PULS DP177 User Manual

DP177 1 Output
DIN Rail Power Supply, 240 Watt
High efficiency: 88%
ACin autoselect: 115/230V (@ DP177.102, 104)
WxHxD = 225x110x130mm
Parallel mode automatic load sharing
Over-Temperature Protection (OTP)
Over-Voltage Protection (OVP)
Meets EMV standards
VDE 0160/2, EN 61000-4, NAMUR, EN 50081-1 (EN 55022/B) and EN 50082-2
Design meets VDE 0551
The DP 177 is a compact solution for applications supplying controllers, sensors, actuators in industrial plants, and heavy machines. Output voltage is stable over the total load ran ge,and have excellent ripple and noise values below 20mVp p at 24V DC.
Multiple units can supply current in parallel, by con­necting their symmetry terminals to ensure each supp­lies an equal share of the current. Light weight and small size allow quick and easy installation on DIN rails.
Line voltage disturbance and noise im munity satisfies EN 61000-4 and VDE 0160 pulses (class 2 for total load range!). The unit is over-voltage and short-circu it protected. Isolation is equivalent to safety transformers according to VDE 0551, and it meets VBG 4.
www.puls-power.de
Schematic:
See the web for current data sheet version:
Power Supply DP177
Vout Iout Pout Features Order-No.
24V 10A 24V 10A
28V 8.5A 28V 8.5A
48...60V 4A
Warranty: 2 years from date of delivery.
Output
Voltage Vout adjustable min. ± 5% DP177.101 ... DP177.104
Accuracy max. ± 1% Includes: production-adjustment,
Sense lines None Not available. Minimum load None Not necessary. Output power Pout max. 240W With single or parallel operation. Noise, Ripple max. 50mVpp 20Hz...200kHz.
incl. spikes max. 100mVpp 20Hz...20MHz.
Over-voltage protection
DP177.101, 102 typ. 26.4V Threshold accuracy ± 4%. DP177.103, 104 typ. 30.8V Threshold accuracy ± 3%.
DP177.105 typ. 66.0V Threshold accuracy ± 2%. Derating 6W/K +55° to +70°C Ta. Operating indicator 1 green LED Seen through grill, see page 4. Isolation Vout to Vin SELV EN 60 950, VDE 0805. The output is protected against open-circuit, short-circuit, and overload.
240W OVP, OTP, parallel mode 240W OVP, OTP, parallel mode, autoselect
238W OVP, OTP, parallel mode 238W OVP, OTP, parallel mode, autoselect
240W OVP, OTP, parallel mode, autoselect
min. 48...60V DP177.105
line regulation, and load regulation.
DP177.101 DP177.102
DP177.103 DP177.104
DP177.105
Mechanical: Al/Mg alloy housing, snap-on mounting for
Weight: App. 1360g
Screw terminals: Input 1 terminal, max. 2.5mm
PULS Munich
Tel.: +49 (0)89 / 92 78-2 44
/ DP177_
Page 1
DIN rail TS35/7.5 (EN 50 022), WxHxD = 225 x 110 x 130mm, the depth includes the DIN-rail mounting, see page 4.
2
output 2 terminals, each max. 2.5mm see page 4.
10.Mar.99
Fax: +49 (0)89 / 92 78-1 99
,
Arabellastraße 15
D- 81925 München
2
,
Input
Line input AC 1 100...127V AC Bridge operation for 115V.
110...120V AC Units with ACin autoselect
Range 92...132V AC Full spec.
80...92V AC Derated, see page 2.
Line input AC 2 220...240V AC 230V-operation.
Range 184...264V AC Full spec.
150...184V AC Derated, see page 2. Line frequency 47...63Hz DC or 400Hz, see page 2. Input current rms. max. 4.0Aeff. / 1.8Aeff. @ 115 / 230V AC. Noise suppression EN 55 022/B 10kHz...30MHz, conducted.
Specifications are valid at 230V AC, unless otherwise stated. They are subject to change without prior notice.
DP177 ◆ 1 Output ◆ DIN Rail Power Supply ◆ 240 Watt
.101 .103
Output (continued) DP177.
Voltage regulation:
Line regulation max. %
Load regulation stat.
Load regulation dyn.
Response time t Temperature coefficient typ. %/K
Ripple max. mVpp 50 50 50
incl. spikes max. mVpp 100 100 100
Current limitation
Threshold min/max. A 105% ... 130% of Iout
Characteristic See graph on page 3
Short-circuit max. A 140% of Iout
Start delay t
Vout rise-up time t On and off characteristic Power back immunity U
(continued)
Input
AC input range 1 / 2 V AC 92...138 / 184...264 DC input range V DC 250...300
Derated AC range 1 / 2 V AC 80...92 / 150...184, 150 / 300 for 0.5s Derated DC range V DC 170...250
Frequency range Hz 47...63 Derated frequency range Hz 63...440 In-rush current max. A 20
Hold-up time min. ms 17
Power factor Internal fuse 5x20mm T4A/250V Input range selection DP177.101, 103, 105 Manual (230V AC set at factory)
U
max. %
stat
U
max. %
dyn
max.
s
typ. ms 400 400 400
Delay
t
typ. ms 30 30 30
Delay
typ. ms 70 70 70
Rise
max. V 1.2xVout 1.2xVout
Back
V DC 300...370
min. ms 20
λ
typ. 0.60
DP177.102, 104 Automatic
.102 .104 .105
±
0.02
±
0.1
±
2
µ
s 500 500 500
±
0.01
±
0.02
±
0.1
±
2
±
0.01
±
0.02
±
0.1
±
2
±
0.01
92...132V AC / 184...264V AC, Iout = 100%. Iout = 50%, ∆ Iout = ±50%.
Iout = 10%...90%...10%, rise time dt = typ. 20µs. Till ∆Vout is within < 0.5% of final value.
20Hz...200kHz, @AC nom, Iout = 100%. 20Hz...20MHz, @AC nom, Iout = 100%.
Fixed.
@ 115V AC @ 230V AC
Approximately monotonic. Unit off/on.
Full spec. Full spec, for autoselect operation take the polarity into consideration. No start below 92V AC / 184V AC Power derating typ. 10%, no start below 250V DC. Full spec, but air- and leakage distances not longer than stated in VDE 0805. Full spec. Increased leakage currents. @ 230V AC, wait min. 30s before switching on again (cold-start), NAMUR standard met (Ta = 25° C). @ 92V AC, Iout = 100%. @ 184V AC, Iout = 100%, see figure on page 3. @ 92V AC, Iout = 100%. L and N, as per IEC 127/2-5. To replace, see page 4. Set a bridge between Y1 and Y2 for 115V-operation.
95%
t
0
90% 10%
t
DelaytRise
100Hz
Vout
Logic Functions
Parallel operation max. 10 units
Current distribution Equal
Connection Connect SYM-terminals
Vout adjustable DP177.101 ... 104 min. %
±
5
±
5
Vout adjustable DP177.105 min. V 48...60
Electromagnetic Compatibility
Emissions according to 50081-1
Radio interference, EN 55011, EN 55022 Class B
Immunity according to 50082-2
Electrostatistic discharge ESD, EN 61000-4-2 8kV direct discharge (level 4)
15kV air discharge (level 4)
Radiated fields, EN 6100-4-3 10V/m (level 3)
Fast transients, EN 61000-4-4 4kV (level 4)
2kV (level 3) 2kV (level 4) cap. coupling
Surge transients, EN 61000-4-5 4kV (isolation class 4)
2kV (isolation class 4)
Transient voltage, IEC 255 5kV
NAMUR-prescription Satisfied
Transient resistance, VDE 0160 §5.3.1.1.2 750V / 1.3ms (class 2)
Over-voltage resistance (PULS standard) 150/300V AC / 0.5s
PULS Munich
Tel.: +49 (0)89 / 92 78-2 44
/ DP177_
Page 2
10.Mar.99
Characteristic see page 3. Use equal-length output cables. Trimmer position see page 4. Trimmer position see page 4.
EN 50081-2 is also satisfied Conducted 10kHz...30MHz. EN 50082-1 is also satisfied
ACin, Vout and SYM lines: length = 1m. Coupled to ACin line. Coupled to DCout line. Coupled to Vout and SYM lines. Common mode, unit on. Differential mode, unit on. Common mode, unit off.
Valid for total load range.
1 Output ◆ DIN Rail Power Supply ◆ 240 Watt ◆ DP177
Minimum Hold-Up Time
260 240 220 200 180 160 140 120 100
80
Hold-Up Time [ms]
60 40 20
0
180 190 200 210 220 230 240 250 260
40% Load
60% Load
80% Load
100% Load
Output Volt age Range 2 [Vac]
Typ. Output Characteristic
64 60 56 52 48 44 40 36 32 28 24 20 16
Output Voltage Vout [%]
12
8 4 0
012345678910111213
Output Current Iout [%]
DP177.105
DP177.103,104
DP177.101,102
Protection
Unit protection
Overload Yes See current limit.
Short-circuit proof Yes Automatic voltage recovery.
Open-circuit proof Yes
Over-temperature (OTP) 100° C int. temp. Switch-off.
Reverse battery prot. Yes DP177.101, 103. 105
ACin range selection Manual DP177.101, 103. 105
Autoselect DP177.102, DP177.104.
Load protection
Over-voltage (OVP) Yes
Threshold typ. 26.4V max. ± 4% DP177.101, DP177.102.
typ. 30.8V max. ± 3% DP177.103, DP177.104. typ. 66.0V max. ± 2% DP177.105.
Safety
Electrical safety
Test voltage (each unit) 3kV AC Primary / secondary.
according to EN 60 950 2.5kV AC Primary / PE. for t = 2sec 500V AC Secondary / PE. Air- and leakage distance 8mm Primary / secondary.
4mm Primary / PE.
Isolation resistance min. 5M
Protection class
PE resistance < 0.1
Protection system IP20 DIN 40050, IEC 529.
Leakage current max. 0.75mA EN 60 950 (47...63Hz line) .
Safe low voltage SELV EN 60 950, VDE 0805, VDE 0160.
Over-voltage class
Touch safety Finger test VDE 0100 §6, EN 60 950, VBG4. Penetration protection
Ι
ΙΙ
> ∅
3mm e.g. screws, small parts etc.
VDE 0551. VDE 0106 part 1, IEC 536 . VDE 0805.
VDE 0110 part 1, IEC 664.
Typ. Derating over Temperature
260 240 220 200 180 160 140 120 100
Output Power Pout [W]
80 60 40 20
50 55 60 65 70 75
240 Wat t
Temperature [+ °C]
Typ. Efficiency
88
87
Efficiency [%]
86
30 50 70 90
Output Power [%]
196Vac 230Vac
Operation and Ambient Area
Application class KSF DIN 40040. Operation temperature max. 0° ... +70°C Ta (measured at 1cm distance).
Derated range +55° ... +70°C Derating, see diagram.
Storage temperature typ. –20° ... +100°C Ta. Humidity max. 95% Non-condensing. Mechanical usage See page 4
Distance to cable channels See page 4
Lateral spacing None No gap needed.
Cooling Normal convection Don’t obstruct air flow. Dirt protection level max. 2 VDE 0110 part 1. Vibration 0.075mm IEC 68-2-6 (10...60Hz). Shock 11ms / 15g IEC 68-2-27 (3 shocks). Operation height max. 2,000m Above sea level.
Efficiency and Power Loss
DP177.101 ... 105 typ. 88% / 33W @ 230V ACin, Iout = 100%.
Reliability and Lifetime
MTBF according to Siemens standard SN29500 typ. 200,000h 230VAC, Iout = 100%, +40°C Ta. Only long life (> 2,000h @105° C) electrolytic capacitors are used. Function test 100% Test certificate enclosed. In-circuit test Yes Run-in (burn-in) 24h Full load, Ta = +55° C,
PULS Munich
Tel.: +49 (0)89 / 92 78-2 44
/ DP177_
Page 3
10.Mar.99
This technical information is valid for +25° C ambient
temperature and 5 min. run in time, unless otherwise stated.
on/off cycle.
DP177 ◆ 1 Output ◆ DIN Rail Power Supply ◆ 240 Watt
ACin auto­range
Controller
For units
without
autorange:
Set a bridge
for 115V AC.
For DC-operation: Take the polarity into consideration! (DP177.102 and .104 only)
OVP
F I L T E R
I -
Regulator
Forward converter
typ. 70kHz
U-
Regulator
~
N L Y1 Y2
ACin
Vout GND
SYM
Snap the unit direct on the DIN rail TS35/7 .5! Install DIN rail hori zont al l y. For verti cal installation contact PULS. The width of 225mm i ncludes the later al case screws. Do not remove any sc rew s o n box , a s i nt ern al safety connecti ons co uld be disconnected!
Weight: typ. 1360g
LED (in the case, seen through grill)
Trimmer (underside)
Fuse
The PSU has electronic protection against external short-circuits. In case of an internal defect, a fuse disconnects the unit. It can only be replaced by opening the unit which should be done by the supplier.
Installation for Operating
Install DIN rail TS35/7.5 horizontally, ensuring correct orientation. For other installation considerations consult your representative. Ensure free air flow.
Dimensions and Connections
Fully enclosed Al/Mg alloy housing. All mechanical dimensions are in mm.
hs
Schematic
h
s
s
h
Required mounting dimensions
Connections at alternati ng volt age
Screw terminals:
NLY1Y2
Vin
~
max. 2.5mm cross section Take care of standards which
must be satisfied, e.g. VDE 0100 or EN 60950.
Vout GND
Modifications (contact supplier)
Negative temperature co-efficient for battery loads. Other DC input voltage ranges. Other output voltage ranges. Lower cost versions.
SYM
Y1 and Y2 only for DP177.101, .103, .105
2
Connections at direct volt age
GND in
Vout GND
PULS Munich
Tel.: +49 (0)89 / 92 78-2 44
Page 4
NL
+Vin
SYM
/ DP177_
10.Mar.99
Arabellastraße 15
D- 81925 München
Fax: +49 (0)89 / 92 78-1 99