.000 h acc. to Siemensnorm SN 29500
Prior to shipment, every unit undergoes the following tests in order to
isolate any defective units which might suffer an early failure:
• Run-in / burn-in (Full load, T
• Functional test (100 %)
typ. 91% (AC 230V, 48V / 2.1A)
(see also diagram below)
typ. 10W (AC 230V, 48V / 2.1A)
48V / 2.1A, AC 230V, T
= +60°C, on/off cycle)
amb
= +40 °C)
amb
X Construction, Mechanics, Installation
Robust plastic housing (US Patent No. D442, 923S), fine ventilation grid
on three housing sides to keep out small parts (e.g. screws), IP20
Dimensions and weight
• W x H x D
•Weight
Mounting orientation ,
Ventilation/Cooling
• Free space f. cooling
Easy snap-on mounting onto the DIN-rail (TS35/7,5 or TS35/15).
Unit sits safely and firmly on the rail; no tools required even to remove
Connection by Spring Clamp terminals; uniformly firm hold,
Connector size range
• flexible cable
• solid cable
73 mm x 75 mm x 103 mm (+ DIN rail)
Depth incl. terminals: 98 mm (+ DIN rail)
360 g
or (cf. ’Output’)
Normal convection, no fan required
recom’d.: 25mm on sides with ventilation grid
vibration-resistant and maintenance-free:
2 terminals per output
2
0.3-2.5mm
0.3-4mm
(28-12 AWG)
2
(28-12 AWG)
X Output
Output voltage
• preset
Voltage regulation stat. <1% V
Ripple/Noise <50mV
Overvoltage prot. (OVP) <60V
Rated continuous
loading
Overload behaviour PULS Overload Design™: No switch-off at
Protection Unit is protected against (also permanent) short-
Derating depending on built-in orientation;
Parallel operation yes (selectable by front panel jumper)
Power back immunity 63V
Operating indicator Green LED
DC 48-56V (adj. by front panel potentiometer)
48V ± 0.5% @ 2.1A
(Jumper in pos. 'Single Use')
stat. <3% V
dyn. ±1.5% V
out
(Jumper in pos. 'Parallel Use'),
out
over all
out
(20 MHz bandw., 50 Ω measurem.)
PP
up to 2.1A @ 48V / 1.8A @ 56V (convection cooling), depending on built-in orientation,
and T
V
in
For details see derating diagram below
overload/short-circuit, instead: up to 1.9 ⋅ I
So you need no oversizing to start awkward
amb
rated.
loads.
circuit, overload and open-circuit.
see diagram below
X Environmental Data, EMC, Safety
Ambient temperature range (measured 25 mm below unit)
• storage/transport
• operation
Humidity max. 95% (without condensation)
Electromagnetic
emissions (EME)
Electromagnetic
immunity (EMI)
Safe low voltage:
Prot. class/degree:
This unit fulfills all major safety approvals for EU (EN 60 950, EN 60204-
1, EN 50178), USA (UL 60950, E137006, UL508 LISTED, E198865), Canada
(CAN/CSA-C22.2 No 60950 [CUR], CAN/CSA-C22.2 No. 14 [CUL]), CB Scheme
(IEC 60950).
-25°C ... +85°C
-10°C ... +70°C (for derating see diagram below)
EN 61000-6-3 (includes EN 61000-6-4)
Class B (EN 55011, EN 55022)
EN 61000-3-2 (PFC)
EN 61000-6-2 (includes EN 61000-6-1)
SELV (EN 60950, VDE0100/T.410), PELV (EN 50178)
Class 1 (EN 60950) / IP20 (EN 60529)
Ferrules admissible
• Wire strip length
6mm (0.24in) recommended
Design details – for your advantage:
• All terminals are easy to reach as mounted on the front panel.
• Input and output are strictly apart from each other (input below, output above) and so cannot be mixed up.
• Mounting and connection do not require any screwdriver
→ Easy, quick, durable and reliable installation.
X Diagrams
Output characteristic V
(min.)
64
56
48
40
32
24
16
Output voltage Vout [V]
Product information (ML100e105), Rev.: 4. May 2004. Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in time. They
are subject to change without prior notice.
PULS GmbH, Arabellastraße 15, D-81925 München X Tel: +49.(0)89.9278-244, Fax: +49.(0)89.9278-199, E-Mail: sales@puls-power.com X www.puls-power.com
Vin = AC 115/230V
'Single Use'
Vin = AC 115/230V
8
'Parallel Use'
0
012345
Outpu t curren t Iout [A]
out/Iout
Efficiency
(@ V
= 48V, typ.)
out
93
92
91
90
89
88
87
Efficiency [%]
86
85
84
83
0,5 0,75 1 1,25 1,5 1,75 2 2,1
Outpu t curre nt Iou t [A]
230 VACin
115 VACin
Derating
of output power
120
A
100
80
60
Mounting
40
Output power [W]
85-132 V ACin A-a A-b A-b
185-264 V ACin A-a A-b A-b
20
220-375 V DCin A-a A-b A-b
0
-10 0 10 20 30 40 50 60 70
Ambient temperature [°C]
Hold-up time with ACin
(at V
a
b
= 48V, typ. + min.)
out
160
140
120
100
80
60
Hold-up time [ms]
40
20
0
80 120 160 200 240 280
Inpu t voltage VACin [V]
Pout=100W, typ.
Pout=100W, min.
Pout=50W, typ.
Pout=50W, min.